Search NASA⌕ Search

SEARCH · Search NASA

Results for “Plant Protection System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Low Activity Waste Pretreatment System Bench-Scale Testing: Supporting Integrated Testing and Facility Safety Analyses - 17171

The Low Activity Waste Pretreatment System (LAWPS) is being designed to enable the direct feed of waste to the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Low Activity Waste (LAW) facility to be immobilized. Prior to construction of the LAWPS, pilot-scale integrated testing of the key unit operations (crossflow filtration, ion exchange using spherical resorcinol-formaldehyde (sRF) resin) will be conducted by a team led by Washington River Protection Solutions (WRPS) to increase the technology maturation level of the facility's critical technology elements. As a part of this effort, Pacific Northwest National Laboratory (PNNL) has conducted a series of tests to perform two major objectives: (1) support pilot-scale integrated testing of the LAWPS by supplying information or performance data in advance of operating the pilot-scale facility (1/9. scale); and (2) collect data needed to establish or confirm assumptions/approaches planned for implementation in the LAWPS safety basis. The first objective was focused in two technical areas: developing simulants that are representative of expected waste feed and can be produced at larger scales, and using these simulants in a bench-scale crossflow filter to establish expected solid-liquid separation performance. The crossflow filter was also used to observe the efficacy (with respect to filter production rate) of selected operational strategies. The second objective also included two technical areas: measuring the effect of sRF resin on hydrogen generation rate under irradiation, and demonstrating that the planned hydrogen management approach is effective and robust. The hydrogen management strategy involves fluidization of the sRF resin bed in the ion exchange columns and recirculating the liquid, a scenario that is planned for testing at full column height. The full height tests at PNNL also supported full-scale IX column testing conducted as part of the technology maturation plan. The experimental approaches used at PNNL in these four technical areas are summarized and selected key preliminary results are provided. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Challenging Common Assumptions of Thick-Wall Chamber Dynamics in Inertial Fusion Systems using MOOSE

As an increasing number of companies look toward commercial Inertial Fusion Energy (IFE) designs, there is a pressing need to understand the physics of thick-wall chamber gas dynamics. The thick liquid wall approach implements a renewable wall to mitigate the fusion target emissions, thereby reducing the radiation damage rate and significantly extending the lifetime of chamber structures, leading to increased plant availability and reduced waste streams in comparison to dry wall chamber designs. It is necessary, however, to assess the critical performance and safety aspects of these systems. For example, it is crucial to predict (1) where the mass ablated from the liquid walls will vent, which determines the placement of condensing surfaces; (2) debris propagation up the beam lines, which provides essential information for design and protection requirements; (3) peak pressures and impulse on chamber walls, which affect chamber structural design; and (4) momentum transfer to the liquid jets, which constrains the shape and positioning of the jets. In turn, the chamber design and its liquid walls affect shielding requirements, material activation, and tritium fuel cycle. Currently available simulation tools, however, are unable to accurately capture key thick-wall chamber dynamics. Significant assumptions are often made to simplify the system and reduce computational cost and modeling capability needs, but the impact of these assumptions on simulation predictions has not been evaluated. For example, no three-dimensional simulations can be found in the open literature to evaluate gas venting and momentum transfer to the jets with simulations using two-dimensional domains to represent complex three-dimensional geometries. Moreover, limited studies have been dedicated to jet breakup due to both turbulence and neutron heating, and no studies have been found that evaluate how jet breakup can impact shock-jet interaction. Furthermore, effects of radiative heat transfer have rarely been included for the hydrodynamic phase of shock propagation, and integration of proper equations of state in shock dynamics codes has been mostly exploratory. In this study, we use the flexible, high-fidelity Multiphysics Object-Oriented Simulation Environment (MOOSE) to model these complex phenomena and inform design and safety studies. Capabilities to model thick-wall chamber gas dynamics are being developed, and the impact of the assumptions listed above (i.e., two-dimensional vs three-dimensional, absence of jet breakout, no radiative heat transfer, and ideal gas behavior) are being quantified.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Challenging Common Assumptions of Thick-Wall Chamber Dynamics in Inertial Fusion Systems Using MOOSE-based Multiphysics Simulations

As an increasing number of companies look toward commercial Inertial Fusion Energy (IFE) designs, there is a pressing need to understand the physics of thick-wall chamber gas dynamics. The thick liquid wall approach implements a renewable wall to mitigate the fusion target emissions, thereby reducing the radiation damage rate and significantly extending the lifetime of chamber structures, leading to increased plant availability and reduced waste streams in comparison to dry wall chamber designs. It is necessary, however, to assess the critical performance and safety aspects of these systems. For example, it is crucial to predict (1) where the mass ablated from the liquid walls will vent, which determines the placement of condensing surfaces; (2) debris propagation up the beam lines, which provides essential information for design and protection requirements; (3) peak pressures and impulse on chamber walls, which affect chamber structural design; and (4) momentum transfer to the liquid jets, which constrains the shape and positioning of the jets. In turn, the chamber design and its liquid walls affect shielding requirements, material activation, and tritium fuel cycle. Currently available simulation tools, however, are unable to accurately capture key thick-wall chamber dynamics. Significant assumptions are often made to simplify the system and reduce computational cost and modeling capability needs, but the impact of these assumptions on simulation predictions has not been evaluated. For example, no three-dimensional simulations can be found in the open literature to evaluate gas venting and momentum transfer to the jets with simulations using two-dimensional domains to represent complex three-dimensional geometries. Moreover, limited studies have been dedicated to jet breakup due to both turbulence and neutron heating, and no studies have been found that evaluate how jet breakup can impact shock-jet interaction. Furthermore, effects of radiative heat transfer have rarely been included for the hydrodynamic phase of shock propagation, and integration of proper equations of state in shock dynamics codes has been mostly exploratory. In this study, we use the flexible, high-fidelity Multiphysics Object-Oriented Simulation Environment (MOOSE) to model these complex phenomena and inform design and safety studies. Capabilities to model thick-wall chamber gas dynamics are being developed, and the impact of the assumptions listed above (i.e., two-dimensional vs three-dimensional, absence of jet breakout, no radiative heat transfer, and ideal gas behavior) are being quantified.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Automation and Use of Robotics for Decommissioning Tasks - 18322

Decommissioning across the globe is being executed largely by manual labor. The Organization for Economic Co-operation and Development (OECD) has concluded that the nuclear industry has not fully exploited or implemented current technological capabilities, and relies on sometimes outdated technology to perform decommissioning tasks [1]. To address this issue, EPRI recently published the report Evaluation of System Automation and Robotics for Decommissioning Applications (EPRI 3002010599) [2]. To facilitate wide usage of the guidance by technology developers, the report is publicly available at no cost. The use of more efficient and effective decommissioning technologies and processes could reduce the decommissioning project schedule and therefore reduce the period-dependent costs incurred throughout the decommissioning project. Such systems may also offer a substantial benefit with respect to worker safety and radiation exposure reduction. However, tasks for which use of such systems is beneficial must be carefully considered, being robust and generally trouble free to operate in the demanding environment of commercial power plant decommissioning. A review of the major tasks involved in the decommissioning of a nuclear power plant is presented, with a critical assessment of the benefits for the use of robotics and/or automation. Recommendations for areas of future research and development are identified. The results of this project will be beneficial to global organizations working on development of engineered systems for decommissioning applications by providing a focus on priority tasks. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of In-Situation Radioactivity Inspection System for Food Materials

The impacts on the ocean of releases of radionuclides from the Fukushima nuclear power plants remain unclear. Korean people worry about radioactive contamination of Japanese and Korean sea products. Radioactive contamination of processed foodstuffs, livestock, sea products, farm products imported from Japan and fishes caught in coastal oceans of Korea has become an important social issue. Recently, there are also needs of inspection system for monitoring of public meals such like school feedings of kindergarten, elementary/middle/high school and university. Radioactivity inspections of food materials have been executed manually with portable measuring instruments or at labs using their samples. But, it's very important the radioactivity inspection should be performed at the field of feeding facilities. To protect the health of people from radioactivity contained in Japanese marine products imported to Korea, a system to inspect radioactivity in real time has been developed. The system is to measure the radioactivity level of farm and marine products and public meals continuously and automatically at inspection sites of an agency checking radiation of imported foodstuffs or school. The performance test of NaI(Tl) detector was examined using the quantified Cs-137 source 10 Bq/kg, 30 Bq/kg, 50 Bq/kg, 300 Bq/kg and 900 Bq/kg at Korea Research Institute of Standards and Science(KRISS). Source was put in a box and radioactivity was measured in the middle of the box. First of all, Background was measured and calibration was performed using the Cs-137 300 Bq and Ba-133 3700 Bq for 60 minutes. After setting the background and calibration data, tests of the Cs-137 10, 30, 50, 300, 900 Bq/kg were executed for 10 minutes. A peak-shaped graph is shown at the location of 662 KeV (80∼100 channel). This is due to the gamma radiation energy with 662 KeV emitted by the Cs-137. Because through KRISS examination, the MDA (minimum detectable activity) is about 23 Bq/kg, it is reasonable Cs-137 10 Bq/kg cannot be measured. And in cases of Cs-137 300 Bq/kg and 900 Bq/kg, there are some peak movement on the graph. It can be adjusted by controlling gain or high voltage. The examination was identified through the performance test (Cs-137 10, 30, 50, 300, 900 Bq/kg) at KRISS. In order to increase the measurement efficiency of Cs-137 and the system performance, database will be built up based on radioactivity measurement results from 10 to 300 Bq/kg with the unit 10. Thus, Cs-137 concentration of food materials can be identified below the maximum permissible concentration of 100 Bq/kg on a basis of the spectrum characteristic of Cs-137. Also, anxiety about radioactive contamination of foods after the Fukushima nuclear accident will be eased and trust of the radioactive inspection is expected definitely. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sulforaphane protects Microcystin-LR-induced toxicity through activation of the Nrf2-mediated defensive response

Microcystins (MCs), a cyclic heptapeptide hepatotoxins, are mainly produced by the bloom-forming cyanobacerium Microcystis, which has become an environmental hazard worldwide. Long term consumption of MC-contaminated water may induce liver damage, liver cancer, and even human death. Therefore, in addition to removal of MCs in drinking water, novel strategies that prevent health damages are urgently needed. Sulforaphane (SFN), a natural-occurring isothiocyanate from cruciferous vegetables, has been reported to reduce and eliminate toxicities from xenobiotics and carcinogens. The purpose of the present study was to provide mechanistic insights into the SFN-induced antioxidative defense system against MC-LR-induced cytotoxicity. We performed cell viability assays, including MTS assay, colony formation assay and apoptotic cell sorting, to study MC-LR-induced cellular damage and the protective effects by SFN. The results showed that SFN protected MC-LR-induced damages at a nontoxic and physiological relevant dose in HepG2, BRL-3A and NIH 3 T3 cells. The protection was Nrf2-mediated as evident by transactivation of Nrf2 and activation of its downstream genes, including NQO1 and HO-1, and elevated intracellular GSH level. Results of our studies indicate that pretreatment of cells with 10 {mu}M SFN for 12 h significantly protected cells from MC-LR-induced damage. SFN-induced protective response was mediated through Nrf2 pathway.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Toward biologically inspired self healing digital embedded devices: BIO-SymPle - 388

One of the more interesting concepts being postulated for next gen power plants, is the notion of highly resilient and survivable I and C systems. While resilience and survivability are 'cross system attributes', resilience and robustness will rely on highly robust and fault resilient devices as a foundation. This paper presents a new self-healing digital I and C architecture inspired by the operation of two biological concepts: human immune system and embryonic stem cells. The purpose of this research is look at different bio-inspired paradigms for organizing system functions so that they become inherently resilient due to device organization and behaviors. Our current proposed approach (called BIO-SymPle) is organized in two levels: critical service layer, which is providing the intended service of critical application, and healing layer, that supervises the operation of all repair mechanisms. To facilitate coordination, organized behavior among cells we employ network-based topology structures which is comprised of four active cells, four pre-generated redundant cells, and one embryonic stem cell. Collectively, the ensemble represents the building block that executes the local functionality based on the expression for DNA genetic codes stored inside each cell. The four bio-operational active cells are protected by their neighboring spare cells that imitate how white blood cells are distributed around the antigens in their locations. Ultimately, the proposed multi-layer architecture is able to cover a significant number of coincident faults and we believe architectures like BIO-SymPLe can positively impact the next generation digital I and C system. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Qualified display system architecture - 246

There is a need in the nuclear industry for a Qualified Display System (QDS) architecture as described in this paper. The function of the QDS is to process and display Regulatory Guide 1.97 post accident monitoring parameters. The QDS is implemented on the Lockheed Martin Field-Programmable Gate Array (FPGA) based Nuclear Protection and Control (NuPAC) digital platform, coupled with a Qualified Display Controller (QDC) and a Safety Display Unit (SDU). The QDS is designed to meet the requirements of IEEE 603-1991 (endorsed by Regulatory Guide 1.153, Rev. 1), IEEE 497-2002 (endorsed by Regulatory Guide 1.97, Rev. 4), and IEEE 7-4.3.2- 2003 (endorsed by Regulatory Guide 1.152, Rev. 3). The QDS is designed with flexibility such that it can be implemented in an advanced reactor design, Small Modular Reactor (SMR) with any cooling medium, or digital upgrade project for an operating nuclear plant. The QDS has four independent and redundant divisions. Each division has five layers in the architecture: Process variable input signals; Process Protection Logic (PPL); Algorithm Logic (AL), Interface Panel (IP); and Safety Display Unit (SDU). The QDS meets the following design criteria: redundancy, independence, predictability and repeatability, and diversity capability. The QDS architecture also meets the simplicity design principle. The QDS architecture design provides flexibility in the implementation in a plant. The QDS can be implemented in the design of a new advanced plant or as a digital upgrade in an operating plant. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Habitat Restoration/Enhancement Fort Hall Reservation : 2008 Annual Report.

Habitat enhancement, protection and monitoring were the focus of the Resident Fisheries Program during 2008. Enhancement and protection included sloping, fencing and planting wetlands plugs at sites on Spring Creek (Head-waters). Many previously constructed instream structures (rock barbs and wing dams) were repaired throughout the Fort Hall Indian Reservation (Reservation). Physical sampling during 2008 included sediment and depth measurements (SADMS) in Spring Creek at the Car Removal site. SADMS, used to track changes in channel morphology and specifically track movements of silt through Bottoms stream systems were completed for 5 strata on Spring Creek. Water temperature and chemistry were monitored monthly on Spring Creek, Clear Creek, Diggie Creek, and Portneuf (Jimmy Drinks) and Blackfoot rivers. Fish population densities and biomass were sampled in five reservation streams which included nine sites. Sampling protocols were identical to methods used in past years. Numbers of fish in Spring Creek series remained relatively low, however, there was an increase of biomass overall since 1993. Salmonid fry densities were monitored near Broncho Bridge and were similar to 2006, and 2007, however, as in years past, high densities of macrophytes make it very difficult to see fry in addition to lack of field technicians. Mean catch rate by anglers on Bottoms streams stayed the same as 2007 at 1.5/hr. Numbers of fish larger than 18-inches caught by anglers increased from 2007 at .20 to .26/hr.

13 HYDRO ENERGY↗

Control Augmented Structural Synthesis

A methodology for control augmented structural synthesis is proposed for a class of structures which can be modeled as an assemblage of frame and/or truss elements. It is assumed that both the plant (structure) and the active control system dynamics can be adequately represented with a linear model. The structural sizing variables, active control system feedback gains and nonstructural lumped masses are treated simultaneously as independent design variables. Design constraints are imposed on static and dynamic displacements, static stresses, actuator forces and natural frequencies to ensure acceptable system behavior. Multiple static and dynamic loading conditions are considered. Side constraints imposed on the design variables protect against the generation of unrealizable designs. While the proposed approach is fundamentally more general, here the methodology is developed and demonstrated for the case where: (1) the dynamic loading is harmonic and thus the steady state response is of primary interest; (2) direct output feedback is used for the control system model; and (3) the actuators and sensors are collocated.

Lust, Robert V.↗

Project Columbiad: Mission to the Moon. Book 1: Executive Summary. Volume 1: Mission trade studies and requirements. Volume 2: Subsystem trade studies and selection

In response to the Report of the Advisory Committee on the future of the U.S. Space Program and a request from NASA's Exploration Office, the MIT Hunsaker Aerospace Corporation (HAC) conducted a feasibility study, known as Project Columbiad, on reestablishing human presence on the Moon before the year 2000. The mission criteria established were to transport a four person crew to the lunar surface at any latitude and back to Earth with a 14-28 day stay on the lunar surface. Safety followed by cost of the Columbiad Mission were the top level priorities of HAC. The resulting design has a precursor mission that emplaces the required surface payloads before the piloted mission arrives. Both the precursor and piloted missions require two National Launch System (NLS) launches. Both the precursor and piloted mission have an Earth orbit rendezvous (EOR) with a direct transit to the Moon post-EOR. The piloted mission returns to Earth via a direct transit. Included among the surface payloads preemplaced are a habitat, solar power plant (including fuel cells for the lunar night), lunar rover, and mechanisms used to cover the habitat with regolith (lunar soil) in order to protect the crew members from severe solar flare radiation.

Clarke, Michael↗

Project Columbiad: Reestablishment of human presence on the Moon

In response to the Report of the Advisory Committee on the future of the U.S. Space Program and a request from NASA's Exploration Office, the MIT Hunsaker Aerospace Corporation (HAC) conducted a feasibility study, known as Project Columbiad, on reestablishing human presence on the Moon before the year 2000. The mission criteria established were to transport a four person crew to the lunar surface at any latitude and back to Earth with a 14-28 day stay on the lunar surface. Safety followed by cost of the Columbiad Mission were the top level priorities of HAC. The resulting design has a precursor mission that emplaces the required surface payloads before the piloted mission arrives. Both the precursor and piloted missions require two National Launch System (NLS) launches. Both the precursor and piloted missions have an Earth orbit rendezvous (EOR) with a direct transit to the Moon post-EOR. The piloted mission returns to Earth via a direct transit. Included among the surface payloads preemplaced are a habitat, solar power plant (including fuel cells for the lunar night), lunar rover, and mecanisms used to cover the habitat with regolith (lunar soil) in order to protect the crew members from severe solar flare radiation.

Shea, Joseph↗

Mitigation and Use of Biofilms in Space for the Benefit of Human Space Exploration

Biofilms are groups of cells of the same or different species living in communities. Such structures are usually attached to surfaces, and on Earth, they have been found in diverse and extreme environments. Such agglomerations have been described as recalcitrant or protective when facing adversity. In space systems, biofilms have been found on a multitude of hardware surfaces. Different studies have identified genetic changes that may impact human health. The insufficiency of consistent research may return inconclusive arguments as to what extent microgravity encourages virulence and how biofilms could exacerbate crewed spaceflight–especially ones to remote areas with a lack of resupply and service missions. However, biofilms are also beneficial to plant biology, and they may supply in metabolic pathways that produce useful organic and inorganic components to maintain life in other celestial bodies. There are expansive areas of research that look into biofilms in space and scientific recommendations that reflect on expanding the aerospace industry’s knowledge of biofilms, how to mitigate, or use them to the advantage of spaceflight.

Yo-ann Velez Justiniano↗

CERF: IM3 Projected Western US Power Plant Locations

Overview The Capacity Expansion Regional Feasibility (CERF) model is an open-source geospatial python package that provides new power plant locations at a 1km resolution. The model ingests U.S. state or regional-scale electricity system capacity expansion plans, such as those produced by the Global Change Analysis Model (GCAM-USA), and identifies feasible, site-specific locations for individual new power plants (renewable and non-renewable). CERF combines high-resolution geospatial suitability analyses with an economic algorithm that selects individual plant siting locations based on grid interconnection costs and the locational marginal value of new generation. The model incorporates a wide range of dynamic constraints and opportunities, such as protected lands, population density, existing infrastructure, and water availability. This dataset provides CERF power plant siting results for IM3 Phase 2 simulations across eight different scenarios for the Western US through 2055. The scenarios include combinations of two Shared Socioeconomic Pathways (SSP3 and SSP5) with four high-resolution climate projections specific to the United States (see, https://tgw-data.msdlive.org/). These climate projections include "hotter" and "cooler" variants for two Representative Concentration Pathways (RCP4.5 and RCP8.5). The resulting eight simulations are: rcp45cooler_ssp3 rcp45cooler_ssp5 rcp45hotter_ssp3 rcp45hotter_ssp5 rcp85cooler_ssp3 rcp85cooler_ssp5 rcp85hotter_ssp3 rcp85hotter_ssp5 CERF siting results in this dataset correspond to capacity expansion plans in the GCAM-USA IM3 Phase 2 simulation data and are available for each of the above scenarios. Data Details Temporal Range: 2015-2055 in 5-year timesteps. Note that 2015 is the experiment base year and 2020 and beyond represent model simulation years. Spatial Range: Plant locations are provided for the eleven states in the Western US including Arizona, California, Colorado, Idaho, Montana, New Mexico, Nevada, Oregon, Utah, Washington, and Wyoming. Spatial Resolution: 1 km-squared, provided in x and y coordinates Geospatial Projection: Albers Equal Area Conic (ESRI:102003) File Type: csv The dataset contains subdirectories for each of the eight scenarios described in the overview. Each scenario folder contains two subfolders with the following information: 1. Power Plant Data This directory contains a single .csv file of power plant locations for both pre-existing (non-CERF sited plants in operation in 2015) and new (CERF-sited) power plants across the temporal range along with additional CERF model output parameters for CERF-sited plants. Plant with a siting year earlier than 2020 correspond to facilities that are operational leading into the first timestep CERF simulation. For a more detailed description of CERF model output parameters, see the CERF model documentation. Note that the cerf_plant_id parameter is unique within each scenario file but not across scenario files. Parameter Descriptions scenario - Name of scenario cerf_plant_id - Unique siting identifier cerf_sited - If True, indicates that plant was sited by CERF model. If False, indicates pre-existing facility region_name - Name of region (state) tech_id - Technology ID tech_name - Full generation technology name inclusive of cooling type (if applicable) and additional characteristics tech_simple - Simplified generation technology type unit_size_mw - Power plant unit size (MW) xcoord - X coordinate in the default CRS (meters) ycoord - Y coordinate in the default CRS (meters) index - Index position in the flattend 2D array buffer_in_km - Exclusion buffer around site (km) sited_year - Year of siting retirement_year - Year of retirement lmp_zone - Locational marginal price (LMP) zone ID locational_marginal_price_usd_per_mwh - Locational marginal price ($/MWh) generation_mwh_per_year - Generation output (MWh/yr) operating_cost_usd_per_year - Cost of plant operations ($/yr) net_operational_value - Net operational value based on LMP and and operating costs ($/yr) interconnection_cost - Cost of interconnection for transmission & gas pipeline (if applicable) net_locational_cost -- Difference of interconnection cost and operating value ($/yr) capacity_factor_fraction - Capacity factor (fraction) carbon_capture_rate_fraction - Carbon capture rate (fraction) fuel_co2_content_tons_per_btu - Fuel CO2 content (tons/Btu) fuel_price_usd_per_mmbtu - Fuel price ($/MMBtu) fuel_price_esc_rate_fraction - Fuel price escalation rate (fraction) heat_rate_btu_per_kWh - Heat rate (Btu/kWh) lifetime_yrs - Technology lifetime for annuity (years) operational_life_yrs - Operational lifetime for retirement (years) variable_om_usd_per_mwh - Variable operation and maintenance costs of yearly capacity use ($/MWh) variable_om_esc_rate_fraction - Variable operation and maintenance costs escalation rate (fraction) carbon_tax_usd_per_ton - Carbon tax ($/ton) carbon_tax_esc_rate_fraction - Carbon tax escalation rate (fraction) 2. Storage Data This directory contains information on new and pre-existing energy storage facilities operational in each timestep along with various storage operational parameters. The 2015 timestep provides pre-existing energy storage data and corresponds with facilities that are operational leading into the first model simulation timestep. Note that coordinates in the storage files correspond to the interconnection point on the grid (substation location), not individual energy storage locations. Energy storage is added in a cumulative process at each given interconnection point. That is, each individual file provides the total operational storage capacity interconnected to the specified substation for the given timestep, inclusive of previously installed storage at that location and new storage installed in that timestep at that location. Parameters scenario - Name of scenario timestep - Simulation timestep name - Unique storage identifier s_typ - Type of energy storage technology (battery or pumped storage hydro) s_node - Node ID of interconnecting substation xcoord - X coordinate in the default CRS (meters) ycoord - Y coordinate in the default CRS (meters) charge_rate - Maximum charge rate (power capacity) of storage system (MW) discharge_rate - Maximum discharge rate (power capacity) of storage system (MW) duration - Duration of storage system (hours) max_SoC - Allowed maximum state of charge (energy capacity) of storage system (MWh) min_SoC -Allowed minimum state of charge (energy capacity) of storage system (MWh) charge_eff - Efficiency of charge (fraction between 0 and 1) discharge_eff - Efficiency of discharge (fraction between 0 and 1) Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program.

CERF↗

Assessment on Transport of Radioactive Species from Nuclear Facilities - 17079

It is generally recognized that radioactive nuclides are most hazardous fission products that could be released in the event of reactor accidents. The reactor coolant system of a pressurized water reactor (PWR) nuclear plant exhibits radioactivity from various sources. These radiation sources consist of the fission products from fuel element and activated products from corrosion products. The complex infrastructure of the processes does not allow detailed measurement of activity until after the reactor is shutdown. All of the components that require dismantling will be radioactive which was caused by neutron activation during operation, contamination by corrosion products, contamination by damaged by fuel rods and leaks by equipment. Due mainly to the various operation modes and their aging, there are the increasing needs to carry out repair works that are not sufficiently provided for by the original design. Many difficulties are involved in these tasks, namely, high radiation doses, cramped areas, hard to reach components, coupled with stringent quality conditions. The need to simulate the behavior of corrosion products in a nuclear power plant environment has attracted many researchers' attention. It has performed the in-depth reviews of the various theories and physics associated with the corrosion products transportation, the laboratory loop testing, and the field measurements in operating plants. Before we start the decommissioning of nuclear power plants, workers, the public and the environment shall be properly protected from radiation hazards. For this purpose, a safety assessment should be carried out relating to the potential hazards that may occur during the decommissioning. The radiological hazards involved in the decommissioning activities also should be identified, and be taken into account in the safety assessment. The radiation conditions of the primary circuit are determined by the activity of corrosion and fission products that have accumulated on the internal surfaces of the components. Therefore the estimation of contamination on the components is very important and, may be the first step in the reactor operation and decommissioning of components. The predominant radionuclide in the PWR primary coolant is Co-60, although Co-58 contributes significantly to radioactivity level at the early stage of a reactor operation. Since Co-60 is produced from the in-core Co-58, which is the source of cobalt in a reactor coolant system, many researchers have investigated its transmutation in the core, its transport around the system, and its subsequent deposition on surfaces. The major parameter influencing the behavior of radioactivity, such as Co-60 in the coolant, is the corrosion product oxides. The objective of this work is to analyze the corrosion product activity transported in the primary circuit by using a multi-region model. This model, which is incorporated with the mass and activity transport between the dissolved corrosion products in the coolant and the surface, describes the specific activity of corrosion products in coolant and on the surfaces according to the operation modes as well as decommissioning stage. In order to evaluate the analysis of the corrosion products in an integral type reactor, a multi-region mass balance model is applied. The specific activities of the various species on the surface of core and steam generator throughout the effective full power hours, 15,000 hours, are simulated for the various modes of operations. As a result, the specific activities of corrosion products from the surface of primary circuit were shown as very low compared to those of other commercial nuclear power plants. In this simulated reactor, a significant reduction of specific activities from the activated corrosion products is obtained due to the introduction of titanium alloy to the steam generator tube and the avoidance of boric acid induced corrosion. From this result we conclude that we are able to predict the level of radioactive nuclides generated by corrosion products in a primary circuit according to the various modes of operations by using multi-region model. In this point of view it is concluded that this multi-region model can be used as an engineering tool for analysis of the corrosion products within the primary coolant for the nuclear power plants. It is also considered that it is possible to extend to a calculation tool for estimating the radiological hazards involved in the decommissioning activities in terms of safety assessment. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Safety assessment of personal care products/cosmetics and their ingredients

We attempt to review the safety assessment of personal care products (PCP) and ingredients that are representative and pose complex safety issues. PCP are generally applied to human skin and mainly produce local exposure, although skin penetration or use in the oral cavity, on the face, lips, eyes and mucosa may also produce human systemic exposure. In the EU, US and Japan, the safety of PCP is regulated under cosmetic and/or drug regulations. Oxidative hair dyes contain arylamines, the most chemically reactive ingredients of PCP. Although arylamines have an allergic potential, taking into account the high number of consumers exposed, the incidence and prevalence of hair dye allergy appears to be low and stable. A recent (2001) epidemiology study suggested an association of oxidative hair dye use and increased bladder cancer risk in consumers, although this was not confirmed by subsequent or previous epidemiologic investigations. The results of genetic toxicity, carcinogenicity and reproductive toxicity studies suggest that modern hair dyes and their ingredients pose no genotoxic, carcinogenic or reproductive risk. Recent reports suggest that arylamines contained in oxidative hair dyes are N-acetylated in human or mammalian skin resulting in systemic exposure to traces of detoxified, i.e. non-genotoxic, metabolites, whereas human hepatocytes were unable to transform hair dye arylamines to potentially carcinogenic metabolites. An expert panel of the International Agency on Research of Cancer (IARC) concluded that there is no evidence for a causal association of hair dye exposure with an elevated cancer risk in consumers. Ultraviolet filters have important benefits by protecting the consumer against adverse effects of UV radiation; these substances undergo a stringent safety evaluation under current international regulations prior to their marketing. Concerns were also raised about the safety of solid nanoparticles in PCP, mainly TiO{sub 2} and ZnO in sunscreens. However, current evidence suggests that these particles are non-toxic, do not penetrate into or through normal or compromised human skin and, therefore, pose no risk to human health. The increasing use of natural plant ingredients in personal care products raised new safety issues that require novel approaches to their safety evaluation similar to those of plant-derived food ingredients. For example, the Threshold of Toxicological Concern (TTC) is a promising tool to assess the safety of substances present at trace levels as well as minor ingredients of plant-derived substances. The potential human systemic exposure to PCP ingredients is increasingly estimated on the basis of in vitro skin penetration data. However, new evidence suggests that the in vitro test may overestimate human systemic exposure to PCP ingredients due to the absence of metabolism in cadaver skin or misclassification of skin residues that, in vivo, remain in the stratum corneum or hair follicle openings, i.e. outside the living skin. Overall, today's safety assessment of PCP and their ingredients is not only based on science, but also on their respective regulatory status as well as other issues, such as the ethics of animal testing. Nevertheless, the record shows that today's PCP are safe and offer multiple benefits to quality of life and health of the consumer. In the interest of all stakeholders, consumers, regulatory bodies and producers, there is an urgent need for an international harmonization on the status and safety requirements of these products and their ingredients.

60 APPLIED LIFE SCIENCES↗

Impacts of Soil Microbiome Variations on Root Colonization by Fungi and Bacteria and on the Metabolome of Populus tremula × alba

Trees depend on beneficial interactions between roots and soil microbes for their nutrition and protection against stresses. The soil microbiome provides the main reservoir of microbes for root colonization and is subject to natural variations that can affect its composition. It is not clear whether the tree’s root system is able to buffer the natural variations occurring in the soil microbiome to capture a stable and effective microbiome or whether these variations affect its microbiome to impact its physiology. To address this question, we planted cuttings of Gray Poplar (Populus tremula × alba clone 717-1B4) in natural soil taken from a poplar stand under the same tree over two consecutive years and grew them in a greenhouse. We analyzed the soil and root microbiomes by high throughput Illumina MiSeq sequencing of fungal rDNA internal transcribed spacer and bacterial 16S rRNA amplicons and we characterized the root metabolome by gas chromatography-mass spectrometry. Soil and root microbial communities significantly shifted over the 2 years. A modification of the balance between endophytes, saprophytes, and mycorrhizal fungi occurred in the roots as well as a replacement of some dominant operational taxonomic units by others. These modifications were correlated with a significant alteration of the levels of about 10% of primary and secondary metabolites, suggesting that natural fluctuations in soil microbial communities can have a profound impact on tree root metabolism and physiology. Tree roots functioning may thus be indirectly strongly affected by the effects of future extreme climatic variations on the soil microbiome.

59 BASIC BIOLOGICAL SCIENCES↗

Next Generation Melter Testing for High Aluminum HLW Glasses (Final Report)

This Final Report describes the initial DuraMelter 100 (DM100) scale testing performed to support the development of next generation advanced joule-heated melters (NG AJHMs). The initial phase of testing investigated the impacts of plenum heaters and the partial drying of melter feed prior to its introduction into the melter. The tests demonstrate the overall impacts and benefits on processing characteristics such as increases in waste processing and glass production rates, and component volatility. The results also provide melting rates for sizing calculations and compatibility of feed and off-gas treatment systems. The tests were performed with a Hanford high level waste (HLW) composition previously processed on both the DM100 melter and the HLW Pilot Melter (DM1200). The simulated waste containing a high concentration of aluminum was originally specified by the Office of River Protection (ORP) for testing at VSL. This waste composition is representative of high-aluminum feeds that will be processed at the Hanford Tank Waste Treatment and Immobilization Plant (WTP) and that are expected to challenge waste loading and processing rate objectives. This works builds upon previous work performed at the Vitreous State Laboratory (VSL) of the Catholic University of America (CUA) for ORP to increase waste loadings and waste processing rates for high aluminum HLW waste streams by glass formulation optimization, bubbling, and modest increases in melt temperature. The present tests were conducted in response to the Task Plan WP-4.1.4.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗