At least 541 records · Page 30

Big Data and Deep data in scanning and electron microscopies: functionality from multidimensional data sets

The development of electron, and scanning probe microscopies in the second half of the twentieth century have produced spectacular images of internal structure and composition of matter with, at nanometer, molecular, and atomic resolution. Largely, this progress was enabled by computer-assisted methods of microscope operation, data acquisition and analysis. The progress in imaging technologies in the beginning of the twenty first century has opened the proverbial floodgates of high-veracity information on structure and functionality. High resolution imaging now allows information on atomic positions with picometer precision, allowing for quantitative measurements of individual bond length and angles. Functional imaging often leads to multidimensional data sets containing partial or full information on properties of interest, acquired as a function of multiple parameters (time, temperature, or other external stimuli). Here, we review several recent applications of the big and deep data analysis methods to visualize, compress, and translate this data into physically and chemically relevant information from imaging data.

36 MATERIALS SCIENCE↗

Final Report, Fundamental Mechanisms of Transient States in Materials Quantified by DTEM

At the project’s inception, there was growing evidence that the time domain for in situ observations of material evolution held great promise for allowing measurements to be made in never previously contemplated regimes. Also, central to the development of the project was the knowledge that phase transformations are of central importance to the development of materials microstructure and hence properties. We addressed this opportunity by developing a transmission electron microscope that could be operated in the pulsed mode (DTEM), with exposure times down to 20 ns and interframe times down to 20 ns in the nine-frame movie mode, designed with the intent of performing in situ experiments. This unprecedented capability allowed us to investigate structural phase transformations, intermetallic formation reactions, crystallization from the amorphous phase, rapid solidification of liquid metals, transformations in phase change materials, and catalyst nanoparticles. The ability of the electron microscope to create images with high spatial resolution allows for the accurate measurement of position. Common to all of the transformations mentioned above is the presence of a distinct interface between the old phase and the growing new phase. Measuring the position of the interface as a function of time, combined with the ability to count nucleation sites as a function of time, allowed for the exceptionally accurate measure of transformation kinetics. These measurements were used to guide and constrain the development of models and simulation methods for the classes of transformations studied.

36 MATERIALS SCIENCE↗

Particle Mass Flow Control for High-Temperature Concentrating Solar Receivers

This report summarizes the results of a two-year project funded by the U.S. Department of Energy's Solar Energy Technologies Office (SuNLaMP 1506) to evaluate the performance of high-temperature (>700 °C) particle receivers for concentrating solar power (see Appendix A for project information). In the first year, novel particle release patterns were designed and tested to increase the effective solar absorptance of the particle curtain. Modeling results showed that increasing the magnitude and frequency of different wave-like patterns increased the effective absorptance and thermal efficiency by several percentage points, depending on the mass flow rate. Tests showed that triangular-wave, square-wave, and parallel-curtain particle release patterns could be implemented and maintained at flow rates of ~10 kg/s/m. The second year of the project focused on the development and testing of particle mass-flow control and measurement methods. An automated slide gate controlled by the outlet temperature of the particles was designed and tested. Testing demonstrated that the resolution accuracy of the slide-gate positioning was less than ~1 mm, and the speed of the slide gate enabled rapid adjustments to accommodate changes in the irradiance to maintain a desired outlet temperature range. Different in-situ particle mass-flow measurement techniques were investigated, and two were tested. The in-situ microwave sensor was found to be unreliable and sensitive to variations in particle flow patterns. However, the in-situ weigh hopper using load cells was found to provide reliable and repeatable measurements of real-time in-situ particle mass flow. On-sun tests were performed to determine the thermal efficiency of the receiver as a function of mass flow rate, particle temperature, and irradiance. Models of the tests were also developed and compared to the tests.

14 SOLAR ENERGY↗

DISTINGUISHING A HYPOTHETICAL ABIOTIC PLANET–MOON SYSTEM FROM A SINGLE INHABITED PLANET

It has recently been suggested that an exomoon with a CH{sub 4} atmosphere, orbiting an abiotic Earth-mass planet with an O{sub 2}-rich atmosphere, can produce a false positive biosignature at a low–moderate spectral resolution (R = λ/Δλ ≤ 2000). If this were true, inferring the presence of life on exoplanets will be beyond our reach in the next several decades. Here we use a line-by-line radiative transfer model to compute the relevant reflection spectrum between 1 and 3.3 μm. We show that it is possible to separate the combined spectra of such planet–moon systems from an inhabited planet by multiple-band NIR observations. We suggest that future observations near the 2.3 μm CH{sub 4} absorption band at a resolution of 100 and an SNR of 10 or more may be a good way to distinguish an abiotic planet–moon system from a inhabited single planet.

79 ASTRONOMY AND ASTROPHYSICS↗

C$^{7}$LYC: A New Scintillator for Fast Neutron Spectroscopy

The scintillator Cs 2 LiYCl 6 (CLYC) has emerged as a versatile detector for both gammas and neutrons, with excellent pulse shape discrimination. Originally developed as a thermal neutron counter, the discovery of its unexpected and unprecedented ~10% pulse height resolution for fast neutrons in the few MeV range has prompted studies to benchmark its use in low-energy nuclear science and applications. Since the typical long time-of-flight arms are not needed for achieving good energy resolution, geometrical efficiency can be enhanced by positioning the detectors much closer to the target. We have constructed a 16-element array of 1” × 1”7Li-enriched C 7 LYC, to eliminate the dominant peak in the spectrum from thermal neutron capture on 6Li, leaving the energy region above 3 MeV with a clean baseline for fast neutron spectroscopy. We have also procured the first ever 3” × 3” C 7 LYC crystal. Test experiments under way with C 7 LYC include elastic and inelastic neutron scattering cross sections at Los Alamos with a pulsed white neutron source, efficiency measurements using mono-energetic neutron beams up to a few MeV at UMass Lowell, and fission neutron measurements with GRETINA and CHICO detector arrays at Argonne. Beta-delayed neutron spectroscopy experiments have also been initiated at the CARIBU and NSCL facilities, to evaluate C 7 LYC as a possible candidate for auxiliary scintillator arrays for stopped beam physics at the next generation rare isotope accelerators.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An Application of Multi-band Forced Photometry to One Square Degree of SERVS: Accurate Photometric Redshifts and Implications for Future Science

We apply The Tractor image modeling code to improve upon existing multi-band photometry for the Spitzer Extragalactic Representative Volume Survey (SERVS). SERVS consists of post-cryogenic Spitzer observations at 3.6 and 4.5 μ m over five well-studied deep fields spanning 18 deg{sup 2}. In concert with data from ground-based near-infrared (NIR) and optical surveys, SERVS aims to provide a census of the properties of massive galaxies out to z ≈ 5. To accomplish this, we are using The Tractor to perform “forced photometry.” This technique employs prior measurements of source positions and surface brightness profiles from a high-resolution fiducial band from the VISTA Deep Extragalactic Observations survey to model and fit the fluxes at lower-resolution bands. We discuss our implementation of The Tractor over a square-degree test region within the XMM Large Scale Structure field with deep imaging in 12 NIR/optical bands. Our new multi-band source catalogs offer a number of advantages over traditional position-matched catalogs, including (1) consistent source cross-identification between bands, (2) de-blending of sources that are clearly resolved in the fiducial band but blended in the lower resolution SERVS data, (3) a higher source detection fraction in each band, (4) a larger number of candidate galaxies in the redshift range 5 < z < 6, and (5) a statistically significant improvement in the photometric redshift accuracy as evidenced by the significant decrease in the fraction of outliers compared to spectroscopic redshifts. Thus, forced photometry using The Tractor offers a means of improving the accuracy of multi-band extragalactic surveys designed for galaxy evolution studies. We will extend our application of this technique to the full SERVS footprint in the future.

79 ASTRONOMY AND ASTROPHYSICS↗

The Performance of the Gamma-Ray Energy Tracking In-Beam Nuclear Array GRETINA

The Gamma-Ray Energy Tracking In-beam Nuclear Array (GRETINA) is a new generation high-resolution -ray spectrometer consisting of electrically segmented high-purity germanium crystals. GRETINA is capable of reconstructing the energy and position of each -ray interaction point inside the crystal with high resolution. This enables -ray energy tracking which in turn provides an array with large photopeak efficiency, high resolution and good peak-to-total ratio. GRETINA is used for nuclear structure studies with demanding -ray detection requirements and it is suitable for experiments with radioactive-ion beams with high recoil velocities. The GRETINA array has a 1 solid angle coverage and constitutes the first stage towards the full 4 array GRETA. We present in this paper the main parts and the performance of the GRETINA system.

Paschalis, S.↗

Automated identification of elemental ions in macromolecular crystal structures

The solvent-picking procedure in phenix.refine has been extended and combined with Phaser anomalous substructure completion and analysis of coordination geometry to identify and place elemental ions. Many macromolecular model-building and refinement programs can automatically place solvent atoms in electron density at moderate-to-high resolution. This process frequently builds water molecules in place of elemental ions, the identification of which must be performed manually. The solvent-picking algorithms in phenix.refine have been extended to build common ions based on an analysis of the chemical environment as well as physical properties such as occupancy, B factor and anomalous scattering. The method is most effective for heavier elements such as calcium and zinc, for which a majority of sites can be placed with few false positives in a diverse test set of structures. At atomic resolution, it is observed that it can also be possible to identify tightly bound sodium and magnesium ions. A number of challenges that contribute to the difficulty of completely automating the process of structure completion are discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

In situ positioning of a few hundred micrometer-sized cleaved surfaces for soft-x-ray angle-resolved photoemission spectroscopy by use of an optical microscope

A method to position samples with small cleaved regions has been developed to be applied to the angle-resolved photoemission spectroscopy (ARPES) which uses soft-x-ray synchrotron radiation focused down to 160x180 {mu}m{sup 2}. A long-working-distance optical microscope is used for the sample observation. A selected region on a sample can be optimally set at the position of measurements, which is realized by the spatial resolution of the photoelectron analyzer. Using this method, electronic band dispersions of bulk silicon have been measured by ARPES for a partially cleaved region with a size of {approx}200x500 {mu}m{sup 2}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CHANDRA AND SWIFT FOLLOW-UP OBSERVATIONS OF THE INTERMEDIATE-MASS BLACK HOLE IN ESO 243-49

The brightest ultra-luminous X-ray source HLX-1 in the galaxy ESO 243-49 provides strong evidence for the existence of intermediate-mass black holes (IMBHs). As the luminosity and thus the mass estimate depend on the association of HLX-1 with ESO 243-49, it is essential to confirm its affiliation. This requires follow-up investigations at wavelengths other than X-rays, which in turn needs an improved source position. To further reinforce the IMBH identification, it is necessary to determine HLX-1's environment to establish whether it could potentially form and nourish a black hole at the observed luminosities. Using the High Resolution Camera on board Chandra, we determine a source position of R.A. = 01{sup h}10{sup m}28.{sup s}3 and decl. = -46{sup 0}04'22.''3. A conservative 95% error of 0.''3 was found following a boresight correction by cross-matching the positions of three X-ray sources in the field with the Two Micron All Sky Survey catalog. Combining all Swift UV/Optical Telescope uvw2 images, we failed to detect a UV source at the Chandra position down to a 3{sigma} limiting magnitude of 20.25 mag. However, there is evidence that the UV emission is elongated in the direction of HLX-1. This is supported by archival data from GALEX and suggests that the far-UV emission is stronger than the near-UV. This could imply that HLX-1 may be situated near the edge of a star-forming region. Using the latest X-ray observations, we deduce the mass accretion rate of a 500 M {sub sun} black hole with the observed luminosity and show that this is compatible with such an environment.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-F-I-54: Spatial Resolution Studies in Proton CT Using a Phase-II Prototype Head Scanner

Purpose: To characterize the modulation transfer function (MTF) of the pre-clinical (phase II) head scanner developed for proton computed tomography (pCT) by the pCT collaboration. To evaluate the spatial resolution achievable by this system. Methods: Our phase II proton CT scanner prototype consists of two silicon telescopes that track individual protons upstream and downstream from a phantom, and a 5-stage scintillation detector that measures a combination of the residual energy and range of the proton. Residual energy is converted to water equivalent path length (WEPL) of the protons in the scanned object. The set of WEPL values and associated paths of protons passing through the object over a 360° angular scan is processed by an iterative parallelizable reconstruction algorithm that runs on GP-GPU hardware. A custom edge phantom composed of water-equivalent polymer and tissue-equivalent material inserts was constructed. The phantom was first simulated in Geant4 and then built to perform experimental beam tests with 200 MeV protons at the Northwestern Medicine Chicago Proton Center. The oversampling method was used to construct radial and azimuthal edge spread functions and modulation transfer functions. The spatial resolution was defined by the 10% point of the modulation transfer function in units of lp/cm. Results: The spatial resolution of the image was found to be strongly correlated with the radial position of the insert but independent of the relative stopping power of the insert. The spatial resolution varies between roughly 4 and 6 lp/cm in both the the radial and azimuthal directions depending on the radial displacement of the edge. Conclusion: The amount of image degradation due to our detector system is small compared with the effects of multiple Coulomb scattering, pixelation of the image and the reconstruction algorithm. Improvements in reconstruction will be made in order to achieve the theoretical limits of spatial resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The CN–CH Positive Correlation in the Globular Cluster NGC 5286

We performed low-resolution spectroscopy of the red giant stars in the Galactic globular cluster (GC) NGC 5286, which is known to show intrinsic heavy element abundance variations. We found that the observed stars in this GC are clearly divided into three subpopulations by CN index (CN-weak, CN-intermediate, and CN-strong). The CN-strong stars are also enhanced in the calcium HK′ (7.4 σ ) and CH (5.1 σ ) indices, while the CN-intermediate stars show no significant difference in the strength of the HK′ index from the CN-weak stars. From the comparison with high-resolution spectroscopic data, we found that the CN- and HK′-strong stars are also enhanced in the abundances of Fe and s -process elements. It appears, therefore, that these stars are later-generation stars affected by some supernova enrichment in addition to the asymptotic giant branch ejecta. In addition, unlike normal GCs, sample stars in NGC 5286 show the CN–CH positive correlation, strengthening our previous suggestion that this positive correlation is only discovered in GCs with heavy element abundance variations, such as M22 and NGC 6273.

79 ASTRONOMY AND ASTROPHYSICS↗

Increasing the electron-transfer ability of Cyanidioschyzon merolae ferredoxin by a one-point mutation – A high resolution and Fe-SAD phasing crystal structure analysis of the Asp58Asn mutant

Highlights: •A single amino acid change on the ferredoxin surface affects electron transfer. •Precise positions of amide atoms were located utilizing no prior structural data. •Ultra high resolution and SAD phasing may be used for bias-free model building. -- Abstract: Cyanidioschyzon merolae (Cm) is a single cell red algae that grows in rather thermophilic (40–50 °C) and acidic (pH 1–3) conditions. Ferredoxin (Fd) was purified from this algae and characterized as a plant-type [2Fe–2S] Fd by physicochemical techniques. A high resolution (0.97 Å) three-dimensional structure of the CmFd D58N mutant molecule has been determined using the Fe-SAD phasing method to clarify the precise position of the Asn58 amide, as this substitution increases the electron-transfer ability relative to wild-type CmFd by a factor of 1.5. The crystal structure reveals an electro-positive surface surrounding Asn58 that may interact with ferredoxin NADP{sup +} reductase or cytochrome c.

60 APPLIED LIFE SCIENCES↗

Towards high-resolution ptychographic x-ray diffraction microscopy

Ptychographic x-ray diffraction microscopy is a lensless imaging technique with a large field of view and high spatial resolution, which is also useful for characterizing the wavefront of an x-ray probe. The performance of this technique is degraded by positioning errors due to the drift between the sample and illumination optics. We propose an experimental approach for correcting the positioning errors and demonstrate success by two-dimensionally reconstructing both the wavefront of the focused x-ray beam and the complex transmissivity of the weakly scattering objects at the pixel resolution of better than 10 nm in the field of view larger than 5 {mu}m. This method is applicable to not only the observation of organelles inside cells or nano-mesoscale structures buried within bulk materials but also the characterization of probe for single-shot imaging with x-ray free electron lasers.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

On the use of a single-fiber multipoint plastic scintillation detector for {sup 192}Ir high-dose-rate brachytherapy

Purpose: The goal of this study was to prove the feasibility of using a single-fiber multipoint plastic scintillation detector (mPSD) as an in vivo verification tool during {sup 192}Ir high-dose-rate brachytherapy treatments.Methods: A three-point detector was built and inserted inside a catheter-positioning template placed in a water phantom. A hyperspectral approach was implemented to discriminate the different optical signals composing the light output at the exit of the single collection optical fiber. The mPSD was tested with different source-to-detector positions, ranging from 1 to 5 cm radially and over 10.5 cm along the longitudinal axis of the detector, and with various integration times. Several strategies for improving the accuracy of the detector were investigated. The device's accuracy in detecting source position was also tested.Results: Good agreement with the expected doses was obtained for all of the scintillating elements, with average relative differences from the expected values of 3.4 {+-} 2.1%, 3.0 {+-} 0.7%, and 4.5 {+-} 1.0% for scintillating elements from the distal to the proximal. A dose threshold of 3 cGy improved the general accuracy of the detector. An integration time of 3 s offered a good trade-off between precision and temporal resolution. Finally, the mPSD measured the radioactive source positioning uncertainty to be no more than 0.32 {+-} 0.06 mm. The accuracy and precision of the detector were improved by a dose-weighted function combining the three measurement points and known details about the geometry of the detector construction.Conclusions: The use of a mPSD for high-dose-rate brachytherapy dosimetry is feasible. This detector shows great promise for development of in vivo applications for real-time verification of treatment delivery.

61 RADIATION PROTECTION AND DOSIMETRY↗

Vacuum compatible sample positioning device for matrix assisted laser desorption/ionization Fourier transform ion cyclotron resonance mass spectrometry imaging

The high mass accuracy and resolving power of Fourier transform ion cyclotron resonance mass spectrometers (FT-ICR MS) make them ideal mass detectors for mass spectrometry imaging (MSI), promising to provide unmatched molecular resolution capabilities. The intrinsic low tolerance of FT-ICR MS to RF interference, however, along with typically vertical positioning of the sample, and MSI acquisition speed requirements present numerous engineering challenges in creating robotics capable of achieving the spatial resolution to match. This work discusses a two-dimensional positioning stage designed to address these issues. The stage is capable of operating in {approx}1 x 10{sup -8} mbar vacuum. The range of motion is set to 100 mm x 100 mm to accommodate large samples, while the positioning accuracy is demonstrated to be less than 0.4 micron in both directions under vertical load over the entire range. This device was integrated into three different matrix assisted laser desorption/ionization (MALDI) FT-ICR instruments and showed no detectable RF noise. The ''oversampling'' MALDI-MSI experiments, under which the sample is completely ablated at each position, followed by the target movement of the distance smaller than the laser beam, conducted on the custom-built 7T FT-ICR MS demonstrate the stability and positional accuracy of the stage robotics which delivers high spatial resolution mass spectral images at a fraction of the laser spot diameter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

{sup 3}He alternative technologies: 1. Application of neutron image plate detector for powder diffractometry

Neutron image plate was used for recording powder diffraction pattern from a polycrystalline Fe rod, mounted on the High Q Diffractometer at Dhruva reactor and using neutron beam of {lambda}= 0.783 A and {Phi}= 3 x 10{sup 5} n/cm{sup 2}/sec. The Bragg peaks were sharp and well resolved. The overall resolution ({Delta}2{theta}/2{theta}) value was found be {approx}0.025.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ACCURATE OH MASER POSITIONS FROM THE SPLASH PILOT REGION

We report on high spatial resolution observations, using the Australia Telescope Compact Array (ATCA), of ground-state OH masers. These observations were carried out toward 196 pointing centers previously identified in the Southern Parkes Large-Area Survey in Hydroxyl (SPLASH) pilot region, between Galactic longitudes of 334° and 344° and Galactic latitudes of −2° and +2°. Supplementing our data with data from the MAGMO (Mapping the Galactic Magnetic field through OH masers) survey, we find maser emission toward 175 of the 196 target fields. We conclude that about half of the 21 nondetections were due to intrinsic variability. Due to the superior sensitivity of the followup ATCA observations, and the ability to resolve nearby sources into separate sites, we have identified 215 OH maser sites toward the 175 fields with detections. Among these 215 OH maser sites, 111 are new detections. After comparing the positions of these 215 maser sites to the literature, we identify 122 (57%) sites associated with evolved stars (one of which is a planetary nebula), 64 (30%) with star formation, two sites with supernova remnants, and 27 (13%) of unknown origin. The infrared colors of evolved star sites with symmetric maser profiles tend to be redder than those of evolved star sites with asymmetric maser profiles, which may indicate that symmetric sources are generally at an earlier evolutionary stage.

79 ASTRONOMY AND ASTROPHYSICS↗