Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Life Qualification of Hall Thrusters By Analysis and Test

High power Hall thrusters under development for deep space robotic and human exploration missions have demanding lifetime and operational requirements that make thruster life qualification challenging. The required burn times make it infeasible to conduct multiple tests with durations exceeding the life requirement, and complex wearout phenomena and the need for power throttling during missions complicate analyses and testing. The traditional qualification approach, a single life test that typically demonstrates 50 to 100% margin on the required lifetime, does not provide enough information to demonstrate low failure risk. It is a weak source of statistical information about the location of the peak in the failure probability distribution and provides no information on the width of the distribution. Testing does provide information that can be used to validate physics-based models of failure processes, however, and the combination can be used to assess mission risk. Validated, conservative, deterministic analysis can be used to demonstrate that most failure processes have such large margins that more detailed analysis is unnecessary. For a subset of the failure modes a more detailed probabilistic analysis is required. Pole erosion in a 12.5 kW Hall thruster is used as a detailed example of this qualification process.

Brophy, John R.↗

Utility-Scale Power Tower Solar Systems: Performance Acceptance Test Guidelines

The purpose of these Guidelines is to provide direction for conducting performance acceptance testing for large power tower solar systems that can yield results of a high level of accuracy consistent with good engineering knowledge and practice. The recommendations have been developed under a National Renewable Energy Laboratory (NREL) subcontract and reviewed by stakeholders representing concerned organizations and interests throughout the concentrating solar power (CSP) community. An earlier NREL report provided similar guidelines for parabolic trough systems. These Guidelines recommend certain methods, instrumentation, equipment operating requirements, and calculation methods. When tests are run in accordance with these Guidelines, we expect that the test results will yield a valid indication of the actual performance of the tested equipment. But these are only recommendations--to be carefully considered by the contractual parties involved in the Acceptance Tests--and we expect that modifications may be required to fit the particular characteristics of a specific project.

14 SOLAR ENERGY↗

Equivalent Test Bed in PSCAD and PSLF for Studying Advanced Power Systems Controller Performance

With increasing popularity of sustainable energy resources, research on power electronic-based renewable generation modeling is gaining impetus to enhance reliability of electric grids with high penetrations of renewable energy. A set of generic and public models for renewable energy are available in commercial positive sequence power system simulation software. However, advanced controller models applicable for renewable resources are typically not included in these tools. To ensure the integrity of the newly developed controller models for renewables in positive sequence simulators for large power systems, it is necessary to validate the dynamic performance of the proposed model with detailed electromagnetic models. This paper creates an equivalent test bed in PSCAD and PSLF for validating the performance of advanced controllers associated with renewable energy sources. To demonstrate the usefulness of the test-bed, a user-defined synthetic inertia (SI) controller model was developed in PSLF and validated through the proposed test bed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Lift Fan Nozzle for Joint Strike Fighter Tested in NASA Lewis' Powered Lift Rig

Under a nonreimbursable space act agreement between the NASA Lewis Research Center and the Allison Advanced Development Company, Allison tested a lift fan nozzle in Lewis' Powered Lift Rig. This test was in support of the Joint Strike Fighter program (formerly the Joint Advanced Strike Technology) sponsored by the Department of Defense, which will develop and field an affordable, multirole, next-generation, strike fighter aircraft for the Navy, Air Force, Marine Corps, and foreign allies. Allison, along with Pratt & Whitney Company, is part of the Lockheed Martin Corporation team that is scheduled to build a concept demonstrator aircraft by fiscal year 2001. The test was initiated in April and successfully completed in mid-July of 1997. Allison supplied a one-third-scale model of the lift fan nozzle, and Lewis provided the facility and the necessary support team. Various configurations, including pitching vectored angles ranging from 15deg forward to 60deg backward, were tested over a range of nozzle pressure ratios. Nozzle flow rates, thrust, and static pressures were measured for each of the configurations. Results from the test met the design requirements for the Joint Strike Fighter program and were in agreement with Allison's internal computational fluid dynamics (CFD) analyses. Data obtained from this test will also be used in the full-scale design of the lift fan system.

Lam, David W.↗

Static tests of the J97 powered, external augmenter V/STOL wind tunnel model

Results of the static testing (zero forward speed) of the J97-powered, external augmentor, large scale, V/STOL model are discussed. With a ground clearance of 7.5 feet, believed to have put the model essentially out of ground effect, a gross thrust augmentation ratio of 1.60 at nozzle pressure ratio (NPR) = 3.0 was measured for the fuselage augmentor. A similar figure was apparent for the wing augmentor. An overall ratio of model thrust to bare engine thrust of 1.52 was determined at NPR = 3.0. The structural integrity of the model was well demonstrated and duct pressure losses were small.

Garland, D. B.↗

Qualification testing and electrical measurement experience: A manufacturer's view

ARCO Solar's experiences as a participant in an industry-utility-government environmental qualification team examining photovoltaic devices are discussed. Included is an assessment of the applicability, completeness and appropriateness of the testing procedures and of the acceptance criteria for megawatt-sized procurements for utilities. Like the stand-alone users, the utility industry is interested in obtaining low costs, but additional concerns exist related to reliability and durability, safety, grounding and overall system criteria including performance prediction (related to output power acceptance testing), power quality and dispatchability. For purposes of this first major purchase of photovoltaic modules and panels by the utility industry, there was a carry-over of the JPL specifications. The need exists for futher development, assessement, and selection of qualification and testing standards and evaluation criteria specifically addressing these additional concerns for utility-connected PV power-plant applications.

Arnett, J. C.↗

Tank Test of an Active Power Rectification in Wave-to-Wire Energy Conversion

Maximum power control algorithms in wave energy converter (WEC) are mainly based on the fluid-structure dynamics with impedance matching from power take-off (PTO) damping or model predictive control through the buoy dynamics. However, the conventional buoy characteristics study cannot satisfy estimation of maximum output power in a practical wave-to-wire (W2W) system due to significant losses on mechanical and electrical components from PTO to power converter in comparison with the losses on the buoy. To analysis the non-ideal effects from mechanical transmission and energy conversion characteristics of WEC with a power converter output, a W2W simulation and tank testing is performed. The 1:20 scale WEC system with 1.17m buoy diameter includes a single body heaving buoy, mechanical-motion-rectifier based power-take-off, and power converter that store its output energy to a battery load. From the tank testing results, a circuit model is built and is used to estimate the system performance. The non-ideal effects such as viscous damping between buoy and power take-off, gearbox loss, generator loss, and power converter loss in the system are included in the circuit model with efficiencies from 60 - 80%. The maximum extracted power results under various wave conditions are dominated by these non-ideal effect.

16 TIDAL AND WAVE POWER↗

Flow tests of a single fuel element coolant channel for a compact fast reactor for space power

Water flow tests were conducted on a single-fuel-element cooling channel for a nuclear concept to be used for space power. The tests established a method for measuring coolant flow rate which is applicable to water flow testing of a complete mockup of the reference reactor. The inlet plenum-to-outlet plenum pressure drop, which approximates the overall core pressure drop, was measured and correlated with flow rate. This information can be used for reactor coolant flow and heat transfer calculations. An analytical study of the flow characteristics was also conducted.

Springborn, R. H.↗

High-Power Amplifier Considerations for testing the LAMP RFQ and first DTL Cavity

As part of the LANSCE Accelerator Modernization Pro ject (LAMP), critical portions of the proposed accelerator will be tested as proof of concept and aid in planning the installation of LAMP at Los Alamos Neutron Science Cen ter. As part of this demonstration, the radio frequency quadrupole (RFQ) and the first drift-tube linac (DTL) cav ity will be tested with beam. For this purpose, high-power RF amplifiers are being designed to meet the testing de mands. This is a description of the requirements of these amplifiers and how the design is intended to meet them.

42 ENGINEERING↗

3.9 GHz Power Coupler Design and Tests for LCLS-II Project

LCLS-II linac requires two 3.9 GHz cryomodules (eight cavities per CM), operating up to 16MV/m in cw regime. Fermilab has designed and built few prototypes of the cavity and auxiliaries and tested them at the vertical and horizontal cryostats. Fundamental power coupler, based on existing design (FLASH, XFEL) was redesign for 2kW average power. We built three prototypes and tested them at room temperature test stand. One coupler was assembled on the cavity and tested at horizontal cryostat as part of design verification program. Test results and comparison with simulations are discussed in this paper.

43 PARTICLE ACCELERATORS↗

OSU High Temperature Test Facility Test Acceptance Report, PG-30 Low Power (<350kW) Lower Plenum Mixing, Constant Temperature Test

Test Acceptance Report for Test PG-30 at the Oregon State University High Temperature Test Facility. The purpose of this test is to investigate the impact on Lower Plenum thermal profiles and mixing due to changes in the system mass flow rate in an integral test facility scaled to General Atomics’ Modular High Temperature Gas Reactor (MHTGR) design.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of Ada language control software for the NASA power management and distribution test bed

The Ada language software developed to control the NASA Lewis Research Center's Power Management and Distribution testbed is described. The testbed is a reduced-scale prototype of the electric power system to be used on space station Freedom. It is designed to develop and test hardware and software for a 20-kHz power distribution system. The distributed, multiprocessor, testbed control system has an easy-to-use operator interface with an understandable English-text format. A simple interface for algorithm writers that uses the same commands as the operator interface is provided, encouraging interactive exploration of the system.

Wright, Ted↗

Testing of Two Mars Powered Descent Vehicle Concepts in the Langley Unitary Plan Wind Tunnel

Testing was conducted in the NASA Langley Unitary Plan Wind Tunnel in order to investigate the aerodynamic interference of sub-scale versions of two Mars powered descent vehicle concepts at supersonic Mach numbers (2.4 and 3.5): a model based on a blunt hypersonic inflatable aerodynamic decelerator (HIAD) and the second representing a more slender rigid vehicle with body flaps (CobraMRV). Each model was designed to accommodate up to eight nozzles, with the HIAD model having five different nozzle configurations to investigate the effects of nozzle location, cant angle, and area ratio. The models were tested with high pressure air as the nozzle plume gas, and included the following instrumentation: high-speed video, discrete steady state and high-frequency pressure, pressure sensitive paint, and a new flow-through force and moment balance for the HIAD model. The high-speed imagery showed the overall expected growth of the shock layer to increasing thrust levels. The discrete stagnation pressure data on the HIAD model with four and eight blowing nozzles was sensitive to thrust coefficient with the nozzles canted at 0 degrees, whereas having nozzles canted outward 20 degrees and/or being located closer to the heatshield shoulder largely removed that sensitivity. The CobraMRV model stagnation pressure was more sensitive to tunnel Mach number and sideslip angle, due to the nozzle arrangement and plume interference. Pressure sensitive paint data quality was compromised by paint damage from frequent model changes, especially for the HIAD model. However, pressure coefficient data on the CobraMRV model showed the same trends as the discrete pressure measurements, as well as a sensitivity to non-zero sideslip angles. The aerodynamic force coefficients were derived from the pressure sensitive paint data. On the HIAD models, the primary force coefficient decreased with increasing thrust due to the nozzle plumes blocking flow to the heatshield area surrounding the nozzle exist. On the CobraMRV model, the force coefficient was relatively insensitive to thrust coefficient at the lower Mach number when sideslip angle was 0 degrees The force coefficient decreases with increasing thrust coefficient when the sideslip angle is 10 degrees. Balance data quality was negatively impacted by thermal drift issues that were not apparent in pre-test calibration measurements, thus preventing usable test data. Results and lessons learned will be used to take further technology development steps, including more advanced ground test techniques and flight testing.

Karl T Edquist↗

Testing of Two Mars Powered Descent Vehicle Concepts in the Langley Unitary Plan Wind Tunnel

Testing was conducted in the NASA Langley Unitary Plan Wind Tunnel in order to investigate the aerodynamic interference of sub-scale versions of two Mars powered descent vehicle concepts at supersonic Mach numbers (2.4 and 3.5): a model based on a blunt hypersonic inflatable aerodynamic decelerator (HIAD) and the second representing a more slender rigid vehicle with body flaps (CobraMRV). Each model was designed to accommodate up to eight nozzles, with the HIAD model having five different nozzle configurations to investigate the effects of nozzle location, cant angle, and area ratio. The models were tested with high pressure air as the nozzle plume gas, and included the following instrumentation: high-speed video, discrete steady state and high-frequency pressure, pressure sensitive paint, and a new flow-through force and moment balance for the HIAD model. The high-speed imagery showed the overall expected growth of the shock layer to increasing thrust levels. The discrete stagnation pressure data on the HIAD model with four and eight blowing nozzles was sensitive to thrust coefficient with the nozzles canted at 0 degrees, whereas having nozzles canted outward 20 degrees and/or being located closer to the heatshield shoulder largely removed that sensitivity. The CobraMRV model stagnation pressure was more sensitive to tunnel Mach number and sideslip angle, due to the nozzle arrangement and plume interference. Pressure sensitive paint data quality was compromised by paint damage from frequent model changes, especially for the HIAD model. However, pressure coefficient data on the CobraMRV model showed the same trends as the discrete pressure measurements, as well as a sensitivity to non-zero sideslip angles. The aerodynamic force coefficients were derived from the pressure sensitive paint data. On the HIAD models, the primary force coefficient decreased with increasing thrust due to the nozzle plumes blocking flow to the heatshield area surrounding the nozzle exist. On the CobraMRV model, the force coefficient was relatively insensitive to thrust coefficient at the lower Mach number when sideslip angle was 0 degrees The force coefficient decreases with increasing thrust coefficient when the sideslip angle is 10 degrees. Balance data quality was negatively impacted by thermal drift issues that were not apparent in pre-test calibration measurements, thus preventing usable test data. Results and lessons learned will be used to take further technology development steps, including more advanced ground test techniques and flight testing.

Supersonic Retropropulsion↗

Thermomechanical Characterization and Analysis of Insulation Materials for Nuclear-Based Space Power Systems

Testing was carried out to characterize and predict the long-term thermomechanical properties of various thermal insulation materials for use in nuclear-based space power systems. In particular, the high temperature compressive strength and stress relaxation behavior of these materials under vacuum or an inert atmosphere and up to 950 C were evaluated under either isothermal conditions or under various thermal gradients for test times of over two years. Several tests subjected to thermal gradient conditions were also evaluated for changes in strain due to cooling or heating events. Other testing of these materials included evaluation of their response to lateral (as opposed to axial) loads, their response to triaxial loading conditions, thermal shock behavior of these materials, and shrinkage effects in these materials due to elevated temperature exposure. Additionally, finite element and mathematical models were formulated to predict the mechanical behavior exhibited by these materials out to 35,000 hours (4 years) based on this testing. This paper will summarize the design and construction of unique test equipment to carry out this testing, along with the results of the testing and the subsequent modeling.

NESDPS Office of Nuclear Energy Space and Defense ↗

Photovoltaic-Powered Vaccine Refrigerator: Freezer Systems Field Test Results

A project to develop and field test photovoltaic-powered refrigerator/freezers suitable for vaccine storage was undertaken. Three refrigerator/freezers were qualified; one by Solar Power Corp. and two by Solvolt. Follow-on contracts were awarded for 19 field test systems and for 10 field test systems. A total of 29 systems were installed in 24 countries between October 1981 and October 1984. The project, systems descriptions, installation experiences, performance data for the 22 systems for which field test data was reported, an operational reliability summary, and recommendations relative to system designs and future use of such systems are explained. Performance data indicate that the systems are highly reliable and are capable of maintaining proper vaccine storage temperatures in a wide range of climatological and user environments.

Ratajczak, A. F.↗

Use of Internal Coolant as a Means of Permitting Increase in Engine Take-Off Power

Engine tests, together with estimates made at Langley Memorial Aeronautical Laboratory, indicate that a 25-percent increase in take-off power can be obtained with present-day aircraft engines without increasing either the knock limit of the fuel or the external cooling requirements of the engine. This increase in power with present fuels and present external cooling is made possible through the use of an internal coolant inducted through the inlet manifold. Estimates on aircraft indicate that this 25-percent increase in power will permit an approximate usable increase of 8.5 percent in the take-off load of existing military airplanes. This increase in load is equivalent to an increase in the weight of gasoline normally carried of between 30 and 65 percent.

FUELS, ANTIKNOCK↗