Search NASA⌕ Search

SEARCH · Search NASA

Results for “Pressure Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Pressure Distributions from Subsonic Tests of a NACA 0012 Semispan Wing Model

An unswept, semispan wing model incorporating a NACA 0012 airfoil section was tested in the Langley 14- by 22-Foot Subsonic Tunnel. This report contains pressure data which document effects of wing configuration and free-stream conditions on wing pressure distributions. The untwisted wing incorporated a full-span, leading-edge Krueger flap and a full-span, single-slotted trailing-edge flap. The trailing-edge flap was tested at a deflection angle of 40 degrees and the Krueger flap at a deflection of 55 degrees. Three wing configurations were tested: cruise, trailing-edge flap only, and Knueger flap and trailing-edge flap deployed. Tests were conducted at free-stream dynamic pressures of 15, 30 and 60 psf, with corresponding chord Reynolds numbers of 1.22 to 2.11 million and Mach numbers of 0.12 to 0.20. Angles of attack presented range from 0 to 20 degrees, depending on wing configuration. The data are presented without analysis.

Applin, Zachary T.↗

Acoustic testing of a 1.5 pressure ratio low tip speed fan with casing tip bleed (QEP Fan B scale model)

A scale model of the bypass flow region of a 1.5 pressure ratio, single stage, low tip speed fan was tested with a rotor tip casing bleed slot to determine its effects on noise generation. The bleed slot was located 1/2 inch (1.3 cm) upstream of the rotor leading edge and was configured to be a continuous opening around the circumference. The bleed manifold system was operated over a range of bleed rates corresponding to as much as 6% of the fan flow at approach thrust and 4.25% of the fan flow at takeoff thrust. Acoustic results indicate that a bleed rate of 4% of the fan flow reduces the fan maximum approach 200 foot (61.0 m) sideline PNL 0.5 PNdB and the corresponding takeoff thrust noise 1.1 PNdB below the level with zero bleed. However, comparison of the standard casing (no bleed slot) and the slotted bleed casing with zero bleed shows that the bleed slot itself caused a noise increase.

Kazin, S. B.↗

Acoustic testing of a 1.5 pressure ratio low tip speed fan with a serrated rotor (QEP fan B scale model)

A scale model of the bypass flow region of a 1.5 pressure ratio, single stage, low tip speed fan was tested with a serrated rotor leading edge to determine its effects on noise generation. The serrated rotor was produced by cutting teeth into the leading edge of the nominal rotor blades. The effects of speed and exhaust nozzle area on the scale models noise characteristics were investigated with both the nominal rotor and serrated rotor. Acoustic results indicate the serrations reduced front quadrant PNL's at takeoff power. In particular, the 200 foot (61.0 m) sideline noise was reduced from 3 to 4 PNdb at 40 deg for nominal and large nozzle operation. However, the rear quadrant maximum sideline PNL's were increased 1.5 to 3 PNdb at approach thust and up to 2 PNdb at takeoff thust with these serrated rotor blades. The configuration with the serrated rotor produced the lowest maximum 200 foot (61.0 m) sideline PNL for any given thust when the large nozzle (116% of design area) was employed.

Kazin, S. B.↗

Short Exploration Extravehicular Mobility Unit Testing Setup: Evaluation Under Realistic Pressure and Thermal Conditions

The purpose of Short Exploration Extravehicular Mobility Unit (SxEMU) thermal vacuum testing was to verify the functionality of the Design Verification Testing (DVT) prototype xEMU (SxEMU for this test) at vacuum pressures and extreme space and lunar surface temperature conditions. The SxEMU Thermal Vacuum Test was the culmination of the DVT xEMU project. This paper’s focus is on the pre-Extravehicular Activity (EVA) test setup, and general performance of the SxEMU Portable Life Support Subsystem (xPLSS), with focus on the performance of the Primary Oxygen Assembly (POA) and Secondary Oxygen Assembly (SOA), including Secondary Oxygen Regulator (SOR) takeover and the POA and SOA low-setpoint change inhibit. The initial pre-EVA test preparation included recharging the batteries and replenishing consumables, including test-system water, oxygen assemblies (with gaseous nitrogen), and the integrated thermal loops, including the Feedwater Supply Assemblies. xPLSS functionality testing included carbon dioxide (CO2) removal via the Rapid Cycle Amine swingbed system, thermal loop temperature control, and monitoring of suit ventilation loop pressure, temperature, and CO2 percentages. Testing evaluated automatic takeover of suit pressure control by the SOR after the primary oxygen supply is depleted. The Primary Oxygen Regulator and SOR low-setpoint change inhibit function prevents the crewmember from inadvertently setting the primary regulator to a low pressure setpoint during an EVA.

xPLSS↗

Cyclic Crack Growth Testing of an A.O. Smith Multilayer Pressure Vessel with Modal Acoustic Emission Monitoring and Data Assessment

Digital Wave Corp. (DWC) was retained by Jacobs ATOM at NASA Ames Research Center to perform cyclic pressure crack growth sensitivity testing on a multilayer pressure vessel instrumented with DWC's Modal Acoustic Emission (MAE) system, with captured wave analysis to be performed using DWCs WaveExplorerTM software, which has been used at Ames since 2001. The objectives were to document the ability to detect and characterize a known growing crack in such a vessel using only MAE, to establish the sensitivity of the equipment vs. crack size and / or relevance in a realistic field environment, and to obtain fracture toughness materials properties in follow up testing to enable accurate crack growth analysis. This report contains the results of the testing.

Ziola, Steven M.↗

Exploration Extravehicular Mobility Unit (xEMU) Chamber B Thermal Vacuum “Suit 2” Pressure Garment System Hardware and Test Design

NASA’s Exploration Extravehicular Mobility Unit (xEMU) is the government reference next-generation space suit design and is engineered to protect astronauts from extreme lunar environmental temperatures. To evaluate the xEMU hardware thermal requirements, the xEMU Testing Team invented, designed, and executed a dual-suit, uncrewed thermal vacuum (TVAC) test at Johnson Space Center’s (JSC) Chamber B. This paper details the test hardware design and test methodology for the “Suit 2” Pressure Garment System (PGS) test article. The uncrewed “Suit 2” PGS test article consisted of a full PGS assembly with simulated Portable Life Support System (PLSS) functionality provided by test equipment, including a ventilation loop and two distinct thermal control loops. This paper will discuss in depth the test hardware design, including internal suit thermal boundary simulation, sensor quantity and placement, test support equipment rigs for gas flow, water flow, and power. Custom hardware designed to add additional penetrations to the suit or provide additional interfaces for sensors will also be discussed. This paper will also address the assembly and integration sequence for the test article. In addition to test hardware design, this paper will provide insights into the test methodology for this test article, including a discussion of thermal steady-state testing, simultaneous dual suit thermal vacuum testing, and hazard mitigation and controls.

xEMU↗

Viability of Small Dimension Crew Quarters for Surface Habitation

During early planning for the Artemis program’s sustained phase of lunar activity, NASA planners have been held to work towards a NASA reference lunar lander concept. With this activity taking place prior to the awarding of a lander contract, NASA planners cannot assume which of several potential landers will be available. This has limited habitation team engineers to a 12-metric ton mass limit for the reference concept of the lunar Surface Habitat. Consequently, minimal approaches have been applied to many habitat systems and it is important to determine acceptable volume for crew quarters. A number of both NASA and non-NASA surface habitat concepts have proposed relatively small crew quarters due to this constraint. Consequently, there is a need to collect objective test data to confirm or refute the validity of small crew quarters. NASA-STD-3001 is looked to for guidance in its many standards but offers little to no help. While prior versions called for private habitation, the current version – Revision B – calls for “individual privacy” to “accommodate social retreat.” Proposed Revision C modifications change the language slightly to “accommodate sleep and social retreat.” This is not enough guidance to determine the size of a crew quarters or even its capabilities. Unfortunately, only a small number of US spacecraft have included crew quarters, primarily the International Space Station and the Skylab Space Station. The space shuttle orbiter sometimes flew a set of private bunks that some might consider a crew quarters. All of these are dramatically smaller than US standards for minimum jail cells. The first opportunity for NASA to test a small crew quarters in a surface habitat application has been created through the Exploration Atmospheres test series, which is evaluating human performance under reduced cabin pressures. The test is converting the 20-Foot Vacuum Chamber at Johnson Space Center into a habitat, with the lower level outfitted as an EVA test area and the upper two levels for human habitation. The test will place eight people (six test subjects and two technicians) inside the chamber for eleven days. All eight will sleep in private quarters during the test. Volume limitations in the chamber forced extremely small crew quarters, measuring approximately 2 meters in length, 0.85 meters in height, and 0.9 meters in width. The test cabin pressure of 8.2 psi and elevated oxygen also introduces significant material limitations, limiting outfitting options. Nonetheless, the crew quarters design requirements were to accommodate visual separation, auditory separation, olfactory separation, tactile separation, air flow control, lighting control, single person personal computing, physical work surface access, sleep accommodations, non-sleep rest/relaxation, meditation, stretching, two-person meetings, snacking, changing clothes, viewing appearance, video communication, and audio communication. This paper will detail the acceptability of the crew quarters as measured in the October 2021 Exploration Atmosphere test. Based on this data, the viability of the type of crew quarters used in the 20 Foot Chamber will be assessed. Design recommendations for a 30-60-day Surface Habitat crew quarters will be provided, along with recommendations for future testing.

Crew Quarters↗

Testing the Effects of Helium Pressurant on Thermodynamic Vent System Performance with Liquid Hydrogen

In support of the development of a zero gravity pressure control capability for liquid hydrogen, testing was conducted at the Marshall Space Flight Center using the Multipurpose Hydrogen Test Bed (MHTB) to evaluate the effects of helium pressurant on the performance of a spray bar thermodynamic vent system (TVS). Fourteen days of testing was performed in August - September 2005, with an ambient heat leak of about 70-80 watts and tank fill levels of 90%, 50%, and 25%. The TVS successfully controlled the tank pressure within a +/- 3.45 kPa (+/- 0.5 psi) band with various helium concentration levels in the ullage. Relative to pressure control with an "all hydrogen" ullage, the helium presence resulted in 10 to 30 per cent longer pressure reduction durations, depending on the fill level, during the mixing/venting phase of the control cycle. Additionally, the automated control cycle was based on mixing alone for pressure reduction until the pressure versus time slope became positive, at which time the Joule-Thomson vent was opened. Testing was also conducted to evaluate thermodynamic venting without the mixer operating, first with liquid then with vapor at the recirculation line inlet. Although ullage stratification was present, the ullage pressure was successfully controlled without the mixer operating. Thus, if vapor surrounded the pump inlet in a reduced gravity situation, the ullage pressure can still be controlled by venting through the TVS Joule Thomson valve and heat exchanger. It was evident that the spray bar configuration, which extends almost the entire length of the tank, enabled significant thermal energy removal from the ullage even without the mixer operating. Details regarding the test setup and procedures are presented in the paper. 1

Flachbart, R. H.↗

1- by 1-Foot Supersonic Wind Tunnel Sidewall Flowfield Compression Plate Study

A method for locally increasing the dynamic pressure in the test section of a supersonic wind tunnel is investigated from a theoretical, computational and experimental perspective, culminating in a reduced-scale, proof-of-concept test at Mach 3.44. Symmetric, variable-angle compression plates along the test section sidewalls generate oblique shockwaves to elevate the test section dynamic pressure (q). The experimental effort utilizes boundary-layer pitot rakes to sample the incoming flow near the floor, pitot and static rakes to measure the high-q core flow and numerous surface taps to map out the static pressure distribution along the floor, ceiling and sidewalls. A reliable and robust starting procedure is developed to establish supersonic flow in the test section and behind the compression plates. A characterization of the incoming floor boundary layer reveals previously documented features (such as a bulge toward the centerline) and an unexpected (and as-yet-unexplained) thickening of the boundary layer with increasing Reynolds number around total pressures of 40–60 psia. The high-q core flow is characterized for eight compression plate angles (4.0–8.0°), eight tunnel total pressures (20–139 psia) and three axial stations (24.95–27.35 inches). The peak dynamic pressure rise exceeds expectations. At conditions relevant to full-scale testing (6.0° and 139 psia), the dynamic pressure increases by a factor of 1.73, the Mach number becomes 2.85 and the total pressure drops imperceptibly. Basic distortion metrics show transverse non-uniformity of less than 5 %. Limited spatial resolution in the static rake measurements warrants additional, higher fidelity testing or computational analysis. Surface-mounted, fast-response instrumentation suggests minimal unsteadiness in the flow, less than a few percent of the mean (comparable to the sensor accuracy).

Wind tunnel testing, test techniques/methods, dyna↗

Pressure distributions from subsonic tests of an advanced laminar-flow-control wing with leading- and trailing-edge flaps

An unswept, semispan wing model equipped with full-span leading- and trailing-edge flaps was tested in the Langley 14- by 22-Foot Subsonic Tunnel to determine the effect of high-lift components on the aerodynamics of an advanced laminar-flow-control (LFC) airfoil section. Chordwise pressure distributions near the midsemispan were measured for four configurations: cruise, trailing-edge flap only, and trailing-edge flap with a leading-edge Krueger flap of either 0.10 or 0.12 chord. Part 1 of this report (under separate cover) presents a representative sample of the plotted pressure distribution data for each configuration tested. Part 2 presents the entire set of plotted and tabulated pressure distribution data. The data are presented without analysis.

Applin, Zachary T.↗

Novel Geochemistry Determined from High Pressure, High Temperature Simulation Experiments of Hydraulic Fracture Test Site 2

A standard method in unconventional oil and gas production is the process of hydraulic fracturing followed by a shut-in period, during which the fracture fluid remains pressurized in the reservoir for up to three weeks before production begins. Despite this widely used process, very little is known about what occurs in the reservoir during this shut-in process. In order to properly delineate potential reservoir reactions that may occur during shut-in that would lead to corrosion and scaling events, experiments were conducted in high pressure, high temperature reactors to simulate conditions of the Wolfcamp Formation in the Delaware Basin. Experimental design allowed the assessment of the effect of proppant, microbiology, and time on the mineralogy and fluid chemistry in the reservoir. Results suggest the biggest impact on fluid chemistry and shale mineralogy during shut-in is time. Analyses demonstrate dissolution of the shale material, with maximum dissolved ions occurring after 7 days of the shut-in period. After 21 days, results suggest precipitation occurs. The Delaware Basin is demonstrated to be high in sulfate content, which further increases in the fluid due to dissolution reactions during shut-in. The pressure vessel experiments suggest there was no significant contribution to reactions from microbiology during the shut-in period. Furthermore, early production samples demonstrate a significant selection of the microorganism Caminicella, a genus of which has previously been correlated to corrosion and sulfide production. Results suggest shut-in conditions may provide high sulfate concentrations that could later be utilized by a shifted microbial community to drive potential well infrastructure failure. This is the first study to incorporate microbiology, mineralogy, and fluid chemistry to investigate the fundamental geochemical reactions that occur during shut-in and early phase production of the Delaware Downloaded from http://onepetro.org/URTECONF/proceedings-pdf/21URTC/2-21URTC/D021S032R001/2477425/urtec-2021-5219-ms.pdf/1 by Carol Worster on 28 February 2022 Basin. Results from this study can complement observations from the Hydraulic Fracture Test Site 2 observations

58 GEOSCIENCES↗

Ares I Scale Model Acoustic Tests Instrumentation for Acoustic and Pressure Measurements

The Ares I Scale Model Acoustic Test (ASMAT) was a development test performed at the Marshall Space Flight Center (MSFC) East Test Area (ETA) Test Stand 116. The test article included a 5% scale Ares I vehicle model and tower mounted on the Mobile Launcher. Acoustic and pressure data were measured by approximately 200 instruments located throughout the test article. There were four primary ASMAT instrument suites: ignition overpressure (IOP), lift-off acoustics (LOA), ground acoustics (GA), and spatial correlation (SC). Each instrumentation suite incorporated different sensor models which were selected based upon measurement requirements. These requirements included the type of measurement, exposure to the environment, instrumentation check-outs and data acquisition. The sensors were attached to the test article using different mounts and brackets dependent upon the location of the sensor. This presentation addresses the observed effect of the sensors and mounts on the acoustic and pressure measurements.

Vargas, Magda B.↗

Centaur space vehicle pressurized propellant feed system tests

Engine firing tests, using a full-scale flight-weight vehicle, were performed to evaluate a pressurized propellant feed system for the Centaur. The pressurant gases used were helium and hydrogen. The system was designed to replace the boost pumps currently used on Centaur. Two liquid oxygen tank pressurization modes were studied: (1) directly into the ullage and (2) below the propellant surface. Test results showed the two Centaur RL10 engines could be started and run over the range of expected flight variables. No system instabilities were encountered. Measured pressurization gas quantities agreed well with analytically predicted values.

Source record↗

Engineering Area Investigation of Reliability Attributes and Accelerated Stress Factors on Terrestrial Solar Cells

Results obtained include the definition of a simplified stress test schedule for terrestrial solar cells based on the work performed during the first program year, and the design and fabrication of improved jigs and fixtures for electrical measurement and stress testing. Implementation of these advanced techniques for accelerated stress testing is underway on three solar cell types. In addition, review of the literature on second quadrant phenomena was begun and some preliminary second-quadrant electrical measurements were performed. Results obtained at the first down time for 75 C B-T testing and biased and unbiased T-H pressure cooker testing of type F cells showed little or no degradation in electrical parameters. Significant physical effects (large solder bubbles) were noted for type F cells subjected to the pressure cooker stress test.

Lathrop, J. W.↗

Wall pressure measurements for three-dimensional transonic tests

An experiment is described that provides input data for wind-tunnel wall interference assessment methods that are based on test-section wall pressure distributions. Wall pressures have been measured along orifice rows on the test-section walls during longitudinal force tests on two model sizes of the same configuration. These data were acquired at Mach numbers between 0.60 and 0.90 in a small, atmospheric transonic wind tunnel. A sample of the data and a discussion of results are presented.

Sewall, W. G.↗

Pressure distributions from subsonic tests of an advanced laminar-flow-control wing with leading- and trailing-edge flaps

An unswept, semispan wing model equipped with full-span leading- and trailing-edge flaps was tested in the Langley 14- by 22-Foot Subsonic Tunnel to determine the effect of high-lift components on the aerodynamics of an advanced laminar-flow-control (LFC) airfoil section. Chordwise pressure distributions near the midsemispan were measured for four configurations: cruise, trailing-edge flap only, and trailing-edge flap with a leading edge Kreuger flap of either 0.10 or 0.12 chord. Part 1 of this report presents a representative sample of the plotted pressure distribution data for each configuration tested. Part 2 (under separate cover) presents the entire set of plotted and tabulated pressure distribution data. The data are presented without analysis.

Applin, Zachary T.↗