Search NASA⌕ Search

SEARCH · Search NASA

Results for “Probe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Techniques for using emitting probes for potential measurement in RF plasmas

Investigations of the effects of RF on plasma potential measurements with electron emitting probes and methods for interpreting data are presented. Techniques correspond to the floating and inflection point methods of single-emitting and differential emitting probes, respectively. A simple method of measurement of plasma potential fluctuations is given which makes use of time-averaged emitting probe I-V characteristics.

Wang, E. Y.↗

Vortex Suppressors Reduce Probe Vibrations

Lightweight addition to probe reduces cyclical stress aerodynamically. Life expectancy of instrumentation probe for high-speed flow increased by addition of helical strakes to cylindrical shield surrounding probe. Strakes disrupt vortex shedding normally occuring in fast flows around cylindrical body.

Hill, Arthur J.↗

The calibration and operation of a constant-temperature crossed-wire probe in supersonic flow

The calibration and operation of a constant-temperature crossed-wire probe in supersonic flow is considered. Crossed-wire probes offer considerable advantages over single, inclined wires: the kinematic shear stress can be derived from a single point measurement; the rms quantities can be derived from the same measurement, and the instantaneous quantities can be obtained as a continuous function of time. However, using a crossed-wire probe in supersonic flow is subject to the following practical difficulties: the problem of flow interference, where the shock waves from one wire and its supports interfere with the flow over the other wire; the necessity for high frequency response to resolve the spectral content, and the sensitivity of the results to small changes in the calibration constants. In the present contribution, each of these problems is addressed. Practical solutions are suggested, and some encouraging results are presented.

Fernando, E. M.↗

Subminiature Hot-Wire Probes

Class of improved subminiature hot-wire flow-measuring probes developed. Smaller sizes yield improved resolution in measurements of practical aerodynamic flows. Probe made in one-wire, two-perpendicular-wire, and three-perpendicular-wire version for measurement of one, two, or all three components of flow. Oriented and positioned on micromanipulator stage and viewed under microscope during fabrication. Tested by taking measurements in constant-pressure turbulent boundary layer. New probes give improved measurements of turbulence quantities near surfaces and anisotropies of flows strongly influence relative errors caused by phenomena related to spatial resolution.

Westphal, R. V.↗

Theoretical derivation and calibration technique of a hemispherical-tipped, five-hole probe

A technique is presented for the calibration of a hemispherical tipped 0.125 inch diameter 5-hole probe. The derivation of equations from the potential flow over a sphere relating the flow angle and velocity to pressure differentials measured by the probe is presented. The technique for acquiring the calibration data and the technique used to calculate the calibration coefficients are presented. The accuracy of the probe in both the uniform calibration flow field and the nonuniform flow field over a 75 degree swept delta wing is discussed.

Kjelgaard, Scott O.↗

Project Longshot: An unmanned probe to Alpha Centauri

A preliminary design is presented for an unmanned probe to Alpha Centauri with a planned launch early in the 21st century. The probe would be assembled at the space station and take approx. 100 yrs to reach the nearest star. Several technologies must be developed in order for this mission to be possible. A pulsed fusion microexplosion drive with 1,000,000 secs of specific impulse is the primary enabling technology. A large, long life fission reactor with 300 kW power output is also required. Communications lasers would use a 0.532 micrometer wavelength since there is minimal power output by the stars in that frequency band. A laser with an input power of 250 kW would allow for a data rate of 1000 bits per second at maximum range. There are 3 types of information to be gathered by the probe: properties of the interstellar medium, characteristics of the three star Alpha Centauri system, and astrometry.

Beals, Keith A.↗

The use of dc-probe measurements in the middle atmosphere program

The middle atmosphere is weakly ionized, collision dominated plasma. Rocket-borne dc probes have proven effective in measuring conductivity and electron and ion concentrations in this plasma, and in some cases electron temperatures and ion composition were observed. During MAP, dc probes were also used successfully to study turbulence in the middle atmosphere, using the plasma as a passive tracer for the dynamical processes in the nonionized gas. Basic principles are reviewed of the dc-probe technique and examples are presented of results obtained during MAP.

Thrane, E. V.↗

Fabrication and testing of subminiature multi-sensor hot-wire probes

A method for the fabrication of hot-wire sensors measuring 0.6 micron in diameter and 200 microns in length is described. This method allows accurate control of sensing-element orientation, thus making it possible to produce multisensor probes. Test results obtained with a miniature sensor fabricated by this method, for the outer region of a turbulent boundary layer developing in a zero presure gradient were compared to measurements from a conventional-sized probe made in the same flow, demonstrating that, because of their improved spatial resolution, subminiature sensors can provide more accurate measurements in boundary layers than do the conventional probes.

Ligrani, P. M.↗

Visual-Inspection Probe For Cryogenic Chamber

Visual-inspection probe that resembles borescope enables observer at ambient temperature to view objects immersed in turbulent flow of liquid oxygen, liquid nitrogen, or other cryogenic fluid. Design of probe fairly conventional, except special consideration given to selection of materials and to thermal expansion to provide for expected range of operating temperatures. Penetrates wall of cryogenic chamber to provide view of interior. Similar probe illuminates scene. View displayed on video monitor.

Friend, Steve↗

Electro-optical Probing Of Terahertz Integrated Circuits

Electro-optical probe developed to perform noncontact, nondestructive, and relatively noninvasive measurements of electric fields over broad spectrum at millimeter and shorter wavelengths in integrated circuits. Manipulated with conventional intregrated-circuit-wafer-probing equipment and operated without any special preparation of integrated circuits. Tip of probe small electro-optical crystal serving as proximity electric-field sensor.

Bhasin, K. B.↗

The gravity probe B relativity gyroscope program

The idea of testing general relativity through observations on Earth orbiting gyroscopes was suggested in 1959 to 1960. The direction, it was noted, of spin of a suitably oriented gyroscope should change with respect to the line of sight to a guide star for two reasons: a geodetic effect from the motion of the gyroscope through the curved space-time around the Earth, and a frame-dragging effect from the Earth's rotation. NASA began supporting laboratory research on the experiment, now called Gravity Probe B, in 1964. Technologies for it were progressively established, and an error analysis demonstrated the potential of measuring frame-dragging to 1 to 2 percent and the geodetic effect to 1 part in 10(exp 4). Later analyses, discussed herein, suggest possibilities for further improving those precisions each by a further factor of 10. In 1984, after technical and scientific reviews by the Space Science Board and other bodies, and completion by NASA Marshall Center of a Phase B Study, the NASA Administrator approved the start of a program known as STORE (Shuttle Test Of the Relativity Experiment). The purpose of STORE is to verify the final Gravity Probe B science payload, perform on the Shuttle a 7-day experiment rehearsal (including sophisticated gyro tests in low gravity), and then return the payload to Earth for refurbishment and integration into the Science Mission spacecraft. The payload comprises four gyroscopes, a telescope, and a drag-free proof mass, all mounted in a quartz block assembly within an evacuated magnetically shielded probe, which in turn is inserted into a 10-ft long, 6-ft diameter liquid helium dewar, operating at 1.8 K and maintaining low temperature for 2 years. STORE is manifested on Shuttle OV-105, for launch MSSN 69 in February 1993. The Science Mission is set tentatively for June 1995.

Everitt, C. W. Francis↗

Probing the possibility of a C-12/C-13 galactic abundance gradient

High S/N (equal to or greater than 500) observations of interstellar CH+ with the 3.0 m telescope were performed at Lick Observatory and with the 4.0 m telescope at CTIO, of the reddened, early-type stars HD 183143, HD 24432, and HD 157038 in an effort to probe the existence of a C-12/C-13 abundance gradient in our Galaxy. Previous very high quality optical observations of interstellar CH+ toward five stars within 1 kpc of the Sun have yielded a precise weighted mean C-12/C-13 isotope ratio of 43 plus or minus 4 (1 sigma) (Hawkins, Jura, and Meyer 1985; Hawkins and Jura 1987). The isotope ratios derived toward four lines of sight in the local ISM are uniform within 12 percent. The similarity among these carbon isotope ratios determined in diffuse clouds possessing different physical conditions precludes the possibility that the CH+ molecule is suffering from isotope selective effects in these regions. The precise C-12/C-13 derivable from high quality observations of (12)CH+ and (13)CH+ provide the unique opportunity to probe the homogeneity of the ISM in a large scale and the history of nucleosynthesis in our Galaxy. Since CH+ seems to be the most sensitive probe of C-12/C-13 in the diffuse ISM, observations toward more distant stars located up to 2.5 kpc from the Sun are the best way to study the possibility of a Galactic (C-12/C-13) abundance gradient. The researcher obtained 4232 angstrom data toward all three of the stars mentioned above, 3957 angstrom data toward HD 183143 and HD 157038, and 3745 angstrom data toward HD 157038. Because of the poorer quality of the HD 24432 spectrum, and its weaker CH+ absorption lines, the satellite (13)CH+ line was not detected, and thus only a lower limit on the C-12/C-13 ratio toward this star was obtained. The results obtained from careful reduction and analysis of the data toward these stars in the Northern and Southern Hemispheres are presented.

Hawkins, Isabel↗

Calibration of the Forward Scattering Spectrometer Probe used on the ER-2 during the Airborne Antarctic Ozone Experiment

The Particle Measuring Systems (PMS) Forwared Scattering Spectrometer Probe (FSSP-100) which was flown on the ER-2 during the Airborne Antarctic Ozone Experiment for the measurement of particles in polar stratospheric clouds has been evaluated and calibrated. The sample volume of the probe per 10-s sampling period increases from 257 cu cm for 1-micron particles to 412 for 15-micron particles, but there is substantial uncertainty in this value. Limitations in the measurements from this instrument and possible corrections are discussed. The uncertainty in the total particle mass measured by the probe may be as large as + or - 100 percent. Recommendations are given for the processing of data from the FSSP used in this project.

Baumgardner, Darrel↗

Development of a phase Doppler based probe for icing cloud droplet characterization

The development and evaluation of a compact optical fiber probe (OFP) for airborne and wind tunnel icing cloud characterizations is described. This probe was based upon the proven phase Doppler technique for measuring the size and velocity of spherical drops. Direct comparisons of the size distributions from the standard PDPA with the OFP were used to confirm the reliability of the probe. After some improvements in the fiber coupling efficiency, the number density and liquid water content data agreed to within 15 percent.

Rudoff, R. C.↗

Solar probe mission status

The penetration of coronal regions by a solar probe employing planetary gravity-assist trajectories to attain perihelia of only a few solar radii will allow unique in situ experiments to be conducted. The trajectory design options will fundamentally impact solar probe spacecraft design criteria. The aerogravity-assist method, which requires the bending of a trajectory in the vicinity of a planet by passing through a portion of its atmosphere will yield large changes in direction and velocity. This option would in the case of a solar probe mission involve the use of either the earth or Venus as a target for a specially aerodynamically configured 'waverider' spacecraft with L/D of the order of 10.

Randolph, J. E.↗

The extension of the Cassini spacecraft/Titan probe to the exploration of Neptune/Triton

NASA and ESA are planning a mission named 'Cassini' to place a spacecraft in Saturn orbit and deposit an atmospheric probe into the atmosphere of Titan. It is expected that the upcoming close flyby of Neptune and Triton by Voyager 2 will increase future scientific interest in more intensive exploration of that system. The purpose of this paper is to examine the feasibility of the extension of the Cassini spacecraft and Titan Probe designs to this expected future scientific need for longer-term orbital observations of Neptune and its satellites and for in situ exploration of the suspected Triton atmosphere with a probe vehicle.

Wercinski, Paul F.↗

Contact Probe With Pivoting Tip

Sensor probe follows curved contours, always keeping sensor in contact with contoured surface. Includes freely pivoting tip, which contains sensor. Spring holds tip in contact with surface being scanned. As user moves probe along surface, force of contact keeps tip oriented along local perpendicular to surface. Slopes of up to 90 degrees from axis of probe accommodated.

Amos, Jay M.↗

Probe insertion apparatus with inflatable seal

A sealing apparatus is disclosed for inserting a probe into a pressure vessel having an elongated opening includes a pair of resiliently deformable seals opposingly disposed in sealing engagement with each other. A retainer is connected to the pressure vessel around the elongated opening and holds the pair of seals rigidly to the pressure vessel. A wedge is engageable with the pair of seals and carries the probe, for longitudinally translating the probe in pressure vessel.

Trimarchi, Paul A.↗