Search NASA⌕ Search

SEARCH · Search NASA

Results for “Procedures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

3D numerical investigation of a free-burning argon arc with metal electrodes using a novel sheath coupling procedure

In this study, a novel coupling procedure describing the complicated plasma-electrode interaction process has been developed and applied into the 3D finite volume simulation of a direct current tungsten inert gas (TIG) welding system. This is achieved by making the space charge layer (sheath) incorporated into the computation domain and interact with both bulk plasma and cathode through the effective electrical conductivity. Both chemical and thermal nonequilibrium phenomena as well as the self-induced magnetic fields have been taken into consideration by the model to ensure a realistic numerical description of a non-thermal arc. The applicability of this coupling procedure is further improved by calculating the real electric potential, which is capable of accounting for the effects of the complicated drift and diffusion processes. Numerical results of both 100 and 200A discharge currents are presented, field reversal is obtained at near-anode regions in both cases, which is followed by the negative anode sheath potential drop. The region of the strongest electron overpopulation appears at the intersection of plasma fringes and electrode surface. Finally, numerical results of plasma temperature and voltage show good agreement with experimental measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Regulations and Procedures Manual

The purpose of the Regulations and Procedures Manual (RPM) is to provide LBNL personnel with a reference to University and Lawrence Berkeley National Laboratory (LBNL or Laboratory) policies and regulations by outlining normal practices and answering most policy questions that arise in the day-to-day operations of Laboratory organizations. Much of the information in this manual has been condensed from detail provided in LBNL procedure manuals, Department of Energy (DOE) directives, and Contract DE-AC02-05CH11231. This manual is not intended, however, to replace any of those documents. RPM sections on personnel apply only to employees who are not represented by unions. Personnel policies pertaining to employees represented by unions may be found in their labor agreements. Questions concerning policy interpretation should be directed to the LBNL organization responsible for the particular policy. A link to the Managers Responsible for RPM Sections is available on the RPM home page. If it is not clear which organization is responsible for a policy, please contact Requirements Manager Lydia Young or the RPM Editor.

99 GENERAL AND MISCELLANEOUS↗

Regulations and Procedures Manual

The purpose of the Regulations and Procedures Manual (RPM) is to provide Laboratory personnel with a reference to University and Lawrence Berkeley National Laboratory policies and regulations by outlining the normal practices and answering most policy questions that arise in the day-to-day operations of Laboratory departments. Much of the information in this manual has been condensed from detail provided in Laboratory procedure manuals, Department of Energy (DOE) directives, and Contract DE-AC02-05CH11231. This manual is not intended, however, to replace any of those documents. The sections on personnel apply only to employees who are not represented by unions. Personnel policies pertaining to employees represented by unions may be found in their labor agreements. Questions concerning policy interpretation should be directed to the department responsible for the particular policy. A link to the Managers Responsible for RPM Sections is available on the RPM home page. If it is not clear which department should be called, please contact the Associate Laboratory Director of Operations.

99 GENERAL AND MISCELLANEOUS↗

Standard Operating Procedure for Optimal Deployment of Meteorological Instrumentation Within the Solar Radiation Research Laboratory (BMS and RMS SOP)

The objective of the National Renewable Energy Laboratory's (NREL's) Solar Radiation Research Laboratory (SRRL) is to collect and use high-quality solar radiation data sets for research leading to the widespread adoption of solar technologies. To appropriately populate and track the diverse array of instruments at the NREL-SRRL, NREL has established a Standard Operating Procedure (SOP) for optimal instrument deployment within the SRRL for both the Baseline Measurement System (BMS) and the Research Measurement System (RMS). Using best practices methodologies, the NREL-SRRL maintains a varied and extensive array of solar monitoring equipment to test, evaluate, and characterize the solar sensors used by federal and international agencies as well as the solar industry to determine the solar resource. The SOP provides the industry with guidance for solar resource assessment and is used for procedures in the long-term continuous monitoring of legacy instruments alongside state-of-the-art instruments. Based on the SOP, instruments are annually evaluated for continued deployment. Instruments that do not meet the SOP criteria are decommissioned, and new instruments that meet the criteria are deployed. Streamlining and optimizing the use of this facility ensures that the lab continues to be a world-leading solar calibration and measurement facility.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Determination of Total, Organic, and Inorganic Carbon and Total Nitrogen in Biological Cultures and Liquid Fraction Process Samples: Laboratory Analytical Procedure (LAP)

This Laboratory Analytical Procedure (LAP) describes the quantitative determination of total organic carbon, inorganic carbon in whole suspended biological samples and in the cell-free supernatant, by combustion and CO 2 detection with a non-dispersive infrared (NDIR) detector. This allows for distinct reporting of soluble and insoluble organic and inorganic carbon. In addition, this procedure covers the quantitative determination of soluble nitrogen in the cell-free supernatant.

09 BIOMASS FUELS↗

Standard Operating Procedure for Optimal Deployment of Meteorological Instrumentation Within the Solar Radiation Research Laboratory: 2024 Edition

The objective of the National Renewable Energy Laboratory's (NREL's) Solar Radiation Research Laboratory (SRRL) is to collect and use high-quality solar radiation data sets for research leading to the widespread adoption of solar technologies. To appropriately populate and track the diverse array of instruments at the NREL-SRRL, NREL has established a Standard Operating Procedure (SOP) for optimal instrument deployment within the SRRL for both the Baseline Measurement System (BMS) and the Research Measurement System (RMS). Using best practices methodologies, the NREL-SRRL maintains a varied and extensive array of solar monitoring equipment to test, evaluate, and characterize the solar sensors used by federal and international agencies as well as the solar industry to determine the solar resource. The SOP provides the industry with guidance for solar resource assessment and is used for procedures in the long-term continuous monitoring of legacy instruments alongside state-of-the-art instruments. Based on the SOP, instruments are annually evaluated for continued deployment. Instruments that do not meet the SOP criteria are decommissioned, and new instruments that meet the criteria are deployed. Streamlining and optimizing the use of this facility ensures that the lab continues to be a world-leading solar calibration and measurement facility. This 2024 edition includes updates to the appendices to reflect the instrument changes from one year to another.

14 SOLAR ENERGY↗

Standard Operating Procedure for Optimal Deployment of Meteorological Instrumentation Within the Solar Radiation Research Laboratory: 2025 Edition

The objective of the National Renewable Energy Laboratory's (NREL's) Solar Radiation Research Laboratory (SRRL) is to collect and use high-quality solar radiation data sets for research leading to the widespread adoption of solar technologies. To appropriately populate and track the diverse array of instruments at the NREL-SRRL, NREL has established a Standard Operating Procedure (SOP) for optimal instrument deployment within the SRRL for both the Baseline Measurement System (BMS) and the Research Measurement System (RMS). Using best practices methodologies, the NREL-SRRL maintains a varied and extensive array of solar monitoring equipment to test, evaluate, and characterize the solar sensors used by federal and international agencies as well as the solar industry to determine the solar resource. The SOP provides the industry with guidance for solar resource assessment and is used for procedures in the long-term continuous monitoring of legacy instruments alongside state-of-the-art instruments. Based on the SOP, instruments are annually evaluated for continued deployment. Instruments that do not meet the SOP criteria are decommissioned, and new instruments that meet the criteria are deployed. Streamlining and optimizing the use of this facility ensures that the lab continues to be a world-leading solar calibration and measurement facility. This 2025 edition includes updates to the appendices to describe the current instrumentation of the NREL-SRRL.

14 SOLAR ENERGY↗

UAM Instrument Flight Procedure Design and Evaluation in the Joby Flight Simulator

NASA’s Advanced Air Mobility (AAM) National Campaign (NC) partnered with Joby Aviation to test and evaluate different developmental candidate Urban Air Mobility (UAM) Instrument Flight Procedure (IFP) designs including new departure, enroute, approach and missed approach architectures using Joby’s high-fidelity engineering aircraft simulator. In conjunction with the simulator testing, this effort also evaluated related aspects such as charting, coding, and adherence to flight planning criteria. The test objectives were to assess the safety, efficiency, passenger comfort and noise of the different variations of the developmental IFPs. Safety-related measures include clearance from terrain and vertical obstructions, procedure flyability, and flight path conformance. Efficiency-related measures included time required, airspace volume required, and battery energy required. Passenger comfort and ride quality measures include roll/pitch angles, roll/pitch attitude change rates, and airspeeds prior to aggressive maneuvers, subjective pilot/passenger responses and acceleration forces. The noise impacts of the different IFPs will be interpolated/extrapolated using data from the simulator fed into a separate Joby acoustic software-based tool. Overall, several tradeoffs were identified and characterized between the different variations of the developmental IFP profiles. No single version of the developmental IFP structure scored highest across all measures listed above; rather, different IFP variations proved optimal for different measures, confirming that the best IFP depends on which specific measures are prioritized for a given aircraft, location and operation.

National Campaign↗

A generalized procedure for the prediction of multicomponent adsorption equilibria

Prediction of multicomponent adsorption equilibria has been investigated for several decades. While there are theories available to predict the adsorption behavior of ideal mixtures, there are few purely predictive theories to account for nonidealities in real systems. Most models available for dealing with nonidealities contain interaction parameters that must be obtained through correlation with binary-mixture data. However, as the number of components in a system grows, the number of parameters needed to be obtained increases exponentially. Here, a generalized procedure is proposed, as an extension of the predictive real adsorbed solution theory, for determining the parameters of any activity model, for any number of components, without correlation. This procedure is then combined with the adsorbed solution theory to predict the adsorption behavior of mixtures. As this method can be applied to any isotherm model and any activity model, it is referred to as the generalized predictive adsorbed solution theory.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of Hepatic Angiography Procedures and Bremsstrahlung Imaging in Selective Internal Radiation Therapy: A Two-Year Single-Center Experience

The imaging of Bremsstrahlung radiation is performed after hepatic radioembolization to assess the distribution of the injected radioactive material. This review assesses the role of Bremsstrahlung imaging and its relation to the angiographic procedure and technique in hepatic selective internal radiation therapy on 21 patients undergoing this procedure at a single center.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Microcatheter Use for Difficult Percutaneous Biliary Procedures

Percutaneous biliary drainage procedures in patients with nondilated ducts are demanding, resulting in lower success rates than in patients with bile duct dilatation. Pertinent clinical settings include patients with iatrogenic bile leaks, diffuse cholangiocarcinomas, and sclerosing cholangitis. We describe a method to facilitate these procedures with the combined use of a 2.7-Fr microcatheter and a 0.018-in. hydrophilic wire.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transient Encephalopathy from Angiographic Contrast: A Rare Complication in Neurointerventional Procedures

Neurotoxicity from contrast media used in angiography is a rare complication from these procedures. The infrequency with which it is encountered makes it a diagnostic challenge. We present the case of a 51-year-old male who, 30 min after successful angiography for treatment of a right carotid-ophthalmic fusiform aneurysm with a stent, developed psychomotor agitation, disorientation, and progressive left faciobrachial hemiparesis (4/5). An emergency nonenhanced CT showed marked cortical enhancement and edema in the right cerebral hemisphere. Cortical enhancement is thought to be secondary to contrast extravasation due to disruption of the blood-brain barrier. Angiography was performed immediately, without any pathologic findings. After this procedure there was an increase in the left faciobrachial hemiparesis (3/5), right gaze deviation, Gerstmann syndrome, and left anosognosia and left homonymous hemianopsia. Endovenous dexamethasone and mannitol were initiated. Twenty-four hours later an MRI showed no signs of acute infarct, just gyriform signal increase in the right cerebral hemisphere on FLAIR and a decrease in the edema observed before. The patient had progressive improvement of his neurological deficit. A control MRI done 5 days later was normal. The patient recovered completely and was discharged. This rare entity should be kept in mind but diagnosed only when all other causes have been ruled out, because more important and frequent causes, such as acute infarct, must be excluded promptly.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Glove Perforations During Interventional Radiological Procedures

Intact surgical gloves are essential to avoid contact with blood and other body fluids. The objective of this study was to estimate the incidence of glove perforations during interventional radiological procedures. In this study, a total of 758 gloves used in 94 interventional radiological procedures were examined for perforations. Eleven perforations were encountered, only one of which was of occult type. No significant difference in the frequency of glove perforation was found between the categories with varying time duration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Microwave Ablation of Porcine Kidneys in vivo: Effect of two Different Ablation Modes ('Temperature Control' and 'Power Control') on Procedural Outcome

Purpose: This study was designed to analyze the effect of two different ablation modes ('temperature control' and 'power control') of a microwave system on procedural outcome in porcine kidneys in vivo. Methods: A commercially available microwave system (Avecure Microwave Generator; MedWaves, San Diego, CA) was used. The system offers the possibility to ablate with two different ablation modes: temperature control and power control. Thirty-two microwave ablations were performed in 16 kidneys of 8 pigs. In each animal, one kidney was ablated twice by applying temperature control (ablation duration set point at 60 s, ablation temperature set point at 96 Degree-Sign C, automatic power set point; group I). The other kidney was ablated twice by applying power control (ablation duration set point at 60 s, ablation temperature set point at 96 Degree-Sign C, ablation power set point at 24 W; group II). Procedural outcome was analyzed: (1) technical success (e.g., system failures, duration of the ablation cycle), and (2) ablation geometry (e.g., long axis diameter, short axis diameter, and circularity). Results: System failures occurred in 0% in group I and 13% in group II. Duration of the ablation cycle was 60 {+-} 0 s in group I and 102 {+-} 21 s in group II. Long axis diameter was 20.3 {+-} 4.6 mm in group I and 19.8 {+-} 3.5 mm in group II (not significant (NS)). Short axis diameter was 10.3 {+-} 2 mm in group I and 10.5 {+-} 2.4 mm in group II (NS). Circularity was 0.5 {+-} 0.1 in group I and 0.5 {+-} 0.1 in group II (NS). Conclusions: Microwave ablations performed with temperature control showed fewer system failures and were finished faster. Both ablation modes demonstrated no significant differences with respect to ablation geometry.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Protective Embolization of the Gastroduodenal Artery with a One-HydroCoil Technique in Radioembolization Procedures

Protective occlusion of the gastroduodenal artery (GDA) is required to avoid severe adverse effects and complications in radioembolization procedures. Because of the expandable features of HydroCoils, our goal was to occlude the GDA with only one HydroCoil to provide particle reflux protection. Twenty-three subjects with unresectable liver tumors, who were scheduled for protective occlusion of the GDA before radioembolization therapy, were included. The primary end point was to achieve a proximal occlusion of the GDA with only one detachable HydroCoil. Evaluated parameters were duration of deployment, and early (during the intervention) and late (7-21 days) occlusion rates of GDA. Secondary end points included complete duration of the intervention, amount of contrast medium used, fluoroscopy rates, and adverse effects. In all cases, the GDA was successfully occluded with only one HydroCoil. The selected diameter/length range was 4/10 mm in 2 patients, 4/15 mm in 6 patients, and 4/20 mm in 15 patients. HydroCoils were implanted, on average, 3.75 mm from the origin of the GDA (range 1.5-6.8 mm), with an average deployment time of 2:47 (median 2:42, range 2:30-3:07) min. In 21 (91%) of 23 patients, a complete occlusion of the GDA was achieved during the first 30 min after the coil implantation; however, in all patients, a late occlusion of the GDA was present after 6 to 29 days. No clinical or technical complications were reported. We demonstrated that occlusion of the GDA with a single HydroCoil is a safe procedure and successfully prevents extrahepatic embolization before radioembolization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Management of Accidentally Retained Foreign Bodies During Image-Guided Non-vascular Procedures: Novel Technique Using a Large-Bore Biopsy System

ObjectiveTo describe a novel percutaneous image-guided technique using a large-bore biopsy system to retrieve foreign bodies (FBs) accidentally retained during non-vascular interventional procedures.Materials and MethodsBetween May 2013 and October 2015, five patients underwent percutaneous retrieval of five iatrogenic FBs, including a biopsy needle tip in the femoral head following osteoblastoma biopsy and radiofrequency ablation (RFA); a co-axial needle shaft within a giant desmoid tumour following cryoablation; and three post-vertebroplasty cement tails within paraspinal muscles. All FBs were retrieved immediately following original procedures under local or general anaesthesia, using combined computed tomography (CT) and fluoroscopic guidance. The basic technique involved positioning a 6G trocar sleeve around the FB long axis and co-axially advancing an 8G biopsy needle to retrieve the FB within the biopsy core. Retrospective chart review facilitated analysis of procedures, FBs, technical success, and complications.ResultsMean FB size was 23 mm (range 8–74 mm). Four FBs were located within 10 mm of non-vascular significant anatomic structures. The basic technique was successful in 3 cases; 2 cases required technical modifications including using a stiff guide-wire to facilitate retrieval in the case of the post-cryoablation FB; and using the central mandrin of the 6G trocar to push a cement tract back into an augmented vertebra when initial retrieval failed. Overall technical success (FB retrieval or removal to non-hazardous location) was 100 %, with no complications.ConclusionPercutaneous image-guided retrieval of iatrogenic FBs using a large-bore biopsy system is a feasible, safe, effective, and versatile technique, with potential advantages over existing methods.

62 RADIOLOGY AND NUCLEAR MEDICINE↗