Search NASA⌕ Search

SEARCH · Search NASA

Results for “QUALITY FACTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Mirror smooth superconducting RF cavities by mechanical polishing with minimal acid use

A new mechanical technique for polishing the inside surface of niobium superconducting RF (SRF) cavities has been developed. Mirror-like finishes, the smoothest observed in cavities so far, were produced after fine polishing, with < 15 nm RMS roughness over 1 mm{sup 2} scan area. This is an order of magnitude less than the typical roughness produced by electropolishing. The processing equipment has advantages of modest installed and operating costs, simple associated technology, and no large quantities of acutely toxic chemicals or special handling procedures. Cavity quality factors above 10{sup 10} were maintained well above the 35 MV m{sup -1} benchmark for electropolished cavities, and this was achieved with an intermediate finish not as smooth as the final polish. Repair of a weld defect, which is intrinsic to this process, was also demonstrated. These transformational aspects could enable a new SRF cavity processing paradigm for future large scale particle accelerators such as the International Linear Collider.

43 PARTICLE ACCELERATORS↗

Piezoelectric properties of K{sub 4}CuNb{sub 8}O{sub 23} modified (Na{sub 0.5}K{sub 0.5})NbO{sub 3} lead-free piezoceramics

Dense K{sub 4}CuNb{sub 8}O{sub 23} modified (Na{sub 0.5}K{sub 0.5})NbO{sub 3} (NKN:KCN) ceramics were synthesized by using conventional oxide mixing process. The maximum mechanical quality factor Q{sub m} of NKN:KCN ceramics reaches up to 1150, the piezoelectric constant d{sub 33} and the planar electromechanical coefficient k{sub p} still maintain relatively high levels, which are about 100 pC/N and 40%, respectively. Middle frequency (455 kHz) lead-free resonators were fabricated by using NKN:KCN, and remarkable improvements in resonance characteristics were found by KCN doping.

36 MATERIALS SCIENCE↗

Near-infrared gallium nitride two-dimensional photonic crystal platform on silicon

We demonstrate a two-dimensional free-standing gallium nitride photonic crystal platform operating around 1550 nm and fabricated on a silicon substrate. Width-modulated waveguide cavities are integrated and exhibit loaded quality factors up to 34 000 at 1575 nm. We show the resonance tunability by varying the ratio of air hole radius to periodicity, and cavity hole displacement. We deduce a ∼7.9 dB/cm linear absorption loss for the suspended nitride structure from the power dependence of the cavity in-plane transmission.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Progress of ILC High Gradient SRF Cavity R&D at Jefferson Lab

Latest progress of ILC high gradient SRF cavity R&D at Jefferson Lab will be presented. 9 out of 10 real 9-cell cavities reached an accelerating gradient of more than 38 MV/m at a unloaded quality factor of more than 8 {center_dot} 109. New understandings of quench limitation in 9-cell cavities are obtained through instrumented studies of cavities at cryogenic temperatures. Our data have shown that present limit reached in 9-cell cavities is predominantly due to localized defects, suggesting that the fundamental material limit of niobium is not yet reached in 9-cell cavities and further gradient improvement is still possible. Some examples of quench-causing defects will be given. Possible solutions to pushing toward the fundamental limit will be described.

43 PARTICLE ACCELERATORS↗

Long range B-site cation ordering and Briet–Wigner–Fano line shape of A{sub 1g}-like Raman mode in Nd{sub 1−x}Sm{sub x}(Mg{sub 0.5}Ti{sub 0.5})O{sub 3} microwave dielectric ceramics

Graphical abstract: Display Omitted Highlights: ► Q × f of Nd{sub 1–x}Sm{sub x}(Mg{sub 0.5}Ti{sub 0.5})O{sub 3} are correlated with B-site cation ordering (LRO). ► Correlation between LRO and Γ of A{sub 1g}-like mode in Raman spectrum is observed. ► Reason for asymmetry in A{sub 1g}-like Raman mode in these materials is revealed. ► Briet–Wigner–Fano resonance is confirmed with temperature variation in Raman spectra. -- Abstract: Nd{sub 1−x}Sm{sub x}(Mg{sub 0.5}Ti{sub 0.5})O{sub 3} (x = 0.0–1.0) samples were prepared by solid-state reaction method. Rietveld refinement of X-ray diffraction data was done using P2{sub 1}/n space group with monoclinic symmetry, which supports 1:1 B-site cation ordering. Long range ordering (LRO) parameter decreased up to x = 0.5 and then found to increase with further increase in Sm concentration. The A{sub 1g}-like mode in Raman spectra was observed to possess Briet–Wigner–Fano line shape. The variation in obtained line width of the A{sub 1g}-like mode supported LRO. Microwave dielectric characteristics such as dielectric constant (ε{sub r}), quality factor (Q) and temperature coefficient of resonant frequency (τ{sub f}) were measured in the range of 7–9 GHz. ε{sub r} decreased from 26.5 to 24.9 and τ{sub f} become less negative from −58 ppm/°C to −36 ppm/°C with increase in Sm concentration. Q × f decreased from 47,500 GHz (for x = 0) to 39,800 GHz (for x = 0.5) and then increased to 44,600 GHz (for x = 1).

36 MATERIALS SCIENCE↗

Uncertainty in least-squares fits to the thermal noise spectra of nanomechanical resonators with applications to the atomic force microscope

Thermal noise spectra of nanomechanical resonators are used widely to characterize their physical properties. These spectra typically exhibit a Lorentzian response, with additional white noise due to extraneous processes. Least-squares fits of these measurements enable extraction of key parameters of the resonator, including its resonant frequency, quality factor, and stiffness. Here, we present general formulas for the uncertainties in these fit parameters due to sampling noise inherent in all thermal noise spectra. Good agreement with Monte Carlo simulation of synthetic data and measurements of an Atomic Force Microscope (AFM) cantilever is demonstrated. These formulas enable robust interpretation of thermal noise spectra measurements commonly performed in the AFM and adaptive control of fitting procedures with specified tolerances.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Composite arrays of superconducting microstrip line resonators

A novel design of an array of half-wave superconductive microstrip resonators is described. The resonator is intended to be useful for electron spin resonance studies of thin film samples at cryogenic temperatures. It achieves a high quality factor, has a small mode-volume, and creates a uniform magnetic field in a plane above the resonator. The device is made of thin film Niobium on sapphire wafer and is tested with a static magnetic field. Variation of Q-factor versus the magnetic field's strength at different temperatures is reported and is in a good agreement with simulation when the loss due to the vortices is included. Also, the power-dependence response of the resonator is shown in experiments and is verified by capturing the nonlinearity associated with the surface impedance of the superconducting film into the circuit model of the device.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High-Q contacted ring microcavities with scatterer-avoiding “wiggler” Bloch wave supermode fields

High-Q ring resonators with contacts to the waveguide core provide a versatile platform for various applications in chip-scale optomechanics, thermo-, and electro-optics. We propose and demonstrate azimuthally periodic contacted ring resonators based on multi-mode Bloch matching that support contacts on both the inner and outer radius edges with small degradation to the optical quality factor (Q). Radiative coupling between degenerate modes of adjacent radial spatial order leads to imaginary frequency (Q) splitting and a scatterer avoiding high-Q “wiggler” supermode field. We experimentally measure Qs up to 258 000 in devices fabricated in a silicon device layer on buried oxide undercladding and up to 139 000 in devices fully suspended in air using an undercut step. Wiggler supermodes are true modes of the microphotonic system that offer additional degrees of freedom in electrical, thermal, and mechanical design.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

146.4 W end-pumped Ho : YAG slab laser with two crystals

We report a high-power two-crystal Ho : YAG slab laser. A maximum cw output power of 146.4 W at a wavelength of 2090.7 nm is achieved, corresponding to a slope efficiency of 66.0% and an optical efficiency of 61.2%. The beam quality factor is measured to be M{sup 2} < 2.2 at different output power levels. With an acousto-optic Q-switch, a maximum average output power of 141.3, 137.7 and 134.5 W are obtained at pulse repetition rates of 20, 30 and 50 kHz, respectively. Minimum pulse widths of 39 ns, 44 ns and 74 ns are achieved for the above pulse repetition rates. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Observation of whispering gallery modes in nonpolar m-plane GaN microdisks

We have fabricated nonpolar GaN/InGaN microdisks using band-gap selective photoelectrochemical etching. These microdisks have a smoother optical cavity than our previous c-plane microdisks, and they support whispering gallery modes with quality factors as high as 2000 after a focused ion beam treatment to the quantum wells. Because of the lack of a Stokes shift in the quantum wells of these m-plane disks, absorption losses play a much more significant role than in our earlier c-plane microdisks, and the light which couples into the modes is emission from the InGaN post rather than the quantum wells within the cavity.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A self-calibrating optomechanical force sensor with femtonewton resolution

We report the development of an ultrasensitive optomechanical sensor designed to improve the accuracy and precision of force measurements with atomic force microscopy. The sensors reach quality factors of 4.3 × 10{sup 6} and force resolution on the femtonewton scale at room temperature. Self-calibration of the sensor is accomplished using radiation pressure to create a reference force. Self-calibration enables in situ calibration of the sensor in extreme environments, such as cryogenic ultra-high vacuum. The senor technology presents a viable route to force measurements at the atomic scale with uncertainties below the percent level.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Composition dependent spectroscopic properties of Nd{sup 3+} doped sodium lead borate glasses

Nd{sup 3+} doped oxide glasses of the type xNa{sub 2}O–30 PbO–(69.5-x) B{sub 2}O{sub 3}–0.5Nd{sub 2}O{sub 3} were prepared and investigated for physical and spectroscopic properties. Optical absorption spectra and Judd-Ofelt theory has been used to determine the oscillator strengths and the intensity parameters Ω{sub λ} (λ=2, 4, 6). The radiative transition probability (A), radiative lifetime (τ{sub R}) and branching ratio (β{sub R}) for the fluorescent levels of Nd{sup 3+} in the prepared glasses have been determined. The lasing efficiency of the prepared glasses has been characterized by the spectroscopic quality factor (Ω{sub 4} / Ω{sub 6}), the value of which is in the range 0.2-1.5, typical for Nd{sup 3+} in different laser hosts. The radiative transition probability of the potential lasing transition {sup 4}F{sub 3/2} → {sup 4}I{sub 11/2} of Nd{sup 3+} ions is found to increase with increase in content of Na{sub 2}O.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Low Threshold Lasing in InP/GaInP Quantum Dot Microdisks

We report a realization of room temperature lasing threshold of 1 μW in GaInP microdisk containing a few self-aggregated InP/GaInP quantum dots (QDs) grown by metal-organic vapor phase epitaxy. InP/GaInP QD microdisk cavities emitting in the spectral range of 700–800 nm and having the size of ~2 μm, free spectral range of ~35 nm and quality factors Q ~ 4000 were formed by wet chemical etching. Low dot density (~2 μm{sup –2}) and large dot size (~150 nm), suggesting a single dot lasing and maximum overlap of QD and cavity mode, were achieved using deposition of 3 ML of InP layer at 700°C.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development of Thermal Kinetic Inductance Detectors Suitable for X-ray Spectroscopy

We report on the development of thermal kinetic inductance detectors (TKIDs) suitable to perform X-ray spectroscopy measurements. The aim is to implement MKIDs sensors working in thermal quasi-equilibrium mode to detect X-ray photons as pure calorimeters. The thermal mode is a variation on the MKID classical way of operation that has generated interest in recent years. TKIDs can offer the MKIDs inherent multiplexibility in the frequency domain, a high spatial resolution comparable with CCDs, and an energy resolution theoretically limited only by thermodynamic fluctuations across the thermal weak links. Microresonators are built in Ti/TiN multilayer technology with the inductive part thermally coupled with a metal absorber on a suspended SiN membrane, to avoid escape of phonons from the film to the substrate. The mid-term goal is to optimize the single-pixel design in terms of superconducting critical temperatures, internal quality factors, kinetic inductance and spectral energy resolution. The final goal is to realize a demonstrator array for a next generation thousand pixels X-ray spectrometer. In this contribution, the status of the project after one year of developments is reported, with detailed reference to the microresonators design and simulations and to the fabrication process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Silicon technology compatible photonic molecules for compact optical signal processing

Photonic molecules (PMs) based on multiple inner coupled microring resonators allow to surpass the fundamental constraint between the total quality factor (Q{sub T}), free spectral range (FSR), and resonator size. In this work, we use a PM that presents doublets and triplets resonance splitting, all with high Q{sub T}. We demonstrate the use of the doublet splitting for 34.2 GHz signal extraction by filtering the sidebands of a modulated optical signal. We also demonstrate that very compact optical modulators operating 2.75 times beyond its resonator linewidth limit may be obtained using the PM triplet splitting, with separation of ∼55 GHz.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Curious Case of KOI 4: Confirming Kepler’s First Exoplanet Detection

The discovery of thousands of planetary systems by Kepler has demonstrated that planets are ubiquitous. However, a major challenge has been the confirmation of Kepler planet candidates, many of which still await confirmation. One of the most enigmatic examples is KOI 4.01, Kepler’s first discovered planet candidate detection (as KOI 1.01, 2.01, and 3.01 were known prior to launch). Here we present the confirmation and characterization of KOI 4.01 (now Kepler-1658), using a combination of asteroseismology and radial velocities. Kepler-1658 is a massive, evolved subgiant (M {sub ⋆} = 1.45 ± 0.06 M {sub ⊙}, R {sub ⋆} = 2.89 ± 0.12 R {sub ⊙}) hosting a massive (M{sub p} = 5.88 ± 0.47 M{sub J}, R{sub p} = 1.07 ± 0.05 R{sub J}) hot Jupiter that orbits every 3.85 days. Kepler-1658 joins a small population of evolved hosts with short-period (≤100 days) planets and is now the closest known planet in terms of orbital period to an evolved star. Because of its uniqueness and short orbital period, Kepler-1658 is a new benchmark system for testing tidal dissipation and hot Jupiter formation theories. Using all four years of the Kepler data, we constrain the orbital decay rate to be P-dot ≤ −0.42 s yr{sup −1}, corresponding to a strong observational limit of Q{sub ⋆}{sup ′} ≥ 4.826 × 10{sup 3} for the tidal quality factor in evolved stars. With an effective temperature of T{sub eff} ∼ 6200 K, Kepler-1658 sits close to the spin–orbit misalignment boundary at ∼6250 K, making it a prime target for follow-up observations to better constrain its obliquity and to provide insight into theories for hot Jupiter formation and migration.

79 ASTRONOMY AND ASTROPHYSICS↗

Electromagnetic model for near-field microwave microscope with atomic resolution: Determination of tunnel junction impedance

An electrodynamic model is proposed for the tunneling microwave microscope with subnanometer space resolution as developed by Lee et al. [Appl. Phys. Lett. 97, 183111 (2010)]. Tip-sample impedance Z{sub a} was introduced and studied in the tunneling and non-tunneling regimes. At tunneling breakdown, the microwave current between probe and sample flows along two parallel channels characterized by impedances Z{sub p} and Z{sub t} that add up to form overall impedance Z{sub a}. Quantity Z{sub p} is the capacitive impedance determined by the near field of the probe and Z{sub t} is the impedance of the tunnel junction. By taking into account the distance dependences of effective tip radius r{sub 0}(z) and tunnel resistance R{sub t}(z) = Re[Z{sub t}(z)], we were able to explain the experimentally observed dependences of resonance frequency f{sub r}(z) and quality factor Q{sub L}(z) of the microscope. The obtained microwave resistance R{sub t}(z) and direct current tunnel resistance R{sub t}{sup dc}(z) exhibit qualitatively similar behavior, although being largely different in both magnitude and the characteristic scale of height dependence. Interpretation of the microwave images of the atomic structure of test samples proved possible by taking into account the inductive component of tunnel impedance ImZ{sub t} = ωL{sub t}. Relation ωL{sub t}/R{sub t} ≈ 0.235 was obtained.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Sensitivity of optical mass sensor enhanced by optomechanical coupling

Optical mass sensors based on cavity optomechanics employ radiation pressure force to drive mechanical resonator whose mechanical susceptibility can be described by nonlinear optical transmission spectrum. In this paper, we present an optical mass sensor based on a two-cavity optomechanical system where the mechanical damping rate can be decreased by adjusting a pump power so that the mass sensitivity which depends on the mechanical quality factor has been enhanced greatly. Compared with that of an optical mass sensor based on single-cavity optomechanics, the mass sensitivity of the optical mass sensor is improved by three orders of magnitude. This is an approach to enhance the mass sensitivity by means of optomechanical coupling, which is suitable for all mass sensor based on cavity optomechanics. Finally, we illustrate the accurate measurement for the mass of a few chromosomes, which can be achieved based on the current experimental conditions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗