Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

A Phase II Study of Submandibular Gland Transfer Prior to Radiation for Prevention of Radiation-induced Xerostomia in Head-and-Neck Cancer (RTOG 0244)

Purpose: We report the results of a phase II study to determine the reproducibility of a submandibular salivary gland transfer (SGT) surgical technique for prevention of radiation (XRT)-induced xerostomia in a multi-institutional setting and to assess severity of xerostomia. Methods and Materials: Eligible patients had surgery for primary, neck dissection, and SGT, followed by XRT, during which the transferred salivary gland was shielded. Intensity modulated radiation therapy, amifostine, and pilocarpine were not allowed, but postoperative chemotherapy was allowed. Each operation was reviewed by 2 reviewers and radiation by 1 reviewer. If 13 or more (of 43) were 'not per protocol,' then the technique would be considered not reproducible as per study design. The secondary endpoint was the rate of acute xerostomia, grade 2 or higher, and a rate of {<=}51% was acceptable. Results: Forty-four of the total 49 patients were analyzable: male (81.8%), oropharynx (63.6%), stage IV (61.4%), median age 56.5 years. SGT was 'per protocol' or within acceptable variation in 34 patients (77.3%) and XRT in 79.5%. Nine patients (20.9%) developed grade 2 acute xerostomia; 2 had grade 0-1 xerostomia (4.7%) but started on amifostine/pilocarpine. Treatment for these 11 patients (25.6%) was considered a failure for the xerostomia endpoint. Thirteen patients died; median follow-up for 31 surviving patients was 2.9 years. Two-year overall and disease-free survival rates were 76.4% and 71.7%, respectively. Conclusions: The technique of submandibular SGT is reproducible in a multicenter setting. Seventy-four percent of patients were prevented from XRT-induced acute xerostomia.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Implementation of Remote 3-Dimensional Image Guided Radiation Therapy Quality Assurance for Radiation Therapy Oncology Group Clinical Trials

Purpose: To report the process and initial experience of remote credentialing of three-dimensional (3D) image guided radiation therapy (IGRT) as part of the quality assurance (QA) of submitted data for Radiation Therapy Oncology Group (RTOG) clinical trials; and to identify major issues resulting from this process and analyze the review results on patient positioning shifts. Methods and Materials: Image guided radiation therapy datasets including in-room positioning CT scans and daily shifts applied were submitted through the Image Guided Therapy QA Center from institutions for the IGRT credentialing process, as required by various RTOG trials. A centralized virtual environment is established at the RTOG Core Laboratory, containing analysis tools and database infrastructure for remote review by the Physics Principal Investigators of each protocol. The appropriateness of IGRT technique and volumetric image registration accuracy were evaluated. Registration accuracy was verified by repeat registration with a third-party registration software system. With the accumulated review results, registration differences between those obtained by the Physics Principal Investigators and from the institutions were analyzed for different imaging sites, shift directions, and imaging modalities. Results: The remote review process was successfully carried out for 87 3D cases (out of 137 total cases, including 2-dimensional and 3D) during 2010. Frequent errors in submitted IGRT data and challenges in the review of image registration for some special cases were identified. Workarounds for these issues were developed. The average differences of registration results between reviewers and institutions ranged between 2 mm and 3 mm. Large discrepancies in the superior-inferior direction were found for megavoltage CT cases, owing to low spatial resolution in this direction for most megavoltage CT cases. Conclusion: This first experience indicated that remote review for 3D IGRT as part of QA for RTOG clinical trials is feasible and effective. The magnitude of registration discrepancy between institution and reviewer was presented, and the major issues were investigated to further improve this remote evaluation process.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Chromosome Damage and Cell Proliferation Rates in In Vitro Irradiated Whole Blood as Markers of Late Radiation Toxicity After Radiation Therapy to the Prostate

Purpose: In vitro irradiated blood samples from prostate cancer patients showing late normal tissue damage were examined for lymphocyte response by measuring chromosomal aberrations and proliferation rate. Methods and Materials: Patients were selected from a randomized trial evaluating the optimal timing of dose-escalated radiation and short-course androgen deprivation therapy. Of 438 patients, 3% experienced grade 3 late radiation proctitis and were considered to be radiosensitive. Blood samples were taken from 10 of these patients along with 20 matched samples from patients with grade 0 proctitis. The samples were irradiated at 6 Gy and, along with control samples, were analyzed for dicentric chromosomes and excess fragments per cell. Cells in first and second metaphase were also enumerated to determine the lymphocyte proliferation rate. Results: At 6 Gy, there were statistically significant differences between the radiosensitive and control cohorts for 3 endpoints: the mean number of dicentric chromosomes per cell (3.26 ± 0.31, 2.91 ± 0.32; P=.0258), the mean number of excess fragments per cell (2.27 ± 0.23, 1.43 ± 0.37; P<.0001), and the proportion of cells in second metaphase (0.27 ± 0.10, 0.46 ± 0.09; P=.0007). Conclusions: These results may be a valuable indicator for identifying radiosensitive patients and for tailoring radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Two-Year and Lifetime Cost-Effectiveness of Intensity Modulated Radiation Therapy Versus 3-Dimensional Conformal Radiation Therapy for Head-and-Neck Cancer

Purpose: To assess the cost-effectiveness of intensity modulated radiation therapy (IMRT) versus 3-dimensional conformal radiation therapy (3D-CRT) in the treatment of head-and neck-cancer (HNC). Methods and Materials: We used a Markov model to simulate radiation therapy-induced xerostomia and dysphagia in a hypothetical cohort of 65-year-old HNC patients. Model input parameters were derived from PARSPORT (CRUK/03/005) patient-level trial data and quality-of-life and Medicare cost data from published literature. We calculated average incremental cost-effectiveness ratios (ICERs) from the US health care perspective as cost per quality-adjusted life-year (QALY) gained and compared our ICERs with current cost-effectiveness standards whereby treatment comparators less than $50,000 per QALY gained are considered cost-effective. Results: In the first 2 years after initial treatment, IMRT is not cost-effective compared with 3D-CRT, given an average ICER of $101,100 per QALY gained. However, over 15 years (remaining lifetime on the basis of average life expectancy of a 65-year-old), IMRT is more cost-effective at $34,523 per QALY gained. Conclusion: Although HNC patients receiving IMRT will likely experience reduced xerostomia and dysphagia symptoms, the small quality-of-life benefit associated with IMRT is not cost-effective in the short term but may be cost-effective over a patient's lifetime, assuming benefits persist over time and patients are healthy and likely to live for a sustained period. Additional data quantifying the long-term benefits of IMRT, however, are needed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prospective Study of Local Control and Late Radiation Toxicity After Intraoperative Radiation Therapy Boost for Early Breast Cancer

Purpose: To report the local recurrence rate and late toxicity of intraoperative radiation therapy (IORT) boost to the tumor bed using the Intrabeam System followed by external-beam whole-breast irradiation (WBI) in women with early-stage breast cancer in a prospective single-institution study. Methods and Materials: Women with breast cancer ≤3 cm were recruited between February 2003 and May 2005. After breast-conserving surgery, a single dose of 5 Gy IORT boost was delivered using 50-kV x-rays to a depth of 10 mm from the applicator surface. This was followed by WBI to a total dose of 50 Gy in 25 fractions. Patients were reviewed at regular, predefined intervals. Late toxicities were recorded using the Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer Late Radiation Morbidity Scoring systems. Results: Fifty-five patients completed both IORT boost and external-beam WBI. Median follow-up was 3.3 years (range, 1.4-4.1 years). There was no reported locoregional recurrence or death. One patient developed distant metastases. Grade 2 and 3 subcutaneous fibrosis was detected in 29 (53%) and 8 patients (15%), respectively. Conclusions: The use of IORT as a tumor bed boost using kV x-rays in breast-conserving therapy was associated with good local control but a clinically significant rate of grade 2 and 3 subcutaneous fibrosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Combined Ventilation and Perfusion Imaging Correlates With the Dosimetric Parameters of Radiation Pneumonitis in Radiation Therapy Planning for Lung Cancer

Purpose: The purpose of this study was to prospectively investigate clinical correlations between dosimetric parameters associated with radiation pneumonitis (RP) and functional lung imaging. Methods and Materials: Functional lung imaging was performed using four-dimensional computed tomography (4D-CT) for ventilation imaging, single-photon emission computed tomography (SPECT) for perfusion imaging, or both (V/Q-matched region). Using 4D-CT, ventilation imaging was derived from a low attenuation area according to CT numbers below different thresholds (vent-860 and -910). Perfusion imaging at the 10th, 30th, 50th, and 70th percentile perfusion levels (F10-F70) were defined as the top 10%, 30%, 50%, and 70% hyperperfused normal lung, respectively. All imaging data were incorporated into a 3D planning system to evaluate correlations between RP dosimetric parameters (where fV20 is the percentage of functional lung volume irradiated with >20 Gy, or fMLD, the mean dose administered to functional lung) and the percentage of functional lung volume. Radiation pneumonitis was evaluated using Common Terminology Criteria for Adverse Events version 4.0. Statistical significance was defined as a P value of <.05. Results: Sixty patients who underwent curative radiation therapy were enrolled (48 patients for non-small cell lung cancer, and 12 patients for small cell lung cancer). Grades 1, 2, and ≥3 RP were observed in 16, 44, and 6 patients, respectively. Significant correlations were observed between the percentage of functional lung volume and fV20 (r=0.4475 in vent-860 and 0.3508 in F30) or fMLD (r=0.4701 in vent-860 and 0.3128 in F30) in patients with grade ≥2 RP. F30∩vent-860 results exhibited stronger correlations with fV20 and fMLD in patients with grade ≥2 (r=0.5509 in fV20 and 0.5320 in fMLD) and grade ≥3 RP (r=0.8770 in fV20 and 0.8518 in fMLD). Conclusions: RP dosimetric parameters correlated significantly with functional lung imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Precision Oncology and Genomically Guided Radiation Therapy: A Report From the American Society for Radiation Oncology/American Association of Physicists in Medicine/National Cancer Institute Precision Medicine Conference

To summarize important talking points from a 2016 symposium focusing on real-world challenges to advancing precision medicine in radiation oncology, and to help radiation oncologists navigate the practical challenges of precision, radiation oncology.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Health-Related Quality of Life Outcomes in Head and Neck Cancer: Results From a Prospective, Real-World Data Study With Brazilian Patients Treated With Intensity Modulated Radiation Therapy, Conformal and Conventional Radiation Techniques

To compare global health-related quality of life (HRQoL) and overall survival (OS) in patients with head and neck cancer treated with intensity modulated radiation therapy (IMRT), conformal radiation therapy (3DCRT) or conventional radiation therapy (2DRT).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparative Effectiveness Analysis of 3D-Conformal Radiation Therapy Versus Intensity Modulated Radiation Therapy (IMRT) in a Prospective Multicenter Cohort of Patients With Breast Cancer

Simple intensity modulation of radiation therapy reduces acute toxicity compared with 2-dimensional techniques in adjuvant breast cancer treatment, but it remains unknown whether more complex or inverse-planned intensity modulated radiation therapy (IMRT) offers an advantage over forward-planned, 3-dimensional conformal radiation therapy (3DCRT).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Local radiative feedbacks over the Arctic based on observed short-term climate variations

We compare various radiative feedbacks in response to short-term climate variations estimated from reanalysis, satellite, and global climate model datasets using the combined Kernel-Gregory approach over the Arctic (60-90°N). Except for the shortwave cloud feedback, all feedbacks are positive over the Arctic. Lapse rate feedback is comparable with surface albedo feedback. Relative to the tropics (30°S-30°N), the temperature feedback (lapse rate feedback plus Planck feedback deviation from its global mean) is the largest contributor to Arctic amplification among all feedbacks, followed by surface albedo feedback. The choice of meteorological fields has a small impact on the cloud feedback estimate, but different top-of-the-atmosphere clear-sky fluxes datasets can result in a wide spread of estimated cloud feedbacks. The net cloud feedback over the Arctic is positive due to a larger positive in longwave than the negative shortwave feedback, but has the largest uncertainty. Relative to the tropics, the longwave cloud feedback largely contributes to the Arctic amplification.

Zhang, Rudong↗

Superior radiation-resistant nanoengineered austenitic 304L stainless steel for applications in extreme radiation environments

Nuclear energy provides more than 10% of electrical power internationally, and the increasing engagement of nuclear energy is essential to meet the rapid worldwide increase in energy demand. A paramount challenge in the development of advanced nuclear reactors is the discovery of advanced structural materials that can endure extreme environments, such as severe neutron irradiation damage at high temperatures. It has been known for decades that high dose radiation can introduce significant void swelling accompanied by precipitation in austenitic stainless steel (SS). Here we report, however, that through nanoengineering, ultra-fine grained (UFG) 304L SS with an average grain size of ~100 nm, can withstand Fe ion irradiation at 500°C to 80 displacements-per-atom (dpa) with moderate grain coarsening. Compared to coarse grained (CG) counterparts, swelling resistance of UFG SS is improved by nearly an order of magnitude and swelling rate is reduced by a factor of 5. M₂₃C₆ precipitates, abundant in irradiated CG SS, are largely absent in UFG SS. This study provides a nanoengineering approach to design and discover radiation tolerant metallic materials for applications in extreme radiation environments.

36 MATERIALS SCIENCE↗

Radiative emission enhancement using nano-antennas made of hyperbolic metamaterial resonators

A hyperbolic metamaterial (HM) resonator is analyzed as a nano-antenna for enhancing the radiative emission of quantum emitters in its vicinity. It has been shown that the spontaneous emission rate by an emitter near a hyperbolic metamaterial substrate is enhanced dramatically due to very large density of states. However, enhanced coupling to the free-space, which is central to applications such as solid-state lighting, has not been investigated significantly. Here, we numerically demonstrate approximately 100 times enhancement of the free-space radiative emission at 660 nm wavelength by utilizing a cylindrical HM resonator with a radius of 54 nm and a height of 80 nm on top of an opaque silver-cladded substrate. We also show how the free-space radiation enhancement factor depends on the dipole orientation and the location of the emitter near the subwavelength resonator. Furthermore, we calculate that an array of HM resonators with subwavelength spacings can maintain most of the enhancement effect of a single resonator.

36 MATERIALS SCIENCE↗

Common origin of warm dark matter and dark radiation

We consider a cosmological scenario where a relativistic particle and a stable massive particle are simultaneously produced from the decay of a late-decaying particle after Big-Bang Nucleosynthesis but before matter-radiation equality. The relativistic and massive particles behave as dark radiation and warm dark matter, respectively. Due to a common origin, the warmness and abundances are closely related. We refer to the models that lead to such a scenario as Common Origin of Warm and Relativistic Decay Products (COWaRD). We show that COWaRD predicts a correlation between the amount of dark radiation and suppression of the large scale structure, which can be tested in future precision cosmology observations. Furthermore, we demonstrate that COWaRD is realized, as an example, in a class of supersymmetric axion models and that future observations by the next generation Cosmic Microwave Background, Large Scale Structure, and 21-cm surveys can reveal the structure of the theory.

cosmology of theories beyond the SM↗

Modelling radiation damage to pixel sensors in the ATLAS detector

Silicon pixel detectors are at the core of the current and planned upgrade of the ATLAS experiment at the LHC. Given their close proximity to the interaction point, these detectors will be exposed to an unprecedented amount of radiation over their lifetime. The current pixel detector will receive damage from non-ionizing radiation in excess of 10 15 1 MeV n eq /cm 2 , while the pixel detector designed for the high-luminosity LHC must cope with an order of magnitude larger fluence. We present a digitization model incorporating effects of radiation damage to the pixel sensors. The model is described in detail and predictions for the charge collection efficiency and Lorentz angle are compared with collision data collected between 2015 and 2017 (≤ 10 15 1 MeV n eq /cm 2 ).

43 PARTICLE ACCELERATORS↗