Search NASA⌕ Search

SEARCH · Search NASA

Results for “RF”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Spectral functions and rf response of ultracold fermionic atoms

We present a calculation of the spectral functions and the associated rf response of ultracold fermionic atoms near a Feshbach resonance. The single-particle spectra are peaked at energies that can be modeled by a modified BCS dispersion. However, even at very low temperatures their width is comparable to their energy except for a small region around the dispersion minimum. The structure of the excitation spectrum of the unitary gas at infinite scattering length agrees with recent momentum-resolved rf spectra near the critical temperature. A detailed comparison is made with momentum integrated, locally resolved rf spectra of the unitary gas at arbitrary temperatures and shows very good agreement between theory and experiment. The pair size defined from the width of these spectra is found to coincide with that obtained from the leading gradient corrections to the effective-field theory of the superfluid.

74 ATOMIC AND MOLECULAR PHYSICS↗

Short-Time Operator Product Expansion for rf Spectroscopy of a Strongly Interacting Fermi Gas

Universal relations that hold for any state provide powerful constraints on systems consisting of fermions with two spin states interacting with a large scattering length. In radio-frequency (rf) spectroscopy, the mean shift in the rf frequency and the large-frequency tail of the rf transition rate are proportional to the contact, which measures the density of pairs with small separations. We show that these universal relations can be derived and extended by using the short-time operator product expansion of quantum field theory. This is a general method for identifying aspects of many-body physics that are controlled by few-body physics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Theory of rf-Spectroscopy of Strongly Interacting Fermions

We show that strong pairing correlations in Fermi gases lead to the appearance of a gaplike structure in the rf spectrum, both in the balanced superfluid and in the normal phase above the Clogston-Chandrasekhar limit. The average rf shift of a unitary gas is proportional to the ratio of the Fermi velocity and the scattering length with the final state. In the strongly imbalanced case, the rf spectrum measures the binding energy of a minority atom to the Fermi sea of majority atoms. Our results provide a qualitative understanding of recent experiments by Schunck et al.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cryogenic test of a proof-of-principle superconducting rf-dipole deflecting and crabbing cavity

Recent applications in need of compact low-frequency deflecting and crabbing cavities have initiated the design and development of new superconducting structures operating at high gradients with low losses. Previously, TM{sub 110}-type deflecting and crabbing cavities had been developed and have also been in operation successfully. However these geometries are not favorable designs for low operating frequencies. The superconducting rf-dipole cavity is the first compact deflecting and crabbing geometry that has demonstrated high gradients and high shunt impedance. Since the fundamental operating mode is the lowest mode and is widely separated from the nearest higher order mode, the rf-dipole design is an attractive geometry for effective damping of the higher order modes in high current applications. A 400 MHz rf-dipole cavity has been designed, fabricated, and tested as a proof-of-principle cavity. The cavity achieved high operating gradients, and the multipacting levels were easily processed and did not reoccur.

43 PARTICLE ACCELERATORS↗

Machining and brazing of accelerating RF cavity

BARC has developed 2856 MHz accelerating cavities for 6 MeV, 9 MeV and 10 MeV RF Linac. New vendors are developed for mass production of accelerating cavity for future projects. New vendors are developing for diamond turning machining, cleaning and brazing processes. Fabrication involved material testing, CNC diamond turning of cavity, cavity cleaning and brazing. Before and after brazing resonance frequency (RF) of cavity was checked with vector network analyser (VNA). A power feed test setup is also fabricated to test power feed cavity before brazing. This test setup will be used to find out assembly performance of power feed cavity and its coupler. This paper discusses about nano machining, cleaning and brazing processes of RF cavities. (author)

43 PARTICLE ACCELERATORS↗

Multi-beam RF Accelerators for Ion Implantation

We report on the development of a radio frequency (RF) linear accelerator (linac) for multiple-ion beams that is made from stacks of low cost wafers. The accelerator lattice is comprised of RF-acceleration gaps and electrostatic quadrupole focusing elements that are fabricated on 4' wafers made from printed circuit board or silicon. We demonstrate ion acceleration with an effective gradient of about 0.5MVm-1 with an array of 3 × 3 beams. The total ion beam energies achieved to date are in the 10 keV range with total ion currents in tests with noble gases of ~0.1mA. We discuss scaling of the ion energy (by adding acceleration modules) and ion currents (with more beams) for applications of this multi-beam RF linac technology to ion implantation and surface modification of materials.

Seidl, Peter A.↗

Results of the SLAC LCLS Gun High-Power RF Tests

The beam quality and operational requirements for the Linac Coherent Light Source (LCLS) currently being constructed at SLAC are exceptional, requiring the design of a new RF photocathode gun for the electron source. Based on operational experience at SLAC's GTF and SDL and ATF at BNL as well as other laboratories, the 1.6cell s-band (2856MHz) gun was chosen to be the best electron source for the LCLS, however a significant redesign was necessary to achieve the challenging parameters. Detailed 3-D analysis and design was used to produce near-perfect rotationally symmetric rf fields to achieve the emittance requirement. In addition, the thermo-mechanical design allows the gun to operate at 120Hz and a 140MV/m cathode field, or to an average power dissipation of 4kW. Both average and pulsed heating issues are addressed in the LCLS gun design. The first LCLS gun is now fabricated and has been operated with high-power RF. The results of these high-power tests are presented and discussed.

43 PARTICLE ACCELERATORS↗

Superconducting Materials Testing with a High-Q Copper RF Cavity

Superconducting RF is of increasing importance in particle accelerators. We have developed a resonant cavity with high quality factor and an interchangeable wall for testing of superconducting materials. A compact TE01 mode launcher attached to the coupling iris selectively excites the azimuthally symmetric cavity mode, which allows a gap at the detachable wall and is free of surface electric fields that could cause field emission, multipactor, and RF breakdown. The shape of the cavity is tailored to focus magnetic field on the test sample. We describe cryogenic experiments conducted with this cavity. An initial experiment with copper benchmarked our apparatus. This was followed by tests with Nb and MgB2. In addition to characterizing the onset of superconductivity with temperature, our cavity can be resonated with a high power klystron to determine the surface magnetic field level sustainable by the material in the superconducting state. A feedback code is used to make the low level RF drive track the resonant frequency.

43 PARTICLE ACCELERATORS↗

Application of extremum seeking for time-varying systems to resonance control of RF cavities

A recently developed form of extremum seeking for time-varying systems is implemented in hardware for the resonance control of radio-frequency cavities without phase measurements. Normal conducting RF cavity resonance control is performed via a slug tuner, while superconducting TESLA-type cavity resonance control is performed via piezo actuators. The controller maintains resonance by minimizing reflected power by utilizing model-independent adaptive feedback. Unlike standard phase-measurement-based resonance control, the presented approach is not sensitive to arbitrary phase shifts of the RF signals due to temperature-dependent cable length or phasemeasurement hardware changes. The phase independence of this method removes common slowly varying drifts and required periodic recalibration of phase-based methods. A general overview of the adaptive controller is presented along with the proof of principle experimental results at room temperature. Lastly, this method allows us to both maintain a cavity at a desired resonance frequency and also to dynamically modify its resonance frequency to track the unknown time-varying frequency of an RF source, thereby maintaining maximal cavity field strength, based only on power-level measurements.

47 OTHER INSTRUMENTATION↗

Influence of RF excitation during pulsed laser deposition in oxygen atmosphere on the structural properties and luminescence of nanocrystalline ZnO:Al thin films

Thin ZnO:Al layers were deposited by pulsed laser deposition in vacuum and in oxygen atmosphere at gas pressures between 10 and 70 Pa and by applying radio-frequency (RF) plasma. Grazing incidence small angle x-ray scattering and grazing incidence x-ray diffraction (GIXRD) data showed that an increase in the oxygen pressure leads to an increase in the roughness, a decrease in the sample density, and changes in the size distribution of nanovoids. The nanocrystal sizes estimated from GIXRD were around 20 nm, while the sizes of the nanovoids increased from 1 to 2 nm with the oxygen pressure. The RF plasma mainly influenced the nanostructural properties and point defects dynamics. The photoluminescence consisted of three contributions, ultraviolet (UV), blue emission due to Zn vacancies, and red emission, which are related to an excess of oxygen. The RF excitation lowered the defect level related to blue emission and narrowed the UV luminescence peak, which indicates an improvement of the structural ordering. The observed influence of the deposition conditions on the film properties is discussed as a consequence of two main effects: the variation of the energy transfer from the laser plume to the growing film and changes in the growth chemistry.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

New RF Control System for the 12 GeV Energy Upgrade of the CEBAF Accelerator at Jefferson Lab

The CEBAF Accelerator at Jefferson Lab presently consists of 50 MeV injector, two anti-parallel superconducting linacs and two arcs for transporting beam between the linacs. By the mid-1990s, the accelerator was providing electrons up to 5.75 GeV. The 12 GeV Upgrade is a major accelerator project aimed at doubling the energy by adding 10 (five per linac) new high gradient cryomodules, each providing 100 MV of field. The new cryomodule will consist of eight 7-cell superconducting cavities operating at an average accelerating gradient of 19.5 MV/m and with an external Q=3.2 x 10^7. The high gradient, very high quality factor and large Lorentz detuning coefficient (KL up to 4) pose significant challenges beyond what the present analog low level RF (LLRF) control systems can handle reliably; therefore, a new digital LLRF control system has been developed. The main highlights of the new RF Control system include: a RF front-end with low temperature drift and good linearity, a large FPGA

43 PARTICLE ACCELERATORS↗

SU-E-J-71: Feasibility Study On MRI-Based BANG3 Gel Dosimetry Using Dual-Source Parallel RF Transmission System

Purpose: In this work, we present the feasibility of use of the parallel RF transmission with multiple RF source (MultiTransmit) imaging in MRI-based polymer gel dosimetry. Methods: The commercially available BANG3 gel was used for gel dosimetry. Spin-spin relaxation rate R2 was used to quantify the absorbed dose. The image quality (signal-to-noise ratio, SNR; image uniformity) and B1 field inhomogeneity between conventional single-source and MultiTransmit MR imaging were compared. Finally, the estimated R2 uncertainty σ(R2) and dosimetric performance (i.e., dose resolution) between conventional single-source and MultiTransmit MR imaging were compared. Results: Image quality and B1 field homogeneity within each calibration vial and large phantom was statistically better in MultiTransmit imaging than in conventional single-source RF transmission imaging (P < 0.005 for all calibration vials). In particular, σ(R2) (defined as the standard uncertainty of R2) was lower on the MultiTransmit images than on the conventional single-source images. Furthermore, the MultiTransmit measurement gives a lower than that obtained using the conventional single-source method. Conclusion: The improved image quality and B1 homogeneity resulted in reduced dose uncertainty (i.e., σ(R2) and dose resolution) in MRI-based polymer gel dosimetry, suggesting that MultiTransmit MR imaging has potential benefits for use in clinical 3D gel dosimetry without the need for the complicated B1 field correction method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dimorphism of RF{sub 3} (R = La–Nd) crystals based on the data of X-ray diffraction studies

The ratio of two forms of tysonite in nominally pure single crystals of RF{sub 3} (R = La–Nd) obtained from melts under identical conditions (the as-grown state) is studied for the first time by X-ray diffraction. Crystals of RF{sub 3} with R = La–Nd belong to the β-LaF{sub 3} structural type (space group P3̄c1, Z = 6) and form twins. Samples 0.2–0.4 in diameter contain inclusions of the high-temperature a form (space group P6{sub 3}/mmc, Z = 2). It is shown that twinning and dimorphism of the RF{sub 3} crystals (R = La–Nd) have a common structural basis.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of an External Magnetic Field on the Absorption Efficiency of the RF Power in a Spatially Bounded Inductive Plasma Source

The measured dependences of the equivalent plasma resistance on the external magnetic field (0–50 G) in a 46-cm-diameter RF inductive plasma source operating at frequencies of 2, 4, and 13.56 MHz and a power of 100–500 W are presented. The experiments were carried out in argon at pressures of 0.1–30 mTorr. The presence of the external magnetic field leads to the appearance of resonance domains of efficient RF power absorption corresponding to the conditions of resonance excitation of helicons coupled with Trivelpiece–Gould modes. It is shown that RF power absorption at frequencies of 2 MHz can be optimized by applying an external magnetic field corresponding to the domains of resonance absorption. The effect is enhanced with increasing operating frequency.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

USPAS Digital Low-Level RF firmware and software suite (uspas_llrf) v1.0

The USPAS Digital Low-Level RF firmware and software suite was originally developed for the USPAS 2023 LLRF course, for demonstrating the close loop RF control on the BerkeleyLab Marble FPGA carrier and Zest digitizer platform in controlling the RF field for various accelerators. The suite features Register-transfer level (RTL) designs for the board-support layer, digital signal processing and verification test benches, system-on-chip architecture, and Experimental Physics and Industrial Control System (EPICS) support, utilizing a open-source tool chain.

Du, Qiang↗

Perceived colour fidelity under LEDs with similar Rf but different Ra

Substantial efforts have been made to develop new colour fidelity measures that are better correlated to perceived colour fidelity. Such measures minimize the possibility of increasing rated colour fidelity through spectral optimization without improving perceived colour fidelity. This paper reports a psychophysical experiment that was carefully designed to investigate how light sources with different spectral features affected perceived colour fidelity, and whether the effect can be reflected by the two existing colour fidelity measures (CIE Ra and Illuminating Engineering Society (IES) Rf). Fourteen observers evaluated the colour differences of eight physical colour samples under three pairs of light sources, which had similar IES Rf but different Ra values. IES Rf was found to perform better than CIE Ra.

Huang, Hsin-Pou↗

A COMPACT BEAM SPREADER USING RF DEFLECTING CAVITIES FOR THE LCLS-II

The LCLS-II project currently under development is designed to accelerate electron bunches up to 4 GeV and transport them to one of two FEL undulators located more than 2 km downstream of the end of the LCLS-II linac. The upgrade requires a spreader system to separate the baseline electron bunches and transport them to two undulator lines or a local dump. Fast bipolar kickers (FK) or transverse electric rf deflectors (RFD) are considered as fast-switching devices (FSD). In the RFD approach described here three design options operating at 325 MHz are studied including a superconducting rf-dipole cavity, a normal conducting rf-dipole cavity, and a normal conducting 4-rod cavity. Optional compact splitting schemes involving a combination of vertical and horizontal initial deflections are addressed.

De Silva, S. U.↗

DESIGN AND PROTOTYPING OF A 400 MHz RF-DIPOLE CRABBING CAVITY FOR THE LHC HIGH-LUMINOSITY UPGRADE

LHC High Luminosity Upgrade is in need of two crabbing systems that deflects the beam in both horizontal and vertical planes. The 400 MHz rf-dipole crabbing cavity system is capable of crabbing the proton beam in both planes. At present we are focusing our efforts on a complete crabbing system in the horizontal plane. Prior to LHC installation the crabbing system will be installed for beam test at SPS. The crabbing system consists of two rf-dipole cavities in the cryomodule. This paper discusses the electromagnetic design and mechanical properties of the rf-dipole crabbing system for SPS beam test.

De Silva, Payagalage Subashini↗