Design and calibration of a rocket-borne electron spectrometer for investigation of particle ionization in the nighttime midlatitude E region

An explanation was developed for the formation, near midnight at midlatitudes, of a broad electron density layer extending approximately from 120 to 180 km and usually referred to as the intermediate E layer. The responsible mechanism is believed to be the converging vertical ion drifts resulting from winds of the solar semidiurnal tide. Numerical solutions of the continuity equation appropriate to the intermediate layer is described for particular models of ion drift, diffusion coefficents, and ionization production. Analysis of rocket observations of the layer show that the ionization rate is highly correlated with the planetary geomagnetic index, K sub p. Particle flux measurements support the idea that energetic electrons are the principal source of this ionization. A semiconductor spectrometer experiment for investigation of the particle flux, spectrum, and angular properties was designed and successfully flown on a Nike Apache rocket. A detailed description of the theory, design, and calibration of the experiment and some preliminary results presented.

Voss, H. D.↗

Some anomalies between wind tunnel and flight transition results

A review of environmental disturbance influence and boundary layer transition measurements on a large collection of reference sharp cone tests in wind tunnels and of recent transonic-supersonic cone flight results have previously demonstrated the dominance of free-stream disturbance level on the transition process from the beginning to end. Variation of the ratio of transition Reynolds number at onset-to-end with Mach number has been shown to be consistently different between flight and wind tunnels. Previous correlations of the end of transition with disturbance level give good results for flight and large number of tunnels, however, anomalies occur for similar correlation based on transition onset. Present cone results with a tunnel sonic throat reduced the disturbance level by an order of magnitude with transition values comparable to flight.

Harvey, W. D.↗

Relating a Spectral Index from MODIS and Tower-based Measurements to Ecosystem Light Use Efficiency for a Fluxnet-Canada Coniferous Forest

As part of the North American Carbon Program effort to quantify the terrestrial carbon budget of North America, we have been examining the possibility of retrieving ecosystem light use efficiency (LUE, the carbon sequestered per unit photosynthetically active radiation) directly from satellite observations. Our novel approach has been to compare LUE derived from tower fluxes with LUE estimated using spectral indices computed from MODIS satellite observations over forests in the Fluxnet-Canada Research Network, using the MODIS narrow ocean bands acquired over land. We matched carbon flux data collected around the time of the MODIS mid-day overpass for over one hundred relatively clear days in five years (2001-2006) from a mature Douglas fir forest in British Columbia. We also examined hyperspectral reflectance data collected diurnally from the tower in conjunction with the eddy correlation fluxes and meteorological measurements made throughout the 2006 growing season at this site. The tower-based flux data provided an opportunity to examine diurnal and seasonal LUE processes and their relationship to spectral indices at the scale of the forest stand. We evaluated LUE in conjunction with the Photochemical Reflectance Index (PRI), a normalized difference spectral index that uses 531 nm and a reference band to capture responses to high light induced stress afforded by the xanthophyll cycle. Canopy structure information, retrieved from airborne laser scanning radar (LiDAR) observations, was used to partition the forest canopy into sunlit and shaded fractions throughout the day, on numerous days during 2006. At each observation period throughout a day, the PRI was examined for the sunlit, shaded, and intermediate canopy segments defined by their instantaneous position relative to the solar principal plane (SPP). The sunlit sector was associated with the illumination "hotspot" (the reflectance backscatter maximum), the shaded sector with the "cold or dark spot" (the reflectance forward scatter minimum), while the intermediate, mixed sunlit/shade sector was located in the cross-plane to the SPP. The PRI indices clearly captured the differences in leaf groups, with sunlit foliage exhibiting the lowest values on sunny days throughout the 2006 season. When tower-based canopy-level LUE was recalculated to estimate foliage-based values (LUE(sub foilage) for the three foliage groups under their incident light environments, a strong linear relationship for PRI:LUE(sub foilage) was demonstrated (0.6 less than or equal to r(sup 2) less than or equal to 0.8, n=822, P<0.0001). The MODIS data represent relatively large areas when acquired at nadir (approx.1 sq km) or at variable off-nadir view angles (greater than or equal to 1 sq km) looking forward or aft. Nevertheless, a similar relationship between MODIS PRI and tower-based LUE was obtained from satellite observations (r(sup 2) = 0.76, n=105, P= 0.026) when the azimuth offsets from the SPP for off-nadir observations were considered. At this relatively high latitude of 50 degrees, the MODIS directional observations were offset from the SPP by approximately 50 degrees, but still represented backscatter or forward scatter sectors of the bidirectional reflectance distribution function (BRDF). The backscatter observations sampled the sunlit forest and provided lower PRI values, in general, than the forward scatter observations from the shaded forest. Since the hotspot and darkspot were not typically directly observed, the dynamic range for MODIS PRI was less than that observed in the SPP at the canopy level; therefore, MODIS PRI values were more similar to those observed in sifu in the BRDF cross-plane. While not ideal in terms of spatial resolution or optimal viewing configuration, the MODIS observations nevertheless provide a means to monitor forest under stress using narrow spectral band indices and off-nadir observations. This research has stimulated several spin-off studies for remote sensinf LUE, and demonstrates the importance of the connection between ecosystem structure and physiological function.

Middleton, Elizabeth M.↗

Planning of an Experiment for VLBI Tracking of GNSS Satellites

As a preparation for future possible orbit determination of global navigation satellite system (GNSS) satellites by VLBI observations an initial three-station experiment was planned and performed in January 2009. The goal was to get first experience and to verify the feasibility of using the method for accurate satellite tracking. GNSS orbits related to a satellite constellation can be expressed in the Terrestrial Reference Frame. A comparison with orbit results that might be obtained by VLBI can give valuable information on how the GNSS reference frame and the VLBI reference frame are linked. We present GNSS transmitter specifications and experimental results of the observations of some GLONASS satellites together with evaluations for the expected signal strengths at telescopes. The satellite flux densities detected on the Earth s surface are very high. The narrow bandwidth of the GNSS signal partly compensates for potential problems at the receiving stations, and signal attenuation is necessary. Attempts to correlate recorded data have been performed with different software.

Tornatore, Vincenza↗

Fluid Shifts

NASA is focusing on long-duration missions on the International Space Station (ISS) and future exploration-class missions beyond low-Earth orbit. Visual acuity changes observed after short-duration missions were largely transient, but more than 50% of ISS astronauts experienced more profound, chronic changes with objective structural and functional findings such as papilledema and choroidal folds. Globe flattening, optic nerve sheath dilation, and optic nerve tortuosity also are apparent. This pattern is referred to as the visual impairment and intracranial pressure (VIIP) syndrome. VIIP signs and symptoms, as well as postflight lumbar puncture data, suggest that elevated intracranial pressure (ICP) may be associated with the spaceflight-induced cephalad fluid shifts, but this hypothesis has not been tested. The purpose of this study is to characterize fluid distribution and compartmentalization associated with long-duration spaceflight, and to correlate these findings with vision changes and other elements of the VIIP syndrome. We also seek to determine whether the magnitude of fluid shifts during spaceflight, as well as the VIIP-related effects of those shifts, is predicted by the crewmember's preflight conditions and responses to acute hemodynamic manipulations (such as head-down tilt). Lastly, we will evaluate the patterns of fluid distribution in ISS astronauts during acute reversal of fluid shifts through application of lower body negative pressure (LBNP) interventions to characterize and explain general and individual responses. METHODS: We will examine a variety of physiologic variables in 10 long-duration ISS crewmembers using the test conditions and timeline presented in the Figure below. Measures include: (1) fluid compartmentalization (total body water by D2O, extracellular fluid by NaBr, intracellular fluid by calculation, plasma volume by CO rebreathe, interstitial fluid by calculation); (2) forehead/eyelids, tibia, calcaneus tissue thickness (by ultrasound); (3) vascular dimensions by ultrasound (jugular veins, cerebral and carotid arteries, vertebral arteries and veins, portal vein); (4) vascular dynamics by MRI (head/neck blood flow, cerebrospinal fluid pulsatility); (5) ocular measures (optical coherence tomography, intraocular pressure, 2-dimensional ultrasound including optic nerve sheath diameter, globe flattening, and retina-choroid thickness, Doppler ultrasound of ophthalmic and retinal arteries, and veins); (6) cardiac variables by ultrasound (inferior vena cava, tricuspid flow and tissue Doppler, pulmonic valve, stroke volume, right heart dimensions and function, four-chamber views); and (7) ICP measures (tympanic membrane displacement, distortion-product otoacoustic emissions, and ICP calculated by MRI). On the ground, acute head-down tilt will induce cephalad fluid shifts, whereas LBNP will oppose these shifts. Controlled Mueller maneuvers will manipulate cardiovascular variables. Through interventions applied before, during, and after flight, we intend to fully evaluate the relationship between fluid shifts and the VIIP syndrome.

Stenger, M.↗

An accurate nonlinear finite element analysis and test correlation of a stiffened composite wing panel

State-of-the-art nonlinear finite element analysis techniques are evaluated by applying them to a realistic aircraft structural component. A wing panel from the V-22 tiltrotor aircraft is chosen because it is a typical modern aircraft structural component for which there is experimental data for comparison of results. From blueprints and drawings, a very detailed finite element model containing 2284 9-node Assumed Natural-Coordinate Strain elements was generated. A novel solution strategy which accounts for geometric nonlinearity through the use of corotating element reference frames and nonlinear strain-displacement relations is used to analyze this detailed model. Results from linear analyses using the same finite element model are presented in order to illustrate the advantages and costs of the nonlinear analysis as compared with the more traditional linear analysis.

Davis, D. D., Jr.↗

Simultaneous radio and optical observations of UV Ceti-type flare stars

The UV Ceti-type stars, YZ Canis Minoris, AD Leonis, and Wolf 424 AB, were monitored for 57.8 hours from January 15 to February 22, 1974, using the 1000-foot (305-m) radio telescope at Arecibo, Puerto Rico, and the 91-cm or 76-cm reflector at McDonald Observatory. Radio observations were made at frequencies of 430, 318, and 196 MHz, and optical monitoring was done in the Johnson U or B band, the Stromgren u band, or white light. During the period of simultaneous observations, 62 optical flares were detected. A total of 13 RF flares were independently identified, of which 10 reached maximum flux within 10 min of the peak time of an optical flare. Using times of optical-flare events as reference data, an additional 15 cases of radio enhancements associated with optical flares are identified. The most probable delay interval between the optical-flare maximum and 318-MHz radio peak was found to be 0 to 5 min, with the optical flare occurring first. Aside from this statistical delay of peak occurrence and a general tendency for radio and optical flares to be associated, no systematic correlations of optical and radio amplitudes or morphology were found. The possible consequences of the radio emission's being due to a coherent process are discussed.

Spangler, S. R.↗

Multiple Reservoirs of Volatiles in the Moon Revealed by the Isotopic Composition of Chlorine in Lunar Basalts

The isotopes of chlorine (37Cl and 35Cl) are highly fractionated in lunar samples compared to most other Solar System materials. Recently, the chlorine isotope signatures of lunar rocks have been attributed to large-scale degassing processes that occurred during the existence of a magma ocean. In this study we investigated how well a suite of lunar basalts, most of which have not previously been analyzed, conform to previous models. The Cl isotope compositions (δ37Cl (‰) = [(37Cl/35Clsample/37Cl/35ClSMOC) − 1] × 1000, where SMOC refers to standard mean ocean chloride) recorded range from ∼+7 to +14‰ (Apollo 15), +10 to +19‰ (Apollo 12), +9 to +15‰ (70017), +4 to +8‰ (MIL 05035), and +15 to +22‰ (Kalahari 009). The Cl isotopic data from the present study support the mixing trends previously reported by Boyce et al. (2015) and Barnes et al. (2016), as the Cl isotopic composition of apatites are positively correlated with bulk-rock incompatible trace element abundances in the low-Ti basalts, inclusive of low-Ti and KREEP basalts. This trend has been interpreted as evidence that incompatible trace elements, including Cl, were concentrated in the urKREEP residual liquid of the lunar magma ocean, rather than the mantle cumulates, and that urKREEP Cl had a highly fractionated isotopic composition. The source regions for the basalts were thus created by variable mixing between the mantle (Cl-poor and relatively unfractionated) and urKREEP. The high-Ti basalts show much more variability in measured Cl isotope ratios and scatter around the trend formed by the low-Ti basalts. Most of the data for lunar meteorites also fits the mixing of volatiles in their sources, but Kalahari 009, which is highly depleted in incompatible trace elements, contains apatites with heavily fractionated Cl isotopic compositions. Given that Kalahari 009 is one of the oldest lunar basalts and ought to have been derived from very early-formed mantle cumulates, a heavy Cl isotopic signature is likely not related to its mantle source, but more likely to magmatic or secondary alteration processes, perhaps via impact-driven vapor metasomatism of the lunar crust.

Mccubbin, Francis M.↗

Inferred Sea Level Prediction in the NASA GMAO Seasonal Forecasting System

Reliable predictions of sea level anomalies on seasonal timescales with lead times of 1 to 9 months may have relevance to stakeholders – for example, in the advance deployment of resources for coastal flood mitigation. Routine prediction and analysis may also highlight physical processes associated with sea level change and modeling capabilities on seasonal and other timescales. These forecasts may represent interannual changes in the seasonal slope of the ocean surface, teleconnection effects such as the El Niño/Southern Oscillation phenomenon, and variations in seasonal hydrology including precipitation and coastal runoff. Coupled atmosphere/ocean models are routinely used in the seasonal prediction of temperature anomalies, precipitation anomalies, sea ice cover, and climate indices such as the Niño3.4 predictions under the North American Multi-Model Ensemble (NMME) protocol. Within the limits of their configuration, these complex Earth-system models have a potential for depicting regional changes in oceanic column properties, including the sea surface height. Seasonal prediction models generally have no representation of long-term mass contributions from melting land ice, or changes in vertical land motion; their output may be more specifically characterized as predictions of the ocean dynamic sea level. In practice however, the sea surface height prognostic variable is substantially compromised by the forecast model response to initial conditions. Imbalances between the initial, observed hydrologic cycle and the forecast model state produce abrupt adjustments in the model sea surface height. As a result, most seasonal prediction systems employ a constraint on the globally-averaged sea surface height that is applied at each time step. This essentially renders the prognostic sea surface height variable as unserviceable. Several approaches have previously been used to retrieve sea level information from seasonal forecasts beyond the use of the sea surface height variable. Here, we extend a method of relating other prognostic values, including ocean circulation and climate indices, to observed sea level variations. We use the merged altimetry record of the NASA MEaSUREs Gridded Sea Surface Height Anomalies data set and monthly revised local reference gauge observations from the National Oceanography Centre Permanent Service for Mean Sea Level (PSMSL) to evaluate derived prognostic variables from the NASA Global Modeling and Assimilation Office subseasonal-to-seasonal system version 2.1 (GMAO S2S v2.1). We focus on results for the midlatitudes with particular emphasis on US gauge locations. As shown in previous studies, prognostic ENSO-related indices in boreal winter are well correlated with gauge observations for the US west coast, but also for other locations in the southeastern US. Other forecast climate indices such as the North Atlantic Oscillation have relations to sea level that are limited both seasonally and spatially. As expected, surface atmospheric pressure (e.g., inverse barometer effect) is found to be particularly well correlated with observed sea level. We provide a characterization of forecast skill for seasonal sea level with this method.

Richard I Cullather↗

Concept for the subresolution measurement of earthquake strain fields using SPOT panchromatic imagery

The use of satellite-derived imagery for measuring subresolution horizontal terrain displacments associated with present-day earthquakes is discussed with reference to data from the French SPOT satellite whose sensor array provides 10-m panchromatic imagery. The measured terrain displacements can be up to several meters, but usually no more than 6-8 m even for major earthquakes. The general approach is to spatially match the after image to the before image at each point on a half-kilometer grid by iteratively interpolating one and testing its correlation with the other. The discussion covers the basic algorithm, results of initial tests, error types and limitations, and future work.

Crippen, Robert E.↗

Fluid Shifts

NASA is focusing on long-duration missions on the International Space Station (ISS) and future exploration-class missions beyond low Earth orbit. Visual acuity changes observed after short-duration missions were largely transient, but more than 30% of ISS astronauts experience more profound, chronic changes with objective structural and functional findings such as papilledema and choroidal folds. Globe flattening, optic nerve sheath dilation, and optic nerve tortuosity also are apparent. This pattern is referred to as the visual impairment and intracranial pressure (VIIP) syndrome. VIIP signs and symptoms, as well as postflight lumbar puncture data, suggest that elevated intracranial pressure (ICP) may be associated with the space flight-induced cephalad fluid shifts, but this hypothesis has not been tested. The purpose of this study is to characterize fluid distribution and compartmentalization associated with long-duration space flight, and to correlate these findings with vision changes and other elements of the VIIP syndrome. We also seek to determine whether the magnitude of fluid shifts during space flight, as well as the VIIP-related effects of those shifts, is predicted by the crewmember's pre-flight condition and responses to acute hemodynamic manipulations (such as head-down tilt). Lastly, we will evaluate the patterns of fluid distribution in ISS astronauts during acute reversal of fluid shifts through application of lower body negative pressure (LBNP) interventions to characterize and explain general and individual responses. We will examine a variety of physiologic variables in 10 long-duration ISS crewmembers using the test conditions and timeline presented in the Figure below. Measures include: (1) fluid compartmentalization (total body water by D2O, extracellular fluid by NaBr, intracellular fluid by calculation, plasma volume by CO rebreathe, interstitial fluid by calculation); (2) forehead/eyelids, tibia, calcaneus tissue thickness (by ultrasound); (3) vascular dimensions by ultrasound (jugular veins, cerebral and carotid arteries, vertebral arteries and veins, portal vein); (4) vascular dynamics by MRI (head/neck blood flow, cerebrospinal fluid pulsatility); (5) ocular measures (optical coherence tomography, intraocular pressure, 2-dimensional ultrasound including optic nerve sheath diameter, globe flattening, and retina-choroid thickness, Doppler ultrasound of ophthalmic and retinal arteries, and veins); (6) cardiac variables by ultrasound (inferior vena cava, tricuspid flow and tissue Doppler, pulmonic valve, stroke volume, right heart dimensions and function, four-chamber views); and (7) ICP measures (tympanic membrane displacement, distortion-product otoacoustic emissions, and ICP calculated by MRI). On the ground, acute head-down tilt will induce cephalad fluid shifts, whereas LBNP will oppose these shifts. Controlled Mueller maneuvers will manipulate cardiovascular variables. Through interventions applied before, during, and after flight, we intend to fully evaluate the relationship between fluid shifts and the VIIP syndrome. This study has been selected for flight implementation and is one of the candidate investigations being considered for the one year mission.

Stenger, Michael↗

Global Relationships Among Traditional Reflectance Vegetation Indices (NDVI and NDII), Evapotranspiration (ET), and Soil Moisture Variability on Weekly Time Scales

Monitoring the effects of water availability on vegetation globally using satellites is important for applications such as drought early warning, precision agriculture, and food security as well as for more broadly understanding relationships between water and carbon cycles. In this global study, we examine how quickly several satellite-based indicators, assumed to have relationships with water availability, respond, on timescales of days to weeks, in comparison with variations in root-zone soil moisture (RZM) that extends to about 1 m depth. The satellite indicators considered are the normalized difference vegetation and infrared indices (NDVI and NDII, respectively) derived from reflectances obtained with moderately wide (20–40 nm) spectral bands in the visible and near-infrared (NIR) and evapotranspiration (ET) estimated from thermal infrared observations and normalized by a reference ET. NDVI is primarily sensitive to chlorophyll contributions and vegetation structure while NDII may contain additional information on water content in leaves and canopy. ET includes both the loss of root zone soil water through transpiration (modulated by stomatal conductance) as well as evaporation from bare soil. We find that variations of these satellite-based drought indicators on time scales of days to weeks have significant correlations with those of RZM in the same water-limited geographical locations that are dominated by grasslands, shrublands, and savannas whose root systems are generally contained within the 1 m RZM layer. Normalized ET interannual variations show generally a faster response to water deficits and enhancements as compared with those of NDVI and NDII, particularly in sparsely vegetated regions.

Joanna Joiner↗

Detailed analysis and test correlation of a stiffened composite wing panel

Nonlinear finite element analysis techniques are evaluated by applying them to a realistic aircraft structural component. A wing panel from the V-22 tiltrotor aircraft is chosen because it is a typical modern aircraft structural component for which there is experimental data for comparison of results. From blueprints and drawings supplied by the Bell Helicopter Textron Corporation, a very detailed finite element model containing 2284 9-node Assumed Natural-Coordinate Strain (ANS) elements was generated. A novel solution strategy which accounts for geometric nonlinearity through the use of corotating element reference frames and nonlinear strain displacements relations is used to analyze this detailed model. Results from linear analyses using the same finite element model are presented in order to illustrate the advantages and costs of the nonlinear analysis as compared with the more traditional linear analysis. Strain predictions from both the linear and nonlinear stress analyses are shown to compare well with experimental data up through the Design Ultimate Load (DUL) of the panel. However, due to the extreme nonlinear response of the panel, the linear analysis was not accurate at loads above the DUL. The nonlinear analysis more accurately predicted the strain at high values of applied load, and even predicted complicated nonlinear response characteristics, such as load reversals, at the observed failure load of the test panel. In order to understand the failure mechanism of the panel, buckling and first ply failure analyses were performed. The buckling load was 17 percent above the observed failure load while first ply failure analyses indicated significant material damage at and below the observed failure load.

Davis, D. Dale, Jr.↗

Direct evidence for stellar wind X-ray absorption in O stars

The observed X-ray spectral distributions from O stars are highly dependent upon the absorbing media traversed. These media include the cold ISM and the 'local' highly ionized dense surrounding medium commonly referred to as the stellar wind or envelope. Since this local absorption may exceed the ISM absorption, the usual practice of neglecting the local component may lead to underestimates of the intrinsic X-ray fluxes by several orders of magnitude. Previously, the neglect of the local component was justified, since no direct observational evidence supporting local absorption existed. Here evidence is presented for local absorption by showing a correlation between the observed X-ray hardness ratios (an indicator of absorption) and the 6 cm radio data (a measure of the stellar wind column density). It is proposed that this relation may be the first 'positive' confirmation of the existence of the local absorption component.

Waldron, Wayne L.↗

How to Enter, Fly In, and Exit the A-Train Constellation

The collaborative science obtained from the satellites in the A-Train is an unparalleled success. The constellation framework that has evolved is well-formulated and documented by its international members. Communication between teams is enhanced by a web-based Constellation Coordination System. Safety and correlated observations are ensured by defining independent control boxes with buffers in between. Each mission stays within its control box by regular drag makeup maneuvers. Annual inclination adjustments are coordinated by all missions to maintain their absolute and relative Mean Local Time of Ascending Node (MLTAN). Since the satellites are in different orbit planes their separation involves a three-dimensional triad made up of the along track separations, reference groundtracks and MLTAN's. For further safety, a Constellation Envelope has been defined to determine safe entry and exit orbits.

MLTAN↗

The dissociation energy of Cu2 - Do we want to perform multi-reference singles and doubles CIs on many-electron systems?

Reference is made to a study by Hay and Dunning (1976), who showed that, for most problems, it is not necessary to perform full FOCI (first order configuration interaction); instead, only that subset of configuration state functions (CSFs) that differ by only one or two spin orbitals from any of a list of reference configurations need be used. This is referred to as POLCI. Calculations of the D(e) of Cu2 using both SDCI (singles and doubles configuration interaction) and POLCI models are presented. It is found that the size-consistency problems associated with SDCI cause an error in D(e), whereas the POLCI results are in excellent agreement with experiment. It is proposed that the orbitals be classified as inactive and active and that the inactive-inactive correlation be eliminated to reduce the size-consistency error. In addition, it is recommended that SDCI treatments be applied with caution to systems having a large number of electrons.

Bauschlicher, C. W., Jr.↗

Atmospheric and spectroscopic research in the far infrared

The University of Oregon (UO) has been a major participant in the development of far infrared spectroscopic research of the stratosphere for the purpose of understanding the ozone layer processes. The UO has had a 15-year collaboration with the Italian group of B. Carli, and have participated in the 1978/79 Sub-millimeter Infrared Balloon Experiment (SIBEX), in the Balloon Intercomparison Campaign, (BIC), in the Infrared Balloon Experiment (IBEX), and in the recently concluded Far Infrared Experiment for UARS Correlative Measurements (FIREX). Both IBEX and FIREX programs were conducted in collaboration with NASA Langley, and were designed as validation flights in support of the Upper Atmosphere Research Satellite (UARS) Program. The technique of atmospheric far infrared spectroscopy offers two important advantages. First, many chemically important species can be measured simultaneously and co-spatially in the atmosphere. Second, far infrared atmospheric spectra can be obtained in thermal emission without reference to the sun's position, enabling full diurnal and global coverage. Recent improvements in instrumentation, field measurements, and molecular concentration retrieval techniques are now making the far infrared a mature measurement technology. This work to date has largely focused on balloon-based studies, but the future efforts will focus also on satellite-based experiments. A program of research in the following general areas was proposed: Laboratory Pressure broadening coefficient studies; specialized detector system assembly and testing; and consultation and assistance with instrument and field support. The proposal was approved and a three-year research grant titled 'Atmospheric and Spectroscopic Research in the Far Infrared' was awarded. A summary of technical accomplishments attained during the grant period are presented.

Park, Kwangjai↗

Noninvasive, near infrared spectroscopic-measured muscle pH and PO2 indicate tissue perfusion for cardiac surgical patients undergoing cardiopulmonary bypass

OBJECTIVE: To determine whether near infrared spectroscopic measurement of tissue pH and Po2 has sufficient accuracy to assess variation in tissue perfusion resulting from changes in blood pressure and metabolic demand during cardiopulmonary bypass. DESIGN: Prospective clinical study. SETTING: Academic medical center. SUBJECTS: Eighteen elective cardiac surgical patients. INTERVENTION: Cardiac surgery under cardiopulmonary bypass. MEASUREMENTS AND MAIN RESULTS: A near infrared spectroscopic fiber optic probe was placed over the hypothenar eminence. Reference Po2 and pH sensors were inserted in the abductor digiti minimi (V). Data were collected every 30 secs during surgery and for 6 hrs following cardiopulmonary bypass. Calibration equations developed from one third of the data were used with the remaining data to investigate sensitivity of the near infrared spectroscopic measurement to physiologic changes resulting from cardiopulmonary bypass. Near infrared spectroscopic and reference pH and Po2 measurements were compared for each subject using standard error of prediction. Near infrared spectroscopic pH and Po2 at baseline were compared with values during cardiopulmonary bypass just before rewarming commenced (hypotensive, hypothermic), after rewarming (hypotensive, normothermic) just before discontinuation of cardiopulmonary bypass, and at 6 hrs following cardiopulmonary bypass (normotensive, normothermic) using mixed-model analysis of variance. Near infrared spectroscopic pH and Po2 were well correlated with the invasive measurement of pH (R2 =.84) and Po2 (R 2 =.66) with an average standard error of prediction of 0.022 +/- 0.008 pH units and 6 +/- 3 mm Hg, respectively. The average difference between the invasive and near infrared spectroscopic measurement was near zero for both the pH and Po2 measurements. Near infrared spectroscopic Po2 significantly decreased 50% on initiation of cardiopulmonary bypass and remained depressed throughout the bypass and monitored intensive care period. Near infrared spectroscopic pH decreased significantly during cardiopulmonary bypass, decreased significantly during rewarming, and remained depressed 6 hrs after cardiopulmonary bypass. Diabetic patients responded differently than nondiabetic subjects to cardiopulmonary bypass, with lower muscle pH values (p =.02). CONCLUSIONS: Near infrared spectroscopic-measured muscle pH and Po2 are sensitive to changes in tissue perfusion during cardiopulmonary bypass.

Non-NASA Center↗