Search NASA⌕ Search

SEARCH · Search NASA

Results for “Relative Permeability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Dirac cone and double zero materials

Materials with zero permittivity and zero permeability (double zero) possess very interesting wave manipulation characteristics. Systems with Dirac cones in the band structure also possess amazing wave transport properties. These two classes of material are actually related to each other. We show that dielectric photonic crystals can be designed and fabricated which exhibit Dirac cones at k = 0 at a finite frequency. A subset of such materials behave as if they have zero permittivity and zero permeability at the Dirac point, as well as exhibiting properties intrinsic to a Dirac cone.

36 MATERIALS SCIENCE↗

Microfluidic Fabrication Techniques for High-Pressure Testing of Microscale Supercritical CO 2 Foam Transport in Fractured Unconventional Reservoirs

Pressure limitations of many microfluidic platforms have been a significant challenge in microfluidic experimental studies of fractured media. As a result, these platforms have not been fully exploited for direct observation of high-pressure transport in fractures. This work introduces microfluidic platforms that enable direct observation of multiphase flow in devices featuring surrogate permeable media and fractured systems. Such platforms provide a pathway to address important and timely questions such as those related to CO 2 capture, utilization and storage. This work provides a detailed description of the fabrication techniques and an experimental setup that may serve to analyze the behavior of supercritical CO 2 (scCO 2 ) foam, its structure and stability. Such studies provide important insights regarding enhanced oil recovery processes and the role of hydraulic fractures in resource recovery from unconventional reservoirs. This work presents a comparative study of microfluidic devices developed using two different techniques: photolithography/wet-etching/ thermal-bonding versus Selective Laser-induced Etching. Both techniques result in devices that are chemically and physically resistant and tolerant of high pressure and temperature conditions that correspond to subsurface systems of interest. Both techniques provide pathways to high-precision etched microchannels and capable lab-on-chip devices. Photolithography/wet-etching, however, enables fabrication of complex channel networks with complex geometries, which would be a challenging task for laser etching techniques. This work summarizes a step-by-step photolithography, wet-etching and glass thermal-bonding protocol and, presents representative observations of foam transport with relevance to oil recovery from unconventional tight and shale formations. In conclusion, this work describes the use of a high resolution monochromatic sensor to observe scCO 2 foam behavior where the entirety of the permeable medium is observed simultaneously while preserving the resolution needed to resolve features as small as 10 μm.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of plasma-magnetic photonic crystal with a tunable band gap

In this paper, electromagnetic wave propagation through the one-dimensional plasma-magnetic photonic crystal in the presence of external magnetic field has been analyzed. The dispersion relation, transmission and reflection coefficients have been obtained by using the transfer matrix method. It is investigated how photonic band gap of photonic crystals will be tuned when both dielectric function {epsilon} and magnetic permeability {mu} of the constitutive materials, depend on applied magnetic field. This is shown by one dimensional photonic crystals consisting of plasma and ferrite material layers stacked alternately.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Harmonic filter for magnetic amplifier

A magnetic amplifier includes a permeable core having multiple legs. Control windings wound around separate legs are spaced apart and connected in series in an anti-symmetric relation. Harmonic filters are positioned adjacent to the control windings to attenuate even-ordered harmonics generated by alternating load current passing through a portion of the legs. The control windings bias magnetic flux arising from control current flowing through one of the control windings which is substantially equal to the biasing magnetic flux flowing into a second control winding. The flow of the control current through each of the control windings changes the reactance of the permeable core reactor by driving those portions of the permeable core that convey the biasing magnetic flux into saturation. The phasing of the control winding limits a voltage induced in the plurality of control windings caused by a magnetic flux passing around a portion of the permeable core.

42 ENGINEERING↗

Transport Upscaling under Flow Heterogeneity and Matrix-Diffusion in Three-Dimensional Discrete Fracture Networks

For this work, we investigate the combined effects of network scale flow variability and retention due to matrix-diffusion on the scaling behavior of transport through fractured media. Two of the principal mechanisms controlling the transport of solutes through fractured low-permeability media are broad distributions of flow velocities and retention times in the solid matrix. We study the relative impact of these two processes under different initial conditions using a set of three-dimensional discrete fracture network simulations. We use these simulations to develop and calibrate an upscaled continuous time random walk (CTRW) approach for advective transport based on an Ornstein-Uhlenbeck model for the particle velocities that accounts for the fracture-matrix coupling using a compound Poisson process. This CTRW model can be conditioned on the initial solute distribution and allows to observe late-time scaling behavior at distances beyond what is feasible to observe using high-fidelity direct numerical simulations. We determine that the initial distribution of particles leads to marked differences in the persistent long-term scale behavior in the solute travel time distributions, even those undergoing retention due to matrix diffusion through implementation and analysis of the model.

54 ENVIRONMENTAL SCIENCES↗

Numerical modeling study of a man-made low-permeability barrier for the compressed air energy storage in high-permeability aquifers

Compressed air energy storage (CAES) is a grid-scale energy storage technology for intermittent energy, as proven by the decades-long successful operation of two existing compressed air energy storage in cavern (CAESC) power plants. Because of the limited availability of salt domes appropriate for CAESC, the more widely available aquifers (compressed air energy storage in aquifers, CAESA) have recently attracted considerable attention as candidates for CAES. An ideal aquifer for CAESA is highly permeable around the well to facilitate easy injection and withdrawal of air, but the high-permeability region is surrounded by low-permeability zones to minimize the loss of injected air and decrease in energy efficiency. However, such ideal geological structures are not always available in nature. Therefore, the potential of creating man-made low-permeability barrier in high-permeability aquifers is very interesting. In this paper, we investigate the feasibility of man-made low-permeability barriers in high-permeability aquifers using the numerical simulator TOUGH2/Gel to calculate the three-component flow (including a miscible gelling liquid). The simulation results show that an expected low-permeability barrier can be created by injecting grout with certain properties, and the altered aquifer performs well for CAESA. Additional sensitivity studies are also performed to reveal the effects of the various factors on the success of the low-permeability barrier creation, including the critical solidification concentration, the scale factor of the time dependence of the grout viscosity, the relative density of the grout, and the volume of the follow-up water injection. The results indicate that, in a horizontal aquifer, low critical solidification concentrations, and small scale factors are generally preferred and the density of grout should be close to that of the in situ water. For the given volume of the injected grout, there is an optimal follow-up water injection that will create the largest storage space without damaging the barrier. Furthermore, these results may help to extend the candidate sites for CAESA and the prospect of large scale energy storage.

25 ENERGY STORAGE↗

Design and implementation of a shearing apparatus for the experimental study of shear displacement in rocks

Fluid flow in the subsurface is not well understood in the context of “impermeable” geologic media. This is especially true of formations that have undergone significant stress fluctuations due to injection or withdrawal of fluids that alters the localized pressure regime. When the pressure regime is altered, these formations, which are often already fractured, move via shear to reduce the imbalance in the stress state. While this process is known to happen, the evolution of these fractures and their effects on fluid transport are still relatively unknown. Numerous simulation and several experimental studies have been performed that characterize the relationship between shearing and permeability in fractures; while many of these studies utilize measurements of fluid flow or the starting and ending geometries of the fracture to characterize shear, they do not characterize the intermediate stages during shear. We present an experimental apparatus based on slight modifications to a commonly available Hassler core holder that allows for shearing of rocks, while measuring the hydraulic and mechanical changes to geomaterials during intermediate steps. The core holder modification employs the use of semi-circular end caps and structural supports for the confining membrane that allow for free movement of the sheared material while preventing membrane collapse. By integrating this modified core holder with a computed tomography scanner, we show a new methodology for understanding the interdependent behavior between fracture structure and flow properties during intermediate steps in shearing. Here, we include a case study of this device function which is shown here through shearing of a fractured shale core and simultaneous observation of the mechanical changes and evolution of the hydraulic properties during shearing.

58 GEOSCIENCES↗

In-Situ Stress Measurements at the Utah Frontier Observatory for Research in Geothermal Energy (FORGE) Site

A scientific injection campaign was conducted at the Utah Frontier Observatory for Research in Geothermal Energy (FORGE) site in 2017 and 2019. The testing included pump-in/shut-in, pump-in/flowback, and step rate tests. Various methods have been employed to interpret the in-situ stress from the test dataset. This study focuses on methods to interpret the minimum in-situ stress from step rate, pump-in/extended shut-in tests data obtained during the stimulation of two zones in Well 58-32. This well was drilled in low-permeability granitoid. A temperature of 199 °C was recorded at the well’s total depth of 2297 m relative to the rotary Kelly bushing (RKB). The lower zone (Zone 1) consisted of 46 m of the openhole at the toe of the well. Fractures in the upper zone (Zone 2) were stimulated between 2123–2126 m measured depths (MD) behind the casing. The closure stress gradient variation depended on the depth and the injection chronology. The closure stress was found to increase with the pumping rate/volume. This stress variation could indicate that poroelastic effects (“back stress”) and the presence of adjacent natural fractures may play an important role in the interpretation of fracture closure stress. Further, progressively increasing local total stresses may, consequently, have practical applications when moderate volumes of fluid are injected in a naturally fractured or high-temperature reservoir. The alternative techniques that use pump-in/flowback tests and temperature signatures provide a valuable perspective view of the in-situ stress measurements.

15 GEOTHERMAL ENERGY↗

Permeability and Induced Polarization of Mudstones

Electrical measurements can be used to estimate hydraulic properties such as permeability ( k ) in sedimentary rocks. Previous work has focused on sandstones, siltstones, and carbonates, while investigations on mudstones have rarely been reported. In this study, we report on electrical geophysical measurements for 23 mudstone samples using an experimental approach designed to reliably saturate these low permeability mudstones. The modified Hagen-Poiseuille model linking permeability to the formation factor ( F ) and an effective pore radius ( r ) provides an excellent fit to the data set with a near-constant pore radius, indicating that the effective porosity (1/ F ) is the controlling factor on k . In these samples, the surface area normalized to pore volume ( S por ), frequently used in permeability estimation models, varies by 1–2 orders of magnitude and is thus not a reliable proxy of the inverse effective hydraulic radius. The formation factor also exerts the primary control on induced polarization (IP) parameters, whereas Spor shows no relation to the IP parameters. A strong linear relationship is found between IP parameters (imaginary conductivity and normalized chargeability) and surface conductivity, although the proportionality factor is significantly lower than those observed in more permeable rocks and sediments. Apparent relationships between the polarization strength-derived and time constant-derived geophysical length scales and the effective hydraulic radius appear to be driven by variations in the electrochemical parameters (i.e., specific polarizability and diffusion coefficient). Overall, these findings emphasize that predicting hydraulic properties from electrical measurements in fine-grained rocks remains challenging and requires further investigation into the electrochemical properties involved.

58 GEOSCIENCES↗

CO{sub 2} reaction with hydrated class H well cement under geologic sequestration conditions: effects of flyash admixtures

The rate and mechanism of reaction of pozzolan-amended Class H cement exposed to both supercritical CO{sub 2} and CO{sub 2}-saturated brine were determined under geologic sequestration conditions to assess the potential impact of cement degradation in existing wells on CO{sub 2} storage integrity. The pozzolan additive chosen, Type F flyash, a by-product of coal combustion, is the most common additive used in cements for well sealing in oil-gas field operations. The 35:65 and 65:35 (v/v) pozzolan-cement blends were exposed to supercritical CO{sub 2} and CO{sub 2}-saturated brine and underwent cement carbonation. Extrapolation of the carbonation rate for the 35:65 case suggests a penetration depth of 170-180 mm for both the CO{sub 2}-saturated brine and supercritical CO{sub 2} after 30 years. Despite alteration in both pozzolan systems, the reacted cement remained relatively impermeable to fluid flow after exposure to brine solution saturated with CO{sub 2}, with values well below the American Petroleum Institute recommended maximum well cement permeability of 200 {mu}D. Analyses of 50:50 pozzolan-cement cores from a production well in a sandstone reservoir exhibited carbonation and low permeability to brine solution saturated with CO{sub 2}, which are consistent with our laboratory findings. 16 refs., 4 figs., 1 tab.

01 COAL, LIGNITE, AND PEAT↗

Solubility and near-equilibrium dissolution rates of quartz in dilute NaCl solutions at 398-473 K under alkaline conditions.

The dissolution-precipitation of quartz controls porosity and permeability in many lithologies and may be the best studied mineral-water reaction. However, the rate of quartz-water reaction is relatively well characterized far from equilibrium but relatively unexplored near equilibrium. We present kinetic data for quartz as equilibrium is approached from undersaturation and more limited data on the approach from supersaturated conditions in 0.1 molal NaCl + NaOH + NaSiO(OH){sub 3} solutions with pH 8.2-9.7 at 398, 423, 448, and 473 K. We employed a potentiometric technique that allows precise determination of solution speciation within 2 kJ mol{sup -1} of equilibrium without the need for to perturb the system through physical sampling and chemical analysis. Slightly higher equilibrium solubilities between 423 and 473 K were found than reported in recent compilations. Apparent activation energies of 29 and 37 kJ mol{sup -1} are inferred for rates of dissolution at two surface sites with different values of connectedness: dissolution at Q{sup 1} or Q{sup 2} silicon sites, respectively. The dissolution mechanism varies with DG such that reactions at both sites control dissolution up until a critical free energy value above which only reactions at Q{sup 1} sites are important. When our near-equilibrium dissolution rates are extrapolated far from equilibrium, they agree within propagated uncertainty at 398 K with a recently published model by Bickmore et al. (2008). However, our extrapolated rates become progressively slower than model predictions with increasing temperature. Furthermore, we see no dependence of the postulated Q{sup 1} reaction rate on pH, and a poorly-constrained pH dependence of the postulated Q{sup 2} rate. Our slow extrapolated rates are presumably related to the increasing contribution of dissolution at Q{sup 3} sites far from equilibrium. The use of the potentiometric technique for rate measurement will yield both rate data and insights into the mechanisms of dissolution over a range of chemical affinity. Such measurements are needed to model the evolution of many natural systems quantitatively.

58 GEOSCIENCES↗

Regression-based reduced-order models to predict transient thermal output for enhanced geothermal systems

Reduced-order modeling is a promising approach, as many phenomena can be described by a few parameters/mechanisms. An advantage and attractive aspect of a reduced-order model is that it is computational inexpensive to evaluate when compared to running a high-fidelity numerical simulation. A reduced-order model takes couple of seconds to run on a laptop while a high-fidelity simulation may take couple of hours to run on a high-performance computing cluster. The goal of this paper is to assess the utility of regression-based reduced-order models (ROMs) developed from high-fidelity numerical simulations for predicting transient thermal power output for an enhanced geothermal reservoir while explicitly accounting for uncertainties in the subsurface system and site-specific details. Numerical simulations are performed based on equally spaced values in the specified range of model parameters. Key sensitive parameters are then identified from these simulations, which are fracture zone permeability, well/skin factor, bottom hole pressure, and injection flow rate. We found the fracture zone permeability to be the most sensitive parameter. The fracture zone permeability along with time, are used to build regression-based ROMs for the thermal power output. The ROMs are trained and validated using detailed physics-based numerical simulations. Finally, predictions from the ROMs are then compared with field data. We propose three different ROMs with different levels of model parsimony, each describing key and essential features of the power production curves. The coefficients in the proposed regression-based ROMs are developed by minimizing a non-linear least-squares misfit function using the Levenberg–Marquardt algorithm. The misfit function is based on the difference between numerical simulation data and reduced-order model. ROM-1 is constructed based on polynomials up to fourth order. ROM-1 is able to accurately reproduce the power output of numerical simulations for low values of permeabilities and certain features of the field-scale data. ROM-2 is a model with more analytical functions consisting of polynomials up to order eight, exponential functions and smooth approximations of Heaviside functions, and accurately describes the field-data. At higher permeabilities, ROM-2 reproduces numerical results better than ROM-1, however, there is a considerable deviation from numerical results at low fracture zone permeabilities. ROM-3 consists of polynomials up to order ten, and is developed by taking the best aspects of ROM-1 and ROM-2. ROM-1 is relatively parsimonious than ROM-2 and ROM-3, while ROM-2 overfits the data. ROM-3 on the other hand, provides a middle ground for model parsimony. Based on R 2 -values for training, validation, and prediction data sets we found that ROM-3 is better model than ROM-2 and ROM-1. For predicting thermal drawdown in EGS applications, where high fracture zone permeabilities (typically greater than 10 –15 m 2 ) are desired, ROM-2 and ROM-3 outperform ROM-1. As per computational time, all the ROMs are 10 4 times faster when compared to running a high-fidelity numerical simulation. In conclusion, this makes the proposed regression-based ROMs attractive for real-time EGS applications because they are fast and provide reasonably good predictions for thermal power output.

58 GEOSCIENCES↗

Systematic Studies of the Gas Humidification Effects on Spatial PEMFC Performance Distributions

The overall current density that is measured in a proton exchange membrane fuel cell (PEMFC) represents the average of the local reaction rates. The overall and local PEMFC performances are determined by several primary loss mechanisms, namely activation, ohmic, and mass transfer. Spatial performance and loss variabilities are significant and depend on the cell design and operating conditions. A segmented cell system was used to quantify different loss distributions along the gas channel to understand the effects of gas humidification. A reduction in the reactant stream humidification decreased cell performance and resulted in non-uniform distributions of overpotentials and performance along the flow field. Activation and ohmic overpotentials increased with a relative humidity decrease due to insufficient membrane and catalyst layer hydration. The relative humidity of the cathode had a strong impact on the mass transfer overpotential due to a lower oxygen permeability through the dry Nafion film covering the catalyst surface. The mass transfer loss distribution was non-uniform, and the mass transfer overpotential increased for the outlet segments due to the oxygen consumption at the inlet segments, which reduced the oxygen concentration downstream, and a progressive water accumulation from upstream segments. Electrochemical impedance spectroscopy (EIS) and an equivalent electric circuit (EEC) facilitated the analysis and interpretation of the segmented cell data.

08 HYDROGEN↗

IR spectroscopic quantification of small molecule transport and desorption phenomena in polymers

The application, continued performance, and degradation behavior of polymers often depends on their interaction with small organic or gaseous volatiles. Understanding the underlying permeation and diffusion properties of materials is crucial for predicting their barrier properties (permeant flux), drying behavior, solvent loss or tendency to trap small molecules, as well as their interaction with materials in the vicinity due to off-gassing phenomena, perhaps leading to compatibility concerns. Further, the diffusion of low Mw organics is also important for mechanistic aspects of degradation processes. Based on our need for improved characterization methods, a FTIR-based spectroscopic gas/volatile quantification setup was designed and evaluated for determination of the diffusion, desorption and transport behavior of small IR-active molecules in polymers. At the core of the method, a modified, commercially available IR transmission gas cell monitors time-dependent gas concentration. Appropriate experimental conditions, e.g. desorption or permeation under continuous flow or static gas conditions, are achieved using easily adaptable external components such as flow controllers and sample ampoules. This study presents overview approaches using the same IR detection methodology to determine diffusivity (desorption into a static gas environment, continuous gas flow, or intermittent desorption) and permeability (static and dynamic flow detection). Further, the challenges encountered for design and setup of IR gas quantification experiments, related to calibration and gas interaction, are presented. These methods establish desorption and permeation behavior of solvents (water and methanol), CO 2 off-gassing from foam, and offer simultaneous measurements of the permeation of several gases in a gas mixture (CO 2 , CO and CH 4 ) through polymer films such as epoxy and Kapton. They offer complementary guidance for material diagnostics and understanding of basic properties in sorption and transport behavior often of relevance to polymer degradation or materials reliability phenomena.

36 MATERIALS SCIENCE↗

Gas diffusion ultrabarriers on polymer substrates using Al{sub 2}O{sub 3} atomic layer deposition and SiN plasma-enhanced chemical vapor deposition

Thin films grown by Al{sub 2}O{sub 3} atomic layer deposition (ALD) and SiN plasma-enhanced chemical vapor deposition (PECVD) have been tested as gas diffusion barriers either individually or as bilayers on polymer substrates. Single films of Al{sub 2}O{sub 3} ALD with thicknesses of >=10 nm had a water vapor transmission rate (WVTR) of <=5x10{sup -5} g/m{sup 2} day at 38 deg. C/85% relative humidity (RH), as measured by the Ca test. This WVTR value was limited by H{sub 2}O permeability through the epoxy seal, as determined by the Ca test for the glass lid control. In comparison, SiN PECVD films with a thickness of 100 nm had a WVTR of approx7x10{sup -3} g/m{sup 2} day at 38 deg. C/85% RH. Significant improvements resulted when the SiN PECVD film was coated with an Al{sub 2}O{sub 3} ALD film. An Al{sub 2}O{sub 3} ALD film with a thickness of only 5 nm on a SiN PECVD film with a thickness of 100 nm reduced the WVTR from approx7x10{sup -3} to <=5x10{sup -5} g/m{sup 2} day at 38 deg. C/85% RH. The reduction in the permeability for Al{sub 2}O{sub 3} ALD on the SiN PECVD films was attributed to either Al{sub 2}O{sub 3} ALD sealing defects in the SiN PECVD film or improved nucleation of Al{sub 2}O{sub 3} ALD on SiN.

36 MATERIALS SCIENCE↗

Geological activity shapes the microbiome in deep-subsurface aquifers by advection

Subsurface environments host diverse microorganisms in fluid-filled fractures; however, little is known about how geological and hydrological processes shape the subterranean biosphere. Here, we sampled three flowing boreholes weekly for 10 mo in a 1478-m-deep fractured rock aquifer to study the role of fracture activity (defined as seismically or aseismically induced fracture aperture change) and advection on fluid-associated microbial community composition. We found that despite a largely stable deep-subsurface fluid microbiome, drastic community-level shifts occurred after events signifying physical changes in the permeable fracture network. The community-level shifts include the emergence of microbial families from undetected to over 50% relative abundance, as well as the replacement of the community in one borehole by the earlier community from a different borehole. Null-model analysis indicates that the observed spatial and temporal community turnover was primarily driven by stochastic processes (as opposed to deterministic processes). We, therefore, conclude that the observed community-level shifts resulted from the physical transport of distinct microbial communities from other fracture(s) that outpaced environmental selection. Given that geological activity is a major cause of fracture activity and that geological activity is ubiquitous across space and time on Earth, our findings suggest that advection induced by geological activity is a general mechanism shaping the microbial biogeography and diversity in deep-subsurface habitats across the globe.

59 BASIC BIOLOGICAL SCIENCES↗

High-temperature low-humidity proton exchange membrane with “stream-reservoir” ionic channels for high-power-density fuel cells

The perfluorosulfonic acid (PFSA) proton exchange membrane (PEM) is the key component for hydrogen fuel cells (FCs). We used in situ synchrotron scattering to investigate the PEM morphology evolution and found a “stream-reservoir” morphology, which enables efficient proton transport. The short-side-chain (SSC) PFSA PEM is fabricated under the guidance of morphology optimization, which delivered a proton conductivity of 193 milliSiemens per centimeter [95% relativity humidity (RH)] and 40 milliSiemens per centimeter (40% RH) at 80°C. The improved glass transition temperature, water permeability, and mechanical strength enable high-temperature low-humidity FC applications. Performance improvement by 82.3% at 110°C and 25% RH is obtained for SSC-PFSA PEM FCs compared to Nafion polymer PEM devices. The insights in chain conformation, packing mechanism, crystallization, and phase separation of PFSAs build up the structure-property relationship. In addition, SSC-PFSA PEM is ideal for high-temperature low-humidity FCs that are needed urgently for high-power-density and heavy-duty applications.

25 ENERGY STORAGE↗

Conceptual design for a blanket tritium extraction test stand

Tritium breeding is fundamentally required for a sustainable fusion fuel cycle, yet the technological readiness of blanket technology lags far behind other fusion systems. Breeder concepts are divided into solid and liquid media, where solid breeders typically rely on a sweep gas, such as helium, to carry away tritium from lithium containing ceramic materials, and liquid breeders produce tritium from lithium containing eutectics (e.g., PbLi) or molten salts (FLiBe). In each case, tritium must be harvested from the breeding medium. A promising method for tritium extraction is through a vacuum permeator, in which a concentration gradient from the tritium- containing fluid promotes diffusion through a membrane with high hydrogen permeability to the vacuum. This technology has been demonstrated for hydrogen gas systems using Pd and PdAg permeators, but relatively little work has been done to test tritium extraction from PbLi. A Tritium Extraction eXperimental (TEX) loop is being designed to test tritium extraction in a vacuum permeator configuration. The system design is such that it will allow the testing of tritium extraction from both helium and PbLi. A phased approach is being taken that will allow testing of small specimens for fundamental permeation measurements, to multi-meter component testing at near-prototypic conditions. A molten PbLi loop is challenging due to the toxic and explosive nature of Pb and Li, respectively, radiological concerns by introducing tritium, and high temperatures involved in such a system. In addition, PbLi corrosion is a significant issue at high temperatures (>400C). The TEX system will not employ a neutron source for volumetric production of tritium. Herein we present the design and methods used for 1) pumping PbLi, 2) introducing deuterium or tritium into the PbLi, 3) quantifying the amount of deuterium in the loop, 4) extracting deuterium and tritium, and 5) quantifying the total amount of extracted deuterium or tritium from the permeator. In addition, the safety design for operating such a system will be discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗