Search NASA⌕ Search

SEARCH · Search NASA

Results for “Response Spectra”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Comparison of secondary neutron dose in proton therapy resulting from the use of a tungsten alloy MLC or a brass collimator system

Purpose: To apply the dual ionization chamber method for mixed radiation fields to an accurate comparison of the secondary neutron dose arising from the use of a tungsten alloy multileaf collimator (MLC) as opposed to a brass collimator system for defining the shape of a therapeutic proton field. Methods: Hydrogenous and nonhydrogenous ionization chambers were constructed with large volumes to enable measurements of absorbed doses below 10{sup -4} Gy in mixed radiation fields using the dual ionization chamber method for mixed-field dosimetry. Neutron dose measurements were made with a nominal 230 MeV proton beam incident on a closed tungsten alloy MLC and a solid brass block. The chambers were cross-calibrated against a {sup 60}Co-calibrated Farmer chamber in water using a 6 MV x-ray beam and Monte Carlo simulations were performed to account for variations in ionization chamber response due to differences in secondary neutron energy spectra. Results: The neutron and combined proton plus {gamma}-ray absorbed doses are shown to be nearly equivalent downstream from either a closed tungsten alloy MLC or a solid brass block. At 10 cm downstream from the distal edge of the collimating material the neutron dose from the closed MLC was (5.3 {+-} 0.4) x 10{sup -5} Gy/Gy. The neutron dose with brass was (6.4 {+-} 0.7) x 10{sup -5} Gy/Gy. Further from the secondary neutron source, at 50 cm, the neutron doses remain close for both the MLC and brass block at (6.9 {+-} 0.6) x 10{sup -6} Gy/Gy and (6.3 {+-} 0.7) x 10{sup -6} Gy/Gy, respectively. Conclusions: The dual ionization chamber method is suitable for measuring secondary neutron doses resulting from proton irradiation. The results of measurements downstream from a closed tungsten alloy MLC and a brass block indicate that, even in an overly pessimistic worst-case scenario, secondary neutron production in a tungsten alloy MLC leads to absorbed doses that are nearly equivalent to those seen from brass collimators. Therefore, the choice of tungsten alloy in constructing the leaves of a proton MLC is appropriate, and does not lead to a substantial increase in the secondary neutron dose to the patient compared to that generated in a brass collimator.

61 RADIATION PROTECTION AND DOSIMETRY↗

Characterization of a clinical unit for digital radiography based on irradiation side sampling technology

Purpose: A characterization of a clinical unit for digital radiography (FUJIFILM FDR D-EVO) is presented. This system is based on the irradiation side sampling (ISS) technology and can be equipped with two different scintillators: one traditional gadolinium-oxysulphide phosphor (GOS) and a needle structured cesium iodide (CsI) phosphor panel.Methods: The characterization was achieved in terms of response curve, modulation transfer function (MTF), noise power spectra (NPS), detective quantum efficiency (DQE), and psychophysical parameters (contrast-detail analysis with an automatic reading of CDRAD images). For both scintillation screens the authors accomplished the measurements with four standard beam conditions: RAQ3, RQA5, RQA7, and RQA9.Results: At the Nyquist frequency (3.33 lp/mm) the MTF is about 35% and 25% for CsI and GOS detectors, respectively. The CsI scintillator has better noise properties than the GOS screen in almost all the conditions. This is particularly true for low-energy beams, where the noise for the GOS system can go up to a factor 2 greater than that found for CsI. The DQE of the CsI detector reaches a peak of 60%, 60%, 58%, and 50% for the RQA3, RQA5, RQA7, and RQA9 beams, respectively, whereas for the GOS screen the maximum DQE is 40%, 44%, 44%, and 35%. The contrast-detail analysis confirms that in the majority of cases the CsI scintillator is able to provide improved outcomes to those obtained with the GOS screen.Conclusions: The limited diffusion of light produced by the ISS reading makes possible the achievement of very good spatial resolution. In fact, the MTF of the unit with the CsI panel is only slightly lower to that achieved with direct conversion detectors. The combination of very good spatial resolution, together with the good noise properties reached with the CsI screen, allows achieving DQE on average about 1.5 times greater than that obtained with GOS. In fact, the DQE of unit equipped with CsI is comparable to the best alternative methods available which are based on the same technology, and similar to others based on an a-Se direct conversion detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photoluminescence properties of thallium-containing GeSe{sub 2} and GeSe{sub 3} vitreous semiconductors

The photoluminescence properties of thallium-containing vitreous semiconductor systems with stoichiometric and nonstoichiometric compositions (GeSe{sub 2}){sub 1–x}Tl{sub x} and (GeSe{sub 3}){sub 1–x}Tl{sub x} (0 ⩽ x ⩽ 0.1) are studied at a temperature of T = 77 K. Intrinsic defects with negative correlation energy are responsible for the Gaussian shape of the photoluminescence spectra. It is established that an increase in x in the systems does not affect the shape of the spectrum, does not generate new emission bands, shifts the photoluminescence spectra to the region of low energies, reduces the intensity of radiation, and increases its half-width. Kinetics of the fatigue of photoluminescence is different for both systems and is characterized by one curve irrespective of Tl content in the systems.

36 MATERIALS SCIENCE↗

Simulation of SPND Beta-Current in AP1000 core

The Self-Powered Neutron Detectors (SPNDs) are widely used in Generation-III commercial PWR due to its small size and external-power free character. It can measure the in-core neutron flux density immediately to obtain the power profile in the core. To better understand the actual state of the simulated core, a SPND beta-current simulation module has been established in the NECP-Bamboo code. Firstly, neutron simulation is carried out in the lattice code Bamboo-Lattice together with nuclide depletion simulation to obtain the depleted composition of the entire lattice including the SPND, and the few-group parameters including density and cross section of emitter material. Secondly, the depleted lattice can then be piped into a Monte-Carlo code for neutron-photon-electron simulation to obtain the electron escape efficiency from the emitter of the SPND to the corresponding collector. Thirdly, the electron escape efficiency can be parameterized into the function of the lattice state parameters similarly to the common few-group constants. Finally, the beta-current was calculated by the core code Bamboo-Core simultaneously with the simulation of the core operation process. The beta-current of the Vanadium SPND in the AP1000 core was simulated and analyzed in this paper. Comparison between simulation and measurement of the beta-current distribution in the specific core state is shown in this paper to verify the effectiveness of the method and the code. The radial normalized current distribution is in good agreement with the measurement. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Data Assimilation using Non-invasive Monte Carlo Sensitivity Analysis of Reactor Kinetics Parameters [Slides]

Sensitivity coefficients of prompt neutron decay constant (α) and effective delayed neutron fraction (β eff ) to Pu-239 nuclear data were calculated using a newly available tool (ACEtk). Uncertainty calculations showed the following trends: (1) The prompt neutron decay constant can be used to reduce nuclear data-induced uncertainty in Pu-239(n,f) and (2) the effective delayed neutron fraction can be used to effectively reduce nuclear data-induced uncertainty in Pu-239 total fission $\tilde{v}$. Sensitivity/uncertainty analysis can be used to determine optimal experiment/detector setup to identify compensating errors in nuclear data. Upcoming work includes investigating other nuclide-reaction pairs and response sensitivities, such as Δ$\rho$, neutron leakage spectra, and reaction rate measurements to constrain nuclear data of interest.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Chemical Analysis of Fluorobenzenes via Multinuclear Detection in the Strong Heteronuclear J-Coupling Regime

Chemical analysis via nuclear magnetic resonance (NMR) spectroscopy using permanent magnets, rather than superconducting magnets, is a rapidly developing field. Performing the NMR measurement in the strong heteronuclear J-coupling regime has shown considerable promise for the chemical analysis of small molecules. Typically, the condition for the strong heteronuclear J-coupling regime is satisfied at µT magnetic field strengths and enables high resolution J-coupled spectra (JCS) to be acquired. However, the JCS response to systematic chemical structural changes has largely not been investigated. In this report, we investigate the JCS of C6H6−xFx (x = 0, 1, 2, …, 6) fluorobenzene compounds via simultaneous excitation and detection of 19F and 1H at 51.5 µT. The results demonstrate that JCS are quantitative, and the common NMR observables, including Larmor frequency, heteronuclear and homonuclear J-couplings, relative signs of the J-coupling, chemical shift, and relaxation, are all measurable and are differentiable between molecules at low magnetic fields. The results, corroborated by ab initio calculations, provide new insights into the impact of chemical structure and their corresponding spin systems on JCS. In several instances, the JCS provided more chemical information than traditional high field NMR, demonstrating that JCS can be used for robust chemical analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fluorescence spectroscopy.

Some practical aspects of the use of spectrophotofluorometers as applied to the organic analyses of returned lunar samples and other geological materials have been discussed. Because of the single beam nature of spectrophotofluorometers many instrumental artifacts such as grating anomalies, irregular spectral output of light sources and response characteristics of photodetectors are apparent in sample spectra. In order to avoid some of these instrumental artifacts from influencing sample spectra, the performance characteristics of each optical component have been described and the necessity of instrumental calibration has been emphasized.

Rho, J. H.↗

Spectrometry of Jupiter at selected locations on the disk during the 1979 apparition

Jupiter's reflectivity was measured as a function of wavelength between 3000 and 10,500 Angstrom for two nights during the 1979 apparition. The spectra obtained were used to calibrate the wavelength response of Voyager images and to establish differences from previous apparitions. The observations were taken in the prominent belts and zones and both polar caps along the central meridian using a slit of dimensions 2.33 x 2.5 sq arcsec. The equivalent widths of the 6190 and 7270 Angstrom CH4 bands were measured; compared to the 1976 apparition, there was significantly less CH4 absorption in the north tropical zone. Such equivalent-width decreases are said to result from either a reduction in particle albedo or a decrease in the scattering mean free path owing to a greater concentration of aerosol particles in the NTrZ.

Cochran, A. L.↗

Spectroscopy from 2 to 200 keV

The astrophysical processes responsible for line and continuum emission in the spectra range 2 keV to 200 keV are examined from the viewpoint of designing a spectrometer which would operate in this regime. Phenomena considered include fluorescent line radiation in X-ray binaries, magnetically shifted iron lines and cyclotron emission from neutron star surfaces, line emission from cosmically abundant elements in thermal plasmas, and nuclear deexcitation lines in fresh nucleosynthetically produced matter. An instrument consisting of a approximately 10 sq cm array of planar germanium detectors surrounded by a large sodium-iodide anticoincidence shield is described and projected background rates and sensitivities are considered. A sample observing program for a two-day shuttle-based mission is included as an example of the wide range of scientific questions which could be addressed by such an instrument.

Helfand, D. J.↗

Generalized modal shock spectra within indeterminate interface

It is noted that the generalized modal shock spectra method had limitations on the degree of structural static determinacy of the spacecraft-to-launch-vehicle interface. The 'interface modes' is used here to remove these practical limitations. The governing differential equations are derived and then shown to be valid either for integrating the modal models of two or more substructures that have been previously obtained separately or for removing a substructure from a previously available system modal model. Emphasis is placed on the integration problems in the context of the generalized modal shock spectra approach. A minimum of information the modal response of a previously obtained transient analysis of the unloaded launch vehicle is exploited in order to define an idealized modal impulse function and derive approximate explicit expressions for an estimate of the bounds of the spacecraft response. In addition, a numerical model is solved in order to compare the present results with the transient solution.

Salama, M.↗

Approximate Simulation of Turbulence

Computed spectra resemble von Karman spectra of frequencies of interest. Numerical technique yields simulated atmospheric-turbulence spectra that closely approximates von Karman spectra within frequency ranges of interest for aircraft response. Suitable for computation in that they represent stable systems and roll off as f-2 at high frequencies outside range of interest.

Campbell, C. W.↗

An anemometer for highly turbulent or recirculating flows

An anemometer which determines flow velocity by ionizing air and sensing the convective displacement of the ions is described. It is suited to measurement in low speed, highly unsteady gas flows. Comparisons to hot wire spectra suggest the corona anemometer has adequate frequency response to make it a useful tool for fluid dynamics measurement.

Durbin, P. A.↗

Disk-instability model for soft-X-ray transients containing black holes

Consideration is given to the time-dependent behavior of the accretion disks in low-mass X-ray binaries as a model for soft X-ray transients. The thermal stability and vertical structure properties of the disk are studied in the range between 10 to the 7th and 10 to the 8th cm. An Eulerian time-dependent thin disk model is used to show that, for relevant accretion rates, the disk suffers a thermal instability leading to intermittent accretion onto the central compact object. The disk instability model reproduces the basic features of outbursts of soft X-ray transients. Also, the physical state of quiescence of the binary A0620-00 is examined, focusing on the possible existence of a black hole. It is suggested that the modulation of the accretion flow in the inner disk may be responsible for the bimodal behavior observed in the spectra of black hole candidates such as Cyg X-1, GX 339-4, and A0620-00.

Mineshige, Shin↗

Variable Intrinsic UV Absorption in the Seyfert 1.5 Galaxy NGC 3516

We have examined the physical conditions in the intrinsic UV absorbing gas in the Seyfert 1.5 galaxy NGC 3516, using echelle spectra obtained with the Space Telescope Imaging Spectrograph aboard the Hubble Space Telescope on 2000 October 1. We confirm the presence of the 4 kinematic components detected in earlier Goddard High Resolution Spectrograph (GHRS) spectra, as well as 4 new absorption features with radial velocities ranging from -692 to -1372 kilometers per second. The C IV column densities of components 3 and 4 appear to have increased significantly compared to the GHRS epoch. Based on photoionization modeling and our analysis of contemporaneous Chandra X-ray Observatory spectra, we argue that these changes are in response to the drop in ionizing flux.

Kraemer, S. B.↗

Orthostatic intolerance and motion sickness after parabolic flight

Because it is not clear that the induction of orthostatic intolerance in returning astronauts always requires prolonged exposure to microgravity, we investigated orthostatic tolerance and autonomic cardiovascular function in 16 healthy subjects before and after the brief micro- and hypergravity of parabolic flight. Concomitantly, we investigated the effect of parabolic flight-induced vomiting on orthostatic tolerance, R-wave-R-wave interval and arterial pressure power spectra, and carotid-cardiac baroreflex and Valsalva responses. After parabolic flight 1) 8 of 16 subjects could not tolerate 30 min of upright tilt (compared to 2 of 16 before flight); 2) 6 of 16 subjects vomited; 3) new intolerance to upright tilt was associated with exaggerated falls in total peripheral resistance, whereas vomiting was associated with increased R-wave-R-wave interval variability and carotid-cardiac baroreflex responsiveness; and 4) the proximate mode of new orthostatic failure differed in subjects who did and did not vomit, with vomiters experiencing comparatively isolated upright hypocapnia and cerebral vasoconstriction and nonvomiters experiencing signs and symptoms reminiscent of the clinical postural tachycardia syndrome. Results suggest, first, that syndromes of orthostatic intolerance resembling those developing after space flight can develop after a brief (i.e., 2-h) parabolic flight and, second, that recent vomiting can influence the results of tests of autonomic cardiovascular function commonly utilized in returning astronauts.

NASA Center JSC↗

Acoustic Measurements from Wind Tunnel Test of AMELIA - Advanced Model for Extreme Lift and Improved Aeroacoustics

A wind tunnel test has been conducted to measure the aerodynamic and acoustic performance of an active circulation-control aircraft with leading- and trailing- edge slot blowing. The 11 Advanced Model for Extreme Lift and Improved Aeroacoustics (AMELIA) model was tested in the Arnold Engineering Development Center (AEDC) National Full Scale Aerodynamics Complex (NFAC) 40- by 80-Ft wind tunnel. Forward velocities ranged from 0 to Mach 0.15 and total slot mass-flow was varied from 0 to 2.8 lbmsec. Angle-of-attack and sideslip ranges were -5 to 25 and -10 to 10, respectively.This reports summarizes acoustic measurements from the wind tunnel test and the corrections applied to the released acoustic data. The analysis focuses on measurements for the clean wing configuration (turbine propulsion simulators removed) with trailing-and leading-edge slot blowing and with trailing-edge blowing, for systematic variations in slot mass flow from nearly zero to the system maximum. The acoustic measurements from a fixed phased microphone array and seven fixed microphones were corrected for sensor directional response and atmospheric attenuation. Graphs of 13-octave spectra, narrowband spectra, and directional variations in OASPL are presented for each active lift configuration. This report is intended to document the corresponding set of corrected data that is now available for development and verification of new predictive models of the active lift source.For large slot mass flow conditions 13-octave spectral shapes were level and flat, typical of a pink noise source. Little source directivity was present in the OASPL levels for the 0 flap conditions and show only a slight downstream increase with the 60 flap configuration. For moderate to high slot mass flow conditions trailing-edge only blowing spectra were similar to leading- and trailing edge blowing cases. However for the lower mass flows variations of as much as 5 dB were observed.

CCW↗

THE He II POST-REIONIZATION EPOCH: HST/COS OBSERVATIONS OF THE QUASAR HS1700+6416

The reionization epoch of singly ionized helium (He II) is believed to start at redshifts z {approx} 3.5-4 and be nearly complete by z {approx_equal} 2.7. We explore the post-reionization epoch with far-ultraviolet spectra of the bright, high-redshift quasar HS1700+6416 taken by the Cosmic Origins Spectrograph (COS) on the Hubble Space Telescope, which show strong He II ({lambda}303.78) absorption shortward of the QSO redshift, z{sub QSO} = 2.75. We discuss these data as they probe the post-reionization history of He II and the local ionization environment around the quasar and transverse to the line of sight, finding that quasars are likely responsible for much of the ionization. We compare previous spectra taken by the Far-Ultraviolet Spectroscopic Explorer to the current COS data, which have a substantially higher signal-to-noise ratio. The Gunn-Peterson trough recovers at lower redshifts, with the effective optical depth falling from {tau}{sub eff} {approx_equal} 1.8 at z {approx} 2.7 to {tau}{sub eff} {approx_equal} 0.7 at z {approx} 2.3, higher than has been reported in earlier work. We see an interesting excess of flux near the He II Ly{alpha} break, which could be quasar line emission, although likely not He II Ly{alpha}. We present spectra of four possible transverse-proximity quasars, although the UV hardness data are not of sufficient quality to say if their effects are seen along the HS1700 sightline.

79 ASTRONOMY AND ASTROPHYSICS↗