Search NASA⌕ Search

SEARCH · Search NASA

Results for “SAFETY DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Wind Turbine Gust Load Alleviation with Active Flow Control

Large wind turbine rotors are becoming more common in utility-scale wind power, especially for offshore wind plants. However, the trend toward large rotors can be limited by their ability to manage dynamic and extreme loads. To provide a safety margin for the rotor design and avoid catastrophic events such as tower strikes, extreme loads need to be controlled. The objective of this study is to develop and evaluate a feedback control system to alleviate extreme loads and reduce blade deflections under gust events using active flow control devices. We also propose a modification in the turbine controller to achieve further reduction in extreme loads. The extreme load reductions are evaluated under gust wind conditions with direction changes according to the IEC standard. The effects of the gust alleviation controller on turbine performance and fatigue loads are investigated as well. With the deployment of the gust alleviation controller and modified turbine baseline controller, the extreme loads and deflections reduce by up to 23%. The energy captured by the turbine is not affected by the proposed gust alleviation controller. The fatigue loads of various wind turbine components are either reduced or remain unchanged.

17 WIND ENERGY↗

Technology Integration Initiative In Support of Outage Management

Plant outage management is a high priority concern for the nuclear industry from cost and safety perspectives. Often, command and control during outages is maintained in the outage control center where many of the underlying technologies supporting outage control are the same as those used in the 1980’s. This research reports on the use of advanced integrating software technologies and hand held mobile devices as a means by which to reduce cycle time, improve accuracy, and enhance transparency among outage team members. This paper reports on the first phase of research supported by the DOE Light Water Reactor Sustainability (LWRS) Program that is performed in close collaboration with industry to examine the introduction of newly available technology allowing for safe and efficient outage performance. It is thought that this research will result in: improved resource management among various plant stakeholder groups, reduced paper work, and enhanced overall situation awareness for the outage control center management team. A description of field data collection methods, including personnel interview data, success factors, end-user evaluation and integration of hand held devices in achieving an integrated design are also evaluated. Finally, the necessity of obtaining operations cooperation support in field studies and technology evaluation is acknowledged.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

WE-G-BRC-00: Experiences with TG100 in Clinical Use

Failure Mode and Effects Analysis (FMEA) originated as an industrial engineering technique used for risk management and safety improvement of complex processes. In the context of radiotherapy, the AAPM Task Group 100 advocates FMEA as the framework of choice for establishing clinical quality management protocols. However, there is concern that widespread adoption of FMEA in radiation oncology will be hampered by the perception that implementation of the tool will have a steep learning curve, be extremely time consuming and labor intensive, and require additional resources. To overcome these preconceptions and facilitate the introduction of the tool into clinical practice, the medical physics community must be educated in the use of this tool and the ease in which it can be implemented. Organizations with experience in FMEA should share their knowledge with others in order to increase the implementation, effectiveness and productivity of the tool. This session will include a brief, general introduction to FMEA followed by a focus on practical aspects of implementing FMEA for specific clinical procedures including HDR brachytherapy, physics plan review and radiosurgery. A description of common equipment and devices used in these procedures and how to characterize new devices for safe use in patient treatments will be presented. This will be followed by a discussion of how to customize FMEA techniques and templates to one’s own clinic. Finally, cases of common failure modes for specific procedures (described previously) will be shown and recommended intervention methodologies and outcomes reviewed. Learning Objectives: Understand the general concept of failure mode and effect analysis Learn how to characterize new equipment for safety Be able to identify potential failure modes for specific procedures and learn mitigation techniques Be able to customize FMEA examples and templates for use in any clinic.

60 APPLIED LIFE SCIENCES↗

WE-G-BRC-01: Risk Assessment for Radiosurgery

Failure Mode and Effects Analysis (FMEA) originated as an industrial engineering technique used for risk management and safety improvement of complex processes. In the context of radiotherapy, the AAPM Task Group 100 advocates FMEA as the framework of choice for establishing clinical quality management protocols. However, there is concern that widespread adoption of FMEA in radiation oncology will be hampered by the perception that implementation of the tool will have a steep learning curve, be extremely time consuming and labor intensive, and require additional resources. To overcome these preconceptions and facilitate the introduction of the tool into clinical practice, the medical physics community must be educated in the use of this tool and the ease in which it can be implemented. Organizations with experience in FMEA should share their knowledge with others in order to increase the implementation, effectiveness and productivity of the tool. This session will include a brief, general introduction to FMEA followed by a focus on practical aspects of implementing FMEA for specific clinical procedures including HDR brachytherapy, physics plan review and radiosurgery. A description of common equipment and devices used in these procedures and how to characterize new devices for safe use in patient treatments will be presented. This will be followed by a discussion of how to customize FMEA techniques and templates to one’s own clinic. Finally, cases of common failure modes for specific procedures (described previously) will be shown and recommended intervention methodologies and outcomes reviewed. Learning Objectives: Understand the general concept of failure mode and effect analysis Learn how to characterize new equipment for safety Be able to identify potential failure modes for specific procedures and learn mitigation techniques Be able to customize FMEA examples and templates for use in any clinic.

60 APPLIED LIFE SCIENCES↗

WE-G-BRC-02: Risk Assessment for HDR Brachytherapy

Failure Mode and Effects Analysis (FMEA) originated as an industrial engineering technique used for risk management and safety improvement of complex processes. In the context of radiotherapy, the AAPM Task Group 100 advocates FMEA as the framework of choice for establishing clinical quality management protocols. However, there is concern that widespread adoption of FMEA in radiation oncology will be hampered by the perception that implementation of the tool will have a steep learning curve, be extremely time consuming and labor intensive, and require additional resources. To overcome these preconceptions and facilitate the introduction of the tool into clinical practice, the medical physics community must be educated in the use of this tool and the ease in which it can be implemented. Organizations with experience in FMEA should share their knowledge with others in order to increase the implementation, effectiveness and productivity of the tool. This session will include a brief, general introduction to FMEA followed by a focus on practical aspects of implementing FMEA for specific clinical procedures including HDR brachytherapy, physics plan review and radiosurgery. A description of common equipment and devices used in these procedures and how to characterize new devices for safe use in patient treatments will be presented. This will be followed by a discussion of how to customize FMEA techniques and templates to one’s own clinic. Finally, cases of common failure modes for specific procedures (described previously) will be shown and recommended intervention methodologies and outcomes reviewed. Learning Objectives: Understand the general concept of failure mode and effect analysis Learn how to characterize new equipment for safety Be able to identify potential failure modes for specific procedures and learn mitigation techniques Be able to customize FMEA examples and templates for use in any clinic.

60 APPLIED LIFE SCIENCES↗

WE-G-BRC-03: Risk Assessment for Physics Plan Review

Failure Mode and Effects Analysis (FMEA) originated as an industrial engineering technique used for risk management and safety improvement of complex processes. In the context of radiotherapy, the AAPM Task Group 100 advocates FMEA as the framework of choice for establishing clinical quality management protocols. However, there is concern that widespread adoption of FMEA in radiation oncology will be hampered by the perception that implementation of the tool will have a steep learning curve, be extremely time consuming and labor intensive, and require additional resources. To overcome these preconceptions and facilitate the introduction of the tool into clinical practice, the medical physics community must be educated in the use of this tool and the ease in which it can be implemented. Organizations with experience in FMEA should share their knowledge with others in order to increase the implementation, effectiveness and productivity of the tool. This session will include a brief, general introduction to FMEA followed by a focus on practical aspects of implementing FMEA for specific clinical procedures including HDR brachytherapy, physics plan review and radiosurgery. A description of common equipment and devices used in these procedures and how to characterize new devices for safe use in patient treatments will be presented. This will be followed by a discussion of how to customize FMEA techniques and templates to one’s own clinic. Finally, cases of common failure modes for specific procedures (described previously) will be shown and recommended intervention methodologies and outcomes reviewed. Learning Objectives: Understand the general concept of failure mode and effect analysis Learn how to characterize new equipment for safety Be able to identify potential failure modes for specific procedures and learn mitigation techniques Be able to customize FMEA examples and templates for use in any clinic.

60 APPLIED LIFE SCIENCES↗

Liquid metal walls

Here, the plasma performance of fusion devices depends strongly on the chosen wall materials. Solid plasma-facing components (PFCs) are predominantly used in present devices, and are the most investigated candidates for fusion designs. High-Z materials such as tungsten (W) are the leading solid PFC material candidates. To date, a material choice that scales to steady-state reactor conditions has not been identified. Moreover, if plasma transient events such as edge-localized modes and disruptions cannot be altogether avoided or sufficiently mitigated, the projected peak heat and particle loads far exceed the power exhaust capabilities of solids. Liquid metal (LM) PFCs represent an intrinsic self-healing boundary that are both resilient to surface damage from transients, and that could handle high steady-state heat and particle fluxes. Flowing LM PFCs can be designed to remove “slag,” the buildup of material erosion due to plasma-material interactions, including charge exchange sputtering in the main chamber. Further, LM offer the prospect to manage hydrogenic species otherwise retained in the PFCs, which is important from a safety and inventory standpoint. The two most promising LMs are lithium (Li) and tin (Sn), although Sn–Li eutectics may be considered. While Sn offers a higher temperature window with low vapor pressure and low hydrogen retention, Li offers the prospect of enhanced energy confinement and higher acceptable core contamination limits, and this section focuses on Li PFCs. An LM PFC development research program developed LM PFC concepts for a nuclear fusion device via engineering design calculations, single-effect experiments, and staged prototypical experiments. A self-consistent design window was identified with liquid Li flow speeds ~5–10 m/s; plasma contamination was negligible for predicted Li evolution rates. While these preconceptual designs hold promise, there is substantial R&D needed to advance the technical readiness levels of LM PFCs for application to fusion power plants.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First observation of currents induced by Alfven eigenmodes in a magnetic confinement device

Instabilities driven by energetic particles normally reduce fusion power but recent studies find Alfven eigenmode instabilities can drive ``zonal" flows and currents that reduce thermal transport, improving overall performance. Motional Stark effect (MSE) data from the DIII-D tokamak reveal changes in magnetic pitch angle during the phase when Alfven-eigenmode nonlinearity drives zonal flows, suppresses microturbulence, and increases the electron and ion temperatures. Finally, measured changes in safety factor of ∆q/q ≃ 5% occur in roughly 20 ms, consistent with a rough estimate based on the measured zonal flow.

Heidbrink, W. W. [Univ. of California, Irvine, CA ↗

Transitioning from Cobalt-60 to X-Ray or E-Beam for Medical Sterilization: Filling Data and Education Gaps

The Office of Radiological Security (ORS) within the U.S. DOE’s National Nuclear Security Administration (NNSA) is charged to “work with government, law enforcement, and businesses across the globe to protect radioactive sources used for medical, research, and commercial purposes; remove and dispose of disused radioactive sources; and reduce the global reliance on high activity radioactive sources through the promotion of viable non-radioisotopic alternative technologies.” In this effort, the NNSA/ORS, along with the Office of Defense Nuclear Nonproliferation R&D, has been working with government and private entities that utilize gamma-ray irradiators in areas that include blood irradiation, radiotherapy, biology research, well logging, and radiation processing to consider alternative technologies that do not depend upon radioactive materials. In the medical device industry, nearly 50% of products are sterilized with ethylene oxide, 40.5% with cobalt-60 gamma-rays, 4.5% with electron-beam (e-beam), and <1% with X-ray.(1,2) The cobalt-60 irradiation facilities use an estimated 150 MCi of isotope to sterilize approximately 200 million cubic feet of product annually.(3) Due to growing safety regulations governing cobalt-60 use, continued advancements in e-beam and X-ray accelerator technology, and the greater irradiation durations and costs for cobalt-60 irradiation compared to e-beam and X-ray, switching to these non-radionuclide modalities is increasingly economically competitive. However, this breakdown of 40.5% cobalt-60 and 5.5% accelerator for product sterilization illustrates the difficulty that market forces and industry players have had in overcoming barriers in transitioning to non-nuclide alternatives. Besides those associated with construction of new e-beam and X-ray facilities, significant financial and regulatory obstacles are also associated with the irradiation and comprehensive testing of product constituent polymers and elastomers. The standards associated with product material performance testing are the Association for the Advancement of Medical Instrumentation (AAMI) Technical Information Report 17 (TIR 17), and its referenced American Society for Testing and Materials (ASTM) polymer testing standards. In the study now underway, and the subject of this article, the NNSA/ORS provided R&D funding to the Pacific Northwest National Laboratory (PNNL) in partnership with university researchers, leading medical product manufacturers, accelerator manufacturers, and contract sterilizers. The resulting Team Nablo (in memory of Sam Nablo) includes individuals representing PNNL, Becton Dickinson (BD), Johnson & Johnson, Stryker, Texas A&M University (TAMU), Steri-Tek, Mevex, Ion Beam Applications (IBA), and Sterigenics. The goals of this study are to 1) Identify specific polymer and/or elastomer-based medical products that are currently sterilized with gamma-rays, and for which there are data gaps and would be of greatest industry impact, 2) Work with relevant ASTM subcommittees for guidance and for potential standard revision, 3) Work with an appropriate Food & Drug Administration (FDA) office for potential collaboration on a guidance document for device manufacturers, 4) Measure the physical effects that product materials exhibit when they are given sterilization-level radiation doses from cobalt-60, e-beam or X-ray, and determine whether these effects would preclude the use of e-beam or X-ray for sterilization, 5) Communicate the resulting scientific datasets and findings via industry conferences, peer-reviewed journals, and relevant trade magazines, and 6) Post the resulting datasets on a publicly accessible website, which can be built on in future years. The end objective is to identify technical barriers preventing the adoption of X-ray and e-beam technologies, and share the results to encourage X-ray and e-beam adoption where feasible.

sterilization, alternate technologies, gamma, X-ra↗

Role of a continuous MHD dynamo in the formation of 3D equilibria in fusion plasmas

Stationary 3D equilibria can form in fusion plasmas via saturation of magnetohydrodynamic (MHD) instabilities or stimulated by external 3D fields. In these cases the current profile is anomalously broad due to magnetic flux pumping produced by the MHD modes. Flux pumping plays an important role in hybrid tokamak plasmas, maintaining the minimum safety factor above unity and thus removing sawteeth. It also enables steady-state hybrid operation, by redistributing non-inductive current driven near the center by electron cyclotron waves. A validated flux pumping model is not yet available, but it would be necessary to extrapolate hybrid operation to future devices. In this work flux pumping physics is investigated for helical core equilibria stimulated by external 3D fields in DIII-D hybrid plasmas. We show that flux pumping can be produced in a continuous way by an MHD dynamo emf. The same effect maintains helical equilibria in reversed-field pinch (RFP) plasmas. The effective MHD dynamo loop voltage is calculated for experimental 3D equilibrium reconstructions, by balancing Ohm’s law over helical flux surfaces, and is consistent with the expected current redistribution. Similar results are also obtained with more sophisticated nonlinear MHD simulations. The same modelling approach is applied to helical RFP states forming spontaneously in RFX-mod as the plasma current is raised above 0.8–1 MA. This comparison allows to identify the underlying physics common to tokamak and RFP: a helical core displacement modulates parallel current density along flux tubes, which requires a helical electrostatic potential to build up, giving rise to a helical MHD dynamo flow.

3D equilibrium reconstruction↗

Understanding the Dynamics of Primary Zn-MnO 2 Alkaline Battery Gassing with Operando Visualization and Pressure Cells

The leading cause for safety vent rupture in alkaline batteries is the intrinsic instability of Zn in the highly alkaline reacting environment. Zn and aqueous KOH react in a parasitic process to generate hydrogen gas, which can rupture the seal and vent the hydrogen along with small amounts of electrolyte, and thus, damage consumer devices. Abusive conditions, particularly deep discharge, are known to accelerate this “gassing” phenomena. In order to understand the fundamental drivers and mechanisms for such gassing behavior, the results from multiphysics modeling, ex-situ microscopy and operando measurements of cell potential, pressure and visualization have been combined. Operando measurements were enabled by the development a new research platform that enables a cross-sectional view of a cylindrical Zn-MnO 2 primary alkaline battery throughout its discharge and recovery. A second version of this cell can actively measure the in-cell pressure during the discharge. It is shown that steep concentration gradients emerge during the cell discharge through a redox electrolyte mechanism, leading to the formation of high surface area Zn deposits that experience rapid corrosion when the cell rests to its open circuit voltage. Such corrosion is paired with the release of hydrogen and high cell pressure – eventually leading to cell rupture.

25 ENERGY STORAGE↗

VTO_2021_APR_LLNL_Ye

Traditional batteries are composed of two-dimensional films that are stacked and/or rolled. Thin film batteries display high power density while their thick film counterparts show good energy density, but it has proven difficult to concurrently achieve both within these planar form factors. In addition, conventional Li-ion batteries based on liquid organic electrolytes or gel polymer electrolytes have raised severe safety concerns due to the intrinsic flammable properties of the organic electrolytes. They are also not ideal for the use of high energy density metallic lithium (Li) anodes due to Li dendrite growth, or sulfur cathodes due to shuttling effects that result in fast capacity fade. There is an urgent need to develop safe, high-performance solid-state batteries (SSBs) with advanced electrolyte and separator technologies. Although in recent years a series of superionic conductors have been developed for electrolytes and separators, their performance does not satisfy demanding criteria due to large impedance from poor solid electrolyte-electrode contact and questionable electrochemical and mechanical stability. Unlike the well-established roll-to-roll fabrication of conventional Li-ion batteries, the processing of SSBs is unique due to the brittleness of solid-state electrolytes (SSEs). The commercially available or lab-developed SSE discs are usually very thick (hundreds of micrometers to millimeters) to overcome their brittle nature, which unfortunately increases the cell impedance and accounts for the majority of the overall cell weight and volume, leading to dramatically decreased power and energy densities. In this project, we will investigate 3D printing techniques to overcome safety, fabrication, mechanical, and electrochemical issues in SSBs. 3D printing builds complex structures in a layer-by-layer fashion, which allows rapid production of hierarchical architectures, gradient and multi-material structures, and multi-component assemblies. 3D printing is an emerging area that could fundamentally transform energy storage devices. For example, 3D printing can produce batteries with arbitrary form factors to fit a product’s specific volume requirements and can create interwoven electrode arrangements over a wide range of length scales to improve transport and increase power density for a given energy density. For SSBs, 3D printing may dramatically reduce the separator thickness from ~1 mm (by hydraulic pressing) to tens of micrometers or less. In addition, the interfacial contact area between the electrolyte and the electrode may be increased via 3D interdigitated designs. Hence, we expect a significant reduction of the overall cell impedance and enhancement of both energy and power densities of SSBs by harnessing an array of 3D printing technologies being developed at Lawrence Livermore National Laboratory (LLNL).

25 ENERGY STORAGE↗

Deployment of Diamond-Based Radiation Detector for Very High Dose Rate Measurements - 17042

The diamond-based radiation detector system has been developed at the University of Bristol to measure radiation within nuclear facilities known to exhibit high dose rates. The challenge at Sellafield site in the UK, described herein also applies to many other nuclear operators worldwide, making the transfer of diamond detector technology to other applications feasible. Development of an operator-friendly system, extensive detector testing and controlled calibrations have led to several successful deployments of the device at Sellafield site, providing them with valuable data about the radiological contamination within their highly active plants. Designed for measurements of intense radiation fields, this new tool for characterisation of radiologically hazardous environments is a game-changer, improving the availability and quality of dose rate data used in safety case justifications. Compared with conventional technology diamond detectors are radiation tolerant, miniature, and can measure an extraordinary range of dose rates. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electromagnetic compatibility qualification of power electronics for I and C power applications - 152

Electromagnetic Compatibility (EMC) is a growing field in nuclear equipment qualification. Previously confined to I and C equipment residing in control and cable spreading rooms, EMC qualification has expanded to include the inverters and battery chargers which often power safety-related I and C equipment, as well as adjustable speed drives and material handling equipment which could potentially affect sensitive safety-related I and C systems. Because much of the data collected to form the current EMC limits and guidance was collected from low-power equipment in relatively low EMI environments, the same guidance, applied to power electronic equipment, produces overly conservative estimations of the performance needed for EMC. Excessive modification in an attempt to bring the equipment into compliance with EMC limits may not be necessary. This paper provides a brief summary of current applicable EMC guidance and demonstrates a road map for the qualification of larger, more powerful devices which takes into account the entire EMC process, including design, testing, mapping of the installed location, and justification of EMC failures with the end goal being successful, timely, and cost-effective implementation of upgrades and compatibility with existing plant infrastructure (in the intended installation environment), even if equipment exceeds traditional operating envelopes. (authors)

42 ENGINEERING↗

Optimising National WM Strategies through early consideration of Nuclear Safeguards - 18607

International Atomic Energy Agency (IAEA) safeguards stand alongside safety and security as one of the three pillars for prudent management of all nuclear material, including nuclear waste. Although safety considerations, including public and environmental radiation protection, are the traditional drivers of waste management strategies, there is a requirement for nuclear safeguards in shaping and quantifying long-term solutions for special classes of radioactive waste. This is especially important when considering the disposal of nuclear material in a repository that could be released from regulatory oversight for radiation protection after a period of institutional control, as some safeguards oversight would still be required. Failure to consider nuclear safeguards at the early stages of planning may alternatively lead to excessive volumes for disposal or the need to recondition already treated wastes. At the very least, safeguards measures should be considered before countries seek to dispose of legacy nuclear materials, decommissioning wastes and other materials containing uranium, thorium or plutonium in an operating repository. Nuclear safeguards are the set of tools and techniques used by the IAEA to verify that countries comply with their international obligations not to divert nuclear materials to nuclear explosive devices. Under the Nuclear Non-Proliferation Treaty (NPT), nuclear safeguards apply to all uranium, thorium and plutonium held in non-weapons NPT states, with limited exceptions. In nuclear-weapon states, much of their material is likewise subject to IAEA safeguards through conditions in agreements with respective suppliers of the uranium. Under IAEA safeguards, such nuclear material must remain accounted for and accessible for periodic verification-analogous to the safety concepts of reversibility and retrievability. Nevertheless, safeguards requirements can be terminated - provided that the State and the [IAEA] agree that such nuclear material is practicably irrecoverable - through dilution or immobilisation in solid form (such as cement, glass or ceramic). This means candidate material can be disposed of as non- nuclear material, with no further safeguards requirements, provided this criterion is met. Unlike radiological wastes where repository design strongly influences pathways for radionuclide migration and overall safety performance, repository design is not a factor in considering the termination of safeguards on nuclear material. This paper looks at similarities and differences in the safety, security and safeguards regulatory requirements for the management of radioactive waste and nuclear material in Australia. In particular, it outlines recent experience gained from participation in Australia's waste acceptance criteria working group for a national low-level waste repository and intermediate-level waste store, as well as from Australia's overall waste management strategy. These items of work have coincided with the IAEA update of its internal policy on termination of safeguards on nuclear material. Australia's experience shows how inclusion of safeguards criteria in the planning process is leading to optimisations in choice of facility concepts, project sequencing and equitable distribution of economic risk. By considering the three pillars-safety, security and safeguards-early on in the planning process, Australia's waste management strategy will provide a benchmark for other states in establishing and updating their own waste acceptance criteria for the disposal of nuclear material. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

AREVA NP MR Cladding benefits for proposed US NRC RIA and LOCA requirements

M5 is the reference alloy of AREVA NP for PWR cladding applications. It is a zirconium-based alloy containing 1% niobium, no tin, and well-controlled oxygen, iron, and sulfur contents. It has a fully recrystallized microstructure. The absence of tin in M5 results in a very low corrosion rate and hydrogen pick-up during normal operation, even at high burn-up and in high duty irradiation conditions. Due to this low hydrogen pick-up under irradiation (typically less than 100 ppm, End of Life), M5 retains a very good strength and an exceptional residual ductility during and after the accident. This allows utilities implementing M5 to simplify the safety analysis and to demonstrate significant margins regarding fuel related criteria. Simplified methods are easier for plants to implement and maintain for future plant operations and core design management. This paper specifically presents 3 examples on the safety improvement brought by M5 cladding. First, during a reactivity-induced accident (RIA), the properties of M5 are such that bounding analyses for future cycles are significantly simplified, in particular by demonstrating that fuel dispersal will not occur. The major aspects of the AREVA NP RIA methodology are presented. A second focus is made on the low hydrogen embrittlement of M5 and on its high ductility after quenching during a loss-of-coolant accident (LOCA). In a third part, the breakaway oxidation testing program currently under development in Paimboeuf (France) is described, including details about the testing devices and qualification. The tests have demonstrated that M5 cladding does not have breakaway at least up to 5000 s oxidation duration at 1000 C. degrees, which is much higher than the LOCA duration.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Human electromagnetic field exposure in wearable communications systems: A review

While wearable technologies have taken essential parts of our daily lives, concerns on human health are often overseen. Mainly due to extreme proximity or direct physical contact to human skin, wearable communications devices are prone to cause higher levels of electromagnetic field (EMF) exposure at human skin surface than any other type of wireless technologies. Nevertheless, while focusing on theoretical aspects of human EMF exposure in wearable communications, prior work paid little to no attention on exact exposure levels generated by commercial wearable devices that are already widely used by public consumers. In this context, this paper provides an extensive review of SAR from various commercial wearable devices that are currently sold in the market, as well as the analytical framework and the current measurement methodologies for standard compliance tests. To extend the discussion to general wearable communications, this paper presents simulation results adopting representative antenna patterns, which leads to suggestion of separation distances to keep the current safety guidelines. In particular, considering the increasing interest in millimeter wave (mmW), this paper sheds light on EMF exposure evaluated at 60 GHz and compares to results from 2.4 GHz.

42 ENGINEERING↗

Functional integrity of flexible n-channel metal–oxide–semiconductor field-effect transistors on a reversibly bistable platform

Flexibility can bring a new dimension to state-of-the-art electronics, such as rollable displays and integrated circuit systems being transformed into more powerful resources. Flexible electronics are typically hosted on polymeric substrates. Such substrates can be bent and rolled up, but cannot be independently fixed at the rigid perpendicular position necessary to realize rollable display-integrated gadgets and electronics. A reversibly bistable material can assume two stable states in a reversible way: flexibly rolled state and independently unbent state. Such materials are used in cycling and biking safety wristbands and a variety of ankle bracelets for orthopedic healthcare. They are often wrapped around an object with high impulsive force loading. Here, we study the effects of cumulative impulsive force loading on thinned (25 μm) flexible silicon-based n-channel metal–oxide–semiconductor field-effect transistor devices housed on a reversibly bistable flexible platform. We found that the transistors have maintained their high performance level up to an accumulated 180 kN of impact force loading. The gate dielectric layers have maintained their reliability, which is evidenced by the low leakage current densities. Also, we observed low variation in the effective electron mobility values, which manifests that the device channels have maintained their carrier transport properties.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗