Search NASA⌕ Search

SEARCH · Search NASA

Results for “SIZE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

SU-D-201-04: Study On the Impact of Tumor Shape and Size On Drug Delivery to Pancreatic Tumors

Purpose: Drug delivery to solid tumors can be expressed physically using transport phenomena such as convection and diffusion for the drug of interest within extracellular matrices. We aimed to carefully model these phenomena, and to investigate the effect of tumor shape and size on drug delivery to solid tumors in the pancreas. Methods: In this study, multiple tumor geometries as obtained from clinical PET/CT images were considered. An advanced numerical method was used to simultaneously solve fluid flow and solute transport equations. Data from n=45 pancreatic cancer patients with non-resectable locoregional disease were analyzed, and geometrical information from the tumors including size, shape, and aspect ratios were classified. To investigate effect of tumor shape, tumors with similar size but different shapes were selected and analyzed. Moreover, to investigate effect of tumor size, tumors with similar shapes but different sizes, ranging from 1 to 77 cm{sup 3}, were selected and analyzed. A hypothetical tumor similar to one of the analyzed tumors, but scaled to reduce its size below 0.2 cm{sup 3}, was also analyzed. Results: The results showed relatively similar average drug concentration profiles in tumors with different sizes. Generally, smaller tumors had higher absolute drug concentration. In the hypothetical tumor, with volume less than 0.2 cm{sup 3}, the average drug concentration was 20% higher in comparison to its counterparts. For the various real tumor geometries, however, the maximum difference between average drug concentrations was 10% for the smallest and largest tumors. Moreover, the results demonstrated that for pancreatic tumors the shape is not significant. The negligible difference of drug concentration in different tumor shapes was due to the minimum effect of convection in pancreatic tumors. Conclusion: In tumors with different sizes, smaller tumors have higher drug delivery; however, the impact of tumor shape in the case of pancreatic tumors is not significant.

60 APPLIED LIFE SCIENCES↗

SU-F-T-628: An Evaluation of Grid Size in Eclipse AcurosXB Dose Calculation Algorithm for SBRT Lung

Purpose: purpose of this study is to evaluate the effect of grid size in Eclipse AcurosXB dose calculation algorithm for SBRT lung. Methods: Five cases of SBRT lung previously treated have been chosen for present study. Four of the plans were 5 fields conventional IMRT and one was Rapid Arc plan. All five cases have been calculated with five grid sizes (1, 1.5, 2, 2.5 and 3mm) available for AXB algorithm with same plan normalization. Dosimetric indices relevant to SBRT along with MUs and time have been recorded for different grid sizes. The maximum difference was calculated as a percentage of mean of all five values. All the plans were IMRT QAed with portal dosimetry. Results: The maximum difference of MUs was within 2%. The time increased was as high as 7 times from highest 3mm to lowest 1mm grid size. The largest difference of PTV minimum, maximum and mean dose were 7.7%, 1.5% and 1.6% respectively. The highest D2-Max difference was 6.1%. The highest difference in ipsilateral lung mean, V5Gy, V10Gy and V20Gy were 2.6%, 2.4%, 1.9% and 3.8% respectively. The maximum difference of heart, cord and esophagus dose were 6.5%, 7.8% and 4.02% respectively. The IMRT Gamma passing rate at 2%/2mm remains within 1.5% with at least 98% points passing with all grid sizes. Conclusion: This work indicates the lowest grid size of 1mm available in AXB is not necessarily required for accurate dose calculation. The IMRT passing rate was insignificant or not observed with the reduction of grid size less than 2mm. Although the maximum percentage difference of some of the dosimetric indices appear large, most of them are clinically insignificant in absolute dose values. So we conclude that 2mm grid size calculation is best compromise in light of dose calculation accuracy and time it takes to calculate dose.

60 APPLIED LIFE SCIENCES↗

[ 18 F](2 S ,4 R )4-Fluoroglutamine PET Detects Glutamine Pool Size Changes in Triple-Negative Breast Cancer in Response to Glutaminase Inhibition

Glutaminolysis is a metabolic pathway adapted by many aggressive cancers, including triple-negative breast cancers (TNBC), to utilize glutamine for survival and growth. In this study, we examined the utility of [ 18 F](2S,4R)4-fluoroglutamine ([ 18 F]4F-Gln) PET to measure tumor cellular glutamine pool size, whose change might reveal the pharmacodynamic (PD) effect of drugs targeting this cancer-specific metabolic pathway. High glutaminase (GLS) activity in TNBC tumors resulted in low cellular glutamine pool size assayed via high-resolution 1 H magnetic resonance spectroscopy (MRS). GLS inhibition significantly increased glutamine pool size in TNBC tumors. MCF-7 tumors, with inherently low GLS activity compared to TNBC, displayed a larger baseline glutamine pool size that did not change as much in response to GLS inhibition. The tumor-to-blood-activity-ratios (T/B) obtained from [ 18 F]4F-Gln PET images matched the distinct glutamine pool sizes of both tumor models at baseline. After a short course of GLS inhibitor treatment, the T/B values increased significantly in TNBC, but did not change in MCF-7 tumors. Across both tumor types and after GLS inhibitor or vehicle treatment, we observed a strong positive correlation between T/B values and tumor glutamine pool size measured using MRS ( r 2 =0.71). In conclusion, [ 18 F]4F-Gln PET tracked cellular glutamine pool size in breast cancers with differential GLS activity and detected increases in cellular glutamine pool size induced by GLS inhibitors. This work accomplished the first necessary step towards validating [ 18 F]4F-Gln PET as a PD marker for glutaminase-targeting drugs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Large Gap Size Paired-end Library Construction for Second Generation Sequencing

Fosmid or BAC end sequencing plays an important role in de novo assembly of large genomes like fungi and plants. However construction and Sanger sequencing of fosmid or BAC libraries are laborious and costly. The current 454 Paired-End (PE) Library and Illumina Jumping Library construction protocols are limited with the gap sizes of approximately 20 kb and 8 kb, respectively. In the attempt to understand the limitations of constructing PE libraries with greater than 30Kb gaps, we have purified 18, 28, 45, and 65Kb sheared DNA fragments from yeast and circularized the ends using the Cre-loxP approach described in the 454 PE Library protocol. With the increasing fragment sizes, we found a general trend of decreasing library quality in several areas. First, redundant reads and reads containing multiple loxP linkers increase when the average fragment size increases. Second, the contamination of short distance pairs (<10Kb) increases as the fragment size increases. Third, chimeric rate increases with the increasing fragment sizes. We have modified several steps to improve the quality of the long span PE libraries. The modification includes (1) the use of special PFGE program to reduce small fragment contamination; (2) the increase of DNA samples in the circularization step and prior to the PCR to reduce redundant reads; and (3) the decrease of fragment size in the double SPRI size selection to get a higher frequency of LoxP linker containing reads. With these modifications we have generated large gap size PE libraries with a much better quality.

59 BASIC BIOLOGICAL SCIENCES↗

The size evolution of star-forming galaxies since z ∼ 7 using ZFOURGE

For the first time, we present the size evolution of a mass-complete (log(M{sub *}/M{sub ⊙}) > 10) sample of star-forming galaxies over redshifts z = 1–7, selected from the FourStar Galaxy Evolution Survey. Observed H-band sizes are measured from the Cosmic Assembly Near-infrared Deep Extragalactic Legacy Survey (CANDELS) Hubble Space Telescope (HST)/F160W imaging. Distributions of individual galaxy masses and sizes illustrate that a clear mass−size relation exists up to z ∼ 7. At z ∼ 7, we find that the average galaxy size from the mass−size relation is more compact at a fixed mass of log(M{sub *}/M{sub ⊙}) = 10.1, with r{sub 1/2,maj}=1.02±0.29 kpc, than at lower redshifts. This is consistent with our results from stacking the same CANDELS HST/F160W imaging, when we correct for galaxy position angle alignment. We find that the size evolution of star-forming galaxies is well fit by a power law of the form r{sub e}=7.07(1+z){sup −0.89} kpc, which is consistent with previous works for normal star-formers at 1 < z < 4. In order to compare our slope with those derived Lyman break galaxy studies, we correct for different IMFs and methodology and find a slope of −0.97 ± 0.02, which is shallower than that reported for the evolution of Lyman break galaxies (LBGs) at z > 4 (r{sub e}∝(1+z){sup −1.2±0.06}). Therefore, we conclude the LBGs likely represent a subset of highly star-forming galaxies that exhibit rapid size growth at z > 4.

79 ASTRONOMY AND ASTROPHYSICS↗

Reduction in bearing size due to superconductors in magnetic bearings

A design concept that reduces the size of magnetic bearings is assessed. The small size will enable magnetic bearings to fit into limited available bearing volume of cryogenic machinery. The design concept, called SUPERC, uses (high Tc) superconductors or high-purity aluminum conductors in windings instead of copper. The relatively high-current density of these conductors reduces the slot radial thickness for windings, which reduces the size of the bearings. MTI developed a sizing program called SUPERC that translates the high-current density of these conductors into smaller sized bearings. This program was used to size a superconducting bearing to carry a 500 lb. load. The sizes of magnetic bearings needed by various design concepts are as follows: SUPERC design concept = 3.75 in.; magnet-bias design concept = 5.25 in.; and all electromagnet design concept = 7.0 in. These results indicate that the SUPERC design concept can significantly reduce the size of the bearing. This reduction, in turn, reduces the weight and yields a lighter bearing. Since the superconductors have inherently near-zero resistance, they are also expected to save power needed for operation considerably.

Rao, Dantam K.↗

Estimation of grain sizes and mixing ratios of fine powder mixtures of common geologic minerals

Two different approaches for modeling reflectance spectra of intimate mixtures, Hapke's model and the isograin model, are used to estimate grain sizes and mixing ratios of powder mixtures of three geologic minerals: olivine, orthopyroxene, and plagioclase. In Hapke's model, scattering and extinction effiencies are mixed separately, and both models employ semiempirical refractive index spectra for component minerals. Mixing ratios of mixtures of grain size 45-75 micrometers are well estimated by both models assuming a common grain size of 60 micrometers and optimizing the constants for the single-particle scattering. For each model, effective grain size ratios for mineral constituents in mixtures of grain size less than 25 micrometers, are derived successfully that allows mineral abundances to be accurately predicted within approximately 4 wt percent. On the other hand, neither model can accurately predict mineral reflectance spectra for its smaller grain sizes less than 25 and 25-45 micrometers using an absorption coefficient spectrum derived from a larger grain size (45-75 micrometers). The errors in both models are significantly reduced if surface roughness effects of the smaller grain-size fractions are modeled.

Hiroi, Takahiro↗

The Effect of Set Size on the Relation Between Saccadic and Perceptual Decisions During Search

We have shown that when searching for a disk in noise at one of 10 locations, the accuracy of the I st saccade is similar to that of the perceptual decision at the time of saccadic programming. The present study has two goals: 1) to test whether this linden - extends to a contrast-discrimination task without noise, and 2) to measure the effect of set size on the relation between saccadic and perceptual decisions. Methods: Three observers searched over a grey background (34.5 cd/sq m) for a bright disk (63.2 cd/sq m) among dim disks (54.1 cd/sq m) along the circumference of a circle (r = 5.9 deg.) centered on a fixation cress. Four set sizes (2, 4, 6, 12) were used. In the 1st condition, stimuli were presented for 1 sec. and observers used natural eye movements. We then measured the accuracy of the first saccade (% correct using a shortest-distance criterion). In the 2nd condition, observers fixated a central cross at all times and the stimulus duration was approx. 70 as less than the median latency of the first saccade in the 1st condition (saccadic programming time). We then recorded perceptual performance and discarded trials in which observers broke fixation. Results: For set sizes of 2, 4, 8, and 12, the mean d' across observers for the perceptual decision was 2.03, 1.96, 1.94, 1.71, respectively, while the mean d' of the first saccade was only 0.73, 1.40, 1.23, 1.17. Conclusions: Unlike detection of a disk in noise, for all observers and set-sizes, the perceptual accuracy at the time of saccadic programming is better than that of the lst saccade. For set-sizes of 4, 6, and 12, the amount of information available to the perceptual system relative to that available to the saccadic system is approximately constant (fixed do ratio). For these higher set sizes, the constancy in do across set size for both perception and saccadic decisions is consistent with a simple signal detection theory (SDT) model that processes noisy signals in parallel. However, for 2 observers, at a set-size of 2, saccadic targeting appears to be worse than the SDT model prediction, perhaps due to speed-accuracy trade-off.

Eckstein, M. P.↗

3D-HST + CANDELS: the Evolution of the Galaxy Size-mass Distribution Since Z=3

Spectroscopic and photometric redshifts, stellar mass estimates, and rest-frame colors from the 3D-HST survey are combined with structural parameter measurements from CANDELS imaging to determine the galaxy size-mass distribution over the redshift (z) range 0 < z < 3. Separating early- and late-type galaxies on the basis of star-formation activity, we confirm that early-type galaxies are on average smaller than late-type galaxies at all redshifts, and find a significantly different rate of average size evolution at fixed galaxy mass, with fast evolution for the early-type population, effective radius is in proportion to (1 + z) (sup −1.48), and moderate evolution for the late-type population, effective radius is in proportion to (1 + z) (sup −0.75). The large sample size and dynamic range in both galaxy mass and redshift, in combination with the high fidelity of our measurements due to the extensive use of spectroscopic data, not only fortify previous results, but also enable us to probe beyond simple average galaxy size measurements. At all redshifts the slope of the size-mass relation is shallow, effective radius in proportion to mass of a black hole (sup 0.22), for late-type galaxies with stellar mass > 3 x 10 (sup 9) solar masses, and steep, effective radius in proportion to mass of a black hole (sup 0.75), for early-type galaxies with stellar mass > 2 x 10 (sup 10) solar masses. The intrinsic scatter is approximately or less than 0.2 decimal exponents for all galaxy types and redshifts. For late-type galaxies, the logarithmic size distribution is not symmetric, but skewed toward small sizes: at all redshifts and masses a tail of small late-type galaxies exists that overlaps in size with the early-type galaxy population. The number density of massive (approximately 10 (sup 11) solar masses), compact (effective radius less than 2 kiloparsecs) early-type galaxies increases from z = 3 to z = 1.5 − 2 and then strongly decreases at later cosmic times.

EVOLUTION↗

Spacesuit Sizing by Multivariate Simulation: Case Study for Liquid Cooling and Ventilation Garment

A technique was developed to assess the fit of spacesuit garment liquid cooling and ventilation garment (LCVG). A fit scoring scheme was built from the spacesuit sizing requirements and guidelines, and the accommodated proportion of the wearer population was estimated from statistically synthesized pseudo population data. The method evaluated different scenarios of LCVG sizing systems including 1) baseline 7-size system, 2) 7-sizes with target body dimensions iteratively adjusted for maximum fit, and 3) 9-sizes with iterative adjustments. Overall, the baseline sizing system showed 81% accommodation rate, while the hypothetical new systems in-tegrating iterative adjustments for 7- and 9-sizes predictively indicated that accommodation could improve up to 92 and 97%. The proposed method provided a structured metric to quantify fit performance of a garment sizing system, which can be further applied to different spacesuit component, PPE and garment designs.

Han Kim↗

Effect of substrate roughness, slope, and body size on climbing behavior and performance of juvenile American eels ( Anguilla rostrata )

The effect of ramp slope and substrate grain size on the passage of juvenile American Eel ( Anguilla rostrata ) over indoor ramps was tested from May – August 2016. Two size classes of fish (300 glass eels 50 – 70 mm and 300 elvers 90-114 mm), five substrates varying in coarseness (Substrate 1: 0.18-0.25 mm grain size, Substrate 2: 0.25-0.60 mm grain size, Substrate 3; 0.60-1.00 mm grain size, Substrate 4: 1.00 – 2.00 mm grain size, Substrate 5: 2.00- 4.00 mm grain size), and three ramp slopes (25, 35 and 45 degrees) were explored. Individual fish were placed at the bottom of a ramp and given 30 minutes to ascend 0.5 m. Movements over the substrate were recorded with video footage and digitized. Fish length, fish weight, water temperature, and days the fish were held in captivity before being tested were also recorded and analyzed. Results indicated that substrate had a highly significant effect on glass and elver climbing performance, and slope had an effect on elver performance but not glass eel performance. The roughest substrate yielded the highest proportion of eels ascending the entire length of the ramp and the highest climbing speed in each parameter category. Further testing with more grain sizes and longer ramp lengths are required, and mass manufacturing processes for this substrate need to be explored.

13 HYDRO ENERGY↗

Waffle Homes: Utilizing Aerial Imagery of Unfinished Buildings to Determine Average Room Size

A primary function of the Population Density Tables Project (PDT) at Oak Ridge National Laboratory is to produce residential population densities per 1000 sq. ft. for each country and their associated first-level administrative units. This is accomplished by utilizing the average size of different types of dwelling areas (urban, rural, single-family, multi-family, etc.) and the average household size provided by a country’s Census or statistical bureau records. This data is available for the majority of Europe, North America, and large swathes of Asia, but is less easily found in Africa and South America. In these regions, Censuses generally report dwelling area by number of rooms, which poses the challenging question of how we can translate number of rooms to dwelling size when no dwelling size areas are available with which to compare. Using sub-meter resolution satellite imagery of Accra, Ghana, this challenge can be tackled using imagery of roofless buildings currently under construction that show the interior floor plan of the dwelling. A sample of buildings from the different neighborhoods of Accra can be digitized to provide an estimate and range of average room sizes of dwellings. This average room size can then be translated to a total dwelling area using the "number of rooms occupied by a household" variable from the Ghanaian Census. This intermediate step between average dwelling size and number of rooms occupied, fills the missing link that prevents PDT from continually producing new population densities for countries where dwelling size is unavailable through any official means.

Woody, Carson↗

In Situ TEM Microcompression Pillar Size Effects in Fe-9Cr ODS

The objective of this paper is to ascertain the existence of a specimen size threshold, below which the material no longer exhibits bulk mechanical behavior when tested using in situ transmission electron microscopic (TEM) micro-compression pillars. In this work, sub-micron sized pillars of a model Fe-9Cr oxide dispersion strengthened (ODS) alloy were compressed in TEM in situ at room temperature, and attempts have been made to quantify the resulting data. Results are compared to mechanical property values in the archival literature, and a discussion on the validity of quantitative in situ TEM micro-compression data for ODS steel is included. In situ TEM mechanical testing is a relatively new technique enabling concurrent TEM imaging and mechanical testing of sub-micron-sized electron-transparent specimens. Due to limited sample volume of many nuclear materials, in situ TEM mechanical testing holds great promise for advancing our understanding of deformation phenomena. But it is well known that the dramatically reduced specimen size required for in situ testing can affect quantitative and qualitative deformation behaviors. However, Kiener, et al. used in situ TEM micro-compression pillars on irradiated and unirradiated single-crystal copper. They observed size independence in the irradiated material, while the unnirradiated material displayed a size threshold below which the mechanical properties deviated from those of bulk Cu. They assert that the more densely-spaced obstacles in irradiated Cu allow it to display bulk properties even in specimens having ∼ 100 nm dimensions. Similar to Kiener's findings, we hypothesize that unirradiated ODS will demonstrate a size threshold, but the in situ TEM micro-compression technique can be extended from single crystal materials to engineering alloys. An Fe-9Cr model ODS alloy was chosen for this study because of the broad interest in ODS for advanced nuclear reactors. ODS alloys exhibit high irradiation tolerance and high temperature creep resistance. New insight into deformation processes gained through in situ TEM mechanical testing could be valuable for the validation of ODS alloys for next generation nuclear reactors. The fact that the compressive yield stress and elastic modulus do not follow distinct trends as a function of specimen size is likely due to the high density of obstacles to dislocation motion. The ODS microstructure contains such obstacles as oxide nanoparticles, a fine grain structure, a high density of dislocation lines, and carbide precipitates. Since the deformation behavior is governed by the minimum separation distance between obstacles [1], it is plausible that the high obstacle density enables ODS alloy micropillars to exhibit bulk-like mechanical properties even prior to irradiation. Future work will focus on: (1) developing finite element models to help explain the difference in elastic moduli between bulk and micropillar tests, (2) understanding the spread in yield stress measurements at fixed micropillar volumes, and (3) extending this study to irradiated ODS. (authors)

36 MATERIALS SCIENCE↗

Fracture toughness of zirconia with a nanometer size notch fabricated using focused ion beam milling

Zirconia with 3 mol% yttria (3Y-TZP) has been used for dental crowns and bridges due to its excellent mechanical behavior. Performing fracture toughness testing on this nanograin material, however, can be a challenge. For reliable results, fracture toughness testing requires an extremely sharp notch in the test specimen that closely approximates a very sharp crack. This study was to investigate an alternative method to produce nanometer-sized notches, which are less than the average grain size of 3Y-TZP, during the preparation of single-edge V-notched beam specimens and report the resulting fracture toughness value. We present a method using focused ion beam (FIB) milling to fabricate nanometer-sized notches in 3Y-TZP. The notch tip is <100 nm wide, which is smaller than the grain size, and is consistent throughout the thickness of the specimen. The FIB-notched specimens show a much reduced average fracture toughness of 5.64 ± 1.14 MPa√m compared to 8.90 ± 0.23 MPa√m for the specimens without FIB-notches. The FIB-milling did not appear to create any monoclinic phase prior to fracture toughness testing. Fractures originated at the FIB-notches, and the notch size can be readily identified post-mortem using a microscope. A considerable amount of tetragonal-to-monoclinic phase transformation was observed throughout the fracture surfaces. FIB milling provides an alternative method to fabricate nanometer-sized notches that are smaller than the grain size of tetragonal zirconia polycrystal. The fracture toughness determined using FIB-notches was ~5.64 MPa√m, smaller than the specimens with V-notches fabricated using saw blades.

36 MATERIALS SCIENCE↗

Enhanced exchange bias effect in size modulated Sm{sub 0.5}Ca{sub 0.5}MnO{sub 3} phase separated manganite

The effect of grain size modulation on exchange bias effect in CE-type antiferromagnetic Sm{sub 0.5}Ca{sub 0.5}MnO{sub 3} phase separated manganite is reported here. With the reduction of particle size, ferromagnetic clusters are found to form in the charge ordered antiferromagnetic matrix and gradually become larger. The horizontal and vertical shifts of the magnetic hysteresis loops in the field cooled magnetization process clearly indicate the size dependent exchange bias effect and it can be tuned with the reduction of particle sizes. The values of exchange bias parameter, i.e., exchange bias field (H{sub E}), coercivity (H{sub C}), remanence asymmetry (M{sub E}), and magnetic coercivity (M{sub C}) are found to depend strongly on the particle size. The variations of H{sub E} follow non-monotonic dependencies with reduction in particle size and show maximum (1205 Oe) at particle size of 150 nm at T = 5 K, which can be ascribed due to the changes in uncompensated surface spins. The values of H{sub E} and M{sub E} are found to decrease exponentially with increasing temperature below the spin- or cluster-glass like freezing temperature. The spin relaxation model has been employed for analysis of large magnetic training effect. The linear relationship between H{sub E} and M{sub E} further confirms the role of uncompensated surface spins. In view of spintronics application of manganites, the present observation of large exchange bias shift in this half-doped manganite may have great technological importance.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SPLAT II: An Aircraft Compatible, Ultra-Sensitive, High Precision Instrument for In-Situ Characterization of the Size and Composition of Fine and Ultrafine Particles

The properties of aerosols depend on the size and internal compositions of the individual particles. The vast majority of atmospheric aerosols are smaller than 200 nm, yet the single particle mass spectrometers, the only instruments that can characterize the size and internal compositions of individual particles, typically detect these small particles with extremely low efficiencies. In this paper we describe a new instrument called SPLAT II that provides unparalleled sensitivity to small particles, detecting 100% of particles that are larger than 125 nm and 40% of 100 nm particles. This instrument also brings an increase by a factor of 10 in temporal resolution, sizing up to 500 particles per second and characterizing the composition of up to 100 of them. SPLAT II uses a two-laser, two-step process to evaporate the particles and generate ions, producing high quality, reproducible mass spectra of the refractive and non-refractive aerosol fractions to yield the complete compositions of individual particles. The instrument control board provides for size dependent delays for lasers’ triggers to eliminate a size dependent hit rate. The mass spectra are recorded with 14-bit vertical resolution and analyzed using custom software packages. The instrument’s high sizing resolution and sensitivity makes it possible to combine it with the differential mobility analyzer(s) and measure particle size, composition, density, dynamic shape factor, hygroscopicity, and fractal dimension.

47 OTHER INSTRUMENTATION↗

Size dependence of second-harmonic generation at the surface of microspheres

The resonance-enhanced surface second-harmonic generation (SHG) from a suspension of polystyrene microspheres was investigated as a function of particle size in a range of the order of the fundamental wavelength for two different second-harmonic-enhancing dyes--malachite green and pyridine 1. The two dyes gave the same strongly modulated pattern of the forward second-harmonic scattering efficiency. Direct comparison to the nonlinear Rayleigh-Gans-Debye (NLRGD) and nonlinear Wentzel-Kramers-Brillouin (NLWKB) model predictions showed that the NLWKB model reproduces the overall trend in the size dependence but fails with respect to the strong modulations. The standard NLRGD model was found to fail altogether in the present particle size range, which was well beyond the observed upper particle size for which the NLRGD and NLWKB models give comparable results. A generalization of the NLRGD model to allow for dispersion and to use the particle refractive indices instead of those of the surrounding medium extended its applicability range by almost an order of magnitude in particle size. There is a pronounced maximal SHG efficiency for particles with a radius that is close to the fundamental wavelength inside the particle. The optically soft particle approximation is inadequate to describe the SHG in this particle size range, as refraction and reflection of the waves at the particle surface have a decisive influence. Dispersion of the media plays a negligible role for particle sizes up to about twice the optimal one for SHG.

74 ATOMIC AND MOLECULAR PHYSICS↗

Size-dependent stochastic tensile properties in additively manufactured 316L stainless steel

Recent work in metal additive manufacturing (AM) suggests that mechanical properties may vary with feature size; however, these studies do not provide a statistically robust description of this phenomenon, nor do they provide a clear causal mechanism. Because of the huge design freedom afforded by 3D printing, AM parts typically contain a range of feature sizes, with particular interest in smaller features, so the size effect must be well understood in order to make informed design decisions. This work investigates the effect of feature size on the stochastic mechanical performance of laser powder bed fusion tensile specimens. A high-throughput tensile testing method was used to characterize the effect of specimen size on strength, elastic modulus and elongation in a statistically meaningful way. The effective yield strength, ultimate tensile strength and modulus decreased strongly with decreasing specimen size: all three properties were reduced by nearly a factor of two as feature dimensions were scaled down from 6.25 mm to 0.4 mm. Hardness and microstructural observations indicate that this size dependence was not due to an intrinsic change in material properties, but instead the effects of surface roughness on the geometry of the specimens. Finite element analysis using explicit representations of surface topography shows the critical role surface features play in creating stress concentrations that trigger deformation and subsequent fracture. The experimental and finite element results provide the tools needed to make corrections in the design process to more accurately predict the performance of AM components.

316L stainless steel↗