Search NASA⌕ Search

SEARCH · Search NASA

Results for “STORAGE DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

VIRTEX-4 VQ static SEU Characterization Summary

This report is the result of the combined efforts of members within the Xilinx Radiation Test Consortium (XRTC), sometimes known as the Xilinx SEE Test Consortium. The XRTC is a voluntary association of aerospace entities, including leading aerospace companies, universities and national laboratories, combining resources to characterize reconfigurable FPGAs for aerospace applications. Previous publications of Virtex-4 radiation results are for commercial (non-epitaxial) devices; see, for example, Refs. 1-4. A notable exception is Ref. 5, which presents XRTC upset measurements of storage elements in the PowerPC405s in the XQR4VFX60. This report of upset susceptibility to heavy ions and protons of the static memory elements in the Virtex-4QV family is a direct parallel to the XRTC report on the thin epitaxial devices in the Virtex-2 family released four years ago.

field programmable gate array (FPGA)↗

Synchronized circuit improves accuracy of fluid transfer measurements

Shut-off valve at the destination of a transferred fluid, improves the accuracy of measurements determining the quantity of liquid transferred from a storage source to a remote location. By synchronizing this valve with the measuring device /totalizer/, the inaccuracies resulting from unfilled transfer lines can be reduced.

Vendl, C. J.↗

Isolator/retainer for connectors

Double-ended cap holds mating plugs and receptacle, preventing electrical contact between them when not in use. Cap maintains continuous electrical ground between plug and receptacle protecting against electromagnetic-interference pickup. Device is also useful for isolation of sensitive circuits from each other during storage, transit, or testing.

Alpenia, J. L.↗

Flight critical system design guidelines and validation methods

Efforts being expended at NASA-Langley to define a validation methodology, techniques for comparing advanced systems concepts, and design guidelines for characterizing fault tolerant digital avionics are described with an emphasis on the capabilities of AIRLAB, an environmentally controlled laboratory. AIRLAB has VAX 11/750 and 11/780 computers with an aggregate of 22 Mb memory and over 650 Mb storage, interconnected at 256 kbaud. An additional computer is programmed to emulate digital devices. Ongoing work is easily accessed at user stations by either chronological or key word indexing. The CARE III program aids in analyzing the capabilities of test systems to recover from faults. An additional code, the semi-Markov unreliability program (SURE) generates upper and lower reliability bounds. The AIRLAB facility is mainly dedicated to research on designs of digital flight-critical systems which must have acceptable reliability before incorporation into aircraft control systems. The digital systems would be too costly to submit to a full battery of flight tests and must be initially examined with the AIRLAB simulation capabilities.

Holt, H. M.↗

Design and testing of a coaxial linear magnetic spring with integral linear motor

The design of a coaxial linear magnetic spring which incorporates a linear motor to control axial motion and overcome system damping is presented, and the results of static and dynamic tests are reported. The system has nominal stiffness 25,000 N/m and is designed to oscillate a 900-g component over a 4.6-mm stroke in a Stirling-cycle cryogenic refrigerator being developed for long-service (5-10-yr) space applications (Stolfi et al., 1983). Mosaics of 10 radially magnetized high-coercivity SmCO5 segments enclosed in Ti cans are employed, and the device is found to have quality factor 70-100, corresponding to energy-storage efficiency 91-94 percent. Drawings, diagrams, and graphs are provided.

Patt, P. J.↗

Mars rover vehicle

This year the University of Wisconsin-Madison design team studied surface operations for a Mars base. Specifically, research was conducted concerning the possibilities for a Mars Rover Sample Return mission. This year's focus was on the development of a system that would accomplish the primary tasks of the rover, to gather and return samples. All the aspects of this complex and challenging task were investigated. In order to achieve a complete system devices were designed for every stage from sample acquisition to processing and final storage.

Source record↗

Research and Development Annual Report, 1992

Issued as a companion to Johnson Space Center's Research and Technology Annual Report, which reports JSC accomplishments under NASA Research and Technology Operating Plan (RTOP) funding, this report describes 42 additional JSC projects that are funded through sources other than the RTOP. Emerging technologies in four major disciplines are summarized: space systems technology, medical and life sciences, mission operations, and computer systems. Although these projects focus on support of human spacecraft design, development, and safety, most have wide civil and commercial applications in areas such as advanced materials, superconductors, advanced semiconductors, digital imaging, high density data storage, high performance computers, optoelectronics, artificial intelligence, robotics and automation, sensors, biotechnology, medical devices and diagnosis, and human factors engineering.

Source record↗

The JSC Research and Development Annual Report 1993

Issued as a companion to Johnson Space Center's Research and Technology Annual Report, which reports JSC accomplishments under NASA Research and Technology Operating Plan (RTOP) funding, this report describes 47 additional projects that are funded through sources other than the RTOP. Emerging technologies in four major disciplines are summarized: space systems technology, medical and life sciences, mission operations, and computer systems. Although these projects focus on support of human spacecraft design, development, and safety, most have wide civil and commercial applications in areas such as advanced materials, superconductors, advanced semiconductors, digital imaging, high density data storage, high performance computers, optoelectronics, artificial intelligence, robotics and automation, sensors, biotechnology, medical devices and diagnosis, and human factors engineering.

Source record↗

Life Sciences Research in the Centrifuge Accommodation Module of the International Space Station

The Centrifuge Accommodation Module (CAM) will be the home of the fundamental biology research facilities on the International Space Station (ISS). These facilities are being built by the Biological Research Project (BRP), whose goal is to oversee development of a wide variety of habitats and host systems to support life sciences research on the ISS. The habitats and host systems are designed to provide life support for a variety of specimens including cells, bacteria, yeast, plants, fish, rodents, eggs (e.g., quail), and insects. Each habitat contains specimen chambers that allow for easy manipulation of specimens and alteration of sample numbers. All habitats are capable of sustaining life support for 90 days and have automated as well as full telescience capabilities for sending habitat parameters data to investigator homesite laboratories. The habitats provide all basic life support capabilities including temperature control, humidity monitoring and control, waste management, food, media and water delivery as well as adjustable lighting. All habitats will have either an internal centrifuge or are fitted to the 2.5-meter diameter centrifuge allowing for variable centrifugation up to 2 g. Specimen chambers are removable so that the specimens can be handled in the life sciences glovebox. Laboratory support equipment is provided for handling the specimens. This includes a compound and dissecting microscope with advanced video imaging, mass measuring devices, refrigerated centrifuge for processing biological samples, pH meter, fixation and complete cryogenic storage capabilities. The research capabilities provided by the fundamental biology facilities will allow for flexibility and efficiency for long term research on the International Space Station.

Dalton, Bonnie P.↗

The electrostatic storage tube

An electrostatic camera system is discussed which is based on the electrostatic storage tube. The development of the system was begun following a series of experiments which indicated that the device offers signficantly improved performance over currently available devices. The approach used in developing the high performance camera involves: converting the input image to an electron image at low loss, applying a low noise gain process, and storing the resulting charge pattern in a low-loss target. The basic processes and elements of the electrostatic storage tube are illustrated and discussed. Graphs that depict the camera performance characteristics are included.

Rutherford, R. E., Jr.↗

Deployable flexible ventral fins for use as an emergency spin recovery device in aircraft

A flexible fin device for mounting on an aircraft to effect spin recovery is described. The device may be selectively deployed to provide a triangular planform of flexible material to provide spin recovery, and retracted for compact storage during non-use. A single flexible fin may be deflected in a specific direction depending on direction of spin rotation, or two flexible fins forming an inverted V configuration may be used. The device is mounted on the underbody of the aircraft.

Burk, S. M., Jr.↗

The silicon vidicon: Integration, storage and slow scan capability - Experimental observation of a secondary mode of operation.

Description of the performance of the silicon diode array vidicon - an imaging sensor which possesses wide spectral response, high quantum efficiency, and linear response. These characteristics, in addition to its inherent ruggedness, simplicity, and long-term stability and operating life make this device potentially of great usefulness for ground-base and spaceborne planetary and stellar imaging applications. However, integration and charged storage for periods greater than approximately five seconds are not possible at room temperature because of diode saturation from dark current buildup. Since dark current can be reduced by cooling, measurements were made in the range from -65 to 25 C. Results are presented on the extension of integration, storage, and slow scan capabilities achievable by cooling. Integration times in excess of 20 minutes were achieved at the lowest temperatures. The measured results are compared with results obtained with other types of sensors and the advantages of the silicon diode array vidicon for imaging applications are discussed.

Ando, K. J.↗

A high resolution semiconductor detector for applications in space

Nuclear radiation detectors with volumes of approximately 1 cu cm was fabricated from single crystals of germanium-silicon alloy containing as much as 20 weight percent germanium. The properties of these detectors were investigated and will be discussed. Tests reveal that the gamma ray photoelectric peak efficiency of an alloy detector with only 12 weight percent germanium is approximately 4 times that of a silicon detector of equal volume. The room temperature roomure appears to be a good possibility. Storage for long periods at room temperature does not seem to adversely affect these devices. The results of preliminary radiation damage experiments suggest that the alloy detectors possess a radiation damage resistance far greater than that of silicon.

Alexander, P.↗

Development of a large pixel, spectrally optimized, pinned photodiode/interline charge coupled device (CCD) detector for the Earth Observing System (EOS)/Moderate-Resolution Imaging Spectrometer-Tilt (MODIS-T) instrument

A pinned photodiode/interline CCD Detector Array is under development for the EOS/MODIS-T project. Outstanding features of the device include large pixels, spectrally optimized fill factors, and blooming protection. The detector has 30 spatial rows and 32 spectral columns. The device layout is split into two halves; each half has its own detector area, storage area, and output structure.

Ewin, Audrey J.↗

Unitized Regenerative Fuel Cell System Development

Unitized Regenerative Fuel Cells (URFC) have recently been developed by several fuel cell manufacturers. These manufacturers have concentrated their efforts on the development of the cell stack technology itself, and have not up to this point devoted much effort to the design and development of the balance of plant. A fuel cell technology program at the Glenn Research Center (GRC) that has as its goal the definition and feasibility testing of the URFC system balance of plant. Besides testing the feasibility, the program also intends to minimize the system weight, volume, and parasitic power as its goal. The design concept currently being developed uses no pumps to circulate coolant or reactants, and minimizes the ancillary components to only the oxygen and hydrogen gas storage tanks, a water storage tank, a loop heat pipe to control the temperature and two pressure control devices to control the cell stack pressures during operation. The information contained in this paper describes the design and operational concepts employed in this concept. The paper also describes the NASA Glenn research program to develop this concept and test its feasibility.

Burke, Kenneth A.↗

Hand-Held Units for Short-Range Wireless Biotelemetry

Special-purpose hand-held radiotransceiver units have been proposed as means of short-range radio powering and interrogation of surgically implanted microelectromechanical sensors and actuators. These units are based partly on the same principles as those of the units described in "Printed Multi- Turn Loop Antennas for RF Biotelemetry" (LEW-17879-1), NASA Tech Briefs, Vol. 31, No. 6 (June 2007), page 48. Like the previously reported units, these units would make it unnecessary to have wire connections between the implanted devices and the external equipment used to activate and interrogate them. Like a unit of the previously reported type, a unit of the type now proposed would include a printed-circuit antenna on a dielectric substrate. The antenna circuitry would include integrated surface-mount inductors for impedance tuning. Circuits for processing the signals transmitted and received by the antenna would be included on the substrate. During operation, the unit would be positioned near (but not in electrical contact with) a human subject, in proximity to a microelectromechanical sensor or actuator that has been surgically implanted in the subject. It has been demonstrated that significant electromagnetic coupling with an implanted device could be established at a distance of as much as 4 in. (.10 cm). During operation in the interrogation mode, the antenna of the unit would receive a radio telemetry signal transmitted by the surgically implanted device. The antenna substrate would have dimensions of approximately 3.25 by 3.75 inches (approximately 8.3 by 9.5 cm). The substrate would have a thickness of the order of 30 mils (of the order of a somewhat less than a millimeter). The substrate would be made of low-radiofrequency- loss dielectric material that could be, for example, fused quartz, alumina, or any of a number of commercially available radio-frequency dielectric composite materials. The antenna conductors would typically be made of copper or a combination of chromium and gold. The choice of metal and the thickness of the metal layer(s) would depend on the choice of substrate material. For example, on a quartz or alumina substrate, one would typically use a layer of chromium 150 A thick and a layer of gold 2 m thick. The proposed units and the implanted devices that they would interrogate or activate would be inherently safe to use. They would operate at low radiated-power levels for short interrogation times (typically, milliseconds). Hence, there would be little local heating of tissues surrounding the implanted devices and little absorption of radio energy by such sensitive body parts as the eyes and the brain. Because the implanted devices would not depend on battery power and would be activated only during short interrogation intervals and would otherwise be in the goff h state most of the time, the useful lifetimes of the implanted devices would be greater than those of comparable battery-powered implanted devices. The compactness of the hand-held transceiver units would facilitate transport and storage and would facilitate self-diagnosis by patients able to handle the units while away from medical facilities.

Miranda, Felix A.↗

Method of Separating Oxygen From Spacecraft Cabin Air to Enable Extravehicular Activities

Extravehicular activities (EVAs) require high-pressure, high-purity oxygen. Shuttle EVAs use oxygen that is stored and transported as a cryogenic fluid. EVAs on the International Space Station (ISS) presently use the Shuttle cryo O2, which is transported to the ISS using a transfer hose. The fluid is compressed to elevated pressures and stored as a high-pressure gas. With the retirement of the shuttle, NASA has been searching for ways to deliver oxygen to fill the highpressure oxygen tanks on the ISS. A method was developed using low-pressure oxygen generated onboard the ISS and released into ISS cabin air, filtering the oxygen from ISS cabin air using a pressure swing absorber to generate a low-pressure (high-purity) oxygen stream, compressing the oxygen with a mechanical compressor, and transferring the high-pressure, high-purity oxygen to ISS storage tanks. The pressure swing absorber (PSA) can be either a two-stage device, or a single-stage device, depending on the type of sorbent used. The key is to produce a stream with oxygen purity greater than 99.5 percent. The separator can be a PSA device, or a VPSA device (that uses both vacuum and pressure for the gas separation). The compressor is a multi-stage mechanical compressor. If the gas flow rates are on the order of 5 to 10 lb (.2.3 to 4.6 kg) per day, the compressor can be relatively small [3 ~16 ~16 in. (.8 ~41 ~41 cm)]. Any spacecraft system, or other remote location that has a supply of lowpressure oxygen, a method of separating oxygen from cabin air, and a method of compressing the enriched oxygen stream, has the possibility of having a regenerable supply of highpressure, high-purity oxygen that is compact, simple, and safe. If cabin air is modified so there is very little argon, the separator can be smaller, simpler, and use less power.

Graf, John C.↗