Search NASA⌕ Search

SEARCH · Search NASA

Results for “SYSTEM MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

The Human as a System - Monitoring Spacecraft Net Habitable Volume throughout the Design Lifecycle

Spacecraft design has historically allocated specific volume and mass "not to exceed" requirements upon individual systems and their accompanying hardware (e.g., life support, avionics) early in their conceptual design in an effort to align the spacecraft with propulsion capabilities. If the spacecraft is too heavy or too wide for the launch stack - it does not get off the ground. This approach has predictably ended with the crew being allocated whatever open, pressurized volume remains. With the recent inauguration of a new human-rated spacecraft - NASA human factors personnel have found themselves in the unique position to redefine the human as a system from the very foundation of design. They seek to develop and monitor a "not to fall below" requirement for crew net habitable volume (NHV) - balanced against the "not to exceed" system volume requirements, with the spacecraft fitting the crew versus the crew having to fit inside the spacecraft.

Szabo, Richard↗

Wireless battery management control and monitoring system

A battery management system using a sensor inside of the battery that sensor enables monitoring and detection of various events in the battery and transmission of a signal from the sensor through the battery casing to a control and data acquisition module by wireless transmission. The detection of threshold events in the battery enables remedial action to be taken to avoid catastrophic events.

25 ENERGY STORAGE↗

An introduction to orbit dynamics and its application to satellite-based earth monitoring systems

The long term behavior of satellites is studied at a level of complexity suitable for the initial planning phases of earth monitoring missions. First-order perturbation theory is used to describe in detail the basic orbit dynamics of satellite motion around the earth and relative to the sun. Surface coverage capabilities of satellite orbits are examined. Several examples of simulated observation and monitoring missions are given to illustrate representative applications of the theory. The examples stress the need for devising ways of maximizing total mission output in order to make the best possible use of the resultant data base as input to those large-scale, long-term earth monitoring activities which can best justify the use of satellite systems.

Brooks, D. R.↗

Vehicle Radiation Monitoring Systems for Medical Waste Disposal - 12102

Hospitals often declare their waste as being 'non-radioactive'; however this material often has excessive levels of radiation caused either by an accident or lack of control. To ensure the best possible protection against the accidental receipt of radioactive materials and as a safety precaution for their employees, waste-handling companies have installed large-scale radiation portal monitors at their weigh scales or entry gates of the incinerator plant, waste transfer station, and/or landfill. Large-volume plastic scintillator-based systems can be used to monitor radiation levels at entry points to companies handling medical waste. The recent and intensive field tests together with the thousands of accumulated hours of actual real-life vehicle scanning have proven that the plastic scintillation based system is an appropriate radiation control instrument for waste management companies. The Real-Time background compensation algorithm is flexible with automatic adjustable coefficients that will response to rapidly changing environmental and weather conditions maintaining the preset alarm threshold levels. The Dose Rate correction algorithms further enhance the system's ability to meet the stringent requirements of the waste industries need for Dose Rate measurements. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Microsensor Technologies for Plant Growth System Monitoring

This document covered the following: a) demonstration of feasibility of microsensor for tube and particulate growth systems; b) Dissolved oxygen; c)Wetness; d) Flexible microfluidic substrate with microfluidic channels and microsensor arrays; e)Dynamic root zone control/monitoring in microgravity; f)Rapid prototyping of phytoremediation; and g) A new tool for root physiology and pathology.

Kim, Chang-Soo↗

Cavity Beam Position Monitor System for ATF2

The Accelerator Test Facility 2 (ATF2) in KEK, Japan, is a prototype scaled demonstrator system for the final focus required for a future high energy lepton linear collider. The ATF2 beam-line is instrumented with a total of 38 C and S band resonant cavity beam position monitors (CBPM) with associated mixer electronics and digitizers. The current status of the BPM system is described, with a focus on operational techniques and performance. The ATF2 C-band system is performing well, with individual CBPM resolution approaching or at the design resolution of 50 nm. The changes in the CBPM calibration observed over three weeks can probably be attributed to thermal effects on the mixer electronics systems. The CW calibration tone power will be upgraded to monitor changes in the electronics gain and phase. The four S-band CBPMs are still to be investigated, the main problem associated with these cavities is a large cross coupling between the x and y ports. This combined with the large design dispersion in that degion makes the digital signal processing difficult, although various techniques exist to determine the cavity parameters and use these coupled signals for beam position determination.

43 PARTICLE ACCELERATORS↗

A Greenhouse-Gas Information System - Monitoring and Validating Emissions Reporting and Mitigation - Chapter 2: Requirements Framework

The present study on a proposed greenhouse-gas information system (GHGIS) was undertaken without the benefit of requirements and specifications that will ultimately drive its choices and architecture. The discussion in this chapter attempts to develop a requirements framework that can be relied on to make choices between desired accuracy, precision, and confidence, vs. cost, schedule, and other elements. The accuracy or precision of the GHGIS (top-down) components required to validate reporting and international commitments depends on factors determined by the nature of the commitments as well as the goals of the users. The present study focuses on the task of measuring GHG emissions and attributing anthropogenic surface fluxes. This chapter explores possible emissions pathways that depart from targets and makes a number of assumptions about the needs of users to detect and quantify such departures, regardless of whether they are the result of inadvertent or willful reporting errors. Such user needs would be used to set GHGIS requirements.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

COMMON – Communications System Monitor v. 1.5

COMMON is a tool for collecting, storing, and displaying critical information to facilitate analysis on Microsoft Windows based IT systems. COMMON was developed to provide insight into the IT infrastructure for operational radiation detection systems, but is applicable to most Windows-based operating systems and TCP/IP network components. The COMMON tool aggregates a host of important Windows Management Instrumentation (WMI) information and as well as network ping responses to provide valuable insight into the performance of the IT system. A unique feature is the creation of daily output files (JSON) from the data collected for off site evaluation by subject matter experts.

Aragon, MonaL↗

Smart Composite Overwrapped Pressure Vessel - Integrated Structural Health Monitoring System to Meet Space Exploration and International Space Station Mission Assurance Needs

Currently there are no integrated NDE methods for baselining and monitoring defect levels in fleet for Composite Overwrapped Pressure Vessels (COPVs) or related fracture critical composites, or for performing life-cycle maintenance inspections either in a traditional remove-and-inspect mode or in a more modern in situ inspection structural health monitoring (SHM) mode. Implicit in SHM and autonomous inspection is the existence of quantitative accept-reject criteria. To be effective, these criteria must correlate with levels of damage known to cause composite failure. Furthermore, implicit in SHM is the existence of effective remote sensing hardware and automated techniques and algorithms for interpretation of SHM data. SHM of facture critical composite structures, especially high pressure COPVs, is critical to the success of nearly every future NASA space exploration program as well as life extension of the International Space Station. It has been clearly stated that future NASA missions may not be successful without SHM [1]. Otherwise, crews will be busy addressing subsystem health issues and not focusing on the real NASA mission

Saulsberry, Regor↗

Simulator evaluation of takeoff performance monitoring system displays

The development of head-up and head-down cockpit displays to convey symbolic status and advisory information to the pilot to aid him in his decision to continue or abort takeoff is described. It also describes a pilot-in-the-loop evaluation of the displays using the NASA Langley transport systems research vehicle fixed-base simulator. It was found that the head-up display was monitored with little effort and did not obstruct or distract from the runway scene.

Middleton, David B.↗

Field Trial of a Low-Cost, Distributed Plug Load Monitoring System

Researchers have struggled to inventory and characterize the energy use profiles of the ever-growing category of so-called miscellaneous electric loads (MELs) because plug-load monitoring is cost-prohibitive to the researcher and intrusive to the homeowner. However, these data represent a crucial missing link to understanding how homes use energy. Detailed energy use profiles would enable the nascent automated home energy management (AHEM) industry to develop effective control algorithms that target consumer electronics and other plug loads. If utility and other efficiency programs are to incent AHEM devices, they need large-scale datasets that provide statistically meaningful justification of their investments by quantifying the aggregate energy savings achievable. To address this need, NREL researchers investigated a variety of plug-load measuring devices available commercially and tested them in the laboratory to identify the most promising candidates for field applications. This report centers around the lessons learned from a field validation of one proof-of-concept system, called Smartenit (formerly SimpleHomeNet). The system was evaluated based on the rate of successful data queries, reliability over a period of days to weeks, and accuracy. This system offers good overall performance when deployed with up to 10 end nodes in a residential environment, although deployment with more nodes and in a commercial environment is much less robust. NREL concludes that the current system is useful in selected field research projects, with the recommendation that system behavior is observed over time.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Chemo-thermo-piezoresistive highly sensing smart cement with integrated real-time monitoring system

The chemo-thermo-piezoresistive behavior of so-called “smart cement,” or cement modified with conductive fillers, is useful as a bulk sensor for monitoring the changes in the cement due to stresses, cracks, contamination, fluid loss, and temperature change that affect its performance. The smart cement utilizes a special conductive or semi-conductive filler and is useful as a bulk sensor that allows real-time monitoring of its properties.

Vipulanandan, Cumaraswamy↗

Field Trial of a Low-Cost, Distributed Plug Load Monitoring System

Researchers have struggled to inventory and characterize the energy use profiles of the ever-growing category of so-called miscellaneous electric loads (MELs) because plug-load monitoring is cost-prohibitive to the researcher and intrusive to the homeowner. However, these data represent a crucial missing link to our understanding of how homes use energy, and we cannot control what we do not understand. Detailed energy use profiles would enable the nascent automated home energy management (AHEM) industry to develop effective control algorithms that target consumer electronics and other plug loads. If utility and other efficiency programs are to incent AHEM devices, they need large-scale datasets that provide statistically meaningful justification of their investments by quantifying the aggregate energy savings achievable. To address this need, we have investigated a variety of plug-load measuring devices available commercially and tested them in the laboratory to identify the most promising candidates for field applications. The scope of this report centers around the lessons learned from a field validation of one proof-of-concept system, called Smartenit (formerly SimpleHomeNet). The system was evaluated based on the rate of successful data queries, reliability over a period of days to weeks, and accuracy. This system offers good overall performance when deployed with up to ten end nodes in a residential environment, although deployment with more nodes and in a commercial environment is much less robust. We conclude that the current system is useful in selected field research projects, with the recommendation that system behavior is observed over time.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗