Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sample Collection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Sources and Variability of Nitrate on an Alaskan Hillslope Dominated by Alder Shrubs, Kougarok, Alaska, 2017 and 2018

Data provided include results of analyses of soil pore-water, soil moisture, and leaf litter samples collected at a Kougarok Hillslope site dominated by alder shrubs (KG_MM64) in the Seward Peninsula, Alaska during July and September 2017 and 2018. Samples were from surface soils in close proximity to 5 alder patches, collected upslope, within, and downslope of the alder patches. Pore water was analyzed for a comprehensive set of anions, cations, elemental analyses, and oxygen and nitrogen isotopes. Soil samples were collected for soil moisture determination. Leaf litter extracts were analyzed for carbon and nitrogen content and carbon and nitrogen isotopes. This dataset contains 3 *.csv files and 1 *.pdf file. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Phosphorus and cover crop management practices affect phosphorus speciation in soils and eroded sediments

Abstract Agricultural runoff often contains P in dissolved and sediment‐bound forms, decreasing surface water quality. No‐till and cover cropping conservation practices have been recommended for reducing erosion and nutrient loss from cropping systems. The overall aims of this study were to characterize and evaluate the effects of fertilizer (placement and source) and cover crop management on P speciation in surface runoff sediments and source soil. In 2014, a field‐scale experiment was established in a no‐till, corn (Zea maysL.)–soybean (Glycine maxL.) cropping system with two cover crop treatments (with and without a winter crop; winter wheat [Triticum aestivumL.], rapeseed [Brassica napusL.], hairy vetch [Vicia villosaRoth], winter triticale [×Triticosecale Wittm.], and cereal rye [Secale cerealeL.]) and three P fertilizer management treatments (no P, fall broadcast diammonium phosphate, and spring subsurface injected ammonium polyphosphate). Phosphorus fractionation in the source soil collected in the fall of 2019 and sediment samples collected throughout 2020 were analyzed using a modified sequential P extraction method to evaluate the cumulative effects of imposing the treatment factors over 5 years. The direct P speciation was done using X‐ray absorption near edge structure spectroscopy. The indirect P speciation (fractionation) results showed that the management practices affected the exchangeable, organic matter‐associated, and Fe‐bound P fractions in sediments and the exchangeable and residual fractions in source soil. Direct P speciation results showed a depletion of Fe‐associated P in soil and sediment from cover crop treatment, suggesting that Fe‐associated P species were affected by cover crops. Changes in soil and runoff sediment P speciation would change the proportions and forms of soluble and particulate P in runoff sediments and may influence P bioavailability in aquatic ecosystems. Developing P fertilizer and cropping system management options with an understanding of soil P transformations helps maintain environmental sustainability.

Environmental Sciences & Ecology↗

Combustion water purification techniques influence on OBT analysing using liquid scintillation counting method

In order to determine organically bound tritium (OBT) from environmental samples, these must be converted into water, measurable by liquid scintillation counting (LSC). For this purpose we conducted some experiments to determine OBT level of a grass sample collected from an uncontaminated area. The studied grass sample was combusted in a Parr bomb. However usual interfering phenomena were identified: color or chemical quench, chemiluminescence, overlap over tritium spectrum because of other radionuclides presence as impurities ({sup 14}C from organically compounds, {sup 36}Cl as chloride and free chlorine, {sup 40}K as potassium cations) and emulsion separation. So the purification of the combustion water before scintillation counting appeared to be essential. 5 purification methods were tested: distillation with chemical treatment (Na{sub 2}O{sub 2} and KMnO{sub 4}), lyophilization, chemical treatment (Na{sub 2}O{sub 2} and KMnO{sub 4}) followed by lyophilization, azeotropic distillation with toluene and treatment with a volcanic tuff followed by lyophilization. After the purification step each sample was measured and the OBT measured concentration, together with physico-chemical analysis of the water analyzed, revealed that the most efficient method applied for purification of the combustion water was the method using chemical treatment followed by lyophilization.

54 ENVIRONMENTAL SCIENCES↗

Annual Report of Monitoring at Morrill, Kansas, in 2011

Carbon tetrachloride contamination in groundwater at Morrill, Kansas, was initially identified in 1985 during statewide testing of public water supply wells for volatile organic compounds (VOCs). High levels of nitrate were also present in the wells. The city of Morrill is located in Brown County in the northeastern corner of the state, about 7 mi east of Sabetha (Figure 1.1). The population of Morrill as of the 2010 Census was approximately 230 (down from 277 in 2000). All residents of Morrill now obtain their drinking water from the Sabetha municipal water system via a pipeline constructed in 1991. The findings of the April 2011 and October 2011 monitoring events at Morrill support the following conclusions: (1) Groundwater flow during the 2011 review period (as in prior years) was predominantly to the south, from the vicinity of the former CCC/USDA facility toward Terrapin Creek. Automatic water level monitoring data suggest that spring precipitation and recharge represent the predominant factors affecting the local groundwater level patterns. (2) No significant changes were observed in the concentration or distribution of carbon tetrachloride in groundwater during the spring and fall 2011 monitoring events versus the spring and fall 2010 monitoring events. In October 2011, a maximum carbon tetrachloride concentration of 49 μg/L was identified in groundwater at well MW3S on the former CCC/USDA facility, with concentrations decreasing downgradient toward Terrapin Creek. (3) Since 2004, the accumulated results of 15 sampling events have demonstrated a significant decline in the maximum detected concentration of carbon tetrachloride in groundwater. In 1995, the contaminant was detected at the former CCC/USDA facility at 390 μg/L, while the current maximum levels are < 50 μg/L. The residual contaminant plume extending from the former CCC/USDA facility southward toward Terrapin Creek is well-defined and slowly declining in concentration naturally. (4) No carbon tetrachloride contamination was detected in 2011 in surface waters or shallow streambed sediments sampled at five locations along Terrapin Creek, downgradient from the former CCC/USDA facility. These results indicate that Terrapin Creek remains unaffected by the carbon tetrachloride plume. (5) Since 2007, the accumulated results of 10 monitoring events for surface water and sediment in Terrapin Creek have demonstrated no impact to the sediment and surface waters of the creek by carbon tetrachloride and no imminent risk for further degradation of the creek. (6) Terrapin Creek (tributary segment 308 to Walnut Creek) receives discharge from the Morrill wastewater treatment plant and several confined animal feeding operations regulated by the KDHE. The Walnut Creek watershed is designated by the KDHE as impaired by fecal coliform bacteria. Terrapin Creek is classified by the KDHE as not open to or accessible by the public for contact recreation and does not support the food procurement designated use (KDHE 2010b). (7) In July 2011, trace concentrations of carbon tetrachloride were detected in vegetation samples collected from trees at 2 of the 42 sampled locations south (downgradient) of the former CCC/USDA facility. (8) Sampling of indoor air in August 2010 to evaluate the potential for vapor intrusion into homes overlying and within 100 ft laterally of the identified carbon tetrachloride plume resulted in no detections of carbon tetrachloride. Low concentrations of chloroform, indicative of indoor air sources, were detected. Low radon levels were also detected. The results indicate no evidence of upward migration of vapors from the low-level carbon tetrachloride contamination in groundwater to indoor air.

54 ENVIRONMENTAL SCIENCES↗

Completion Report for Well ER-2-2 Corrective Action Unit 97: Yucca Flat/Climax Mine

Well ER-2-2 was drilled for the U.S. Department of Energy, Nevada National Security Administration Nevada Field Office in support of the Underground Test Area (UGTA) Activity. The well was drilled from January 17 to February 8, 2016, as part of the Corrective Action Investigation Plan (CAIP) for Corrective Action Unit 97: Yucca Flat/Climax Mine, Nevada Test Site, Nevada. The primary purpose of the well was to collect hydrogeologic data to evaluate uncertainty in the flow and transport conceptual model and its contamination boundary forecasts, and to detect radionuclides in groundwater from the CALABASH (U2av) underground test. Well ER-2-2 was not completed as planned due to borehole stability problems. As completed, the well includes a piezometer (p1) to 582 meters (m) (1,909 feet [ft]) below ground surface (bgs) installed in the Timber Mountain lower vitric-tuff aquifer (TMLVTA) and a 12.25-inch (in.) diameter open borehole to 836 m (2,743 ft) bgs in the Lower tuff confining unit (LTCU). A 13.375-in. diameter carbon-steel casing is installed from the surface to a depth of 607 m (1,990 ft) bgs. Data collected during borehole construction include composite drill cutting samples collected every 3.0 m (10 ft), geophysical logs to a depth of 672.4 m (2,206 ft) bgs, water-quality measurements (including tritium), water-level measurements, and slug test data. The well penetrated 384.05 m (1,260 ft) of Quaternary alluvium, 541.93 m (1,778 ft) of Tertiary Volcanics (Tv) rocks, and 127.71 m (419 ft) of Paleozoic carbonates. The stratigraphy and lithology were generally as expected. However, several of the stratigraphic units were significantly thicker then predicted—principally, the Tunnel formation (Tn), which had been predicted to be 30 m (100 ft) thick; the actual thickness of this unit was 268.22 m (880 ft). Fluid depths were measured in the borehole during drilling as follows: (1) in the piezometer (p1) at 552.15 m (1,811.53 ft) bgs and (2) in the main casing (m1) at 551.69 m (1,810.01 ft) bgs. As expected, field measurements for tritium were above the Safe Drinking Water Act limit (20,000 picocuries per liter). All Fluid Management Plan requirements were met.

54 ENVIRONMENTAL SCIENCES↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on a Hanford AP Tank Farm Exhauster Slipstream (Volume 1)

Washington River Protection Solutions (WRPS) tested four types of chemical cartridges for use in air-purifying respirators (APR) and powered air-purifying respirators (PAPR). These tests were undertaken to determine the period of time that the cartridges would provide adequate performance1 for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the Hanford AP tank farm exhauster slipstream. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing cartridge change schedules. Testing commonly is applied in situations where mixtures of COPCs exist and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Cartridge testing on a slipstream from the Hanford AP tank exhauster was conducted on March 23-24, 2018. This testing focused on both APR and PAPR cartridges. Previous testing of APR cartridges was conducted on the AP exhauster in June of 2016. However, an AP exhauster upgrade was completed in September 2016. In the most recent testing, slipstream vapors from the new AP exhauster were fed to two respirator cartridge test stands, one for the PAPR respirator cartridges and the other for the APR respirator cartridges. Both the APR and PAPR test stands were developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose APR cartridges—SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina)—were assessed on separate days using the APR cartridge test stand. Multipurpose PAPR cartridges—MSA OptiFilter TL (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR-57 (3M Company, Maplewood, Minnesota)—were also tested consecutively over the same two days as the APR cartridge tests, using the PAPR cartridge test stand. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges, and the samples then were analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

61 RADIATION PROTECTION AND DOSIMETRY↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on Hanford Tanks BY-108 and BY-110 Volume 1

Washington River Protection Solutions (WRPS) tested four types of chemical cartridges for use in air-purifying respirators (APR) and powered air-purifying respirators (PAPR). These tests were undertaken to determine the period of time that the cartridges would provide adequate performance for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the headspaces of Hanford BY-108 and BY-110 waste storage tanks. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing cartridge change schedules. Testing commonly is applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Cartridge tests were conducted over two days from February 23-25, 2018, using headspace vapors from Hanford tanks BY-108 and BY-110. Headspace vapors from the BY-108 tank were fed to the PAPR respirator cartridge test stand, while vapors from the BY-110 headspace were fed to the APR respirator cartridge test stand. Both the APR and PAPR test stands were developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Two different cartridges were assessed on each tank. Multipurpose APR cartridges—SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina)—were assessed for vapors from BY-110 using the APR cartridge test stand. Multipurpose PAPR cartridges—MSA OptiFilter TL (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR-57 (3M Company, Maplewood, Minnesota)—also were assessed for vapors from BY-108 over the same two days using the PAPR cartridge test stand. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges, and the samples then were analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on a Hanford AX Tank Farm Exhauster Slipstream Volume 1

Washington River Protection Solutions (WRPS) conducted tests of four types of chemical cartridges for air-purifying respirators (APR) and powered air-purifying respirators (PAPR) to determine the period of time the cartridges would provide adequate performance1 for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors exiting the Hanford AX tank farm exhauster slipstream. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing a cartridge service life. Testing is applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Cartridge testing using vapors from a Hanford AX tank farm exhauster slipstream was conducted from August 25–27, 2017. Vapors from the exhauster slipstream were fed to two respirator cartridge test stands developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Four different cartridges were assessed. Multipurpose APR cartridges—SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina)—were assessed on separate days using an APR cartridge test stand. Multipurpose PAPR cartridges—MSA-TL (TL1) (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR57 (TL2) (3M Company, Maplewood, Minnesota)—also were tested over the same two days using a separate PAPR cartridge test stand. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on Hanford Tanks SX-101 and SX-104 Volume 1

Washington River Protection Solutions (WRPS) conducted tests using two types of chemical cartridges for use in powered air-purifying respirators (PAPR) to determine the period of time that the cartridges would provide adequate performance for PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors exiting the headspaces of Hanford tanks SX-101 and SX-104. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing cartridge change schedules. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from June 16-17, 2017, from headspace vapors from Hanford tank SX-101 and from June 23-24, 2017, from Hanford tank SX-104. Headspace vapors were fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose high-efficiency PAPR cartridges, MSA-TL (TL1) (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR-57 (TL2) (3M Company, Maplewood, Minnesota) were assessed on separate days. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Defining Lipidomic Responses to Coronavirus Infection

Highly pathogenic human coronavirus infection can cause a severe atypical, rapid onset pneumonia with a mortality rate of up to 10% for severe acute respiratory syndrome coronavirus 1 (SARS-CoV 1), 35% for Middle East respiratory syndrome coronavirus (MERS-CoV), or 1% for severe acute respiratory syndrome coronavirus 2 (SARS-CoV 2 causative agent of COVID 19). While medical countermeasures successfully controlled the worldwide SARS-CoV epidemic, the MERS-CoV epidemic is still ongoing and continues to be a concern for travelers in the Middle East and the multi-year SARS-CoV 2 pandemic underscore the importance of defining biomarkers that are diagnostic and/or predictive of severe disease outcomes for respiratory viruses. Systems biology approaches provide global snapshots of infection induced changes in host cells/tissues and provide extremely rich datasets for understanding host pathogen interactions. Metabolites, especially lipids, are critical for viral replication but less is understood about infection induced changes to lipids due to limits in lipid species detection and identification. To characterize how individual lipid species and proteins with lipid associated functions contribute to highly pathogenic human coronavirus replication and disease severity, existing datasets were probed to determine cell type specific lipid responses to MERS-CoV infection and verification studies were performed to determine if modification of the host lipid signature (by inhibiting enzymatic functions that produce specific lipid species) can perturb CoV replication in human lung cells. MERS-CoV infects human lung epithelial, endothelial and fibroblast cells. All three cell types were infected with MERS-CoV and samples collected to analyze lipids, proteins, metabolites, and transcripts from 12 to 48 hours post infection. Time matched mock-infected cells were collected in parallel for each cell type. Following sample and statistical analysis, functional enrichment and bioinformatic analysis was performed to identify differentially expressed lipids and proteins. Two lipid species were found to be significantly upregulated following MERS-CoV infection, ceramides, and triacylglycerol both of which are indicative of cells undergoing apoptotic cell death. In contrast, sphingomyelins (lipid molecules that can serve as a precursor for one pathway for ceramide synthesis) had significantly decreased expression in MERS-CoV infected cells. An inhibitor of acid sphingomyelinase (that converts sphingomyelin to ceramides and phosphorylcholine) reduced MERS-CoV replication suggesting that production of ceramides is key for successful viral replication and transmission. Acyl-CoA-synthetase 3 (ACSL3), the only protein whose function is lipid associated and had increased differential expression in our dataset, regulates the synthesis of triacylglycerol (increased expression). Inhibitors that directly block ACSL3 (Triacsin C) but not steps later in the triacylglycerol synthesis pathway (Etomoxir) inhibit MERS-CoV replication suggesting that triacylglycerol production and/or ACSL3 activity is also key for viral replication. ACSL3 expression is also upregulated in lung cancer cells and is predicted to promote continued cell viability which would also enhance viral replication. The differentially expressed lipid and lipid-associated protein species identified in our studies suggest that MERS-CoV infection is activating cellular death pathways to limit the number of cells that become infected but also stimulating the production of lipid-associated enzymes that can prolong host cell viability and the amount of time progeny virions can be produced and released. As the inhibitors that worked against MERS-CoV infection were also efficacious against SARS-CoV 2 infection, countermeasures that target these host pathways may provide novel ways to block highly pathogenic human coronavirus infection and/or prevent severe disease outcomes.

59 BASIC BIOLOGICAL SCIENCES↗

In-Situ XRF Measurements in Lunar Surface Exploration Using Apollo Samples as a Standard

Samples collected during the Apollo lunar surface missions were sampled and returned to Earth by astronauts with varying degrees of geological experience. The technology used in these EVAs, or extravehicular activities, included nothing more advanced than traditional terrestrial field instruments: rock hammer, scoop, claw tool, and sample bags. 40 years after Apollo, technology is being developed that will allow for a high-resolution geochemical map to be created in the field real-time. Handheld x-ray fluorescence (XRF) technology is one such technology. We use handheld XRF to enable a broad in-situ characterization of a geologic site of interest based on fairly rapid techniques that can be implemented by either an astronaut or a robotic explorer. The handheld XRF instrument we used for this study was the Innov-X Systems Delta XRF spectrometer.

Young, Kelsey E.↗

Curation and Analysis of Samples from Comet Wild-2 Returned by NASA's Stardust Mission

The NASA Stardust mission returned the first direct samples of a cometary coma from comet 81P/Wild‐2 in 2006. Intact capture of samples encountered at 6 km/s was enabled by the use of aerogel, an ultralow dense silica polymer. Approximately 1000 particles were captured, with micron and submicron materials distributed along ~mm scale length tracks. This sample collection method and the fine scale of the samples posed new challenges to the curation and cosmochemistry communities. Sample curation involved extensive, detailed photo‐documentation and delicate micro‐surgery to remove particles without loss from the aerogel tracks. This work had to be performed in highly clean facility to minimize the potential of contamination. JSC Curation provided samples ranging from entire tracks to micrometer‐sized particles to external investigators. From the analysis perspective, distinguishing cometary materials from aerogel and identifying the potential alteration from the capture process were essential. Here, transmission electron microscopy (TEM) proved to be the key technique that would make this possible. Based on TEM work by ourselves and others, a variety of surprising findings were reported, such as the observation of high temperature phases resembling those found in meteorites, rarely intact presolar grains and scarce organic grains and submicrometer silicates. An important lesson from this experience is that curation and analysis teams must work closely together to understand the requirements and challenges of each task. The Stardust Mission also has laid important foundation to future sample returns including OSIRIS‐REx and Hayabusa II and future cometary nucleus sample return missions.

Nakamura-Messenger, Keiko↗

Chronology of Accessory Phases in Lunar Meteorite Northwest Africa 12593

Lunar meteorites are complementary to the suite of rock and regolith samples collected by the Apollo missions. While the Apollo samples represent the most pristine material we have from the Moon, lunar meteorites represent a more global sampling of the lunar crust, albeit without geologic context [e.g. 1]. As such, lunar meteorites are important for understanding the composition of the lunar crust and the processes responsible for its formation and evolution. This work aims to understand the observed differences in accessory phase chronology and volatile chemistry between lunar meteorites and Apollo rocks. For example, apatite ages in Apollo samples range from ~3.83 to 4.28 Ga [e.g. 2, 3], while apatites in lunar meteorites range from ~3.00 to 4.44 Ga [e.g. 4, 5]. Additionally, a much larger range of Cl isotope compositions and concentrations is observed in lunar meteorites as compared to Apollo samples[e.g. 6]. It has recently been shown that impact metamorphism can influence both chronology and chemistry of phosphates [e.g. 7, 8]. Here we present the first chronologic results from a consortium study pairing chronology, volatile chemistry, and crystal structure of apatites in a lunar breccia meteorite. The results of this work will help inform interpretation of ongoing analyses of apatites separated from Apollo soils. Note: Extended abstract on document.

C. A. Crow↗

Numerical Modelling of Sublimation Losses During Sample Handling Within the Light WAVE Lunar Water Prospecting Instrument

NASA’s focus of exploring the Moon’s south pole under the Artemis program has placed new emphasis on characterizing the quantity and distribution of water ice and other volatiles present within the Moon’s permanently shadowed regions (PSRs), first measured during the 2009 LCROSS mission. NASA’s VIPER rover is the first of a series of prospecting missions to characterize this water ice resource. NASA’s Johnson Space Center (JSC) has developed the Light Water Analysis and Volatiles Extraction (Light WAVE) instrument shown in Figure 1 for a follow-on prospecting mission, designed to be a rover payload for water ice prospecting at various depths and locations within PSRs. A key source of error for lunar water prospecting instruments, including Light WAVE, is the loss of water in an icy regolith sample to the lunar vacuum via sublimation due to heating above its ice-stable temperature. This abstract and conference presentation discuss a sublimation model for Light WAVE’s sample crucible using COMSOL Multiphysics to assess the sublimation losses that would occur between sample collection from an external drill and sealing the sample within Light WAVE’s boiler.

Lunar Polar Water↗

Improved Aerothermal Reliability Analysis Enabled by the Mars Sample Return Earth Entry System Aerothermal Database

The Mars Sample Return (MSR) campaign is a series of missions designed to retrieve Martian rock and soil samples for detailed study on Earth. The campaign is split into three primary phases: sample collection with the Mars2020 rover, retrieval with the Sample Return Lander (SRL) and Mars Ascent Vehicle (MAV), and then return to Earth with the Earth Return Orbiter (ERO) and Capture, Containment, and Return System (CCRS) [1]. The final sequence in the Earth return phase is the delivery and entry of the Earth Entry System (EES) sample return capsule. Due to unprecedented planetary protection concerns, the sample return capsule is subject to strict reliability requirements. To this end, the MSR-EES aerothermal team has implemented a flexible aerothermal database architecture capable of integration with state-of-the-art trajectory codes to provide a more rigorous aerothermal reliability analysis. The EES database enables the generation of environments at any location on the heatshield and can incorporate trajectory uncertainties to both statistically quantify aerothermal environments for arcjet testing and produce material response boundary conditions to rigorously select thermal protection system (TPS) sizing environments. This poster will not discuss the fundamental modeling assumptions included in the database, and will instead focus on the downstream reliability analyses that can be performed with a database of this architecture.

MSR-EES↗

In-Situ Laboratory for nuclear characterization on D and D sites

The nuclear measurement is use in many phases of dismantling and cleanup site. Particularly the results of radiologic characterization are used to create or to optimize the deconstruction scenarios of nuclear plants and to reduce the nuclear waste volume. This type of analyses is made on samples collected in concerned installations. To realize those analyses, samples are send in laboratory what has a great impact on the planning and cost of dismantling. That's the reason why MSIS Assistance (AREVA D and S) devises Mobile Laboratory, which permits to realize nuclear measurement in situ. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗