Search NASA⌕ Search

SEARCH · Search NASA

Results for “Signal generators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Phase Detector For Rectangular Waveforms

Phase detector for use with phase-locked-loops, servocontrol, and other electronic circuits designed to avoid disadvantages of other phase detectors. Used with both intermittent and continuous input signals. Circuit offers several advantages; reference signals continuous, burst of few pulses, or single pulse. Circuit "coasts" in absence of reference signal. Generates no steady-state output waveform at lock which makes filtering easier.

Dischert, Robert A.↗

A study of subterahertz HEMT monolithic oscillators

A detailed study of monolithic InP-based HEMT oscillators for subterahertz operation is presented. InAlAs/InGaAs HEMT's have been optimized for high frequency operation and showed very high maximum oscillation frequencies (f(sub max)) of 310 GHz using offset self-aligned gamma-gate technology. Power characteristics of HEMT oscillators are reported. An oscillation power of more than 10 mW was evaluated by large-signal analysis at 320 GHz using HEMT's with f(sub max) = 450 GHz, V(sub br) = 10 V and a gate width (W(sub g)) of 8 x 22.5 microns. Oscillator topology studies showed that complex feedback schemes such as dual and active feedback enhance the negative resistance. Push-push oscillator designs based on harmonic signal generation can finally be used to overcome the frequency barrier imposed by f(sub max).

Kwon, Youngwoo↗

Observation of mesoscale ocean features in the northeast Pacific using Geosat radar altimetry data

Mesoscale circulation in the Gulf of Alaska is studied by means of processed Geosat radar altimetry results with comparisons to observations of mesoscale eddies and surface circulation. The first set of Geosat data is treated by sea-surface height (SSH) binning in 1-deg latitude x 2-deg longitude boxes and analyzed by complex empirical orthogonal functions and 2D spectral analysis. The second set is taken from ascending Geosat tracks and analyzed as a time series. The Geosat data are compared to observational data including mesoscale eddies and fluctuations in mean surface circulation as well as sea-surface signals generated by numerical models. The data demonstrate the feasibility of a westward propagation of sea-level anomalies, and the Geosat SSH data are found to agree well with model solutions of seasonal variations in sea level in the northeast Pacific.

Matthews, Paul E.↗

H Ly-alpha transmittance of thin foils of C, Si/C, and Al/C for keV particle detectors

A class of instruments designed for remote sensing of space plasmas by measuring energetic neutral atoms (ENA) uses a thin foil as both a signal generator and a light shield. An ENA imager must look directly at the ENA source region, which is also usually an intense source of H Ly-alpha (1216 A) photons. It is desirable to minimize the energy threshold for ENA detectors, at the same time maximizing the blocking of H Ly-alpha. Optimizing filter design to meet these two contrary requirements has led us to measure the transmittance of thin C, Si/C, and Al/C foils at H Ly-alpha. Our results indicate that (1) transmittance of less than 0.0007 can be achieved with 7 micro-g/sq cm Si on 1.7 micro-g/sq cm C; (2) an Si/C composite foil with a thin carbon layer is more effective in blocking UV radiation while having the lowest energy threshold of all the foils measured; and (3) transmittance of Si/C foils of known Si and C thicknesses cannot be accurately predicted, but must be measured.

Drake, V. A.↗

Theory and application of scanning electron acoustic microscopy

A three-dimensional theoretical model based on the application of the thermal conduction and Navier equations to a chopped electron beam incident on a disk specimen is used to obtain the particle displacement field in the specimen. The results lead to a consideration of the signal generation, spatial resolution, and contrast mechanisms in scanning electron acoustic microscopy (SEAM). The model suggests that the time-variant heat source produced by the beam chopping generates driving source, thermal wave, and acoustic wave displacements simultaneously in the specimen. Evidence of the correctness of the prediction is obtained from the mathematically similar problem of pulsed laser light injection into a tank of water. High speed Schlieren photographs taken following laser injection show the simultaneous evolution of thermal and acoustic waveforms. Examples of contrast reversal, stress-induced contrast, and acoustic zone contrast and resolution with SEAM are presented and explained in terms of the model features.

Cantrell, John H.↗

A procedure for the frequency analysis of telerobotic tasks data

In the last few years, teleoperated tasks have been the subject of extensive research to determine the best combination of control modalities according to specific criteria. The operator's performance were compared on the basis of task completion time and of force and torque measurements during the tasks. This paper proposes a procedure for the spectral analysis of force and torque signals generated during teleoperation experiments. There are two main reasons for examining teleoperation data in the frequency domain: a spectral analysis of different tasks can validate the assumptions made in the design of the teleoperator, and a task's frequency signature can be a valuable measure of the operator's performance.

Fiorini, Paolo↗

Versatile Controller For CCD's

General-purpose controller for charge-coupled device (CCD) programmed to accommodate variety of CCD designs. In operation of controller, software used to specify CCD-clock waveforms, available in great diversity. Includes timing-signal generator controlled by microcomputer. Flexibility and speed makes it versatile tool for laboratory testing and for variety of applications. Controller operates existing CCD's and able to operate CCD's expected to be developed in foreseeable future.

Novello, J.↗

Integrated optics in an electrically scanned imaging Fourier transform spectrometer

An efficient, lightweight and stable, Fourier transform spectrometer was developed. The mechanical slide mechanism needed to create a path difference was eliminated by the use of retro-reflecting mirrors in a monolithic interferometer assembly in which the mirrors are not at 90 degrees to the propagation vector of the radiation, but rather at a small angle. The resulting plane wave fronts create a double-sided inteferogram of the source irradiance distribution which is detected by a charge-coupled device image sensor array. The position of each CCD pixel in the array is an indication of the path difference between the two retro-reflecting mirrors in the monolithic optical structure. The Fourier transform of the signals generated by the image sensor provide the spectral irradiance distribution of the source. For imaging, the interferometer assembly scans the source of irradiation by moving the entire instrument, such as would occur if it was fixedly mounted to a moving platform, i.e., a spacecraft. During scanning, the entrace slot to the monolithic optical structure sends different pixels to corresponding interferograms detected by adjacent columns of pixels of the image sensor.

Breckinridge, James B.↗

Multichannel error correction code decoder

A brief overview of a processing satellite for a mesh very-small-aperture (VSAT) communications network is provided. The multichannel error correction code (ECC) decoder system, the uplink signal generation and link simulation equipment, and the time-shared decoder are described. The testing is discussed. Applications of the time-shared decoder are recommended.

Wagner, Paul K.↗

An active antenna for ELF magnetic fields

The work of Nikola Tesla, especially that directed toward world-wide electrical energy distribution via excitation of the earth-ionosphere cavity resonances, has stimulated interest in the study of these resonances. Not only are they important for their potential use in the transmission of intelligence and electrical power, they are important because they are an integral part of our natural environment. This paper describes the design of a sensitive, untuned, low noise active antenna which is uniquely suited to modern earth-ionosphere cavity resonance measurements employing fast-Fourier transform techniques for near-real-time data analysis. It capitalizes on a little known field-antenna interaction mechanism. Recently, the authors made preliminary measurements of the magnetic fields in the earth-ionosphere cavity. During the course of this study, the problem of designing an optimized ELF magnetic field sensor presented itself. The sensor would have to be small, light weight (for portable use), and capable of detecting the 5-50 Hz picoTesla-level signals generated by the natural excitations of the earth-ionosphere cavity resonances. A review of the literature revealed that past researchers had employed very large search coils, both tuned and untuned. Hill and Bostick, for example, used coils of 30,000 turns wound on high permeability cores of 1.83 m length, weighing 40 kg. Tuned coils are unsuitable for modern fast-Fourier transform data analysis techniques which require a broad spectrum input. 'Untuned' coils connected to high input impedance voltage amplifiers exhibit resonant responses at the resonant frequency determined by the coil inductance and the coil distributed winding capacitance. Also, considered as antennas, they have effective areas equal only to their geometrical areas.

Sutton, John F.↗

SpaceHab 1 maintenance experiment

The SpaceHab 1 flight on STS-57 served as a test platform for evaluation of two space station payloads. The first payload evaluated a space station maintenance concept using a sweep signal generator and a 48-channel logic analyzer to perform fault detection and isolation. Crew procedures files, test setup diagram files, and software to configure the test equipment were created on the ground and uplinked on the astronauts' voice communication circuit to perform tests in flight. In order to use these files, the portable computer was operated in a multi-window configuration. The test data transmitted to the ground allowing the ground staff to identify the cause of the fault and provide the crew with the repair procedures and diagrams. The crew successfully repaired the system under test. The second payload investigated hand soldering and de-soldering of standard components on printed circuit (PC) boards in zero gravity. It also used a new type of intra-vehicular foot restraints which uses the neutral body posture in zero-g to provide retention of the crew without their conscious attention.

Bohannon, Jackie W.↗

An automated digital data collection and analysis system for the Charpy Impact Tester

The standard Charpy Impact Tester has been modified by the addition of a system of hardware and software to improve the accuracy and consistency of measurements made during specimen fracturing experiments. An optical disc, light source, and detector generate signals that indicate the pendulum position as a function of time. These signals are used by a computer to calculate the velocity and kinetic energy of the pendulum as a function of its position.

Kohne, Glenn S.↗

Apparatus and method for determining the mass density of a filament

A method and apparatus for determining the mass density of a moving filament is provided. The method includes the steps of providing a filament across two supports, tensioning the filament, inducing a vibration into the filament segment between the supports, reinforcing the vibration using an amplified feedback signal, detecting the vibrational frequency data, processing the data using a fast-fourier transform analysis, and then displaying the frequency. The use of the feedback signal results in a self-tuning resonant loop. Open loop versions may also be used. The apparatus includes a base supporting a fixed support and a transducer which in turn supports a moveable support. The transducer vibrates the moveable support transversely to the direction of travel of the filament, thereby inducing a transverse vibrational mode. The output of the transducer is amplified and used to drive a second amplifier to produce a self-tuning resonant loop. In the open loop version a signal generator is used to drive the transducer through a frequency range, during which the amplitude peak is identified.

Hinkley, Jeffrey A.↗

Interaction of chronic reatine depletion and muscle unloading effects on postural and locomotor muscles

In this study, creatine depletion was induced separately and in combination with non-weight-bearing activity to determine if the response to lowering this metabolite would counter the MHC transitions expected from non-weight-bearing. Creatine depletion was induced by feeding rats a diet supplemented with the creatine analogue beta-guanidinopropionic acid (beta-GPA). Animals were fed a diet containing the creatine analogue for 68 days. Hindlimb non-weight-bearing in BS and NS animals was accomplished by tail suspension for the final 30 days of this period. Beta-GPA feeding lowered the creatine content of muscles sampled by 65%. Creatine depletion resulted in a 16% increase in citrate synthase activity in the soleus (SOL) and a 24% increase in the plantaris (PLN). In two postural muscles, the SOL and vastus intermedius (VI), tail suspension resulted in large decreases in the type I MHC expression and increases in type IIx and IIb MHCs. In two locomotor muscles, the PLN and medial gastrocnemius, type I MHC declined and type IIb increased with suspension. Creatine depletion did not prevent the suspension-induced decline in type I MHC in any of these muscles. The increase in type IIb MHC was either prevented or reduced by creatine depletion before and during suspension in the SOL, VI, and PLN. Creatine depletion alone resulted in small increases in type I and IIa MHCs in the two locomotor muscles, but it had no effect on the MHC profile of the postural muscles studied. These results indicate that the mechanical signal generated by the hindlimb non-weight-bearing state dominated over the metabolic stimulus of creatine depletion with respect to the primary adaptation involving a reduction in type I MHC.

Adams, Gregory R.↗

Phase-Locked Loop For Measurement Of Small And Large Delays

Electronic signal-generating and processing subsystem of ultrasonic inspection or measurement system consists mainly of variable-and-fixed-frequency, pulsed phase-locked loop (VFFPPLL) measuring phase shifts from 0 degrees to more than 360 degrees with accurancy of 0.112 degrees. VFFPPLL measures phase shifts between transmitted ultrasonic toneburst and its echo, thereby measuring ultrasonic-propagation delay. Used to determine strain in bolt or to track irregular surface of specimen being inspected ultrasonically.

Froggatt, Mark↗

A Novel Photonic Clock and Carrier Recovery Device

As data communication rates climb toward ten Gb/s, clock recovery and synchronization become more difficult, if not impossible, using conventional electronic circuits. We present in this article experimental results of a high speed clock and carrier recovery using a novel device called a photonic oscillator that we recently developed in our laboratory. This device is capable of recovering clock signals up to 70 GHz. To recover the clock, the incoming data is injected into the photonic oscillator either through the optical injection port or the electrical injection port. The free running photonic oscillator is tuned to oscillate at a nominal frequency equal to the clock frequency of the incoming data. With the injection of the data, the photonic oscillator will be quickly locked to clock frequency of the data stream while rejecting other frequency components associated with the data. Consequently, the output of the locked photonic oscillator is a continuous periodical wave synchronized with the incoming data or simply the recovered clock. We have demonstrated a clock to spur ratio of more than 60 dB of the recovered clock using this technique. Similar to the clock recovery, the photonic oscillator can be used to recover a high frequency carrier degraded by noise and an improvement of about 50 dB in signal-to-noise ratio was demonstrated. The photonic oscillator has both electrical and optical inputs and outputs and can be directly interfaced with a photonic system without signal conversion. In addition to clock and carrier recovery, the photonic oscillator can also be used for (1) stable high frequency clock signal generation, (2) frequency multiplication, (3) square wave and comb frequency generation, and (4) photonic phase locked loop.

Yao, X. Steve↗

High-Performance X-ray Detection in a New Analytical Electron Microscope

X-ray detection by energy-dispersive spectrometry in the analytical electron microscope (AEM) is often limited by low collected X-ray intensity (P), modest peak-to-background (P/B) ratios, and limitations on total counting time (tau) due to specimen drift and contamination. A new AFM has been designed with maximization of P. P/B, and tau as the primary considerations. Maximization of P has been accomplished by employing a field-emission electron gun, X-ray detectors with high collection angles, high-speed beam blanking to allow only one photon into the detector at a time, and simultaneous collection from two detectors. P/B has been maximized by reducing extraneous background signals generated at the specimen holder, the polepieces and the detector collimator. The maximum practical tau has been increased by reducing specimen contamination and employing electronic drift correction. Performance improvments have been measured using the NIST standard Cr thin film. The 0-3 steradian solid angle of X-ray collection is the highest value available. The beam blanking scheme for X-ray detection provides 3-4 times greater throughput of X-rays at high count rates into a recorded spectrum than normal systems employing pulse-pileup rejection circuits. Simultaneous X-ray collection from two detectors allows the highest X-ray intensity yet recorded to be collected from the NIST Cr thin film. The measured P/B of 6300 is the highest level recorded for an AEM. In addition to collected X-ray intensity (cps/nA) and P/B measured on the standard Cr film, the product of these can be used as a figure-of-merit to evaluate instruments. Estimated minimum mass fraction (MMF) for Cr measured on the standard NIST Cr thin film is also proposed as a figure-of-merit for comparing X-ray detection in AEMs. Determinations here of the MMF of Cr detectable show at least a threefold improvement over previous instruments.

Lyman, C. E.↗