Search NASA⌕ Search

SEARCH · Search NASA

Results for “Signal processing algorithms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

High performance FPGA embedded system for machine learning based tracking and trigger in sPhenix and EIC

We present a comprehensive end-to-end pipeline to classify triggers versus background events in this paper. This pipeline makes online decisions to select signal data and enables the intelligent trigger system for efficient data collection in the Data Acquisition System (DAQ) of the upcoming sPHENIX and future EIC (Electron-Ion Collider) experiments. Starting from the coordinates of pixel hits that are lightened by passing particles in the detector, the pipeline applies three-stage of event processing (hits clustering, track reconstruction, and trigger detection) and labels all processed events with the binary tag of trigger versus background events. The pipeline consists of deterministic algorithms such as clustering pixels to reduce event size, tracking reconstruction to predict candidate edges, and advanced graph neural network-based models for recognizing the entire jet pattern. In particular, we apply the message-passing graph neural network to predict links between hits and reconstruct tracks and a hierarchical pooling algorithm (DiffPool) to make the graph-level trigger detection. We obtain an impressive performance (≥70% accuracy) for trigger detection with only 3200 neuron weights in the end-to-end pipeline. We deploy the end-to-end pipeline into a field-programmable gate array (FPGA) and accelerate the three stages with speedup factors of 1152, 280, and 21, respectively.

Instruments & Instrumentation↗

Enhancing Nanoparticle Detection in Interferometric Scattering (iSCAT) Microscopy Using a Mask R-CNN

Interferometric scattering microscopy (iSCAT) is a label-free optical microscopy technique that enables imaging of individual nano-objects such as nanoparticles, viruses, and proteins. Essential to this technique is the suppression of background scattering and identification of signals from nano-objects. In the presence of substrates with high roughness, scattering heterogeneities in the background, when coupled with tiny stage movements, cause features in the background to be manifested in background-suppressed iSCAT images. Traditional computer vision algorithms detect these background features as particles, limiting the accuracy of object detection in iSCAT experiments. Here, in this paper, we present a pathway to improve particle detection in such situations using supervised machine learning via a mask region-based convolutional neural network (mask R-CNN). Using a model iSCAT experiment of 19.2 nm gold nanoparticles adsorbing to a rough layer-by-layer polyelectrolyte film, we develop a method to generate labeled datasets using experimental background images and simulated particle signals and train the mask R-CNN using limited computational resources via transfer learning. We then compare the performance of the mask R-CNN trained with and without inclusion of experimental backgrounds in the dataset against that of a traditional computer vision object detection algorithm, Haar-like feature detection, by analyzing data from the model experiment. Results demonstrate that including representative backgrounds in training datasets improved the mask R-CNN in differentiating between background and particle signals and elevated performance by markedly reducing false positives. The methodology for creating a labeled dataset with representative experimental backgrounds and simulated signals facilitates the application of machine learning in iSCAT experiments with strong background scattering and thus provides a useful workflow for future researchers to improve their image processing capabilities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Faraday Michelson Interferometers for Signal Demodulation of Fiber-Optic Sensors

We developed an all-fiber-based optical demodulator for the signal interrogation of low-coherence fiber-optic Fabry–Perot interferometric sensors. The optical demodulator consists of a Michelson interferometer implemented by using a 3×3 fiber coupler and two fiber-coupled Faraday reflectors with tunable fiber delay lines. The demodulator's output contains two optical interference signals with a constant phase shift and the output shows no sensitivity to the polarization variation in the light source or fibers. A digital phase recovery algorithm is used to extract the measurand information from the phase-shifted signals at high accuracy, high dynamic range, and high stability. The optical demodulator has been applied to the measurement of high-frequency vibrations and strains using fiber-optic sensors.

47 OTHER INSTRUMENTATION↗

Structural analysis of molten materials by a remote fiber optic Raman sensor

This study presents a novel in situ high-temperature fiber optic Raman probe that enables the study of the physical properties and structure of molten samples at temperatures up to 1400 °C. To demonstrate the functionality of the high-temperature fiber optic Raman probe, different composition mold fluxes were evaluated in this report. The Raman spectra at flux molten temperature were successfully collected and analyzed. A deconvolution algorithm was employed to identify peaks in the spectra associated with the molecular structure of the components in each sample. Here, the experimental results demonstrate that the composition-dependent Raman signal shift can be detected at high temperatures, indicating that molten materials analysis using a high-temperature Raman system shows significant promise. This flexible and reliable high-temperature Raman measurement method has great potential for various applications, such as materials development, composition and structure monitoring during high-temperature processing, chemical identification, and process monitoring in industrial production.

47 OTHER INSTRUMENTATION↗

Laser-induced breakdown spectroscopy-based geochemical fingerprinting for the rapid analysis and discrimination of minerals: the example of garnet

Laser-induced breakdown spectroscopy (LIBS) is an analytical technique real-time geochemical analysis that is being developed for portable use outside of the laboratory. In this study, statistical signal processing and classification techniques were applied to single-shot, broadband LIBS spectra, comprising measured plasma light intensities between 200 and 960 nm, for a suite of 157 garnets of different composition from 92 locations worldwide. Partial least squares discriminant analysis was applied to sets of 25 LIBS spectra for each garnet sample and used to classify the garnet samples based on composition and geographic origin. Careful consideration was given to the cross-validation procedure to ensure that the classification algorithm is robust to unseen data. The results indicate that broadband LIBS analysis can be used to discriminate garnets of different composition and has the potential to discern geographic origin.

58 GEOSCIENCES↗

Evaluation of the PhaseNet Model Applied to the IMS Seismic Network

Producing a complete and accurate set of signal detections is essential for automatically building and characterizing seismic events of interest for nuclear explosion monitoring. Signal detection algorithms have been an area of research for decades, but still produce large quantities of false detections and misidentify real signals that must be detected to produce a complete global catalog of events of interest. Deep learning methods have shown promising capabilities in effectively characterizing seismic signals for complex tasks such as identifying phase arrival times. We use the PhaseNet model, a UNet-based Neural Network, trained on local distance data from northern California to predict seismic arrivals on data from the International Monitoring System (IMS) global network. We use an analyst-curated bulletin generated from this data set to compare the performance of PhaseNet to that of the Short-Term Average/Long-Term Average (STA/LTA) algorithm. We find that PhaseNet has the potential of outperforming traditional processing methods and recommend the training of a new model with the IMS data to achieve optimal performance.

58 GEOSCIENCES↗

Bayesian approach to the detection problem in gravitational wave astronomy

The analysis of data from gravitational wave detectors can be divided into three phases: search, characterization, and evaluation. The evaluation of the detection--determining whether a candidate event is astrophysical in origin or some artifact created by instrument noise--is a crucial step in the analysis. The ongoing analyses of data from ground-based detectors employ a frequentist approach to the detection problem. A detection statistic is chosen, for which background levels and detection efficiencies are estimated from Monte Carlo studies. This approach frames the detection problem in terms of an infinite collection of trials, with the actual measurement corresponding to some realization of this hypothetical set. Here we explore an alternative, Bayesian approach to the detection problem, that considers prior information and the actual data in hand. Our particular focus is on the computational techniques used to implement the Bayesian analysis. We find that the parallel tempered Markov chain Monte Carlo (PTMCMC) algorithm is able to address all three phases of the analysis in a coherent framework. The signals are found by locating the posterior modes, the model parameters are characterized by mapping out the joint posterior distribution, and finally, the model evidence is computed by thermodynamic integration. As a demonstration, we consider the detection problem of selecting between models describing the data as instrument noise, or instrument noise plus the signal from a single compact galactic binary. The evidence ratios, or Bayes factors, computed by the PTMCMC algorithm are found to be in close agreement with those computed using a reversible jump Markov chain Monte Carlo algorithm.

79 ASTRONOMY AND ASTROPHYSICS↗

Light Gluinos in Hiding: Reconstructing R-Parity Violating Decays at the Tevatron

If gluinos exist with masses less than 200 GeV, they are copiously produced at the Tevatron, but still may not have been discovered if they decay through baryon number violating operators. We show that using cuts on jet substructure can enable a discovery with existing data and even determine the gluino's mass. This contribution has demonstrated that the Tevatron can discover new light colored particles that decay into complicated hadronic final states, by using events where these particles are produced at high p{sub T} and their boosted decay products are collimated. The recently developed techniques using jet substructure can effectively separate signal from background, allowing the new particle to appear as a jet-mass resonance. This work is a proof-of-principle, but there is significantly more work to be done. Neither of the Tevatron's two detectors have calorimetry that is as finely segmented as the LHC detectors, where most studies have been done so far, and this may reduce the jet mass resolution and restrict the Tevatron reach. Some of this resolution loss may be recovered by using tracking information, particularly at CDF [99]. On the theoretical side, the optimal cuts and jet-size for a given mass have not been determined, nor have other jet algorithms such as Cambridge/Aachen been studied. Switching to a more inclusive analysis may also improve sensitivity. The primary challenge is to keep signal efficiency high due to the low number of gluinos in the high p{sub T} tail, e.g. with m{sub {tilde g}} = 150 GeV we see 18% of gluinos with p{sub T} > 350 GeV reconstructed using R = 1.0. Therefore it may be beneficial to search for one narrow gluino candidate jet with tight constraints recoiling against another wide jet-size gluino candidate jet. The application of loose substructure cuts to the jets of the ordinary di-jet search is also interesting. If the squarks become light enough that associated squark-gluino production or squark pair production becomes sizable, then the dominant source of boosted gluinos may come from these secondary processes. This is qualitatively similar to the models studied in [65] where the hadronically decaying LSP was being produced in cascade decays of squarks and gluinos.

43 PARTICLE ACCELERATORS↗

Passband Signal Detection at the Edge

Algorithms for radio frequency (RF) spectrum awareness need to be compatible with edge hardware to be practical for many applications. We developed a signal detection and classification model for the ZCU111 RF System-on-a-Chip (RFSoC) that operates on the fast Fourier transform of passband RF data. The system can detect and classify multiple signals of interest and display the predictions in real-time. The model consists of a modified ConvNeXt backbone and YOLOv3 head to operate on the Deep Learning Processing Unit on the RFSoC. We gathered datasets for training and testing by using a software defined radio to transmit example signals of Wi-Fi 802.11 b/g, Wi-Fi 802.11 n, FM Radio, LTE and LTE-M. By leveraging multiple inputs on the RFSoC frontend, the datasets span up to 4 GHz of bandwidth. The models showed high performance in classification accuracy, center frequency error, bandwidth error, and detection accuracy for both single and multi-signal datasets.

42 ENGINEERING↗

The potential of positron emission tomography for intratreatment dynamic lung tumor tracking: A phantom study

Purpose: This study aims to evaluate the potential and feasibility of positron emission tomography for dynamic lung tumor tracking during radiation treatment. The authors propose a center of mass (CoM) tumor tracking algorithm using gated-PET images combined with a respiratory monitor and investigate the geometric accuracy of the proposed algorithm. Methods: The proposed PET dynamic lung tumor tracking algorithm estimated the target position information through the CoM of the segmented target volume on gated PET images reconstructed from accumulated coincidence events. The information was continuously updated throughout a scan based on the assumption that real-time processing was supported (actual processing time at each frame ≈10 s). External respiratory motion and list-mode PET data were acquired from a phantom programmed to move with measured respiratory traces (external respiratory motion and internal target motion) from human subjects, for which the ground truth target position was known as a function of time. The phantom was cylindrical with six hollow sphere targets (10, 13, 17, 22, 28, and 37 mm in diameter). The measured respiratory traces consisted of two sets: (1) 1D-measured motion from ten healthy volunteers and (2) 3D-measured motion from four lung cancer patients. The authors evaluated the geometric accuracy of the proposed algorithm by quantifying estimation errors (Euclidean distance) between the actual motion of targets (1D-motion and 3D-motion traces) and CoM trajectories estimated by the proposed algorithm as a function of time. Results: The time-averaged error of 1D-motion traces over all trajectories of all targets was 1.6 mm. The error trajectories decreased with time as coincidence events were accumulated. The overall error trajectory of 1D-motion traces converged to within 2 mm in approximately 90 s. As expected, more accurate results were obtained for larger targets. For example, for the 37 mm target, the average error over all 1D-motion traces was 1.1 mm; and for the 10 mm target, the average error over all 1D-motion traces was 2.8 mm. The overall time-averaged error of 3D-motion traces was 1.6 mm, which was comparable to that of the 1D-motion traces. There were small variations in the errors between the 3D-motion traces, although the motion trajectories were very different. The accuracy of the estimates was consistent for all targets except for the smallest. Conclusions: The authors developed an algorithm for dynamic lung tumor tracking using list-mode PET data and a respiratory motion signal, and demonstrated proof-of-principle for PET-guided lung tumor tracking. The overall tracking error in phantom studies is less than 2 mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spectral encoding method for measuring the relative arrival time between x-ray/optical pulses

The advent of few femtosecond x-ray light sources brings promise of x-ray/optical pump-probe experiments that can measure chemical and structural changes in the 10–100 fs time regime. Widely distributed timing systems used at x-ray Free-Electron Laser facilities are typically limited to above 50 fs fwhm jitter in active x-ray/optical synchronization. The approach of single-shot timing measurements is used to sort results in the event processing stage. This has seen wide use to accommodate the insufficient precision of active stabilization schemes. In this article, we review the current technique for “measure-and-sort” at the Linac Coherent Light Source at the SLAC National Accelerator Laboratory. The relative arrival time between an x-ray pulse and an optical pulse is measured near the experimental interaction region as a spectrally encoded cross-correlation signal. The cross-correlation provides a time-stamp for filter-and-sort algorithms used for real-time sorting. Sub-10 fs rms resolution is common in this technique, placing timing precision at the same scale as the duration of the shortest achievable x-ray pulses.

43 PARTICLE ACCELERATORS↗

Distributed fiber sensing systems for 3D combustion temperature field monitoring in coal-fired boilers using optically generated acoustic waves (Final Report)

In this project, we have developed and tested three kinds of fiber optic sensing systems for real time monitoring of temperature variations within an industrial scale boiler furnace. The fiber optic sensing systems target spatial and temporal distributions of high temperature profiles in a boiler furnace in fossil power plants. The reconstructed temperature profile will provide critical input for the control mechanisms to optimize the combustion process. This temperature profile will address the essential problem for fossil power plants in achieving higher efficiency and fewer pollutant emissions. Acoustic pyrometer systems have been used to reconstruct temperature field of power plant boilers based on measuring TOF (times-of-flight) of sound waves along some straight paths in a 2D cross-section of the boiler. In this project, optically generated acoustic signals from a fiber optic sensing system have replaced the acoustic signals generated from an electrical transducer. A 3D reconstruction algorithm replaced the previous 2D model. In this project, three kinds of fiber optic sensing systems have been developed and tested. They are fiber optic sensing system I, fiber optic sensing system II (Distributed Sensing System I) and fiber optic sensing system III (Distributed Sensing System II). For fiber optic sensing system I, the fiber optic ultrasound generator acts as a signal generator. A microphone, hydrophone or other electronic devices serve as a signal receiver. In this system, there are one generator and one receiver. Distance test, water temperature test, air temperature test, air temperature reconstruction, and GE ISBF pilot test were performed by Fiber optic sensing system I. The fiber optic sensing system I successfully detected temperature in all these tests. We got 2D temperature reconstruction results by using the fiber optic sensing system I and it matched the reference data. The fiber optic sensing system I successfully survived in GE ISBF boiler environment (480 °F). For fiber optic sensing system II (Distributed Sensing System I), it is an all optical ultrasound system. The fiber optic ultrasound generator acts as a signal generator. Fiber Bragg Grating (FBG) and Fabry-Perot (FP) sensor act as a signal receiver. In this system, there is one generator and one receiver. Aluminum plate temperature test, furnace high temperature test, and GE ISBF pilot test were performed by the fiber optic sensing system II. Fiber optic sensing system II successfully detected the temperature in all these tests. The fiber optic sensing system II successfully survived at up to 700 °C furnace environment and 320 °C GE ISBF boiler environment. For fiber optic sensing system III (Distributed Sensing System II), it is also an all optical ultrasound system. The fiber optic ultrasound generator acts as a signal generator. Multiple FP fiber sensors act as signal receivers. In this system, there is one generator and three receivers. Three GE ISBF pilot tests were performed by fiber optic sensing system III. The fiber optic sensing system III survived in the cold flow tests in GE’s ISBF pilot test facility. However, we didn’t get high temperature data by using this system since the nanosecond laser issues. During the period of the project, test trials, data simulation and algorithm optimization was performed successfully. For real time temperature field construction, the sampling rate must be fast enough to capture the field variations. The technology of Code-division multiple access (CDMA) is well studied which could allow parallel multiplexing, even if signals overlap in time or frequencies. Moreover, it has been known that extending the length of signal significantly improves SNR. For acoustic signals, these multiplexing techniques have also been widely used, mainly for sonar and acoustic communications. The CDMA modulation technique has been proposed and studied to guarantee high network throughput, low channel access delay and low energy consumption. We have studied the temperature field reconstruction using Gaussian Radial Basis Functions (GRBF)-based approximation approach. Reconstruction of 3D temperature field using Neural Networks with measured TOF and known propagation paths is feasible. 2D and 3D temperature field reconstruction simulation results are achieved. The milestone status is shown in Table 1. We finished milestone 1-8 and milestone 10. For milestone 9, we did three pilot tests by using the fiber optic sensing system III (Distributed Sensing System II) at GE Power. However, due to the failure of the ns laser, we did not get the temperature results. We conducted some additional tasks that were not originally proposed: 1) We fabricated a fiber optic sensing system I and did a pilot test based on this system. 2) In the proposal, we proposed two pilot tests at GE Power. In reality, we finished at least seven pilot tests at GE Power. GE Power has made a lot of efforts for supporting the pilot tests. 3) We got a simulation results based on CDMA. In summary, most of the tasks have been accomplished. The outcome of this project removed a few barriers that hinder the achievement of the final product of the distributed sensing systems. With the successful accomplishment of this project, a prototype of the fiber optic sensing system can be fabricated to attract more interests from companies and other funding agencies.

47 OTHER INSTRUMENTATION↗

Second Annual Report on Development of Microwave Resonant Cavity Transducer for Fluid Flow Sensing

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with the flat wall of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the resonant frequency, which can be detected with a spectrum analyzer. Because the transducer is intended for immersion in a high temperature corrosive fluid, understanding of material degradation is crucial for estimation of transducer performance lifetime, and development of measurement interpretation algorithms. We conducted a preliminary computational investigation of relevant damage mechanisms of a stainless steel 316 cylindrical resonator in FLiBe salt. The two main damage mechanisms, creep and corrosion, were modeled using multiphysics COMSOL software. Degradation was modeled for a temperature range 500°C to 700°C. Coupling of the damage mechanisms was not considered. These models predict significant inelastic deformation at most temperatures due to creep, and qualitatively predict chromium depletion both along the liquid/solid interface and along the grain boundaries. An algorithmic approach for compensation of these degradation effects during fluid flow measurements will be developed in the future work. To validate sensor physics, we have performed proof-of-principle test of flow sensing in water. For this test, we have developed a cylindrical resonator for K-band, which was machined from brass. The cavity was excited through WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder. To increase the spectral signal visibility, we developed a signal processing method for baseline subtraction. A flow loop for proof-of-principle test of transducer performance in water was assembled. A commercial flow meter was installed in the loop for reference measurements. Cylindrical cavity was excited in the TE 011 mode with resonant frequency f ≈ 17.8GHz. Frequency shift of cavity spectral response was obtained by gradually increasing water flow rate from 0 to 60gpm. Corresponding monotonic increase of resonant frequency shift by several MHz was observed. Approximate figure of merit of sensitivity to flow rate is 100KHz/GPM. In addition, we have identified an existing liquid sodium experimental setup for demonstration of flow sensing in environment similar to that of an advanced reactor. The setup consists of a cylindrical vessel and center feed line, where transducer inserted through the lid will measure velocity of the impinging liquid jet. As a calibration experiment, we have assembled a water vessel with center feed with the same dimensions as those of the liquid sodium setup. We have also developed and insertion probe consisting of a 50cm brass waveguide enclosed in protective SS316 tube. Using the water loop, we have demonstrated feasibility of sensing the impinging liquid jet in the vessel.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Microfabricated Ion Traps on Sapphire for Larger Trap Areas and Higher Qubit Count

Surface ion traps are a promising platform for quantum computing due to their potential to store large numbers of ions that can be addressed by electrical and optical control signals in order to implement quantum algorithms. Increasing the power of the quantum computer requires increasing the number of ions, but this poses a significant challenge in that it leads to a non-linear increase in on-chip power dissipation. The primary contributor to this power scaling in current devices is the capacitance between the radio frequency (RF) electrode and the metal plane that shields the silicon substrate from the RF signals applied to it. Silicon has traditionally been chosen for the substrate material for compatibility with the processing required for multi-metal-level traps. In this work, we address these capacitance and fabrication challenges by replacing the commonly used silicon substrate with an insulating sapphire substrate to fabricate a multi-metal-level ion trap, while still employing common semiconductor manufacturing techniques. This change in substrate allows the design to remove the metal shielding from the device design, reducing the capacitance of the RF electrode. The electrical characteristics of these traps were measured, specifically trap impedance, capacitance, and voltage breakdown, and compared to nearly identical silicon trap devices. Finally, we used laser cutting techniques to shape a sapphire wafer into bowtie shapes matching silicon traps previously fabricated at Sandia National Labs to explore solutions for integrating sapphire substrates into non-rectangular ion trap designs.

97 MATHEMATICS AND COMPUTING↗

International Spine Radiosurgery Consortium Consensus Guidelines for Target Volume Definition in Spinal Stereotactic Radiosurgery

Purpose: Spinal stereotactic radiosurgery (SRS) is increasingly used to manage spinal metastases. However, target volume definition varies considerably and no consensus target volume guidelines exist. This study proposes consensus target volume definitions using common scenarios in metastatic spine radiosurgery. Methods and Materials: Seven radiation oncologists and 3 neurological surgeons with spinal radiosurgery expertise independently contoured target and critical normal structures for 10 cases representing common scenarios in metastatic spine radiosurgery. Each set of volumes was imported into the Computational Environment for Radiotherapy Research. Quantitative analysis was performed using an expectation maximization algorithm for Simultaneous Truth and Performance Level Estimation (STAPLE) with kappa statistics calculating agreement between physicians. Optimized confidence level consensus contours were identified using histogram agreement analysis and characterized to create target volume definition guidelines. Results: Mean STAPLE agreement sensitivity and specificity was 0.76 (range, 0.67-0.84) and 0.97 (range, 0.94-0.99), respectively, for gross tumor volume (GTV) and 0.79 (range, 0.66-0.91) and 0.96 (range, 0.92-0.98), respectively, for clinical target volume (CTV). Mean kappa agreement was 0.65 (range, 0.54-0.79) for GTV and 0.64 (range, 0.54-0.82) for CTV (P<.01 for GTV and CTV in all cases). STAPLE histogram agreement analysis identified optimal consensus contours (80% confidence limit). Consensus recommendations include that the CTV should include abnormal marrow signal suspicious for microscopic invasion and an adjacent normal bony expansion to account for subclinical tumor spread in the marrow space. No epidural CTV expansion is recommended without epidural disease, and circumferential CTVs encircling the cord should be used only when the vertebral body, bilateral pedicles/lamina, and spinous process are all involved or there is extensive metastatic disease along the circumference of the epidural space. Conclusions: This report provides consensus guidelines for target volume definition for spinal metastases receiving upfront SRS in common clinical situations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

THE CONTRIBUTION OF THE KINEMATIC SUNYAEV-ZEL'DOVICH EFFECT FROM THE WARM-HOT INTERGALACTIC MEDIUM TO THE FIVE-YEAR WILKINSON MICROWAVE ANISOTROPY PROBE DATA

We study the contribution of the kinematic Sunyaev-Zel'dovich (kSZ) effect, generated by the warm-hot intergalactic medium, to the cosmic microwave background temperature anisotropies in the five-year Wilkinson Microwave Anisotropy Probe (WMAP) data. We explore the concordance {lambda}CDM cosmological model, with and without this kSZ contribution, using a Markov chain Monte Carlo algorithm. Our model requires a single extra parameter to describe this new component. Our results show that the inclusion of the kSZ signal improves the fit to the data without significantly altering the best-fit cosmological parameters except {omega}{sub b} h {sup 2}. The improvement is localized at the l {approx}> 500 multipoles. For the best-fit model, this extra component peaks at l {approx} 450 with an amplitude of 129 {mu}K{sup 2}, and represents 3.1% of the total power measured by WMAP. Nevertheless, at the 2{sigma} level a null kSZ contribution is still compatible with the data. Part of the detected signal could arise from unmasked point sources and/or Poissonianly distributed foreground residuals. A statistically more significant detection requires the wider frequency coverage and angular resolution of the forthcoming Planck mission.

99 GENERAL AND MISCELLANEOUS↗

Iterative Bragg peak removal on X-ray absorption spectra with automatic intensity correction

This study introduces a novel iterative Bragg peak removal with automatic intensity correction (IBR-AIC) methodology for X-ray absorption spectroscopy (XAS), specifically addressing the challenge of Bragg peak interference in the analysis of crystalline materials. The approach integrates experimental adjustments and sophisticated post-processing, including an iterative algorithm for robust calculation of the scaling factor of the absorption coefficients and efficient elimination of the Bragg peaks, a common obstacle in accurately interpreting XAS data, particularly in crystalline samples. The method was thoroughly evaluated on dilute catalysts and thin films, with fluorescence mode and large-angle rotation. The results underscore the technique's effectiveness, adaptability and substantial potential in improving the precision of XAS data analysis. While demonstrating significant promise, the method does have limitations related to signal-to-noise ratio sensitivity and the necessity for meticulous angle selection during experimentation. Overall, IBR-AIC represents a significant advancement in XAS, offering a pragmatic solution to Bragg peak contamination challenges, thereby expanding the applications of XAS in understanding complex materials under diverse experimental conditions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reconstructions from randomly generated longitudinal electron bunch profiles with Gaussian envelopes using the Gerchberg–Saxton algorithm

Knowledge of longitudinal electron bunch profiles is vital to optimize the performance of plasma wakefield accelerators and x-ray free electron laser linacs. Because of their importance to these novel applications, noninvasive frequency domain techniques are often employed to reconstruct longitudinal bunch profiles from coherent synchrotron, transition, or undulator radiation measurements. In this paper, we detail several common reconstruction techniques involving the Kramers–Kronig phase relationship and Gerchberg–Saxton algorithm. Additionally, through statistical analysis, we draw general conclusions about the accuracy of these reconstruction techniques and the most suitable candidate for reconstructing well-isolated longitudinal bunch profiles from spectroscopic data.

47 OTHER INSTRUMENTATION↗