Search NASA⌕ Search

SEARCH · Search NASA

Results for “Source Term Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Hanford Site Composite Analysis Technical Approach Description: Integrated Computational Framework.

The U.S. Department of Energy (DOE) in DOE O 435.1 Chg. 1, Radioactive Waste Management, requires the preparation and maintenance of a composite analysis (CA). The primary purpose of the CA is to provide a reasonable expectation that the primary public dose limit is not likely to be exceeded by multiple source terms that may significantly interact with plumes originating at a low-level waste disposal facility. The CA is used to facilitate planning and land use decisions that help assure disposal facility authorization will not result in long-term compliance problems; or, to determine management alternatives, corrective actions, or assessment needs if potential problems are identified.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Site Composite Analysis Technical Approach Description: Atmospheric Transport Modeling.

The U.S. Department of Energy (DOE) in DOE O 435.1 Chg. 1, Radioactive Waste Management, requires the preparation and maintenance of a composite analysis (CA). The primary purpose of the CA is to provide a reasonable expectation that the primary public dose limit is not likely to be exceeded by multiple source terms that may significantly interact with plumes originating at a low-level waste disposal facility. The CA is used to facilitate planning and land use decisions that help assure disposal facility authorization will not result in long-term compliance problems; or, to determine management alternatives, corrective actions or assessment needs, if potential problems are identified.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Site Composite Analysis Technical Approach Description: Waste Form Release.

The U.S. Department of Energy (DOE) in DOE O 435.1 Chg. 1, Radioactive Waste Management, requires the preparation and maintenance of a composite analysis (CA). The primary purpose of the CA is to provide a reasonable expectation that the primary public dose limit is not likely to be exceeded by multiple source terms that may significantly interact with plumes originating at a low-level waste disposal facility. The CA is used to facilitate planning and land use decisions that help assure disposal facility authorization will not result in long-term compliance problems; or, to determine management alternatives, corrective actions or assessment needs, if potential problems are identified.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Site Composite Analysis Technical Approach Description: Automated Quality Assurance Process Design.

The U.S. Department of Energy (DOE) in DOE O 435.1 Chg. 1, Radioactive Waste Management, requires the preparation and maintenance of a composite analysis (CA). The primary purpose of the CA is to provide a reasonable expectation that the primary public dose limit is not likely to be exceeded by multiple source terms that may significantly interact with plumes originating at a low-level waste disposal facility. The CA is used to facilitate planning and land use decisions that help assure disposal facility authorization will not result in long-term compliance problems; or, to determine management alternatives, corrective actions, or assessment needs if potential problems are identified.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Uranium Immobility in Tims Branch Wetland

The objective of this study was to address an item identified by the Low-Level Waste Disposal Facility Federal Review Group (LFRG) panel during their review of the Savannah River Site’s Composite Analysis. Their concern was that the Tims Branch wetland, which has elevated levels of uranium (U) originating from site operations between 1952 to 1985, may be a secondary source term, posing a human health risk. This report briefly describes three studies dealing with: 1) quantifying the mass of U remaining in the wetland, 2) quantifying the tendency of U to release from Tims Branch sediment, and 3) describing the distribution of U in aqueous and suspended solids in Tims Branch water during episodic storm events. The Tims Branch wetland has been extremely effective for the last 50 years at immobilizing U released to the system. A detailed map including 270,000 gamma spectra of the U distribution in the wetland indicated that 84% of the initial 43,500 kg U introduced in the system remain there after 50 years (Kaplan et al., 2020). The effectiveness of immobilizing U is supported by stream water measurements collected over the last several decades indicating that U concentrations have been consistently below drinking water regulatory limits (i.e., the EPA Maximum Contaminant Level, 30 pg/L (SRNS, 2019)). Furthermore, using contaminated Tims Branch sediments, in situ desorption Kd values (ratio of U sediment/U Water) were extremely high, ranging from 104to 106 L/kg, suggesting the U is strongly bound to these wetland sediments. Finally, a detailed study of Tims Branch stream water properties during episodic rain events indicated that essentially all the U transported in this stream was associated with suspended solids (Batson et al., 1996). Together these findings indicate that the Tims Branch wetland is extremely effective in its present state at immobilizing U and that the small masses of U released downstream will be predominantly in association with suspended solids.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

User’s Manual for RESRAD-RDD&IND Code Version 2: Vol. 2—User’s Guide for RESRAD-RDD&IND Code

Version 2.0 of the RESRAD-RDD&IND computer code is designed to support the implementation of protective action guides (PAGs) after a nuclear emergency incident including a radiological dispersal device (RDD) and/or an improvised nuclear device (IND) incident (EPA 2017). Eight different group types, addressing various decisions, are available for selection. The RESRAD-RDD&IND code calculates radiological doses, stay times, etc., for the selected group that the user wishes to focus on. (That is, the results for all the groups are not calculated simultaneously, and the input for those other groups do not matter, although some parameter values are shared between groups.) Version 2.0 has a user-friendly interface so that the RESRAD-RDD&IND code can be used with minimal training. For example, the user can select the major characteristics of the problem-event type, source term, and decision type from the left side of the interface and then calculate the results with the default assumptions for the exposure scenarios. More in-depth analysis would include specifying site-specific exposure scenario characteristics in the right side of the interface. The procedures for data entry and results viewing are self-explanatory. This is because common window maneuvering features and text instructions were incorporated in the interface design. General and context-specific help are available to aid users entering parameter values, as well. The RESRAD-RDD&IND computer code gives the user the option to select either an RDD or IND incident for analysis. For an RDD event analysis, 11 radionuclides (Am-241, Cf-252, Cm-244, Co-60, Cs-137, Ir-192, Po-210, Pu-238, Pu-239, Ra-226, and Sr-90) are included. These 11 radionuclides are the radionuclides most likely used for an RDD. More than 90 radionuclides can be selected for an IND event analysis. Initial default concentrations are provided for 44 radionuclides for a uranium-fueled IND event. These 44 radionuclides are those that would contribute significantly to the radiation dose associated with a uranium-fueled bomb detonation. The radionuclides generated from ingrowth of these 44 initial radionuclides are also automatically included in the analysis. Pu-239, Cs-134m, Ru-105, and Rb-89 and their progeny can be selected for analysis if they are detected and their concentrations are determined. This user’s guide, which is Volume 2 of the User’s Manual for RESRAD-RDD&IND Code Version 2, provides instructions to users on how to install the RESRAD-RDD&IND code, navigate the interface, and use the various features, including those discussed above, to set up an analysis and view/print the results in text outputs. Volume 1 of the User’s Manual for RESRAD-RDD&IND Code Version 2 (Yu et al. 2026), which contains descriptions of the methodology and theoretical basis for dose modeling and the mathematical equations implemented in the code, can be accessed and viewed through the Help menu in the code or can be downloaded from the RESRAD website (https://resrad.evs.anl.gov).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Design of optimum acoustic treatment for rectangular ducts with flow

A design optimization technique for acoustic treatment in rectangular ducts with uniform mean flow is presented. The technique is based on the acoustic wave solution in terms of series of characteristic duct modes. The analysis allows multiple axial treatment sections along the length of the duct and requires a known modal characterization of the sound source. Conditions of acoustic pressure and acoustic velocity continuity are used to match modal solutions at planes of impedance discontinuity in the duct. Experimental techniques for obtaining this modal characterization are presented. Using duct modes measured at the source plane, the optimization technique is exercised to design an optimized single element liner in a case without mean flow, and optimized single and dual element liners in cases with mean flow. The validity of the program for predicting noise suppression is demonstrated by comparing analytical predictions with measured data for several (non-optimum) cases. Application to treatment design in turbomachinery exhaust ducts is considered.

Motsinger, R. E.↗

The analysis of delays in simulator digital computing systems. Volume 1: Formulation of an analysis approach using a central example simulator model

The effects of spurious delays in real time digital computing systems are examined. Various sources of spurious delays are defined and analyzed using an extant simulator system as an example. A specific analysis procedure is set forth and four cases are viewed in terms of their time and frequency domain characteristics. Numerical solutions are obtained for three single rate one- and two-computer examples, and the analysis problem is formulated for a two-rate, two-computer example.

Heffley, R. K.↗

Helicopter main-rotor noise: Determination of source contributions using scaled model data

Acoustic data from a test of a 40 percent model MBB BO-105 helicopter main rotor are scaled to equivalent full-scale flyover cases. The test was conducted in the anechoic open test section of the German-Dutch Windtunnel (DNW). The measured data are in the form of acoustic pressure time histories and spectra from two out-of-flow microphones underneath and foward of the model. These are scaled to correspond to measurements made at locations 150 m below the flight path of a full-scale rotor. For the scaled data, a detailed analysis is given for the identification in the data of the noise contributions from different rotor noise sources. Key results include a component breakdown of the noise contributions, in terms of noise criteria calculations of a weighted sound pressure level (dBA) and perceived noise level (PNL), as functions of rotor advance ratio and descent angle. It is shown for the scaled rotor that, during descent, impulsive blade-vortex interaction (BVI) noise is the dominant contributor to the noise. In level flight and mild climb, broadband blade-turbulent wake interaction (BWI) noise is dominant due to the absence of BVI activity. At high climb angles, BWI is reduced and self-noise from blade boundary-layer turbulence becomes the most prominent.

Brooks, Thomas F.↗

Amazon Basin ozone and aerosol - Wet season observations

The ozone and aerosol number density data obtained from aircraft flights over the Amazon Basin (AB) during April and May of 1987 are summarized with particular attention given to the general characteristics of ozone and aerosol for wet season (WS), compared to dry season (DS), meteorology. It is concluded that the AB provides favorable conditions for the production of hydroxyl radical and subsequent chemical and photochemical reactions which generate or consume key atmospheric trace species. It is determined that a negative ozone gradient exists within the mixed layer (ML). WSML ozone is about 7 ppbv lower than that of DS. The net sink characteristics of the WSML are seen throughout the troposphere of the AB in that the ozone at 3-4 km altitude is typically 15-25 ppbv as compared to DS values of 30-35 ppbv. In terms of aerosol source characteristics of the AB, ML aerosols are 5-10 times higher than observed in the troposphere with ML values of 100-200 aerosols/cu cm. An analysis of aerosol size distribution data is presented.

Gregory, Gerald L.↗

Long-Term Performance of Transuranic Waste Inadvertently Disposed in a Shallow Land Burial Trench at the Nevada Test Site

In 1986, 21 m3 of transuranic (TRU) waste was inadvertently disposed in a shallow land burial trench at the Area 5 Radioactive Waste Management Site on the Nevada Test Site. U.S. Department of Energy (DOE) TRU waste must be disposed in accordance with Title 40, Code of Federal Regulations (CFR), Part 191, Environmental Radiation Protection Standard for Management and Disposal of Spent Nuclear Fuel, High-Level, and Transuranic Radioactive Wastes. The Waste Isolation Pilot Plant is the only facility meeting these requirements. The National Research Council, however, has found that exhumation of buried TRU waste for disposal in a deep geologic repository may not be warranted when the effort, exposures, and expense of retrieval are not commensurate with the risk reduction achieved. The long-term risks of leaving the TRU waste in-place are evaluated in two probabilistic performance assessments. A composite analysis, assessing the dose from all disposed waste and interacting sources of residual contamination, estimates an annual total effective dose equivalent (TEDE) of 0.01 mSv, or 3 percent of the dose constraint. A 40 CFR 191 performance assessment also indicates there is reasonable assurance of meeting all requirements. The 40 CFR 191.15 annual mean TEDE for a member of the public is estimated to reach a maximum of 0.055 mSv at 10,000 years, or approximately 37 percent of the 0.15 mSv individual protection requirement. In both assessments greater than 99 percent of the dose is from co-disposed low-level waste. The simulated probability of the 40 CFR 191.13 cumulative release exceeding 1 and 10 times the release limit is estimated to be 0.0093 and less than 0.0001, respectively. Site characterization data and hydrologic process modeling support a conclusion of no groundwater pathway within 10,000 years. Monte Carlo uncertainty analysis indicates that there is reasonable assurance of meeting all regulatory requirements. Sensitivity analysis indicates that the results are insensitive to TRU waste-related parameters. Limited quantities of TRU waste in a shallow land burial trench can meet DOE performance objectives for disposal of TRU waste and contribute negligibly to disposal site risk. Leaving limited quantities of buried TRU waste in-place may be preferred over retrieval for disposal in a deep geologic repository.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis and interpretation of Wide Field Planetary Camera outgas data collected in the temperature range from -20 C to -100 C

The data from the Wide Field Planetary Camera (WFPC) are analyzed to determine the absolute source-emission parameters and contaminant reemission parameters of outgassing mass accumulation. The data correspond to the mass accumulated on a -100 C quartz crystal microbalance and then desorbed at -50 C as a function of time. The parameters investigated include contaminant mass, first-order rate constants, and characteristic energies. The data are modeled in terms of a minimum number of species characterized by source-rate and reemission-rate parameters. The modeling technique is found to produce adequate fits, and the contaminants that accumulate at -100 C and desorb at -50 C do not accumulate at -50 C. The data analysis is found to be an adequate technique for assessing outgassing parameters for the prediction of WFPC internal contamination.

Barengoltz, Jack B.↗

Generalized Subtraction Schemes for the Difference Formulation in Radiation Transport

In the difference formulation for the transport of thermally emitted photons, the photon intensity is defined relative to a reference field, the black body at the local material temperature. This choice of reference field removes the cancellation between thermal emission and absorption that is responsible for noise in the Monte Carlo solution of thick systems, but introduces time and space derivative source terms that can not be determined until the end of the time step. It can also lead to noise induced crashes under certain conditions where the real physical photon intensity differs strongly from a black body at the local material temperature. In this report, we consider a difference formulation relative to the material temperature at the beginning of the time step, and in the situations where the radiation intensity more closely follows a temperature other than the local material temperature, that temperature. The result is a method where iterative solution of the material energy equation is efficient and noise induced crashes are avoided. To support our contention that the resulting generalized subtraction scheme is robust, and therefore suitable for practical use, we perform a stability analysis in the thick limit where instabilities usually occur.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Severe Weather Outbreak of 10 November 2002: Lightning and Radar Analysis of Storms in the Deep South

On the afternoon and evening of 10 November 2002, the Midwest and Deep South were struck by a major outbreak of severe storms that produced some 80 tornadoes. In terms of number of tornadoes, this was the largest outbreak in the United States since November 1992. Some 32 of the tornadoes occurred in Tennessee, Mississippi, Alabama and Georgia, including several long-track killers. We use the North Alabama Lightning Mapping Array (LMA) and other data sources to perform a comprehensive analysis of the structure and evolution of the outbreak. Most of the Southern tornadoes occurred in isolated, fast-moving supercell storms that formed in warm, moist air ahead of a major cold front. Storms tended to form in lines parallel to storm cell motion, resulting in many communities being hit multiple times by severe storms that evening. Supercells in Tennessee produced numerous strong tornadoes with short to medium-length track paths, while the supercells further south produced several very long-track tornadoes. Radar data indicate that the Tennessee storms tended to split frequently, apparently limiting their ability to sustain long-lived tornadoes, while storms further south split at most one time. The differences between these storms appear to be related to the presence of stronger jetstream winds in Tennessee relative to those present in Mississippi, Alabama and Georgia. LMA-derived flash rates associated with most of the supercell storm cores were about 1-2 flashes per second. Rapid increases in lightning rates (or "jumps") occurred prior to tornado touchdown in many instances. Lightning "holes" (lightning-free regions associated with the echo-free vault) occurred in two of the Tennessee supercells. The complexity of the relationship between lightning and storm severity is revealed by the behavior of one Alabama supercell, which produced a peak flash rate of nearly 14 flashes per second, well after the end of its long-track tornado, while interacting and ultimately merging with a daughter supercell on its southwest flank. Close examination of this powerful storm indicates that its prodigious flash rate was the result of strong flash activity over an unusually large area, rather than a concentrated core of extremely high flash rate activity.

Buechler, D. E.↗

A stochastic perturbation theory for non-autonomous systems

We develop a perturbation theory for a class of first order nonlinear non-autonomous stochastic ordinary differential equations that arise in climate physics. The perturbative procedure produces moments in terms of integral delay equations, whose order by order decay is characterized in a Floquet-like sense. Both additive and multiplicative sources of noise are discussed and the question of how the nature of the noise influences the results is addressed theoretically and numerically. By invoking the Martingale property, we rationalize the transformation of the underlying Stratonovich form of the model to an Ito form, independent of whether the noise is additive or multiplicative. The generality of the analysis is demonstrated by developing it both for a Brownian particle moving in a periodically forced quartic potential, which acts as a simple model of stochastic resonance, as well as for our more complex climate physics model. The validity of the approach is shown by comparison with numerical solutions. The particular climate dynamics problem upon which we focus involves a low-order model for the evolution of Arctic sea ice under the influence of increasing greenhouse gas forcing ΔF{sub 0}. The deterministic model, developed by Eisenman and Wettlaufer [“Nonlinear threshold behavior during the loss of Arctic sea ice,” Proc. Natl. Acad. Sci. U.S.A. 106(1), 28–32 (2009)] exhibits several transitions as ΔF{sub 0} increases and the stochastic analysis is used to understand the manner in which noise influences these transitions and the stability of the system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

LONG-TERM OPTICAL POLARIZATION VARIABILITY OF THE TeV BLAZAR 1ES 1959+650

A detailed analysis of the optical polarimetric variability of the TeV blazar 1ES 1959+650 from 2007 October 18 to 2011 May 5 is presented. The source showed maximum and minimum brightness states in the R band of 14.08 {+-} 0.03 mag and 15.20 {+-} 0.03 mag, respectively, with a maximum variation of 1.12 mag, and a maximum polarization degree of P = (12.2 {+-} 0.7)%, with a maximum variation of 10.7%. From 2009 August to November, a correlation between the optical R-band flux and the degree of linear polarization was found with a correlation coefficient r {sub pol} = 0.984 {+-} 0.025. The source presented a preferential position angle of optical polarization of {approx}153 Degree-Sign , with variations of 10 Degree-Sign -50 Degree-Sign , which is in agreement with the projected position angle of the parsec-scale jet found at 43 GHz. From the Stokes parameters we infer the existence of two optically thin synchrotron components that contribute to the polarized flux. One of them is stable with a constant polarization degree of 4%. Assuming a stationary shock for the variable component, we estimated some parameters associated with the physics of the relativistic jet: the magnetic field, B {approx} 0.06 G, the Doppler factor, {delta}{sub 0} {approx} 23, the viewing angle, {Phi} {approx} 2. Degree-Sign 4, and the size of the emission region r{sub b} {approx} 5.6 Multiplication-Sign 10{sup 17} cm. Our study is consistent with the spine-sheath model of explaining the polarimetric variability displayed by this source during our monitoring.

79 ASTRONOMY AND ASTROPHYSICS↗

Dose Rate Analysis of the WCS Consolidated Interim Storage Facility

This report describes a confirmatory calculation for a proposed consolidated interim storage facility (CISF) to support the US Nuclear Regulatory Commission’s review of the license application submitted by the Interim Storage Partners. The scope of this report is limited to an assessment of the annual dose from direct radiation associated with Phase 1 of the Waste Control Specialists (WCS) CISF and the determination of the minimum controlled area boundary based on the 10 CFR 72.104 limit of 25 mrem annual dose to the whole body. The confirmatory dose rate calculations used the source term and shielding calculation capabilities of the SCALE 6.2.3 computer code system. The calculation method employed in the confirmatory calculations uses a detailed Monte Carlo radiation transport simulation from source to dose rate. This method differs from the two-step method used in the safety analysis report (SAR), which requires determination of the photon and neutron energy and angular distributions on the cask external surface and then the use of this surface source in a new radiation transport calculation to determine dose rate as a function of distance from the storage facility. A simulation was made using the complete site geometry (all casks present) but with only one cask containing source, and a total of 467 independent calculations were performed to obtain the dose rate maps produced by each storage cask. Basic input data and assumptions used in the SAR (e.g., cask design parameters and design basis assembly characteristics) were used in this confirmatory calculation for consistency with the SAR. Local atmospheric conditions for skyshine calculations were simulated using US standard atmosphere data, which describe average air temperature, pressure, and density as a function of altitude. The determined minimum required distances from the WCS Phase 1 CISF to a contour defined by the 25 mrem annual dose limit were approximately 623 m (0.387 miles) in the N-NE direction, 594 m (0.369 miles) in the SSW direction, and 533 m (0.331 miles) in the E-SE direction and the W-NW direction. The annual dose results of the confirmatory calculation are in relatively good agreement with the annual dose values presented in the WCS SAR. The annual dose produced by the Phase 1 CISF at the nearest site boundary, 0.75 miles away from the CISF, was estimated by this study to be approximately 6.02E-02 ± 2.0E-04 mrem, which is significantly smaller than the 25 mrem annual dose limit provided in 10 CFR 72.104. The SAR annual dose rate value for the nearest site boundary was 7.52E-2 mrem, which included 7.73E-03 mrem due to postulated leakage of the FO-, FC-, and FF-canisters. A comparison with the dose rate values reported in the SAR for 16 detector locations, D1 through D16, on the protected area boundary is also included in this report. This comparison shows that the SAR determined higher annual dose values for detectors D1 through D14 by 12% to 45% and lower annual dose values for detectors D15 and D16 by 18% and 8%, respectively, as compared with this ORNL confirmatory calculation. Sensitivity studies have been performed to support a comprehensive review of the application. In these studies, the effects on dose rate of the modeled air volume, density, and humidity were analyzed. The sensitivity calculations showed that the air volume used in the Monte Carlo simulations was adequate and that a larger air volume would not further increase the dose rate due to skyshine contributions. The sensitivity analysis showed that simulation of local atmospheric conditions is important for the accuracy of dose rate estimates at large distances from the facility. Air humidity was demonstrated to have negligible effects on dose rate values for the simulated local atmospheric conditions.

61 RADIATION PROTECTION AND DOSIMETRY↗

Environmental impact assessment of solid waste management in Beijing City, China

The environmental impacts of municipal solid waste management in Beijing City were evaluated using a life-cycle-based model, EASEWASTE, to take into account waste generation, collection, transportation, treatment/disposal technologies, and savings obtained by energy and material recovery. The current system, mainly involving the use of landfills, has manifested significant adverse environmental impacts caused by methane emissions from landfills and many other emissions from transfer stations. A short-term future scenario, where some of the landfills (which soon will reach their capacity because of rising amount of waste in Beijing City) are substituted by incinerators with energy recovery, would not result in significant environmental improvement. This is primarily because of the low calorific value of mixed waste, and it is likely that the incinerators would require significant amounts of auxiliary fuels to support combustion of wet waste. As for the long-term future scenario, efficient source separation of food waste could result in significant environmental improvements, primarily because of increase in calorific value of remaining waste incinerated with energy recovery. Sensitivity analysis emphasized the importance of efficient source separation of food waste, as well as the electricity recovery in incinerators, in order to obtain an environmentally friendly waste management system in Beijing City.

09 BIOMASS FUELS↗