Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spatial resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

SU-G-206-02: Impact of Focal Spot Sizes On CT Image Quality

Purpose: To quantify a radiology team’s assessment of image quality differences between two CT scanner models currently in clinical use, with emphasis on spatial resolution that could be impacted by focal spot size. Methods: Modulation Transfer Functions (MTF) measurements were performed by scanning the impulse source insert module of the Catphan 600 at 120/140 kVp with both large (LFS) and small (SFS) focal spots and reconstructed to 2.5mm and 5.0mm thicknesses on a GE Discovery CT750 HD and a LightSpeed VCT CT scanner. MTFs were calculated by summing the 2D PSF along one-dimension to obtain line-spread-function (LSF), and calculating the Fourier Transform of the zero-padded and background corrected LSF. Spatial resolution performance was evaluated by comparing MTF curves, 50% and 10% MTF cutoff, and total area under the MTF curve (AUC). In addition, images of the Catphan high-contrast module and a Kagaku anthropomorphic body phantom were acquired from the HD scanner for visual comparisons. Results: For each scanner model, SFS was superior to LFS spatial resolution with respect to 50%/10% MTF cutoff and AUC. For the HD, 50%/10% cutoff was 4.29/7.22cm-1 for the LFS and 4.43/7.45cm-1 for the SFS. VCT outperformed HD, with 50%/10% cutoff of 4.40/7.29 cm-1 for LFS and 4.62/7.47cm-1 for SFS. Scanner model performance in order of decreasing AUC performance was VCT SFS (7.43), HD SFS (7.20), VCT LFS (7.09) and HD LFS (6.93). Visual evaluations of Kagaku phantom images confirmed that VCT outperformed HD. Conclusion: VCT outperformed HD and small focal spot is desired for either model over large focal spot in term of spatial resolution – in agreement with radiologist feedback of overall image quality. In-depth evaluations of clinical impact and focal spot selection mechanisms is currently being assessed.

60 APPLIED LIFE SCIENCES↗

Impact of light-absorbing particles on snow albedo darkening and associated radiative forcing over high-mountain Asia: high-resolution WRF-Chem modeling and new satellite observations

Light-absorbing particles (LAPs), mainly dust and black carbon, can significantly impact snowmelt and regional water availability over high-mountain Asia (HMA). In this study, for the first time, online aerosol–snow interactions are enabled and a fully coupled chemistry Weather Research and Forecasting (WRF-Chem) regional model is used to simulate LAP-induced radiative forcing on snow surfaces in HMA at relatively high spatial resolution (12 km, WRF-HR) compared with previous studies. Simulated macro- and microphysical properties of the snowpack and LAP-induced snow darkening are evaluated against new spatially and temporally complete datasets of snow-covered area, grain size, and impurity-induced albedo reduction over HMA. A WRF-Chem quasi-global simulation with the same configuration as WRF-HR buta coarser spatial resolution (1°, WRF-CR) is also used to illustrate the impact of spatial resolution on simulations of snow properties and aerosol distribution over HMA. Due to a more realistic representation of terrain slopes over HMA, the higher-resolution model (WRF-HR) shows significantly better performance in simulating snow area cover, duration of snow cover, snow albedo and snow grain size over HMA, as well as an evidently better atmospheric aerosol loading and mean LAP concentration in snow. However, the differences in albedo reduction from model and satellite retrievals is large during winter due to associated overestimation in simulated snow fraction. It is noteworthy that Himalayan snow cover has high magnitudes of LAP-induced snow albedo reduction (4% - 8%) in pre-monsoon seasons (both from WRF-HR and satellite estimates), which induces a snow-mediated radiative forcing of ~30-50 W m -2 . As a result, the Himalayas (specifically the western Himalayas) hold the most vulnerable glaciers and mountain snowpack to the LAP-induced snow darkening effect within HMA. In summary, coarse spatial resolution and absence of snow–aerosol interactions over the Himalayan cryosphere will result insignificant underestimation of aerosol effects on snow melting and regional hydroclimate.

54 ENVIRONMENTAL SCIENCES↗

Nuclear photonics

With the planned new {gamma}-beam facilities like MEGa-ray at LLNL (USA) or ELI-NP at Bucharest (Romania) with 10{sup 13}{gamma}/s and a band width of {Delta}E{gamma}/E{gamma} Almost-Equal-To 10{sup -3}, a new era of {gamma} beams with energies up to 20MeV comes into operation, compared to the present world-leading HI{gamma}S facility at Duke University (USA) with 10{sup 8}{gamma}/s and {Delta}E{gamma}/E{gamma} Almost-Equal-To 3 Dot-Operator 10{sup -2}. In the long run even a seeded quantum FEL for {gamma} beams may become possible, with much higher brilliance and spectral flux. At the same time new exciting possibilities open up for focused {gamma} beams. Here we describe a new experiment at the {gamma} beam of the ILL reactor (Grenoble, France), where we observed for the first time that the index of refraction for {gamma} beams is determined by virtual pair creation. Using a combination of refractive and reflective optics, efficient monochromators for {gamma} beams are being developed. Thus, we have to optimize the total system: the {gamma}-beam facility, the {gamma}-beam optics and {gamma} detectors. We can trade {gamma} intensity for band width, going down to {Delta}E{gamma}/E{gamma} Almost-Equal-To 10{sup -6} and address individual nuclear levels. The term 'nuclear photonics' stresses the importance of nuclear applications. We can address with {gamma}-beams individual nuclear isotopes and not just elements like with X-ray beams. Compared to X rays, {gamma} beams can penetrate much deeper into big samples like radioactive waste barrels, motors or batteries. We can perform tomography and microscopy studies by focusing down to {mu}m resolution using Nuclear Resonance Fluorescence (NRF) for detection with eV resolution and high spatial resolution at the same time. We discuss the dominating M1 and E1 excitations like the scissors mode, two-phonon quadrupole octupole excitations, pygmy dipole excitations or giant dipole excitations under the new facet of applications. We find many new applications in biomedicine, green energy, radioactive waste management or homeland security. Also more brilliant secondary beams of neutrons and positrons can be produced.

43 PARTICLE ACCELERATORS↗

High-resolution whole-brain DCE-MRI using constrained reconstruction: Prospective clinical evaluation in brain tumor patients

Purpose: To clinically evaluate a highly accelerated T1-weighted dynamic contrast-enhanced (DCE) MRI technique that provides high spatial resolution and whole-brain coverage via undersampling and constrained reconstruction with multiple sparsity constraints. Methods: Conventional (rate-2 SENSE) and experimental DCE-MRI (rate-30) scans were performed 20 minutes apart in 15 brain tumor patients. The conventional clinical DCE-MRI had voxel dimensions 0.9 × 1.3 × 7.0 mm{sup 3}, FOV 22 × 22 × 4.2 cm{sup 3}, and the experimental DCE-MRI had voxel dimensions 0.9 × 0.9 × 1.9 mm{sup 3}, and broader coverage 22 × 22 × 19 cm{sup 3}. Temporal resolution was 5 s for both protocols. Time-resolved images and blood–brain barrier permeability maps were qualitatively evaluated by two radiologists. Results: The experimental DCE-MRI scans showed no loss of qualitative information in any of the cases, while achieving substantially higher spatial resolution and whole-brain spatial coverage. Average qualitative scores (from 0 to 3) were 2.1 for the experimental scans and 1.1 for the conventional clinical scans. Conclusions: The proposed DCE-MRI approach provides clinically superior image quality with higher spatial resolution and coverage than currently available approaches. These advantages may allow comprehensive permeability mapping in the brain, which is especially valuable in the setting of large lesions or multiple lesions spread throughout the brain.

60 APPLIED LIFE SCIENCES↗

IONIZATION SOURCE OF A MINOR-AXIS CLOUD IN THE OUTER HALO OF M82

The M82 ''cap'' is a gas cloud at a projected radius of 11.6 kpc along the minor axis of this well-known superwind source. The cap has been detected in optical line emission and X-ray emission and therefore provides an important probe of the wind energetics. In order to investigate the ionization source of the cap, we observed it with the Kyoto3DII Fabry-Perot instrument mounted on the Subaru Telescope. Deep continuum, H{alpha}, [N II]{lambda}6583/H{alpha}, and [S II]{lambda}{lambda}6716,6731/H{alpha} maps were obtained with subarcsecond resolution. The superior spatial resolution compared to earlier studies reveals a number of bright H{alpha} emitting clouds within the cap. The emission line widths ({approx}< 100 km s{sup -1} FWHM) and line ratios in the newly identified knots are most reasonably explained by slow to moderate shocks velocities (v{sub shock} 40-80 km s{sup -1}) driven by a fast wind into dense clouds. The momentum input from the M82 nuclear starburst region is enough to produce the observed shock. Consequently, earlier claims of photoionization by the central starburst are ruled out because they cannot explain the observed fluxes of the densest knots unless the UV escape fraction is very high (f{sub esc} > 60%), i.e., an order of magnitude higher than observed in dwarf galaxies to date. Using these results, we discuss the evolutionary history of the M82 superwind. Future UV/X-ray surveys are expected to confirm that the temperature of the gas is consistent with our moderate shock model.

79 ASTRONOMY AND ASTROPHYSICS↗

EXTENDING THE NEARBY GALAXY HERITAGE WITH WISE: FIRST RESULTS FROM THE WISE ENHANCED RESOLUTION GALAXY ATLAS

The Wide-field Infrared Survey Explorer (WISE) mapped the entire sky at mid-infrared wavelengths 3.4 {mu}m, 4.6 {mu}m, 12 {mu}m, and 22 {mu}m. The mission was primarily designed to extract point sources, leaving resolved and extended sources, for the most part, unexplored. Accordingly, we have begun a dedicated WISE Enhanced Resolution Galaxy Atlas (WERGA) project to fully characterize large, nearby galaxies and produce a legacy image atlas and source catalog. Here we demonstrate the first results of the WERGA project for a sample of 17 galaxies, chosen to be of large angular size, diverse morphology, and covering a range in color, stellar mass, and star formation. It includes many well-studied galaxies, such as M 51, M 81, M 87, M 83, M 101, and IC 342. Photometry and surface brightness decomposition is carried out after special super-resolution processing, achieving spatial resolutions similar to that of Spitzer Infrared Array Camera. The enhanced resolution method is summarized in the first paper of this two-part series. In this second work, we present WISE, Spitzer, and Galaxy Evolution Explorer (GALEX) photometric and characterization measurements for the sample galaxies, combining the measurements to study the global properties. We derive star formation rates using the polycyclic aromatic hydrocarbon sensitive 12 {mu}m (W3) fluxes, warm-dust sensitive 22 {mu}m (W4) fluxes, and young massive-star sensitive ultraviolet (UV) fluxes. Stellar masses are estimated using the 3.4 {mu}m (W1) and 4.6 {mu}m (W2) measurements that trace the dominant stellar mass content. We highlight and showcase the detailed results of M 83, comparing the WISE/Spitzer results with the Australia Telescope Compact Array H I gas distribution and GALEX UV emission, tracing the evolution from gas to stars. In addition to the enhanced images, WISE's all-sky coverage provides a tremendous advantage over Spitzer for building a complete nearby galaxy catalog, tracing both stellar mass and star formation histories. We discuss the construction of a complete mid-infrared catalog of galaxies and its complementary role of studying the assembly and evolution of galaxies in the local universe.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of Research Infrastructure in Nevada for the Exploitation of Hyperspectral Image Data to Address Proliferation and Detection of Chemical and Biological Materials.

This research was to exploit hyperspectral reflectance imaging technology for the detection and mapping variability (clutter) of the natural background against which gases in the atmosphere are imaged. The natural background consists of landscape surface cover composed of consolidated rocks, unconsolidated rock weathering products, soils, coatings on rock materials, vegetation, water, materials constructed by humans, and mixtures of the above. Human made gases in the atmosphere may indicate industrial processes important to detecting non-nuclear chemical and biological proliferation. Our research was to exploit the Visible and Near-Infrared (NIR) and the Short-wave Infrared (SWIR) portions of the electromagnetic spectrum to determine the properties of solid materials on the earth’s surface that could influence the detection of gases in the Long-Wave Infrared (LWIR). We used some new experimental hyperspectral imaging technologies to collect data over the Non-Proliferation Test and Evaluation Center (NPTEC) located on the Nevada Test Site (NTS). The SpecTIR HyperSpecTIR (HST) and Specim Dual hyperspectral sensors were used to understand the variability in the imaged background (clutter), that detected, measured, identified and mapped with operational commercial hyperspectral techniques. The HST sensors were determined to be more experimental than operational because of problems with radiometric and atmospheric data correction. However the SpecTIR Dual system, developed by Specim in Finland, eventually was found to provide cost-effective hyperspectral image data collection and it was possible to correct the Dual system’s data for specific areas. Batch processing of long flightlines was still complex, and if comparison to laboratory spectra was desired, the Dual system data still had to be processed using the empirical line method. This research determined that 5-meter spatial resolution was adequate for mapping natural background variations. Furthermore, this research determined that spectral resolution of 10um was adequate, but a signal to noise above 300:1 was desirable for hyperspectral sensors with this spectral resolution. Finally, we acquired a hyperspectral thermal dataset (SEBASS) at 3m spatial resolution over our study area in Beatty, Nevada that can be co-registered with the hyperspectral reflectance, LIDAR and digital Orthophoto data sets. This data set will enable us to quantify how measurements in the reflected infrared can be used to make inferences about the response of materials in the thermal infrared, the topic of our follow-on NA-22 investigation ending in 2008. These data provide the basis for our investigations proposed for the NA-22 2008 Broad Area Announcement. Beginning in June 2008, SpecTIR Corporation and Aerospace Corporation plan to fly the SpecTIR Dual and SEBASS in a stabilized mount in a twin Otter aircraft. This research provides the foundation for using reflected and emitted hyperspectral measurements together for mapping geologic and soil materials in arid to semi-arid regions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

AFIP-7 Tomography – 2013 Status Report

This project seeks to assess the geometric stability of the U-Mo monolithic fuel system by evaluating the radiation-induced changes in the AFIP-7 experiment device. Neutron radiography and computed tomography (CT) provide valuable information about the post-irradiation condition of the fuel specimen. Tomographic reconstructions of the AFIP-7 fuel element will be analyzed to assess the geometric condition of the element after irradiation and provide information regarding the condition of the fuel, including gross geometric defects, bowing, twist, plate buckling, cracks, and other defects. The INL, in collaboration with Oregon State University (OSU), Missouri University of Science and Technology (Missouri S&T), and Real Time Tomography, is developing advanced neutron detector systems and tomographic reconstruction techniques to evaluate the AFIP-7 fuel element. Neutron computed tomography using the current neutron radiography technique available at the Neutron Radiography reactor (NRAD) is impractical due to the long time and high cost to produce a set of images for tomographic reconstruction. Advanced neutron radiography systems such as the micro-channel plate (MCP) detector and neutron computed radiography (CR) may reduce the time and cost of acquiring images for neutron CT. The MCP detector system tested at OSU and Missouri S&T provides neutron radiographs and has lower gamma sensitivity compared to other digital acquisition image systems. However, some significant, but not prohibitive, challenges must be overcome to make its use for imaging nuclear fuel more practical. Images taken with the MCP require significant image processing to reduce distortions and correct for the dynamic detector response. Also, the small active area of the detector (~30 mm diameter) requires the collection and combination of several images of a specimen, which may become time-consuming. The MCP is tested in low gamma dose environments, but should also be tested in the gamma field at the INL. In addition to the MCP detector system, the INL is developing neutron computed radiography (CR), which uses the same foil transfer method currently employed at the NRAD, but replaces the film with a photostimulable storage phosphor imaging plate that is sensitive to the decay radiation from the activated transfer foils. Preliminary tests show that neutron CR provides lower, but comparable spatial resolution properties to film radiography images using the transfer method technique already employed at the NRAD. However, there are many factors that affect the spatial resolution of neutron CR that can be adjusted and possibly provide spatial resolution properties that exceed film radiography. The reduction in cost of neutron CR may be significant, which would make neutron imaging more appealing to programs that would benefit from this rare and valuable capability. Because transfer method neutron radiography is expensive and time-consuming, acquisition of a full set of radiographs for tomographic reconstruction is impractical. The INL is developing tomographic reconstruction techniques that require only a small set of radiographs of the AFIP-7 fuel element. These tomosynthesis techniques are tested using archived radiographs of TREAT experiments for CT as a proof of principle. These same techniques are applied to radiographs taken with an MCP detector of a mock-up of the AFIP-7 geometry. Acquisition angle should at least match the curvature of AFIP-7 plates. Lateral (in-plane) reconstruction resolution will be best when the projection angles include views at or near the desired reconstruction view angles. The ends of the fuel plates are angled at ±17.7° relative to the center of the plate. Increasing the number of projections is desirable, but given the constraint of minimizing the number of projections, the projection acquisition angle should also span at least ±17.7° to optimize the lateral resolution of the angled reconstruction planes used to visualize the gaps at the ends of the fuel plates. If possible, enough projections should be used within the initial acquisition angle of 35.4° (±17.7°) to bring the projection angular sampling closer to 1°. Further testing will determine a more specific recommendation for the number and angular distribution of neutron radiographs that will produce the highest quality tomographic reconstruction of the AFIP-7 fuel element.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Soft x-ray ptychography studies of nanoscale magnetic and structural correlations in thin SmCo 5 films

High spatial resolution magnetic x-ray spectromicroscopy at x-ray photon energies near the cobalt L 3 resonance was applied to probe an amorphous 50 nm thin SmCo 5 film prepared by off-axis pulsed laser deposition onto an x-ray transparent 200 nm thin Si 3 N 4 membrane. Alternating gradient magnetometry shows a strong in-plane anisotropy and an only weak perpendicular magnetic anisotropy, which is confirmed by magnetic transmission soft x-ray microscopy images showing over a field of view of 10 μm a primarily stripe-like domain pattern but with local labyrinth-like domains. Soft x-ray ptychography in amplitude and phase contrast was used to identify and characterize local magnetic and structural features over a field of view of 1 μm with a spatial resolution of about 10 nm. There, the magnetic labyrinth domain patterns are accompanied by nanoscale structural inclusions that are primarily located in close proximity to the magnetic domain walls. In conclusion, our analysis suggests that these inclusions are nanocrystalline Sm 2 Co 17 phases with nominally in-plane magnetic anisotropy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Using gap-filled MAIAC AOD and WRF-Chem to estimate daily PM 2.5 concentrations at 1 km resolution in the Eastern United States

To link short-term exposures of air pollutants to health outcomes, scientists must use high temporal and spatial resolution estimates of PM 2.5 concentrations. We develop a daily PM 2.5 product at 1 × 1 km 2 spatial resolution across the eastern United States (east of 90° W) with the aid of 1 × 1 km 2 MAIAC aerosol optical depth (AOD) data, 36 × 36 km 2 WRF-Chem output, 1 × 1 km 2 land-use type from the National Land Cover Database, and 0.125° × 0.125° ERA-Interim re-analysis meteorology. A gap-filling technique is applied to MAIAC AOD data to construct robust daily estimates of AOD when the satellite data are missing (e.g., areas obstructed by clouds or snow cover). The input data are incorporated into a multiple-linear regression model trained to surface observations of PM 2.5 from the EPA Air Quality System (AQS) monitoring network. The model generates a high-fidelity estimate (r 2 = 0.75 using a 10-fold random cross-validation) of daily PM 2.5 throughout the eastern United States. Of the inputs to the statistical model, WRF-Chem output (r 2 = 0.66) is the most important contributor to the skill of the model. MAIAC AOD is also a strong contributor (r 2 = 0.52). Daily PM 2.5 output from our statistical model can be easily integrated into county-level epidemiological studies. The novelty of this project is that we are able to simulate PM 2.5 in a computationally efficient manner that is constrained to ground monitors, satellite data, and chemical transport model output at high spatial resolution (1 × 1 km 2 ) without sacrificing the temporal resolution (daily) or spatial coverage (>2,000,000 km 2 ).

47 OTHER INSTRUMENTATION↗

Assessment of the sources of error affecting the quantitative accuracy of SPECT imaging in small animals

Small animal SPECT imaging systems have multiple potential applications in biomedical research. Whereas SPECT data are commonly interpreted qualitatively in a clinical setting, the ability to accurately quantify measurements will increase the utility of the SPECT data for laboratory measurements involving small animals. In this work, we assess the effect of photon attenuation, scatter and partial volume errors on the quantitative accuracy of small animal SPECT measurements, first with Monte Carlo simulation and then confirmed with experimental measurements. The simulations modeled the imaging geometry of a commercially available small animal SPECT system. We simulated the imaging of a radioactive source within a cylinder of water, and reconstructed the projection data using iterative reconstruction algorithms. The size of the source and the size of the surrounding cylinder were varied to evaluate the effects of photon attenuation and scatter on quantitative accuracy. We found that photon attenuation can reduce the measured concentration of radioactivity in a volume of interest in the center of a rat-sized cylinder of water by up to 50percent when imaging with iodine-125, and up to 25percent when imaging with technetium-99m. When imaging with iodine-125, the scatter-to-primary ratio can reach up to approximately 30percent, and can cause overestimation of the radioactivity concentration when reconstructing data with attenuation correction. We varied the size of the source to evaluate partial volume errors, which we found to be a strong function of the size of the volume of interest and the spatial resolution. These errors can result in large (>50percent) changes in the measured amount of radioactivity. The simulation results were compared with and found to agree with experimental measurements. The inclusion of attenuation correction in the reconstruction algorithm improved quantitative accuracy. We also found that an improvement of the spatial resolution through the use of resolution recovery techniques (i.e. modeling the finite collimator spatial resolution in iterative reconstruction algorithms) can significantly reduce the partial volume errors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a MODIS-Derived Surface Albedo Data Set: An Improved Model Input for Processing the NSRDB

A significant source of bias in the transposition of global horizontal irradiance to plane-of-array (POA) irradiance arises from inaccurate estimations of surface albedo. The current physics-based model used to produce the National Solar Radiation Database (NSRDB) relies on model estimations of surface albedo from a reanalysis climatalogy produced at relatively coarse spatial resolution compared to that of the NSRDB. As an input to spectral decomposition and transposition models, more accurate surface albedo data from remotely sensed imagery at finer spatial resolutions would improve accuracy in the final product. The National Renewable Energy Laboratory (NREL) developed an improved white-sky (bi-hemispherical reflectance) broadband (0.3-5.0 ..mu..m) surface albedo data set for processing the NSRDB from two existing data sets: a gap-filled albedo product and a daily snow cover product. The Moderate Resolution Imaging Spectroradiometer (MODIS) sensors onboard the Terra and Aqua satellites have provided high-quality measurements of surface albedo at 30 arc-second spatial resolution and 8-day temporal resolution since 2001. The high spatial and temporal resolutions and the temporal coverage of the MODIS sensor will allow for improved modeling of POA irradiance in the NSRDB. However, cloud and snow cover interfere with MODIS observations of ground surface albedo, and thus they require post-processing. The MODIS production team applied a gap-filling methodology to interpolate observations obscured by clouds or ephemeral snow. This approach filled pixels with ephemeral snow cover because the 8-day temporal resolution is too coarse to accurately capture the variability of snow cover and its impact on albedo estimates. However, for this project, accurate representation of daily snow cover change is important in producing the NSRDB. Therefore, NREL also used the Integrated Multisensor Snow and Ice Mapping System data set, which provides daily snow cover observations of the Northern Hemisphere for the temporal extent of the NSRDB (1998-2015). We provide a review of validation studies conducted on these two products and describe the methodology developed by NREL to remap the data products to the NSRDB grid and integrate them into a seamless daily data set.

14 SOLAR ENERGY↗

Characterizing physical, chemical, and magnetic properties at the nanoscale

Synchrotron light sources are extremely useful for the characterization of materials in many different research fields (including physics, chemistry, materials science, biology, medicine, geology, and cultural heritage). The evolution of technology, however, currently points toward the miniaturization of devices and molecular motors, as well as the creation (through atomic manipulation) of new materials. This brings an acute necessity for direct chemical imaging of materials, i.e., with the use of x-ray microscopy at the nanometer and atomic length scales.1, 2 Although a variety of new x-ray nanoprobes and x-ray microscopy techniques have been developed in recent years, the spatial resolution of direct chemical or magnetic contrast imaging techniques remains on the order of several nanometers. Invented in the 1980s, scanning tunneling microscopy (STM) allows a large range of materials to be viewed at the atomic level.3 STM also offers a finer degree of spatial resolution than almost any other image technique, but it is chemically ‘blind’ and thus cannot be used alone to directly identify chemical elements on a surface. For many years, researchers have attempted to solve this problem by combining STM with synchrotron x-ray excitations,4–7 and a new technique—known as synchrotron xray scanning tunneling microscopy (SX-STM)—has emerged. In this technique—which combines the chemical sensitivity of xrays with the high spatial resolution of STM—a monochromatic x-ray beam is used to illuminate a tip-sample junction, while the tip makes raster scans across the sample surface. A feedback system maintains a tip–sample separation that is typically less than 1nm. The goal is tomodulate the tunneling current through x-ray excitation and therewith obtain electronic and chemical contrast. It is difficult, however, to achieve real chemical contrast because of three serious issues. First, electrons excited by x-rays do not just tunnel into the tip, but can also be ejected from the sample and hit the sidewalls of the tip detector (which degrades the spatial resolution). Second, because photoejected electrons still provide a deceptive current signal in the far field, the STM feedback system can lift the tip out of the tunneling regime without being noticed. Last, themeasured tip current is always a convolution of the conventional tunnel current (which is related to the sample topography) and the x-ray-excited electrons (which carry the material’s chemical information).

36 MATERIALS SCIENCE↗

HOYLE-LYTTLETON ACCRETION IN THREE DIMENSIONS

We investigate the stability of gravitational accretion of an ideal gas onto a compact object moving through a uniform medium at Mach 3. Previous three-dimensional simulations have shown that such accretion is not stable, and that strong rotational 'disk-like' flows are generated and accreted on short timescales. We re-address this problem using overset spherical grids that provide a factor of seven improvement in spatial resolution over previous simulations. With our higher spatial resolution we found these three-dimensional accretion flows remained remarkably axisymmetric. We examined two cases of accretion with different sized accretors. The larger accretor produced very steady flow, with the mass accretion rate varying by less than 0.02% over 30 flow times. The smaller accretor exhibited an axisymmetric breathing mode that modulated the mass accretion rate by a constant 20%. Nonetheless, the flow remained highly axisymmetric with only negligible accretion of angular momentum in both cases.

79 ASTRONOMY AND ASTROPHYSICS↗

Three-dimensional topological magnetic monopoles and their interactions in a ferromagnetic meta-lattice

Topological magnetic monopoles (TMMs), also known as hedgehogs or Bloch points, are three-dimensional (3D) nonlocal spin textures that are robust to thermal and quantum fluctuations due to the topology protection. Although TMMs have been observed in skyrmion lattices, spinor Bose–Einstein condensates, chiral magnets, vortex rings and vortex cores, it has been difficult to directly measure the 3D magnetization vector field of TMMs and probe their interactions at the nanoscale. Here, we report the creation of 138 stable TMMs at the specific sites of a ferromagnetic meta-lattice at room temperature. We further develop soft x-ray vector ptycho-tomography to determine the magnetization vector and emergent magnetic field of the TMMs with a 3D spatial resolution of 10 nm. This spatial resolution is comparable to the magnetic exchange length of transition metals, enabling us to probe monopole-monopole interactions. We find that the TMM and anti-TMM pairs are separated by 18.3±1.6 nm, while the TMM and TMM, anti-TMM and anti-TMM pairs are stabilized at comparatively longer distances of 36.1±2.4 nm and 43.1±2.0 nm, respectively. We also observe virtual TMMs created by magnetic voids in the meta-lattice. This work demonstrates that ferromagnetic meta lattices could be used as a platform to create and investigate the interactions and dynamics of TMMs. Furthermore, we expect that soft x-ray vector ptycho-tomography can be broadly applied to quantitatively image 3D vector fields in magnetic and anisotropic materials at the nanoscale.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Following Dynamic Processes by X-ray Tomographic Microscopy with Sub-second Temporal Resolution

Several non-destructive imaging techniques offer the possibility to observe rapid phenomena in real time, yet most of these techniques fail when it comes to bulky samples and micrometer precision in three dimensions. Therefore there is clearly a need to develop approaches that address such conditions. We identified the large potential that lies in synchrotron-based x-rays as a probe and developed a direct-space tomographic instrument suitable to provide sub-second temporal resolution with several-micrometers spatial resolution. Selected applications from the field of biology and material science are shown in order to demonstrate the unique capabilities in generating three-dimensional images with very high quality making image segmentation and analysis possible for samples that could, until now, only be studied in two dimensions due to the occurrence of rapid structural changes.

07 ISOTOPE AND RADIATION SOURCES↗

Time-resolved x-ray radiography of spark ignition plasma

Understanding the short-lived structure of the plasma that forms between the electrodes of a spark plug is crucial to the development of improved ignition models for SI engines. However, measuring the amount of energy deposited in the gas directly and non-intrusively is difficult, due to the short time scales and small length scales involved. The breakdown of the spark gap occurs at nanosecond time scales, followed by an arc phase lasting a few microseconds. Finally, a glow discharge phase occurs over several milliseconds. It is during the arc and glow discharge phases that most of the heat transfer from the plasma to the electrodes and combustion gases occurs. Light emission can be used to measure an average temperature, but micron spatial resolution is required to make localized measurements. In this paper, we present the results of a proof of concept experiment that demonstrates the use of time-resolved x-ray radiography to measure the density of the plasma in the spark gap during the glow discharge phase of a conventional transistorized coil ignition system. A focused monochromatic x-ray beam from the 7-BM beamline of the Advanced Photon Source at Argonne National Laboratory was used to make time-resolved point measurements of the projected density, which decreases as the plasma temperature increases. Multiple measurement positions were combined to produce a two-dimensional map of the projected density both inside and surrounding the spark gap. A temporal resolution of 153 ns and spatial resolution of 5 μm were achieved. A range of ambient gases, densities (1 - 3 bar) and ignition coil charging durations (1 - 2.5 ms) were considered. At least 30 repeated measurements were made for each sample point and condition. All these parameters were found to substantially alter the structure of the plasma as measured by x-ray radiography. From the projected density measurements, changes in thermal energy can be calculated. These provide a quantitative measurement of the energy deposited into the gas; this is only a small fraction of the total spark energy. The measurements demonstrate the feasibility of time-resolved x-ray radiography for the study of plasma structure and development for SI applications.

Kastengren, Alan L.↗

A dedicated cone-beam CT system for musculoskeletal extremities imaging: Design, optimization, and initial performance characterization

Purpose: This paper reports on the design and initial imaging performance of a dedicated cone-beam CT (CBCT) system for musculoskeletal (MSK) extremities. The system complements conventional CT and MR and offers a variety of potential clinical and logistical advantages that are likely to be of benefit to diagnosis, treatment planning, and assessment of therapy response in MSK radiology, orthopaedic surgery, and rheumatology. Methods: The scanner design incorporated a host of clinical requirements (e.g., ability to scan the weight-bearing knee in a natural stance) and was guided by theoretical and experimental analysis of image quality and dose. Such criteria identified the following basic scanner components and system configuration: a flat-panel detector (FPD, Varian 3030+, 0.194 mm pixels); and a low-power, fixed anode x-ray source with 0.5 mm focal spot (SourceRay XRS-125-7K-P, 0.875 kW) mounted on a retractable C-arm allowing for two scanning orientations with the capability for side entry, viz. a standing configuration for imaging of weight-bearing lower extremities and a sitting configuration for imaging of tensioned upper extremity and unloaded lower extremity. Theoretical modeling employed cascaded systems analysis of modulation transfer function (MTF) and detective quantum efficiency (DQE) computed as a function of system geometry, kVp and filtration, dose, source power, etc. Physical experimentation utilized an imaging bench simulating the scanner geometry for verification of theoretical results and investigation of other factors, such as antiscatter grid selection and 3D image quality in phantom and cadaver, including qualitative comparison to conventional CT. Results: Theoretical modeling and benchtop experimentation confirmed the basic suitability of the FPD and x-ray source mentioned above. Clinical requirements combined with analysis of MTF and DQE yielded the following system geometry: a {approx}55 cm source-to-detector distance; 1.3 magnification; a 20 cm diameter bore (20 x 20 x 20 cm{sup 3} field of view); total acquisition arc of {approx}240 deg. The system MTF declines to 50% at {approx}1.3 mm{sup -1} and to 10% at {approx}2.7 mm{sup -1}, consistent with sub-millimeter spatial resolution. Analysis of DQE suggested a nominal technique of 90 kVp (+0.3 mm Cu added filtration) to provide high imaging performance from {approx}500 projections at less than {approx}0.5 kW power, implying {approx}6.4 mGy (0.064 mSv) for low-dose protocols and {approx}15 mGy (0.15 mSv) for high-quality protocols. The experimental studies show improved image uniformity and contrast-to-noise ratio (without increase in dose) through incorporation of a custom 10:1 GR antiscatter grid. Cadaver images demonstrate exquisite bone detail, visualization of articular morphology, and soft-tissue visibility comparable to diagnostic CT (10-20 HU contrast resolution). Conclusions: The results indicate that the proposed system will deliver volumetric images of the extremities with soft-tissue contrast resolution comparable to diagnostic CT and improved spatial resolution at potentially reduced dose. Cascaded systems analysis provided a useful basis for system design and optimization without costly repeated experimentation. A combined process of design specification, image quality analysis, clinical feedback, and revision yielded a prototype that is now awaiting clinical pilot studies. Potential advantages of the proposed system include reduced space and cost, imaging of load-bearing extremities, and combined volumetric imaging with real-time fluoroscopy and digital radiography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗