Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Signal chain for the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS)

The AVIRIS instrument has a separate dedicated analog signal processing chain for each of its four spectrometers. The signal chains amplify low-level focal-plane line array signals (5 to 10 mV full-scale span) in the presence of larger multiplexing signals (approx 150 mV) providing the data handling system a ten-bit digital word (for each spectrometer) each 1.3 microns. This signal chain provides automatic correction for the line array dark signal nonuniformity (which can approach the full-scale signal span).

Bunn, James S., Jr.↗

HIRIS (High-Resolution Imaging Spectrometer: Science opportunities for the 1990s. Earth observing system. Volume 2C: Instrument panel report

The high-resolution imaging spectrometer (HIRIS) is an Earth Observing System (EOS) sensor developed for high spatial and spectral resolution. It can acquire more information in the 0.4 to 2.5 micrometer spectral region than any other sensor yet envisioned. Its capability for critical sampling at high spatial resolution makes it an ideal complement to the MODIS (moderate-resolution imaging spectrometer) and HMMR (high-resolution multifrequency microwave radiometer), lower resolution sensors designed for repetitive coverage. With HIRIS it is possible to observe transient processes in a multistage remote sensing strategy for Earth observations on a global scale. The objectives, science requirements, and current sensor design of the HIRIS are discussed along with the synergism of the sensor with other EOS instruments and data handling and processing requirements.

Source record↗

Synopsis of a computer program designed to interface a personal computer with the fast data acquisition system of a time-of-flight mass spectrometer

Briefly described are the essential features of a computer program designed to interface a personal computer with the fast, digital data acquisition system of a time-of-flight mass spectrometer. The instrumentation was developed to provide a time-resolved analysis of individual vapor pulses produced by the incidence of a pulsed laser beam on an ablative material. The high repetition rate spectrometer coupled to a fast transient recorder captures complete mass spectra every 20 to 35 microsecs, thereby providing the time resolution needed for the study of this sort of transient event. The program enables the computer to record the large amount of data generated by the system in short time intervals, and it provides the operator the immediate option of presenting the spectral data in several different formats. Furthermore, the system does this with a high degree of automation, including the tasks of mass labeling the spectra and logging pertinent instrumental parameters.

Bechtel, R. D.↗

An imaging spectrometer for the investigation of Mars

Unmanned misions to Mars will employ imaging spectrometry to yield compositional data about the target body, through visual and IR measurements of the intensity and distribution of characteristic spectral signature features in the radiation that is emitted and reflected by surface materials. Attention is presently given to a modular imaging spectrometer design with applicability to a diverse range of planetary missions. This visual and IR mapping spectrometer has been tentatively selected for NASA's recently approved Mars Observer mission. Detailed optical characteristics and capabilities of the instrument are presented.

Duval, James E.↗

A model-free method for mass spectrometer response correction

A new method for correction of mass spectrometer output signals is described. Response-time distortion is reduced independently of any model of mass spectrometer behavior. The delay of the system is found first from the cross-correlation function of a step change and its response. A two-sided time-domain digital correction filter (deconvolution filter) is generated next from the same step response data using a regression procedure. Other data are corrected using the filter and delay. The mean squared error between a step response and a step is reduced considerably more after the use of a deconvolution filter than after the application of a second-order model correction. O2 consumption and CO2 production values calculated from data corrupted by a simulated dynamic process return to near the uncorrupted values after correction. Although a clean step response or the ensemble average of several responses contaminated with noise is needed for the generation of the filter, random noise of magnitude not above 0.5 percent added to the response to be corrected does not impair the correction severely.

Shykoff, Barbara E.↗

Shuttle imaging spectrometer optics

This paper discusses the optical design and performance of the Shuttle Imaging Spectrometer (SISEX) optical system, which is being planned for the next generation of Earth remote sensing instruments. This optical system represents a new approach to remote sensing in which wide-field optics, dispersing elements, and area detector arrays are used in place of mechanical scanners, filters, and discrete detector elements or linear arrays. While the SISEX optical system is designed specifically for flight on Shuttle, the same optical approach is being used in the design of other remote sensing instruments, such as the High Resolution Imaging Spectrometer, which is expected to fly on the Earth Observing System.

Page, N. A.↗

Post-flare coronal arches observed with the SMM/XRP flat crystal spectrometer

Postflare coronal arch observations made with the SMM Flat Crystal Spectrometer on January 20-23, 1985 are discussed. Results suggest that the arch revival following the dynamic flare of 23:50 UT on January 1 was of the type noted on November 6-8 and June 4, 1980 by the SMM Hard X-ray Imaging Spectrometer (HXIS). Activity different from that of the HXIS observations was found starting at about 23 UT on January 22, with no trigger of the revival being identified, and with the activity being restricted to the coronal regions (without any related disturbance in the chromosphere). The development of the arch enhancement in the corona was shown to be slower than is expected for a flare-associated revival.

Hick, Paul↗

Imaging extreme ultraviolet spectrometer employing a single toroidal diffraction grating - The initial evaluation

The design and test results of a high-efficiency EUV imaging spectrometer employing a concave toroidal grating which is illuminated at normal incidence in a Rowland circle mounting and has only one reflecting surface are discussed. Photographic tests and initial photoelectric tests with a two-dimensional pulse-counting detector system demonstrate the excellent image quality of the grating at wavelengths near 600 A. Applications of the spectrometer for the study of nonsolar objects and solar regions (including the chromosphere, transition region, and corona) are considered.

Huber, M. C. E.↗

Mass spectrometer for measurements of relative ion concentrations in plasmas

A mass spectrometer which can be used to measure relative ion concentrations in a multiion component plasma has been designed for use in a strong (1-4-kG) uniform magnetic field. The spectrometer features an acceleration region which accelerates thermal ions through a series of three tantalum electrodes at a 30 deg angle to the B field, and a collection region in which ions are selectively collected, depending on the size of their gyroradii, by a cylindrical collector. Relative ion concentrations are determined from measurements of the collector current as a function of accelerating voltage. Results obtained using this instrument in a Q-machine device operated with a two-ion (Cs+/K+) component plasma are presented.

Suszcynsky, David M.↗

Delay-Line Anode For Microchannel-Plate Spectrometer

Photon-counting read-out system for microchannel-plate spectrometer includes delay line and timing circuit to measure wavelength coordinate and wedge/wedge charge-division system to measure orthogonal spatial coordinate. System proves advantageous for portable two-dimensional spectrometers having large image planes and for which design requirements include simplicity, reliability, low power consumption, and low mass.

Lampton, M.↗

Eight-Channel Spectrometer

Inexpensive, compact, battery-powered, eight-channel spectrometer produces 8-bit digital data in each channel and records data for subsequent reconstruction in analog form or for transmission to computer for analysis. Unit designed for use in analysis of rocket-exhaust plumes. Modified versions of spectrometer used to analyze combustion in boilers or gas turbines.

Huston, Steven W.↗

Calculating Response Of A Tunable-Diode-Laser Spectrometer

Response function calculated from measurements by iterative deconvolution procedure. Report describes measurements made with tunable-diode-laser spectrometer and processing of measurement data to calculate response function. Procedure fast and simple enough to be used to make routine corrections for broadening in diode-laser spectrometers.

May, Randy D.↗

Characterization of a turbomolecular-pumped magnetic sector mass spectrometer

A Perkin Elmer MGA-1200, turbomolecular-pumped, magnetic sector, multiple gas analyzer mass spectrometer with modified inlet for fast response was characterized for the analysis of hydrogen, helium, oxygen and argon in nitrogen and helium background gases. This instrument was specially modified for the Vanderberg AFB SLC-6 Hydrogen Disposal Test Program, as a part of the Hydrogen Sampling System (H2S2). Linearity, precision, drift, detection limits and accuracy among other analytical parameters for each of the background gas were studied to evaluate the performance of the instrument. The result demonstrates that H2S2 mass spectrometer is a stable instrument and can be utilized for the quantitative analytical determination of hydrogen, helium, oxygen and argon in nitrogen and helium background gases.

Mehta, Narinder K.↗

Re-examination of radiofrequency mass spectrometers: Center Director's Discretionary Fund

The three-stage, two-cycle, Bennett mass spectrometers in use in space and ground experiments today are of the same physical configuration as developed by Bennett in 1950. Sine-wave radiofrequency (RF) is also still used. The literature indicates that the electronics and physical manufacturing capabilities of 1950 technology may have limited the use of other improvements at that time. Therefore, a study, experimental and analytical, was undertaken to examine previously rejected RF approaches as well as new ones. The results of this study indicate there are other approaches which use fewer grids and square wave or a combination of square-wave and sine-wave RF. In regard to suppression of harmonics, none performed better than the three-stage, two-cycle, Bennett mass spectrometer. Use of square-wave RF in the Bennett approach can provide a slightly more compact configuration but no increase in throughput.

Carruth, M. R., Jr.↗

Automatic mineral map generation procedure from imaging spectrometer data

An airborne imaging spectrometer collected data for 128 wave length channels covering from near to short wavelength infrared across a 320 m swath, to help obtain a mineral map of an area based on reflectance spectral signatures of the area. Minerals have distinctive crystal structures and chemical contents which can be identified by their light absorption characteristics, and an optimized automatic mineral map generation procedure for imaging spectrometer data was developed. The procedure generates two types of mineral maps, a mineral distribution map showing spatial layout of various minerals and a mineral composition map showing the percentage composition of a selected mineral.

Lee, M.↗

In-flight radiometric calibration of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS)

A reflectance-based method was used to provide an analysis of the in-flight radiometric performance of AVIRIS. Field spectral reflectance measurements of the surface and extinction measurements of the atmosphere using solar radiation were used as input to atmospheric radiative transfer calculations. Five separate codes were used in the analysis. Four include multiple scattering, and the computed radiances from these for flight conditions were in good agreement. Code-generated radiances were compared with AVIRIS-predicted radiances based on two laboratory calibrations (pre- and post-season of flight) for a uniform highly reflecting natural dry lake target. For one spectrometer (C), the pre- and post-season calibration factors were found to give identical results, and to be in agreement with the atmospheric models that include multiple scattering. This positive result validates the field and laboratory calibration technique. Results for the other spectrometers (A, B and D) were widely at variance with the models no matter which calibration factors were used. Potential causes of these discrepancies are discussed.

Conel, James E.↗

Grille spectrometer (grille)

The Grille spectrometer was designed and flown on Spaceklab 1 by two organizations: The Office National d'Etudes et de Recherches Aerospatiales in France and the Belgian Institute for Space Aeronomy in Belgium. Its purpose is to study, on a global scale, atmospheric parameters between 15 and 150 km altitude. The investigation uses high-resolution (better than 0.1/cm) spectroscopic observations of the earth's limb in the wavelength range characteristic of the vibrational-rotational lines of the relevant atmospheric constituents. Characteristics and proposed modifications of the grille spectrometer are described. This instrument will be part of the atmospheric science research payload flown on the Atmospheric Laboratory for Applications and Science (ATLAS 1) NASA mission planned for late 1990.

Ackerman, M.↗

Signal chain for the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS)

The AVIRIS instrument has a separate dedicated analog signal processing chain for each of its four spectrometers. The signal chains amplify low-level focal-plane line array signals (5 to 10 mV full-scale span) in the presence of larger multiplexing signals (approx 150 mV) providing the data handling system a ten-bit digital word (for each spectrometer) each 1.3 microns. This signal chain provides automatic correction for the line array dark signal nonuniformity (which can approach the full-scale signal span).

Bunn, James S., Jr.↗