Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spectrum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Majorana neutrinos, neutrino mass spectrum, and the |<m>|{approx}10{sup -3} eV frontier in neutrinoless double beta decay

If future neutrino oscillation experiments show that the neutrino mass spectrum is with normal ordering, m{sub 1}<m{sub 2}<m{sub 3}, and the searches for neutrinoless double beta [({beta}{beta}){sub 0{nu}}] decay with sensitivity to values of the effective Majorana mass |<m>| > or approx. 10{sup -2} eV give negative results, the next frontier in the quest for ({beta}{beta}){sub 0{nu}}-decay will correspond to |<m>|{approx}10{sup -3} eV. By assuming that massive neutrinos are Majorana particles and their exchange is the dominant mechanism generating ({beta}{beta}){sub 0{nu}}-decay, we analyze the conditions under which |<m>|, in the case of three-neutrino mixing and a neutrino mass spectrum with normal ordering, would satisfy |<m>|{>=}0.001 eV. We consider the specific cases of (i) a normal hierarchical neutrino mass spectrum, (ii) a relatively small value of the CHOOZ angle {theta}{sub 13}, as well as (iii) the general case of a spectrum with normal ordering, a partial hierarchy, and a value of {theta}{sub 13} close to the existing upper limit. We study the ranges of the lightest neutrino mass m{sub 1} and/or of sin{sup 2}{theta}{sub 13} for which |<m>|{>=}0.001 eV and discuss the phenomenological implications of such scenarios. We provide also an estimate of |<m>| when the three-neutrino masses and the neutrino mixing originate from a neutrino mass term of the Majorana type for the (left-handed) flavor neutrinos and {sub j}{sup 3}m{sub j}U{sub ej}{sup 2}=0, but there does not exist a symmetry which forbids the ({beta}{beta}){sub 0{nu}}-decay.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Imprint of spatial curvature on inflation power spectrum

If the Universe had a large curvature before inflation there is a deviation from the scale invariant perturbations of the inflaton at the beginning of inflation. This may have some effect on the cosmic microwave background anisotropy at large angular scales. We calculate the density perturbations for both open and closed universe cases using the Bunch-Davies vacuum condition on the initial state. We use our power spectrum to calculate the temperature anisotropy spectrum and compare the results with the Wilkinson microwave anisotropy map five year data. We find that our power spectrum gives a lower quadrupole anisotropy when {omega}-1>0, but matches the temperature anisotropy calculated from the standard Ratra-Peebles power spectrum at large l. The determination of spatial curvature from temperature anisotropy data is not much affected by the different power spectra which arise from the choice of different boundary conditions for the inflaton perturbation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nonlinear evolution of f(R) cosmologies. II. Power spectrum

We carry out a suite of cosmological simulations of modified action f(R) models where cosmic acceleration arises from an alteration of gravity instead of dark energy. These models introduce an extra scalar degree of freedom which enhances the force of gravity below the inverse mass or Compton scale of the scalar. The simulations exhibit the so-called chameleon mechanism, necessary for satisfying local constraints on gravity, where this scale depends on environment, in particular, the depth of the local gravitational potential. We find that the chameleon mechanism can substantially suppress the enhancement of power spectrum in the nonlinear regime if the background field value is comparable to or smaller than the depth of the gravitational potentials of typical structures. Nonetheless power spectrum enhancements at intermediate scales remain at a measurable level for models even when the expansion history is indistinguishable from a cosmological constant, cold dark matter model. Simple scaling relations that take the linear power spectrum into a nonlinear spectrum fail to capture the modifications of f(R) due to the change in collapsed structures, the chameleon mechanism, and the time evolution of the modifications.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Band-power reconstruction of the primordial fluctuation spectrum by the maximum likelihood reconstruction method

The primordial curvature fluctuation spectrum is reconstructed by the maximum likelihood reconstruction method using the five-year Wilkinson Microwave Anisotropy Probe data of the cosmic microwave background temperature anisotropy. We apply the covariance matrix analysis and decompose the reconstructed spectrum into statistically independent band powers. The prominent peak off a simple power-law spectrum found in our previous analysis turn out to be a 3.3{sigma} deviation. From the statistics of primordial spectra reconstructed from mock observations, the probability that a primordial spectrum including such excess is realized in a power-law model is estimated to be about 2%.

39↗

Brute force reconstruction of the primordial fluctuation spectrum from five-year Wilkinson Microwave Anisotropy Probe observations

The primordial fluctuation spectrum is reconstructed from the five-year Wilkinson Microwave Anisotropy Probe data of the cosmic microwave background anisotropy. We divide the wave number space in the range of 1.23x10{sup -3} Mpc{sup -1} < or approx. k < or approx. 2.76x10{sup -2} Mpc{sup -1} into about 50 bins, and derive probability distributions of fluctuation amplitudes on the respective scales using Monte Carlo simulations. Although the reconstructed spectrum is basically consistent with a power-law spectrum, we find a hint of fine structure at k{approx_equal}0.002 Mpc{sup -1} and 0.009 Mpc{sup -1}. The former is observed only in the temperature anisotropy, while the latter is both in the temperature and polarization anisotropies. The significance of these features are discussed, and it is shown that the deviation from a power-law spectrum at k{approx_equal}0.009 Mpc{sup -1} is at 2.8{sigma} level.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of primordial non-Gaussianity using the WMAP 5-year temperature skewness power spectrum

We constrain the primordial non-Gaussianity parameter of the local model f{sub NL} using the skewness power spectrum associated with the two-to-one cumulant correlator of cosmic microwave background temperature anisotropies. This bispectrum-related power spectrum was constructed after weighting the temperature map with the appropriate window functions to form an estimator that probes the multipolar dependence of the underlying bispectrum associated with the primordial non-Gaussianity. We also estimate a separate skewness power spectrum sensitive more strongly to unresolved point sources. When compared to previous attempts at measuring the primordial non-Gaussianity with WMAP data, our estimators have the main advantage that we do not collapse information to a single number. When model fitting the two-to-one skewness power spectrum, we make use of bispectra generated by the primordial non-Gaussianity, radio point sources, and lensing-secondary correlation. We analyze Q, V, and W-band WMAP 5-year data using the KQ75 mask out to l{sub max}=600. Using V and W-band data and marginalizing over model parameters related to point sources and lensing-secondary bispectrum, our overall and preferred constraint on f{sub NL} is 11.0{+-}23.7 at the 68% confidence level (-36.4<f{sub NL}<58.4 at 95% confidence). We find no evidence for a nonzero value of f{sub NL} even marginally at the 1{sigma} level.

99 GENERAL AND MISCELLANEOUS↗

A method for 21 cm power spectrum estimation in the presence of foregrounds

The technique of 21 cm tomography promises to be a powerful tool for estimating cosmological parameters, constraining the epoch of reionization, and probing the so-called dark ages. However, realizing this promise will require the extraction of a cosmological power spectrum from beneath overwhelmingly large sources of foreground contamination. In this paper, we develop a unified matrix-based framework for foreground subtraction and power spectrum estimation, which allows us to quantify the errors and biases that arise in the power spectrum as a result of foreground subtraction. We find that existing line-of-sight foreground subtraction proposals can lead to substantial mode mixing as well as residual noise and foreground biases, whereas our proposed inverse-variance foreground subtraction eliminates noise and foreground biases, gives smaller error bars, and produces less correlated measurements of the power spectrum. We also numerically confirm the intuitive belief in the literature that 21 cm foreground subtraction is best done using frequency rather than angular information.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Sensitivity of neutrinos to the supernova turbulence power spectrum: Point source statistics

The neutrinos emitted from the proto-neutron star created in a core-collapse supernova must run through a significant amount of turbulence before exiting the star. Turbulence can modify the flavor evolution of the neutrinos imprinting itself upon the signal detected here at Earth. The turbulence effect upon individual neutrinos, and the correlation between pairs of neutrinos, might exhibit sensitivity to the power spectrum of the turbulence, and recent analysis of the turbulence in a two-dimensional hydrodynamical simulation of a core-collapse supernova indicates the power spectrum may not be the Kolmogorov 5 /3 inverse power law as has been previously assumed. In this paper we study the effect of non-Kolmogorov turbulence power spectra upon neutrinos from a point source as a function of neutrino energy and turbulence amplitude at a fixed postbounce epoch. We find the two effects of turbulence upon the neutrinos—the distorted phase effect and the stimulated transitions—both possess strong and weak limits in which dependence upon the power spectrum is absent or evident, respectively. Furthermore, since neutrinos of a given energy will exhibit these two effects at different epochs of the supernova each with evolving strength, we find there is sensitivity to the power spectrum present in the neutrino burst signal from a Galactic supernova.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Galaxy power spectrum in redshift space: Combining perturbation theory with the halo model

Theoretical modeling of the redshift-space power spectrum of galaxies is crucially important to correctly extract cosmological information from galaxy redshift surveys. The task is complicated by the nonlinear biasing and redshift space distortion (RSD) effects, which change with halo mass, and by the wide distribution of halo masses and their occupations by galaxies. One of the main modeling challenges is the existence of satellite galaxies that have both radial distribution inside the halos and large virial velocities inside halos, a phenomenon known as the Finger-of-God (FoG) effect. We present a model for the redshift-space power spectrum of galaxies in which we decompose a given galaxy sample into central and satellite galaxies and relate different contributions to the power spectrum to 1-halo and 2-halo terms in a halo model. Our primary goal is to ensure that any parameters that we introduce have physically meaningful values, and are not just fitting parameters. For the lowest order 2-halo terms we use the previously developed RSD modeling of halos in the context of distribution function and perturbation theory approach. This term needs to be multiplied by the effect of radial distances and velocities of satellites inside the halo. To this one needs to add the 1-halo terms, which are nonperturbative. We show that the real space 1-halo terms can be modeled as almost constant, with the finite extent of the satellites inside the halo inducing a small k 2 R 2 term over the range of scales of interest, where R is related to the size of the halo given by its halo mass. Furthermore, we adopt a similar model for FoG in redshift space, ensuring that FoG velocity dispersion is related to the halo mass. For FoG k 2 type expansions do not work over the range of scales of interest and FoG resummation must be used instead. We test several simple damping functions to model the velocity dispersion FoG effect. Applying the formalism to mock galaxies modeled after the “CMASS” sample of the BOSS survey, we find that our predictions for the redshift-space power spectra are accurate up to k ≃ 0.4 h Mpc –1 within 1% if the halo power spectrum is measured using N-body simulations and within 3% if it is modeled using perturbation theory.

79 ASTRONOMY AND ASTROPHYSICS↗

Tensions between direct measurements of the lens power spectrum from Planck data

We apply a recently developed method to directly measure the gravitational lensing power spectrum from CMB power spectra to the Planck satellite data. This method allows us to analyze the tension between the temperature power spectrum and lens reconstruction in a model independent way. Even when allowing for arbitrary variations in the lensing power spectrum, the tension remains at the 2.4σ level. By separating the lensing and unlensed high redshift information in the CMB power spectra, we also show that under ΛCDM the two are in tension at a similar level whereas the unlensed information is consistent with lensing reconstruction. These anomalies are driven by the smoother acoustic peaks relative to ΛCDM at ℓ ~1250-1500. Both tensions relax slightly when polarization data are considered. This technique also isolates the one combination of the lensing power spectrum multipoles that the Planck CMB power spectra currently constrain and can be straightforwardly generalized to future data when CMB power spectra constrain multiple aspects of lensing which are themselves correlated with lensing reconstruction

79 ASTRONOMY AND ASTROPHYSICS↗

Preequilibrium Asymmetries in the Pu 239 ( n , f ) Prompt Fission Neutron Spectrum

The physical properties of neutrons emitted from neutron-induced fission are fundamental to our understanding of nuclear fission. However, while state-of-the-art fission models still incorporate isotropic fission neutron spectra, it is believed that the preequilibrium prefission component of these spectra is strongly anisotropic. The lack of experimental guidance on this feature has not motivated incorporation of anisotropic neutron spectra in fission models, though any significant anisotropy would impact descriptions of a fissioning system. In the present work, an excess of counts at high energies in the fission neutron spectrum of 239 Pu is clearly observed and identified as an excess of the preequilibrium prefission distribution above the postfission neutron spectrum. This excess is separated from the underlying postfission neutron spectrum, and its angular distribution is determined as a function in incident neutron energy and outgoing neutron detection angle. Comparison with neutron scattering models provides the first experimental evidence that the preequilibrium angular distribution is uncorrelated with the fission axis. The results presented here also impact the interpretation of several influential prompt fission neutron spectrum measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the Antineutrino Spectrum from U 235 Fission at HFIR with PROSPECT

This Letter reports the first measurement of the 235 U ν¯ e energy spectrum by PROSPECT, the Precision Reactor Oscillation and Spectrum experiment, operating 7.9m from the 85MW th highly-enriched uranium (HEU) High Flux Isotope Reactor. With a surface-based, segmented detector, PROSPECT has observed 31678 ± 304 (stat.) ν¯ e -induced inverse beta decays (IBD), the largest sample from HEU fission to date, 99% of which are attributed to 235 U. Despite broad agreement, comparison of the Huber 235 U model to the measured spectrum produces a χ 2 /ndf = 51.4/31, driven primarily by deviations in two localized energy regions. As a result, the measured 235 U spectrum shape is consistent with a deviation relative to prediction equal in size to that observed at low-enriched uranium power reactors in the ν¯ e energy region of 5-7MeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Direct Measurement of the Nickel Spectrum in Cosmic Rays in the Energy Range from 8.8 GeV/$\mathcal{n}$ to 240 GeV/$\mathcal{n}$ with CALET on the International Space Station

The relative abundance of cosmic ray nickel nuclei with respect to iron is by far larger than for all other transiron elements; therefore it provides a favorable opportunity for a low background measurement of its spectrum. Since nickel, as well as iron, is one of the most stable nuclei, the nickel energy spectrum and its relative abundance with respect to iron provide important information to estimate the abundances at the cosmic ray source and to model the Galactic propagation of heavy nuclei. However, only a few direct measurements of cosmic-ray nickel at energy larger than ~ 3 GeV/n are available at present in the literature, and they are affected by strong limitations in both energy reach and statistics. In this Letter, we present a measurement of the differential energy spectrum of nickel in the energy range from 8.8 to 240 GeV/n , carried out with unprecedented precision by the Calorimetric Electron Telescope (CALET) in operation on the International Space Station since 2015. The CALET instrument can identify individual nuclear species via a measurement of their electric charge with a dynamic range extending far beyond iron (up to atomic number Z = 40 ). The particle’s energy is measured by a homogeneous calorimeter (1.2 proton interaction lengths, 27 radiation lengths) preceded by a thin imaging section (3 radiation lengths) providing tracking and energy sampling. This Letter follows our previous measurement of the iron spectrum [O. Adriani et al. (CALET Collaboration), Phys. Rev. Lett. 126, 241101 (2021).], and it extends our investigation on the energy dependence of the spectral index of heavy elements. It reports the analysis of nickel data collected from November 2015 to May 2021 and a detailed assessment of the systematic uncertainties. In the region from 20 to 240 GeV/n our present data are compatible within the errors with a single power law with spectral index -2.51 ± 0.07 .

79 ASTRONOMY AND ASTROPHYSICS↗

Scheduled Sequential Compressed Spectrum Sensing for Wideband Cognitive Radios

The support for high data rate applications with the cognitive radio technology necessitates wideband spectrum sensing. However, it is costly to apply long-term wideband sensing and is especially difficult in the presence of uncertainty, such as high noise, interference, outliers, and channel fading. In this paper, we propose scheduling of sequential compressed spectrum sensing which jointly exploits compressed sensing (CS) and sequential periodic detection techniques to achieve more accurate and timely wideband sensing. Instead of invoking CS to reconstruct the signal in each period, our proposed scheme performs backward grouped-compressed-data sequential probability ratio test (backward GCD-SPRT) using compressed data samples in sequential detection, while CS recovery is only pursued when needed. This method on one hand significantly reduces the CS recovery overhead, and on the other takes advantage of sequential detection to improve the sensing quality. Furthermore, we propose (a) an in-depth sensing scheme to accelerate sensing decision-making when a change in channel status is suspected, (b) a block-sparse CS reconstruction algorithm to exploit the block sparsity properties of wide spectrum, and (c) a set of schemes to fuse results from the recovered spectrum signals to further improve the overall sensing accuracy. Finally, extensive performance evaluation results show that our proposed schemes can significantly outperform peer schemes under sufficiently low SNR settings.

42 ENGINEERING↗

Characterization of imaging performance in differential phase contrast CT compared with the conventional CT: Spectrum of noise equivalent quanta NEQ(k)

Purpose: Differential phase contrast CT (DPC-CT) is emerging as a new technology to improve the contrast sensitivity of conventional attenuation-based CT. The noise equivalent quanta as a function over spatial frequency, i.e., the spectrum of noise equivalent quanta NEQ(k), is a decisive indicator of the signal and noise transfer properties of an imaging system. In this work, we derive the functional form of NEQ(k) in DPC-CT. Via system modeling, analysis, and computer simulation, we evaluate and verify the derived NEQ(k) and compare it with that of the conventional attenuation-based CT. Methods: The DPC-CT is implemented with x-ray tube and gratings. The x-ray propagation and data acquisition are modeled and simulated through Fresnel and Fourier analysis. A monochromatic x-ray source (30 keV) is assumed to exclude any system imperfection and interference caused by scatter and beam hardening, while a 360 Degree-Sign full scan is carried out in data acquisition to avoid any weighting scheme that may disrupt noise randomness. Adequate upsampling is implemented to simulate the x-ray beam's propagation through the gratings G{sub 1} and G{sub 2} with periods 8 and 4 {mu}m, respectively, while the intergrating distance is 193.6 mm (1/16 of the Talbot distance). The dimensions of the detector cell for data acquisition are 32 Multiplication-Sign 32, 64 Multiplication-Sign 64, 96 Multiplication-Sign 96, and 128 Multiplication-Sign 128 {mu}m{sup 2}, respectively, corresponding to a 40.96 Multiplication-Sign 40.96 mm{sup 2} field of view in data acquisition. An air phantom is employed to obtain the noise power spectrum NPS(k), spectrum of noise equivalent quanta NEQ(k), and detective quantum efficiency DQE(k). A cylindrical water phantom at 5.1 mm diameter and complex refraction coefficient n= 1 -{delta}+i{beta}= 1 -2.5604 Multiplication-Sign 10{sup -7}+i1.2353 Multiplication-Sign 10{sup -10} is placed in air to measure the edge transfer function, line spread function and then modulation transfer function MTF(k), of both DPC-CT and the conventional attenuation-based CT. The x-ray flux is set at 5 Multiplication-Sign 10{sup 6} photon/cm{sup 2} per projection and observes the Poisson distribution, which is consistent with that of a micro-CT for preclinical applications. Approximately 360 regions, each at 128 Multiplication-Sign 128 matrix, are used to calculate the NPS(k) via 2D Fourier transform, in which adequate zero padding is carried out to avoid aliasing in noise. Results: The preliminary data show that the DPC-CT possesses a signal transfer property [MTF(k)] comparable to that of the conventional attenuation-based CT. Meanwhile, though there exists a radical difference in their noise power spectrum NPS(k) (trait 1/|k| in DPC-CT but |k| in the conventional attenuation-based CT) the NEQ(k) and DQE(k) of DPC-CT and the conventional attenuation-based CT are in principle identical. Conclusions: Under the framework of ideal observer study, the joint signal and noise transfer property NEQ(k) and detective quantum efficiency DQE(k) of DPC-CT are essentially the same as those of the conventional attenuation-based CT. The findings reported in this paper may provide insightful guidelines on the research, development, and performance optimization of DPC-CT for extensive preclinical and clinical applications in the future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TH-A-19A-07: The Effect of Particle Tracking Step Size Limit On Monte Carlo- Computed LET Spectrum of Therapeutic Proton Beams

Purpose: To investigate the effect of charged particle tracking step size limit in the determination of the LET spectrum of therapeutic proton beams using Monte Carlo simulations. Methods: The LET spectra at different depths in a water phantom from a 79.7 MeV spot-scanning proton beam were calculated using Geant4. Five different tracking step limits 0.5 mm, 0.1 mm, 0.05 mm, 0.01 mm and 1 μm were adopted. The field size was set to 10×10 cm{sup 2} on the isocenter plane. A 40×40×6 cm{sup 3} water phantom was modelled as the irradiation target. The voxel size was set to 1×1×0.5 mm{sup 3} to obtain high resolution results. The LET spectra were scored ranging from 0.01 keV/μm to 10{sup 4}keV/μm in the logarithm scale. In addition, the proton energy spectra at different depths were also scored. Results: The LET spectra calculated using different step size limits were compared at four depths along the Bragg curve. At any depths, the spread of the LET spectra increases with the decrease of step size limit. In the dose buildup region (z = 1.9 cm) and in the region proximal to the Bragg peak (z = 3.95 cm), the frequency mean LET does not vary with decreasing step size limit. At Bragg peak (z = 4.75 cm) and in the distal edge (z = 4.85 cm), frequency mean LET decreases with decreasing step size limit. The energy spectrum at any specified depths does not vary with the step size limit. Conclusion: The calculated LET has a spectral distribution rather than a single value at any depths along the Bragg curve and the spread of the computed spectrum depends on the tracking step limit. Incorporating the LET spectrum distribution into the robust IMPT optimization plan may provide more accurate biological dose distribution than using the dose- or fluence-averaged LET. NIH Program Project Grant P01CA021239.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-557: Monte Carlo Modeling of Philips RT-250 Orthovoltage Unit for Beam Spectrum Modulation

Purpose: To develop and validate a Monte Carlo (MC) model of a Phillips RT-250 orthovoltage unit to test various beam spectrum modulation strategies for in vitro/vivo studies. A model of this type would enable the production of unconventional beams from a typical orthovoltage unit for novel therapeutic applications such as gold nanoparticle-aided radiotherapy. Methods: The MCNP5 code system was used to create a MC model of the head of RT-250 and a 30 × 30 × 30 cm{sup 3} water phantom. For the x-ray machine head, the current model includes the vacuum region, beryllium window, collimators, inherent filters and exterior steel housing. For increased computational efficiency, the primary x-ray spectrum from the target was calculated from a well-validated analytical software package. Calculated percentage-depth-dose (PDD) values and photon spectra were validated against experimental data from film and Compton-scatter spectrum measurements. Results: The model was validated for three common settings of the machine namely, 250 kVp (0.25 mm Cu), 125 kVp (2 mm Al), and 75 kVp (2 mm Al). The MC results for the PDD curves were compared with film measurements and showed good agreement for all depths with a maximum difference of 4 % around dmax and under 2.5 % for all other depths. The primary photon spectra were also measured and compared with the MC results showing reasonable agreement between the two, validating the input spectra and the final spectra as predicted by the current MC model. Conclusion: The current MC model accurately predicted the dosimetric and spectral characteristics of each beam from the RT-250 orthovoltage unit, demonstrating its applicability and reliability for beam spectrum modulation tasks. It accomplished this without the need to model the bremsstrahlung xray production from the target, while significantly improved on computational efficiency by at least two orders of magnitude. Supported by DOD/PCRP grant W81XWH-12-1-0198.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Noise power spectrum of the fixed pattern noise in digital radiography detectors

Purpose: The fixed pattern noise in radiography image detectors is caused by various sources. Multiple readout circuits with gate drivers and charge amplifiers are used to efficiently acquire the pixel voltage signals. However, the multiple circuits are not identical and thus yield nonuniform system gains. Nonuniform sensitivities are also produced from local variations in the charge collection elements. Furthermore, in phosphor-based detectors, the optical scattering at the top surface of the columnar CsI growth, the grain boundaries, and the disorder structure causes spatial sensitivity variations. These nonuniform gains or sensitivities cause fixed pattern noise and degrade the detector performance, even though the noise problem can be partially alleviated by using gain correction techniques. Hence, in order to develop good detectors, comparative analysis of the energy spectrum of the fixed pattern noise is important. Methods: In order to observe the energy spectrum of the fixed pattern noise, a normalized noise power spectrum (NNPS) of the fixed pattern noise is considered in this paper. Since the fixed pattern noise is mainly caused by the nonuniform gains, we call the spectrum the gain NNPS. We first asymptotically observe the gain NNPS and then formulate two relationships to calculate the gain NNPS based on a nonuniform-gain model. Since the gain NNPS values are quite low compared to the usual NNPS, measuring such a low NNPS value is difficult. By using the average of the uniform exposure images, a robust measuring method for the gain NNPS is proposed in this paper. Results: By using the proposed measuring method, the gain NNPS curves of several prototypes of general radiography and mammography detectors were measured to analyze their fixed pattern noise properties. We notice that a direct detector, which is based on the a-Se photoconductor, showed lower gain NNPS than the indirect-detector case, which is based on the CsI scintillator. By comparing the gain NNPS curves of the indirect detectors, we could analyze the scintillator properties depending on the techniques for the scintillator surface processing. Conclusions: A robust measuring method for the NNPS of the fixed pattern noise of a radiography detector is proposed in this paper. The method can measure a stable gain NNPS curve, even though the fixed pattern noise level is quite low. From the measured gain NNPS curves, we can compare and analyze the detector properties in terms of producing the fixed pattern noise.

60 APPLIED LIFE SCIENCES↗