Search NASA⌕ Search

SEARCH · Search NASA

Results for “TIMING PROPERTIES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Time-resolved shadowgraphic study of femtosecond laser ablation of aluminum under different ambient air pressures

Femtosecond pulse laser ablation of aluminum under different ambient air pressures between 1 atm and 4 x 10{sup -4} Pa is investigated using a femtosecond time-resolved shadowgraphic method. It is observed that as the ambient air pressure decreases, the contact front becomes more and more distinct for a certain pressure range, demonstrating that the confinement effect of the ambient air to the ablated target material can play a critically important role in the laser ablation process. It is also found that the concentric and semicircular stripe pattern, which results from the diffraction of the probe beam by the expanding plume of a specific material state and is typically observed in the shadowgraphs for 1-2 ns delay time, gradually blurs and disappears while the ambient air pressure decreases from 1 atm to 7000 Pa. If a prepulse or a relatively large pulse pedestal exists before the main pulse, however, the stripe pattern can still be observed even though the ambient air pressure is 5 x 10{sup -4} Pa. It is thus inferred that what contributes to the formation of the unique stripe pattern is a mixture of the ejected target material and ionized background gas induced by the femtosecond laser ablation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dynamics of electron solvation in I{sup -}(CH{sub 3}OH){sub n} clusters (4 {<=}n{<=} 11)

The dynamics of electron solvation following excitation of the charge-transfer-to-solvent precursor state in iodide-doped methanol clusters, I{sup -}(CH{sub 3}OH){sub n=4-11}, are studied with time-resolved photoelectron imaging. This excitation produces a I{sup ...}(CH{sub 3}OH){sub n}{sup -} cluster that is unstable with respect to electron autodetachment and whose autodetachment lifetime increases monotonically from {approx}800 fs to 85 ps as n increases from 4 to 11. The vertical detachment energy (VDE) and width of the excited state feature in the photoelectron spectrum show complex time dependence during the lifetime of this state. The VDE decreases over the first 100-400 fs, then rises exponentially to a maximum with a {approx}1 ps time constant, and finally decreases by as much as 180 meV with timescales of 3-20 ps. The early dynamics are associated with electron transfer from the iodide to the methanol cluster, while the longer-time changes in VDE are attributed to solvent reordering, possibly in conjunction with ejection of neutral iodine from the cluster. Changes in the observed width of the spectrum largely follow those of the VDEs; the dynamics of both are attributed to the major rearrangement of the solvent cluster during relaxation. The relaxation dynamics are interpreted as a reorientation of at least one methanol molecule and the disruption and formation of the solvent network in order to accommodate the excess charge.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Space- and time-resolved characterization of nanosecond time scale discharge at pressurized gas

The phenomenon of ultra-fast electrical gas breakdown was investigated. Nanosecond high-voltage pulses with durations of 1 and 5 ns and amplitudes of 100 and 200 kV, respectively, were used to study the parameters of the discharge in a pressured (1-7) x 10{sup 5} Pa air-filled gap. The development of the discharge and the plasma propagation velocity was examined using optical fast frame imaging. The generation of runaway electrons in the breakdown process was confirmed by electron imaging and time-resolved x-ray diagnostics. Runaway electron beam energy distribution was obtained for a 1 ns duration high-voltage pulse. The origin and the role of runaway electrons in the discharge initiation are also discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Energetic Ion Beam Production by a Low-Pressure Plasma Focus Discharge

Energetic ion beam emissions in a 3 kJ Mather type plasma focus operating at low-pressure regime are investigated. Deuterium gas is used and the discharge is operated in a low-pressure regime of below 1 mbar. Formation of the current sheath during the breakdown phase at the back wall is assisted by a set delayed trigger pulse. Energetic and intense ion beams with good reproducibility have been obtained for the operating pressure ranging from 0.05 mbar to 0.5 mbar. Deuteron beam is determined by time resolved measurement by making use of three biased ion collectors placed at the end on direction. The average energies of deuteron beams are resolved by using time-of flight method. Correlation between the ion emissions and the current sheath dynamics is also discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fiber-coupled Luminescence Dosimetry in Therapeutic and Diagnostic Radiology

Fiber-coupled luminescence dosimetry is an emerging technology with several potentially attractive features of relevance for uses in therapeutic and diagnostic radiology: direct water equivalence (i.e. no significant perturbation of the radiation field in a water phantom or a patient), sub-mm detector size, high dynamic range (below a mGy to several Gy), microsecond time resolution, and absence of electrical wires or other electronics in the dosimeter probe head. Fiber-coupled luminescence dosimetry systems typically consist of one or more small samples of phosphor, e.g. a mg of plastic scintillator, attached to 10-20 m long optical fiber cables of plastic. During irradiation, each dosimeter probe spontaneously emits radioluminescence (RL) in proportion to the dose rate. The luminescence intensity can be detected with photomultiplier tubes, CCD cameras or other highly sensitive photodetectors. Some crystalline phosphors, such as carbon-doped aluminium oxide (Al{sub 2}O{sub 3}:C) have the ability to store charge produced in the crystal during irradiation. The stored charge may later be released by fiber-guided laser light under emission of so-called optically stimulated luminescence (OSL). The OSL signal therefore reflects the passively integrated dose. In contrast to thermoluminescence dosimetry, fiber-coupled OSL dosimetry may be performed in vivo while the dosimeter is still in the patient. Within the last few years, several improvements and new applications of these techniques have been published, and the objective of this review is to provide an introduction to this field and to outline some of these new results. Emphasis will be given to applications in medical dosimetry such as in vivo real-time dose verification in brachytherapy and methods aimed for improved quality assurance of linear accelerators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-resolved gas temperature evolution in pulsed Ar-N{sub 2} microwave discharge

Temporal evolution of the gas temperature (T{sub g}) in a pulsed microwave surfaguide discharge is studied by measuring the N{sub 2} rotational temperature. We found that at high power applied per pulse, gas temperature grows linearly, and saturates after about 150 {mu}s. This effect is absent at low power values, or at short pulse durations. Observed T{sub g} behavior correlates with time-resolved measurements of the N{sub 2} vibrational temperature, as well as with N emission lines. Consequently, T{sub g} time behavior was related to N atoms production in plasma. Using obtained T{sub g} growth rates, the effective power used for plasma heating is determined.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Highly Efficient Neutron Veto Using Boron-Loaded Liquid Scintillator

By surrounding a dark matter detector with a layer of boron-loaded liquid scintillator, a highly efficient neutron veto can be produced. In Monte Carlo studies, a one meter thick layer of scintillator has a veto efficiency greater than 99.5% for nuclear recoil events induced by radiogenic neutrons, and a veto efficiency of more than 95% for nuclear recoil events produced by cosmogenic neutrons. The use of boron-loaded scintillator both reduces the veto-induced dead time by decreasing the neutron capture time and allows high neutron detection efficiency to be achieved in a relatively compact geometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-resolved resonant soft x-ray diffraction with free-electron lasers: Femtosecond dynamics across the Verwey transition in magnetite

Resonant soft x-ray diffraction (RSXD) with femtosecond (fs) time resolution is a powerful tool for disentangling the interplay between different degrees of freedom in strongly correlated electron materials. It allows addressing the coupling of particular degrees of freedom upon an external selective perturbation, e.g., by an optical or infrared laser pulse. Here, we report a time-resolved RSXD experiment from the prototypical correlated electron material magnetite using soft x-ray pulses from the free-electron laser FLASH in Hamburg. We observe ultrafast melting of the charge-orbital order leading to the formation of a transient phase, which has not been observed in equilibrium.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Time-resolved photoelectron spectroscopy of coupled electron-nuclear motion

We investigate pump-probe electron detachment spectroscopy in a model system which is ideally suited to study coupled electronic and nuclear wave-packet dynamics. Time-resolved photoelectron spectra are calculated within the adiabatic approximation and a discretization of the detachment continuum. These spectra are compared to those which derive from a non-Born-Oppenheimer description and a numerically exact treatment of the detachment process. In this way it is possible to identify the influence of non-adiabatic effects on the spectra in a systematic way and also to test commonly applied approximations.

74 ATOMIC AND MOLECULAR PHYSICS↗

X-Ray Measurements Of A Thermo Scientific P385 DD Neutron Generator

Idaho National Laboratory is experimenting with electrical neutron generators, as potential replacements for californium-252 radioisotopic neutron sources in its PINS prompt gamma-ray neutron activation analysis (PGNAA) system for the identification of military chemical warfare agents and explosives. In addition to neutron output, we have recently measured the x-ray output of the Thermo Scientific P385 deuterium-deuterium neutron generator. X rays are a normal byproduct from neutron generators, but depending on their intensity and energy, x rays can interfere with gamma rays from the object under test, increase gamma-spectrometer dead time, and reduce PGNAA system throughput. The P385 x-ray energy spectrum was measured with a high-purity germanium (HPGe) detector, and a broad peak is evident at about 70 keV. To identify the source of the x rays within the neutron generator assembly, it was scanned by collimated scintillation detectors along its long axis. At the strongest x-ray emission points, the generator also was rotated 60 deg. between measurements. The scans show the primary source of x-ray emission from the P385 neutron generator is an area 60 mm from the neutron production target, in the vicinity of the ion source. Rotation of the neutron generator did not significantly alter the x-ray count rate, and its x-ray emission appears to be axially symmetric. A thin lead shield, 3.2 mm (1/8 inch) thick, reduced the 70-keV generator x rays to negligible levels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Digital Electronics For The Versatile Array Of Neutron Detectors At Low Energies

A {chi}{sup 2} minimization algorithm has been developed to extract sub-sampling-time information from digitized waveforms, to be used to instrument the future Versatile Array of Neutron Detectors at Low energies. The algorithm performance has been characterized with a fast Arbitrary Function Generator, obtaining time resolution better than 1 ns for signals of amplitudes between 50 mV and 1V, with negligible walk in the whole range. The proof-of-principle measurement of the beta-delayed neutron emission from {sup 89}Br indicates a resolution of 1 ns can be achieved in realistic experimental conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-resolved spectroscopic diagnostic of laser-induced plasma on germanium targets

Time-resolved optical emission measurements have been made in laser-induced plasma plumes following CO{sub 2} pulsed-laser (10.591 {mu}m, 64 ns and intensity from 0.27 to 4.9 GW cm{sup -2}) irradiation of germanium targets. The temporal behavior of Ge atoms and ionized excited species Ge{sup 3+}, Ge{sup 2+}, and Ge{sup +} is reported. The results show a faster decay of the continuum emission and Ge{sup 3+}, Ge{sup 2+} ionic species than in the case of Ge{sup +} and neutral Ge atoms. The velocity distributions for Ge{sup 3+}, Ge{sup 2+}, Ge{sup +}, and Ge species are obtained from time-of-flight measurements. Electron density in the laser-induced plasma was estimated from the analysis of spectral data at various times from the CO{sub 2} laser pulse incidence. From the intensity decay with the delay time for Ge{sup +}, Ge{sup 2+}, and Ge{sup 3+}, we estimated the three-body electron-ion recombination rate constants for these species.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dynamics of laser-induced surface phase explosion in silicon

Time-resolved ultrasonic studies revealed a second, delayed ablative pressure pulse after the first primary plasma pressure pulse in a silicon wafer irradiated by a UV nanosecond laser. The intensity-dependent delay time for the second pulse indicates the existence of a corresponding intensity-dependent homogeneous vapor bubble nucleation time in the superheated molten silicon prior to its phase explosion and ablative removal, since the integral pressure correlates with the ablation rate. A transient hot ablative plasma with calculated peak temperature {approx}30-90 eV and pressure {approx}20-110 GPa is suggested to superheat the bulk silicon via short-wavelength recombination and Bremsstrahlung emission.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Spectroscopic Study of (two-dimensional) Molecule-based Magnets: [MII(TCNE)(NCMe)2][SbF6] (M = Fe Mn Ni)

The M-[TCNE] (M = 3d metal; TCNE = tetracyanoethylene) system is one of the most interesting classes of molecule-based magnets, exhibiting a plethora of compositions and structures (inorganic polymer chains, 2D layers, 3D networks, and amorphous solids) with a wide range of magnetic ordering temperatures (up to 400 K). A systematic study of vibrational (both infrared and, for the first time, Raman) properties of the family of new TCNE-based magnets of M{sup II}(TCNE) (NCMe){sub 2}[SbF{sub 6}] [M = Mn, Fe, Ni] composition is discussed in conjunction with their magnetic behavior and newly resolved crystal structures. The vibrational properties of the isolated TCNE{sup {sm_bullet}-} anion in the paramagnetic Bu{sub 4}N [TCNE{sup {sm_bullet}-}] salt and recently characterized 2D layered magnet Fe{sup II}(TCNE)(NCMe){sub 2}[FeCl{sub 4}] are also reported for comparison. Additionally, a linear correlation between {nu}{sub c=c} (a{sub g}) frequency of the TCNE ligand and its formal charge Z (the spin density on the {pi}* orbital), Z = [1571 - {nu}{sub C=C} (ag)]/154.5 [e], is presented. It is shown that monitoring Z by Raman spectroscopy is of great use in providing information that allows understanding the peculiarity of the superexchange interaction in M-[TCNE] magnets and establishing the structure-magnetic properties correlations in this class of magnetic material.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Shortening x-ray pulses for pump-probe experiments at synchrotrons

We implemented an experimental scheme for ultrafast x-ray diffraction at storage rings based on a laser-driven Bragg-switch that shortens the x-ray pulses emitted from an undulator. The increased time-resolution is demonstrated by observing changes of intensity, position and width of the diffraction peaks of a La{sub 0.7}Sr{sub 0.3}MnO{sub 3}/SrTiO{sub 3} superlattice sample after optical excitation, i.e., by quantitatively measuring the propagation of an expansion wave through the sample. These experimental transients with timescales of 35 to 60 ps evidence a reduction of the x-ray pulse duration by a factor of two.

36 MATERIALS SCIENCE↗

Kinetic simulation of a nanosecond-pulsed hydrogen microdischarge

The electron dynamics in a nanosecond-pulsed microdischarge in high pressure hydrogen gas is investigated space and time resolved by particle-in-cell simulations. The discharge is driven by a 10 ns voltage pulse with a peak of 1.3 kV followed by an approximately constant voltage of 300 V during 150 ns. The time resolved current, electric field, electron density, and spatio-temporal excitation rates are compared to experimental and modeling results under identical discharge conditions. Via this synergistic approach, the development of the discharge and the different phases of distinct electron dynamics are identified and understood.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fermi GBM Observations of Terrestrial Gamma-ray Flashes

Terrestrial Gamma-ray Flashes are short pulses of energetic radiation associated with thunderstorms and lightning. While the Gamma-ray Burst Monitor (GBM) on Fermi was designed to observe gamma-ray bursts, its large BGO detectors are excellent for observing TGFs. Using GBM, TGF pulses are seen to either be symmetrical or have faster rise time than fall times. Some TGFs are resolved into double, partially overlapping pulses. Using ground-based radio observations of lightning from the World Wide Lightning Location Network (WWLLN), TGFs and their associated lightning are found to be simultaneous to {approx_equal}40 {mu} s. The lightning locations are typically within 300 km of the sub-spacecraft point.

79 ASTRONOMY AND ASTROPHYSICS↗

The {sup 237}Np(n,f) cross section at the CERN n-TOF facility

The {sup 237}Np(n,f) cross sections have been measured at the n-TOF facility relative to the {sup 235}U and {sup 238}U fission cross sections. The n-TOF spallation neutron source at CERN is characterized by a high intensity flux, an excellent time resolution and an extensive neutron energy range (from eV to GeV). A fast ionization chamber was used as a fission fragment detector with efficiency better than 97%. Preliminary {sup 237}Np(n,f) cross sections have been deduced in the energy range from 20 keV to 10 MeV and are found in good agreement with data from literature.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗