Modeling a generic TRISO-fueled heat pipe microreactor using SCALE: Depletion, transportation criticality, and shielding

This paper demonstrates the applicability of the SCALE code system to tristructural-isotropic (TRISO)-fueled heat pipe microreactors through depletion, transportation criticality, and shielding analyses of a generic reference design. The study conducted supports US Nuclear Regulatory Commission code readiness efforts for advanced non–light-water reactor technologies and is intended as a code capability demonstration rather than as an optimization of a specific microreactor design. The modeled reactor employs high-assay low-enriched uranium (HALEU) uranium oxycarbide (UCO) TRISO fuel and beryllium oxide (BeO) reflectors and operates at 7.5 MWth with a nominal lifetime of about 3 effective full power years. Representative cases for fresh and irradiated cores were selected to exercise SCALE methods relevant to reactor operation and post-irradiation transport. The discharged-core decay heat is approximately 6% of operating power immediately after shutdown. Transportation criticality calculations show that internal water ingress is the dominant reactivity effect, with fully flooded fresh core and irradiated core configurations remain above the subcriticality criterion, even with the available control mechanisms. Shielding calculations for a simplified transportation package indicate that normal-condition dose rates are governed mainly by shielding thickness and cooling time, whereas the breached hypothetical accident case is governed primarily by cooling time. Overall, the study shows that SCALE supports depletion, transportation criticality, and shielding evaluations efficiently for TRISO-fueled heat pipe microreactors within a single code system.

Criticality

Pinning ångström-size solid ionic channels for rare-earth element separation

High-purity rare-earth elements are essential for modern technologies, yet current solvent extraction processes are energy-intensive and environmentally harmful because of inadequate selectivity and ligand toxicity. Although combining size exclusion and binding affinity can improve lanthanide separation, the role of long-range confinement remains underexplored. Here we report lanthanide separation in aqueous systems using extremely confined manganese oxide solid ionic channels with optimized layer spacing. Different lanthanides induce distinct solid-state phase transformations in manganese oxide, creating a strong driving force for separation. Two lanthanide groups, differing by ~1.4 Å in spacing, were identified and confirmed to be stable by density functional theory. The narrower confinement of heavier Group II lanthanides improves cross-group separation by increasing the dehydration barrier for lighter Group I lanthanides without inducing strong binding. Here, we further developed a strategy to pin the confinement dimensions and enhance same-group separation, increasing enrichment factors for La–Nd and La–Pr pairs from 1.6 ± 0.1 and 1.5 ± 0.1 to 5.4 ± 0.1 and 4.2 ± 0.1, respectively.

Chemical engineering

Proximal remote sensing: an essential tool for bridging the gap between high‐resolution ecosystem monitoring and global ecology

Summary A new proliferation of optical instruments that can be attached to towers over or within ecosystems, or ‘proximal’ remote sensing, enables a comprehensive characterization of terrestrial ecosystem structure, function, and fluxes of energy, water, and carbon. Proximal remote sensing can bridge the gap between individual plants, site‐level eddy‐covariance fluxes, and airborne and spaceborne remote sensing by providing continuous data at a high‐spatiotemporal resolution. Here, we review recent advances in proximal remote sensing for improving our mechanistic understanding of plant and ecosystem processes, model development, and validation of current and upcoming satellite missions. We provide current best practices for data availability and metadata for proximal remote sensing: spectral reflectance, solar‐induced fluorescence, thermal infrared radiation, microwave backscatter, and LiDAR. Our paper outlines the steps necessary for making these data streams more widespread, accessible, interoperable, and information‐rich, enabling us to address key ecological questions unanswerable from space‐based observations alone and, ultimately, to demonstrate the feasibility of these technologies to address critical questions in local and global ecology.

Plant Sciences

Why Perovskite Thermal Stress is Unaffected by Thin Contact Layers

Metal halide perovskite photovoltaics have emerged as a high efficiency, low-cost alternative that can potentially rival or enhance conventional silicon technology. Despite exceptional initial power conversion efficiencies, achieving compliance with international standards and widespread adoption requires further enhancements to their operational stability. Notably, addressing mechanical strain and stress in brittle perovskites has emerged as a pivotal approach to mitigate chemical degradation and improve reliability during thermal cycling. Here, in this study, a popularized strain engineering strategy is investigated in which a high coefficient of thermal expansion (CTE) hole transport layer (i.e., PDCBT) is cast onto inorganic perovskite (CsPbI 2 Br) at 100 °C. Contrary to previously published results, the X-ray diffraction (XRD):Sin 2 ψ and substrate curvature measurement techniques show that the hole transport layer has no discernible impact on perovskite strain. The accuracy of the XRD:Sin 2 ψ method for measuring strain is highlighted in contrast to an analysis based on shifts of single XRD peaks which can be influenced by multiple artifacts. The findings in this study are in accordance with mechanics theory: thin layers are unable to induce significant strain changes in perovskite thin films as the force they apply is negligible compared to that applied by a thick and stiff substrate.

14 SOLAR ENERGY

The SPT-deep Cluster Catalog: Sunyaev–Zel’dovich Selected Clusters from Combined SPT-3G and SPTpol Measurements over 100 Square Degrees

We present a catalog of 500 galaxy cluster candidates in the SPT-Deep field: a 100 deg$^{2}$ field that combines data from the SPT-3G and SPTpol surveys to reach noise levels of 3.0, 2.2, and 9.0 μK-arcmin at 95, 150, and 220 GHz, respectively. Candidates are selected via the thermal Sunyaev–Zel’dovich (SZ) effect with a minimum significance of ξ = 4.0, resulting in a catalog of purity ∼89%. Optical data from the Dark Energy Survey and infrared data from the Spitzer Space Telescope are used to confirm 442 cluster candidates. The clusters span 0.12 < z ≲ 1.8 and 1.0 × 10$^{14}$M$_{⊙}$/h$_{70}$ < M$_{500c}$ < 8.7 × 10$^{14}$M$_{⊙}$/h$_{70}$. The sample’s median redshift is 0.74, and the median mass is 1.7 × 10$^{14}$M$_{⊙}$/h$_{70}$; these are the lowest median mass and highest median redshift of any SZ-selected sample to date. We assess the effect of infrared emission from cluster member galaxies on cluster selection by performing a joint fit to the infrared dust and tSZ signals by combining measurements from SPT and overlapping submillimeter data from Herschel/SPIRE. We find that at high redshift (z > 1), the tSZ signal is reduced by $17.9_{−3.2}^{+3.8}$%$(3.8_{−0.7}^{+0.9}$%$)$ at 150 GHz (95 GHz) due to dust contamination. We repeat our cluster finding method on dust-nulled SPT maps and find the resulting catalog is consistent with the nominal SPT-Deep catalog, suggesting dust contamination does not significantly impact the SPT-Deep selection function; we attribute this lack of bias to the inclusion of the SPT 220 GHz band.

79 ASTRONOMY AND ASTROPHYSICS

Maximizing dynamic range and performance of anatase TiO 2 ECRAM through structure and programming

Here, in this study, we investigate the structure-dependent modulation characteristics of all-solid-state three-terminal electrochemical random-access memory (ECRAM) based on an anatase Li x TiO 2 channel. By directly comparing “asymmetric” and “symmetric” ECRAM device architectures, we reveal significant insight into the impact of a non-zero gate-drain open-circuit voltage and its influence on voltage vs. current-controlled gating. We also explore the impact of potentiation/depression write parameters on the symmetry, linearity, and dynamic range of the device response. Together, initial results from optimizing structure and programming approaches yielded unprecedented G max /G min ratios of >1,000 for ECRAM and hundreds of tunable memory states with excellent linearity and symmetry. Simulations based on these ECRAM devices further illustrate the promise of this analog memory technology, achieving near 2% classification error in the MNIST digit recognition benchmark for a range of training parameters compared to a theoretical best of 1.66% and outperforming other device models extracted from the literature.

AIHWKit

Selectivity mechanisms of ion intercalation in Prussian blue analogs

Prussian blue analogs (PBAs) are a family of materials with facile, reversible, and selective ion transport capability for various ions via electrochemical intercalation, owing to their vacancy structure. The large tunable compositional space of PBAs allows for manipulation of intercalation behavior and selectivity by controlling structural vacancy level through choice of transition metal centers and modifications to the synthesis process. However, a lack of understanding of the mechanisms of ion selectivity hinders the material’s design process. Here, for this work, we investigated the origins of ion selectivity using a model PBA, copper hexacyanoferrate, and focused on eight technologically and biologically prominent ions, for which we determined a sequence of selectivity: Rb + > K + > Na + > Ba 2+ > Sr 2+ ≈ Ca 2+ > Mg 2+ > Li + . We provide electrochemical, structural, and redox evidence of strong correlation between the ion identity, the dominant charge-compensating redox, and preferred occupancy site. Specifically, using synchrotron anomalous X-ray diffraction (AXRD), we reveal that monovalent ions exhibit significant association with the corner sites of the unit cell and iron redox, whereas divalent ions display affinity toward the center site with higher ratios of copper redox. Informed by selectivity results, we applied CuHCFe to Li purification and achieved 99.9% purity. Our findings demonstrate an approach to elucidating ion intercalation behavior in order to distinguish and manipulate material properties to optimize separation performance.

Prussian blue analog

Co-Location of Cellulosic Bioethanol and Alcohol-to-Jet (ATJ) Production Facilities for Targeted Scale-Up of Sustainable Aviation Fuel (SAF) Production

Achieving aerospace industry net-zero emissions by 2050 requires rapid scaling of sustainable aviation fuel (SAF) production. Leveraging existing infrastructure, proven technologies like Alcohol-to-Jet (ATJ), and low carbon intensity (CI) feedstocks (e.g., switchgrass and miscanthus) can support this transition and help achieve near-term emissions reduction targets. This study evaluates the implications of lignocellulosic ethanol biorefinery siting and integration with petroleum refineries to produce SAF across 1000 sites randomly sampled from areas suitable for perennial grasses in the U.S. rainfed region. To better understand the logistics of material transport and handoffs, we integrated models of biomass harvest, transport, ethanol, and ATJ production in a stochastic framework based on Monte Carlo simulations to characterize SAF minimum selling price (MSP) and carbon intensity (CI), considering site-specific parameters (e.g., feedstock production, transportation, taxes, incentives). The results indicate trade-offs between MSP and CI across locations, with median MSP ranging from 7.9 to 12.8 USD·gal −1 and CI from −9.7 to 39.4 gCO 2 e·MJ −1 . Despite high estimated decarbonization costs (580 USD·tonCO 2 e −1 ), our results indicate that site-specific deployment of ATJ with low-CI feedstocks can improve sustainability outcomes. The framework provides a systematic approach to assess cost and sustainability trade-offs across locations, considering the end-to-end supply chain and supporting an informed investment in SAF production.

09 BIOMASS FUELS

Influence of functional additives, fillers, and pigments on thermal and catalytic pyrolysis of polyethylene for waste plastic upcycling

Pyrolysis offers a relatively green and economical method to convert waste plastics into valuable chemicals and fuels without the need for harmful solvents, toxic chemicals, or costly high-pressure reactors. Despite its popularity among chemical upcycling technologies, industrial adoption suffers from feedstock heterogeneity, low-quality products, and catalyst deactivation. Most plastics in our daily lives are formulated with functional additives, fillers, and colorants. These additives remaining in end-of-life waste streams increase feedstock heterogeneity, creating a challenging issue in recycling plastics. Still, the potential impacts of additives on the chemical upcycling of plastics have been poorly understood. In this study, polyethylene compounded with a range of widely used additives (antioxidants, stabilizers, pigments, fillers, slip agents, and flame retardants) was subjected to both thermal pyrolysis and catalytic pyrolysis in different catalyst-to-feedstock contact modes. It showed that many inorganic additives, such as talc, kaolin, CaCO 3 , TiO 2 , carbon black, and zinc stearate, facilitated polymer decomposition during pyrolysis, increasing light hydrocarbons while also promoting aromatic and carbon residue formation. Conversely, antioxidants and stabilizers inhibited depolymerization, favoring heavier hydrocarbons. During catalytic pyrolysis with HZSM-5 zeolite, additives strongly enhanced aromatic and catalytic coke formation, especially when there was direct contact between plastics and catalysts. Although certain additives seem beneficial in the short term by promoting polymer cracking and improving the selectivity of aromatics, the transport of the additives and their degradation products and increased carbon coking can contaminate products, deactivate or modify catalysts, and foul reactors. These findings address a critical knowledge gap in effectively converting waste plastics via a greener route.

42 ENGINEERING

CatTestHub: A benchmarking database of experimental heterogeneous catalysis for evaluating advanced materials

The ability to quantitatively compare newly evolving catalytic materials and technologies is hindered by the widespread availability of catalytic data collected in a consistent manner. While certain catalytic chemistries have been widely studied across decades of scientific research, quantitative comparisons based on literature information is hindered by variability in reaction conditions, types of reported data, and reporting procedures. Here, we present CatTestHub, an open-access database dedicated to benchmarking experimental heterogeneous catalysis data. Combining systematically reported catalytic activity data for selected probe chemistries, with relevant material characterization and reactor configuration information, the database provides a collection of catalytic benchmarks for distinct classes of active site functionality. Through key choices in data access, availability, and traceability, CatTestHub seeks to balance the fundamental information needs of chemical catalysis and the FAIR data design principles. Details of the database architecture and the means through which to navigate it are presented, highlighting examples of catalytic insights readily drawn from the available benchmarking data. In its current iteration, CatTestHub spans over 250 unique experimental data points, collected over 24 solid catalysts, that facilitated the turnover of 3 distinct catalytic chemistries. Here, a roadmap is presented through which to expand the open-access platform that serves as a community wide benchmark, primarily through continuous addition of kinetic information on select catalytic systems by members of the heterogeneous catalysis community at large.

Benchmark

Physicochemical and biological characterization of a bispecific antibody in a CrossMab/KIH format that targets EGFR and VEGF-A

Introduction Bispecific antibodies (BsAbs) are a class of antibody therapeutics engineered in various molecular formats to bind two distinct antigens and potentially mediate multiple biological effects. These molecular formats are tailored to mediate specific mechanisms of action and possess unique physicochemical and biological properties that are necessary to assure product quality. In ovarian cancer (OC), both EGFR- and VEGF-A-mediated signaling pathways are often upregulated and cooperate to promote tumor growth and angiogenesis. Thus, inhibiting of EGFR- and VEGF-A pathways with a BsAb may provide synergistic anti-tumor activity. Methods Using publicly available sequences and applying immunoglobulin domain crossover (CrossMab) and knobs-into-holes (KIH) technologies, we generated a BsAb to simultaneously bind EGFR and VEGF-A (designated as anti-EGFR/VEGF-A BsAb). This BsAb served as a model for physiochemical and biological characterization of quality attributes that would be critical for the BsAb’s mechanisms of action. Our goal was to gain fundamental insights into BsAbs designed to target a receptor with one arm and a soluble ligand with the other, to support bioassay development and inform quality control strategies. Results Our data demonstrated that the CrossMab/KIH platform successfully produced a correctly assembled BsAb during cell culture. Characterization confirmed that the anti-EGFR/VEGF-A BsAb bound both EGFR and VEGF-A with comparable activity and affinity to the respective parental monoclonal antibodies. Functionally, the BsAb disrupted both EGF/EGFR and VEGF-A/VEGFR2 signaling pathways in OC and human umbilical vein endothelial cell (HUVEC) models. Furthermore, the BsAb effectively blocked angiogenic signaling driven by VEGF-A secreted from OC cells in a paracrine manner. Discussion Based on the combinatorial mechanism of action and our characterization findings, we concluded that two or more bioassays may be needed to accurately assess the activity of both arms of this type of BsAb.

Immunology

Envelope-driven comfort risk in residential demand response

Residential demand response (DR) is a valuable resource for grid reliability, but remains challenging because the highly heterogeneous residential building stock leads to widely varying and hard-to-predict load and comfort responses during DR events. Although prior research has estimated the technical potential of DR-capable technologies for achieving energy demand savings, little is known about how they affect thermal comfort. In particular, it remains unclear how indoor thermal conditions due to DR depend on the thermal envelope characteristics of the housing stock. To address this gap, this study provides a systematic, location-specific assessment of indoor thermal performance during DR-events across the US housing stock using both typical DR weather data and detailed building metadata. We evaluate how envelope characteristics influence indoor temperatures during realistic simulated summer and winter DR events across 37 US locations, applying both temperature threshold and rate of temperature change criteria to estimate region-level probabilities of discomfort. Additionally, we show the impact of distinct weather patterns that intensify or abate thermal stress on comfort outcomes. Results show a near-universal overheating risk in summer DR events, where comfort outcomes are strongly influenced by rapid risk of comfort violations. In contrast, overall winter DR discomfort risk is lower, risk escalation is more gradual and shows greater sensitivity to event duration. These findings offer a data-driven quantification of comfort risk across diverse climates and building envelopes, demonstrating the need for region-specific DR scheduling and discomfort mitigation strategies tailored to local weather patterns and the performance of existing residential buildings.

Demand response

Refractory-based thermal energy storage for industrial process heat: one-dimensional modeling, control, and optimization

The variable and weather-dependent output of wind and solar power plants present a substantial challenge for planning and operating electricity-systems, particularly in the absence of cost-effective and dispatchable energy storage technologies. This study investigates a high-temperature, electrically heated, refractory-based thermal energy storage (RTES) system that stores electrical energy as sensible heat in dense ceramic bricks over the 950–1800 °C range. The stored heat can be discharged as a controlled hot-gas stream for industrial heating, fuel substitution in high-temperature processes, or electricity generation. The main novelty is a comprehensive modelling, control, mapping, and optimization framework that integrates one-dimensional transient gas–solid heat transfer, fan-assisted discharge, bypass-flow regulation, reheating logic, fan-power evaluation, insulation-loss assessment, and genetic-algorithm-based design optimization. The model uses feedback from outlet temperature and delivered power to regulate discharge, while a two-stage genetic algorithm optimizes brick-channel geometry, gas-flow operation, and multilayer insulation thicknesses. Storage capacities below 50 MWh and discharge powers of 5–30 MW are analyzed to evaluate hold time, thermal delivery, fan-power penalty, heat loss, state-of-charge evolution, and indicative capital cost. Results demonstrate that optimized and well-insulated refractory-based thermal energy storage units can provide stable, efficient, and repeatable heat delivery over multiple discharge cycles. The generated performance and cost maps support modular refractory thermal energy storage as a practical option for large-scale integration of wind and solar generation and for high-temperature industrial process heat.

25 ENERGY STORAGE

A Permanently Porous Chalcogen-Bonded Organic Framework

The nature of connectivity between constituent atomic or molecular building blocks is fundamental in shaping the properties and functionality of materials. The extrapolation of emergent interatomic interactions to enable functional materials has driven transformative technological advancements. However, the bonding interactions used in material design have been largely static since the emergence of dynamic covalent chemistry ~30 years ago. Here we demonstrate that non-covalent chalcogen bonding (Ch-bonding) is a distinct mode of interatomic connectivity for constructing functional materials by design. This is established by leveraging self-complementary assembly of 1,2,5-telluradiazole moieties to construct a honeycomb-type permanently porous Ch-bonded organic framework, assembled and stabilized solely through non-covalent Te...N contacts. Empirical and computational studies of electronic structure, structural healing and lattice dynamics highlight the pi-type electronic communication, controlled assembly and modulated lattice dynamics in Trip3Tez-I arising directly from the unique nature of the Te...N Ch-bonding that holds substantial implications for next generation crystalline semiconductors. In addition to introducing a distinct class of permanently porous frameworks, this work establishes Ch-bonding as a programmable molecular tool for constructing functional materials with distinct properties.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Giant Exfoliation Induced Magnetic Coercivity in Fe 3 GaTe 2

Permanent magnets with strong anisotropy and high coercivity underpin modern information and energy technologies, yet rare-earth-free alternatives remain limited. Here, we show that thickness engineering via mechanical exfoliation induces hard magnetic behavior in the van der Waals ferromagnet Fe 3 GaTe 2 . Bulk crystals exhibit Curie temperatures above 350 K but negligible room-temperature coercivity. When thinned below ∼100 nm, the coercive field is dramatically enhanced, reaching nearly 1 T at room temperature for in-plane fields—comparable to conventional hard magnets. Micromagnetic analysis reveals a crossover in magnetization reversal from domain-mediated processes in bulk samples to quasi-coherent rotation in thin flakes, driven by increased effective anisotropy and suppressed domain formation. This thickness-dependent transition enables tuning of magnetic hardness without chemical modification. Combined with high saturation magnetization and robust room-temperature performance, Fe 3 GaTe 2 emerges as a promising rare-earth-free material for spintronic applications. Its layered structure further allows integration into van der Waals heterostructures, where large in-plane coercivity can stabilize magnetic states against perturbations and interlayer coupling, offering potential for high-density nonvolatile memory and domain-wall-based devices.

36 MATERIALS SCIENCE

Hybrid biophysical systems for atmospheric CO 2 capture

Negative emissions technologies will be essential for limiting anthropogenic global temperature increases to 2 °C in the later years of the 21st century. Carbonic anhydrase (CA) metalloenzymes catalyze the otherwise slow conversion of CO 2 into carbonic acid (H 2 CO 3 ), suggesting their utility in the rapid hydration and downstream capture of dissolved CO 2 in aqueous media for a variety of CO 2 capture methods, such as thermal and pH swings and mineralization. The possibility of driving the rapid capture of CO 2 by catalyzing the CO 2 hydration bottleneck carries real potential for realizing efficient direct air capture (DAC) and direct ocean capture (DOC) systems. However, scaled application of CAs will be dependent on some way of economically sourcing the enzymes at volumes relevant to scaled DAC/DOC operations. In this perspective, we consider the prospect of catalyzing CO 2 hydration using a CA that is bound to the outer membrane of a cyanobacterial host, engineered constructs we call CyCAMs. Coupling extracellular CA expression to a marine, photosynthetic cyanobacterial host results in a CO 2 hydration catalyst that is continuously refreshed during the bacterial growth cycle, without the need for enzyme purification or harvesting steps. In the case of marine cyanobacteria, sunlight and the solutes native to seawater provide the respective energy, nutrients and sources of inorganic carbon essential to maintaining the bacterial population. We consider the potential impact of CA-mediated CO 2 hydration on a variety of DAC processes, with CO 2 mineralization explored as a primary use case.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Tunable high Néel temperature and large anomalous Hall response in antiferromagnetic Weyl semimetal Mn 3 Sn 1− x Ga x thin films

Antiferromagnetic Weyl semimetals based on Mn 3 X(X = Ge, Sn, Ga) kagome compounds exhibit the same ferromagnetic-like responses, including anomalous Hall, Nernst, and magneto-optical effects, as recently discussed for altermagnets. Driven by the Berry curvature due to Weyl fermions, these materials show a disproportionately large magnitude of electromagnetic effects even in the absence of large magnetization. For applications it is crucial to realize these responses in a wide range of temperatures both below and above 300 K. While stoichiometric Mn 3 X materials do not offer optimal performance, we show that Mn 3 Sn 1−x Ga x sputtered films with a variable composition offers a tunable Néel temperature, T N ≈ 425 ± 6–500 ± 15 K, which is crucial for device applications, together with a large tunable anomalous Hall effect. Our thin film growth method enables continuous and precise control over the film composition between x = 0 and x = 1. Through a detailed magnetization and Hall transport, we establish the magnetic phase diagram for the hexagonal Mn 3 Sn 1−x Ga x . Our results reveal an enhanced T N and antichiral magnetic phase in Ga-doped Mn 3 Sn and an enhanced anomalous Hall magnitude in Sn-doped Mn 3 Ga compared to their stoichiometric undoped forms. Our work demonstrates a route to optimize the technologically relevant antiferromagnets for various applications.

Magnetic properties and materials