Temperature automation for a propellant mixer

The analysis and installation of an automatic temperature controller on a propellant mixer is presented. Ultimately, the entire mixing process will come under automation, but since precise adherence to the temperature profile is very difficult to sustain manually, this was the first component to be automated. Automation is not only important for producing a uniform product, but it is necessary for envisioned space-based propellant production.

Vincent, T. L.↗

Junction-to-Case Thermal Resistance of a Silicon Carbide Bipolar Junction Transistor Measured

Junction temperature of a prototype SiC-based bipolar junction transistor (BJT) was estimated by using the base-emitter voltage (V(sub BE)) characteristic for thermometry. The V(sub BE) was measured as a function of the base current (I(sub B)) at selected temperatures (T), all at a fixed collector current (I(sub C)) and under very low duty cycle pulse conditions. Under such conditions, the average temperature of the chip was taken to be the same as that of the temperature-controlled case. At increased duty cycle such as to substantially heat the chip, but same I(sub C) pulse height, the chip temperature was identified by matching the V(sub BE) to the thermometry curves. From the measured average power, the chip-to-case thermal resistance could be estimated, giving a reasonable value. A tentative explanation for an observed bunching with increasing temperature of the calibration curves may relate to an increasing dopant atom ionization. A first-cut analysis, however, does not support this.

Niedra, Janis M.↗

The Design of a Transparent Vertical Multizone Furnace: Application to Thermal Field Tuning and Crystal Growth

We present an innovative design of a vertical transparent multizone furnace which can operate in the temperature range of 25 C to 750 C and deliver thermal gradients of 2 C/cm to 45 C/cm for the commercial applications to crystal growth. The operation of the eight zone furnace is based on a self-tuning temperature control system with a DC power supply for optimal thermal stability. We show that the desired thermal profile over the entire length of the furnace consists of a functional combination of the fundamental thermal profiles for each individual zone obtained by setting the set-point temperature for that zone. The self-tuning system accounts for the zone to zone thermal interactions. The control system operates such that the thermal profile is maintained under thermal load, thus boundary conditions on crystal growth ampoules can be predetermined prior to crystal growth. Temperature profiles for the growth of crystals via directional solidification, vapor transport techniques, and multiple gradient applications are shown to be easily implemented. The unique feature of its transparency and ease of programming thermal profiles make the furnace useful in scientific and commercial applications for determining the optimized process parameters for crystal growth.

Duvual, Walter M. B.↗

Nucleation and growth control in protein crystallization

The five topics summarized in this final report are as follows: (1) a technique for the expedient, semi-automated determination of protein solubilities as a function of temperature and application of this technique to proteins other than lysozyme; (2) a small solution cell with adjustable temperature gradients for the growth of proteins at a predetermined location through temperature programming; (3) a microscopy system with image storage and processing capability for high resolution optical studies of temperature controlled protein growth and etching kinetics; (4) growth experiments with lysozyme in thermosyphon flow ; and (5) a mathematical model for the evolution of evaporation/diffusion induced concentration gradients in the hanging drop protein crystallization technique.

Rosenberger, Franz↗

Multi-Angle Imager for Aerosols Thermal Control System

The Multi-Angle Imager for Aerosols (MAIA) Thermal Control System is a NASA funded instrument that will collect data to help characterize airborne particulate matter over a number of population centers across the globe using multi-angle spectropolarimetric imagery. The data collected by MAIA will facilitate assessments of the impacts of different types of particulate matter on adverse health outcomes. MAIA is a hosted payload meant to operate in a near-circular sun-synchronous polar orbit, with a mean altitude between 600 km and 850 km. The nominal on-orbit mission design lifetime is three years. Temperature control of the MAIA instrument is accomplished with a combination of passive radiators and heaters. The focal plane module (FPM) is cooled to ≤ 235K with a disc shaped radiator that faces the anti-sun side of the sun-synchronous orbit. The temperature of the MAIA cameras and associated electronics is controlled with a cylindrical shaped radiator that projects a near constant area in the nadir direction as the cameras rotate. A noteworthy feature of the MAIA thermal control system design is the novel, low cost, rotationally articulating thermal strap used to transfer heat from the FPMs to their associated FPM Radiator. The strap spans one of the axes of rotation, sweeping out an arc of approximately 60° as the instrument operates. A prototype of the articulating thermal strap was life tested to 260,000 cycles with no signs of significant degradation. An overview of the MAIA thermal control system baseline design is presented, with focus on its novel aspects, including life testing of the prototype articulating thermal strap. In addition, a discussion of the considerations involved in designing a thermal control system for a hosted instrument is provided.

Rosas, Rogelio↗

Studies of Model Immiscible Systems

The objectives are to use model transparent monotectics to obtain fundamental information applicable to two-phase systems in general, to apply this understanding to materials of interest in the Microgravity Science and Applications program, and to interpret results of flight experimental involving monotectic alloys. A number of model immiscible systems are in use to study various aspects of two-phase behavior within the miscibility gap and during solidification. Particle growth, coalescence and particle motions are under investigation using a holographic microscopy system. The system is capable of working with particle densities up to 10 to the 7th power particles/cubic centimeters through a 100 micron depth and can resolve particles of the order of 2 to 3 micron in diameter throughout the entire cell volume. Particle size, distribution changes with respect to time and temperature are observable from sequential holograms. Initial experiments using diethylene glycol/ethyl salicylate (DEG/ES) have demonstrated the usefulness of the technique. The thermal system controls temperature to at least plus or minus 0.001 K over the course of an experiment. A time-lapse film, made from holograms, of a succinonitrile/water solution shows particle size and number distribution changes with time under isothermal conditions. The observations are consistent with Ostwald ripening theory.

Frazier, D. O.↗

Improving 7-Day Forecast Skill by Assimilation of Retrieved AIRS Temperature Profiles

We conducted a new set of Data Assimilation Experiments covering the period January 1 to February 29, 2016 using the GEOS-5 DAS. Our experiments assimilate all data used operationally by GMAO (Control) with some modifications. Significant improvement in Global and Southern Hemisphere Extra-tropical 7-day forecast skill was obtained when: We assimilated AIRS Quality Controlled temperature profiles in place of observed AIRS radiances, and also did not assimilate CrISATMS radiances, nor did we assimilate radiosonde temperature profiles or aircraft temperatures. This new methodology did not improve or degrade 7-day Northern Hemispheric Extra-tropical forecast skill. We are conducting experiments aimed at further improving of Northern Hemisphere Extra-tropical forecast skill.

AIRS Temperature Profiles↗

Fire retardancy using applied materials

An example of advanced technology transfer from the Little Joe, Surveyor, Comsat, re-entry and Apollo age to everyday fire protection needs is presented. Utilizing the principle of sublimation cooling for thermostatic temperature control, the material meets a wide range of fire retardancy and heat transmission control requirements. Properties vary from flexible tape for conduits and electrical cables to rigid coatings for column protection, with a broad spectrum of sublimation temperatures available. The material can be applied in the field or in the factory, utilizing mass production techniques, yielding a product that is reliable, effective, widely available and low in cost.

Feldman, R.↗

Biochronometry; Proceedings of the Symposium, Friday Harbor, Wash., September 4-6, 1969.

Topics discussed include circadian activity rhythms in birds and man, variation of circadian rhythms in monkeys, resetting of circadian eclosion rhythm in fruitflies, the effectiveness of mathematical models of circadian rhythms, the influence of ac electric fields on circadian rhythms in man, the relation between changes in the metabolic rate and circadian periodicity of the resistance of pocket mice to ionizing radiation, the relation between circadian organization and the photoperiodic time measurement in moths, the circadian rhythm of optic nerve potentials in the isolated eye of the sea hare, phasing of circadian temperature rhythms in the pocket mouse by specific spectral regions, the phase-shifting effect of light on circadian rhymicity in the fruifly, hormonal control of circadian rhythms in the fruitfly, metabolically controlled temperature compensation in the circadian rhythm of algae, and circadian rhythms in the chloroplasts of algae. Individual items are abstracted in this issue.

Menaker, M.↗

Gravitational effects on process-induced defects in single crystal silicon

Description and discussion of a series of experiments which vary each of several important processing parameters including wafer orientation, temperature, gravity greater than 1 g, and ultimately zero gravity. These experiments are in progress and results to date are included from experiments which control temperature, duration of thermal cycle, and wafer orientation during 1 g processing. Preliminary evidence is presented which indicates that gravitational stresses play a role in defect generation during processing at 1 g.

Porter, W. A.↗

Support system for a 1750A VHSIC multiprocessor

A design approach for a support system or test station necessary to functionally operate a very high-speed integrated circuit (VHSIC) microprocessor brassboard is presented. Major subsystems which make up the support are the following: (1) power supply unit; (2) temperature controller unit; (3) input/output module; and (4) mechanical test fixture. Theoretical analyses and experimental techniques were utilized to design and implement the power and temperature requirements for the VHSIC processor. A functional description of the input/output module and test fixture is discussed. The support system provides the means to evaluate and functionally test a VHSIC microprocessor.

Ruggles, Stephen L.↗

Electrical Characterization of the RCA CDP1822SD Random Access Memory, Volume 1, Appendix a

Electrical characteristization tests were performed on 35 RCA CDP1822SD, 256-by-4-bit, CMOS, random access memories. The tests included three functional tests, AC and DC parametric tests, a series of schmoo plots, rise/fall time screening, and a data retention test. All tests were performed on an automated IC test system with temperatures controlled by a thermal airstream unit. All the functional tests, the data retention test, and the AC and DC parametric tests were performed at ambient temperatures of 25 C, -20 C, -55 C, 85 C, and 125 C. The schmoo plots were performed at ambient temperatures of 25 C, -55 C, and 125 C. The data retention test was performed at 25 C. Five devices failed one or more functional tests and four of these devices failed to meet the expected limits of a number of AC parametric tests. Some of the schmoo plots indicated a small degree of interaction between parameters.

Klute, A.↗

Thermal Balance of a Manned Space Station

In order for any analysis to yield reasonable results when applied to a realistic configuration, it must account for convective, conductive, and radiative heat transfer through and within the vehicle, and, unless the vehicle surface is wholly convex, for the complex interchange of radiation between external surfaces. The following is a comprehensive view of the entire heat balance problem, including internal and external radiation, conduction, and internal convection heat transfer. In addition, a specific method of temperature control, particularly suited to manned space stations is suggested. The method makes use of the "atmosphere" within the space station as a major factor in the process of heat distribution. The vehicle air is circulated between the living quarters and an area containing the bulk of the heat generating equipment. By regulating the flow rate, temperature changes in the living quarters are minimized at the expense of increased fluctuation of the equipment are temperature. This technique has been applied to a manned orbital space station (MOSS) configuration, suggested by NASA's Langley Research Center. The feasibility of this approach has been demonstrated in terms of required and available flow rates, and the range of allowable equipment temperatures.

Environmental control↗

A System for Managing Replenishment of a Nutrient Solution Using an Electrical Conductivity Controller

Control of nutrient solution parameters is very important for the growth and development of plants grown hydroponically. Protocols involving different nutrient solution replenishment times (e.g. one-week, two-week, or two-day replenishment) provide manual periodic control of the nutrient solution's electrical conductivity (EC). Since plants take-up nutrients as they grow, manual control has a drawback in that EC is not held constant between replenishments. In an effort to correct this problem the Center for Food and Environmental Systems for Human Exploration of Space at Tuskegee University has developed a system for managing and controlling levels of EC over a plant's entire growing cycle. A prototype system is being tested on sweetpotato production using the nutrient film technique (NFT), and it is being compared to a system in which sweetpotatoes are grown using NFT with manual control. NASA has played an important role in the development of environmental control systems. They have become a forerunner in growing plants hydroponically with some control systems through the use of networked data acquisition and control using environmental growth chambers. Data acquisition systems which involve the use of real-time, calibration, set points, user panel, and graphical representation programming provide a good method of controlling nutrient solution parameters such as EC and pH [Bledsoe, 19931]. In NASA's Biomass Production Chamber (BPC) at Kennedy Space Center, control is provided by a programmable logic controller (PLC). This is an industrial controller which combines ladder computer logic which has the ability to handle various levels of electrical power. The controller controls temperature, light and other parameters that affect the plant's environment, in the BPC, the Nutrient Delivery System (NIX), a sub-system of the PLC, controls nutrient solution parameters such as EC, pH, and solution levels. When the nutrient EC measurement goes outside a preset range (120-130 mS/m) a set amount of a stock solution of nutrients is automatically added by a metering pump to bring the EC back into operating range [Fortson, 1992]. This paper describes a system developed at Tuskegee University for controlling the EC of a nutrient solution used for growing sweetpotatoes with an EC controller and a computer with LabView data acquisition and instrumentation software. It also describes the preliminary data obtained from the growth of sweetpotatoes using this prototype control system.

Davis, D.↗

Accurate L-Band Measurements of the Dielectric Constant of Seawater

A new temperature controlled microwave cavity system to measure the complex dielectric constant of seawater at 1.413 GHz is discussed. The system is being developed to measure seawater for temperatures from O C to 30 C and salinities from 10 to 40 psu, The paper discusses the construction of the measurement system and initial stability tests.

Lang, R.H.↗

Recommended Maximum Temperature For Mars Returned Samples

The Returned Sample Science Board (RSSB) was established in 2015 by NASA to provide expertise from the planetary sample community to the Mars 2020 Project. The RSSB's first task was to address the effect of heating during acquisition and storage of samples on scientific investigations that could be expected to be conducted if the samples are returned to Earth. Sample heating may cause changes that could ad-versely affect scientific investigations. Previous studies of temperature requirements for returned mar-tian samples fall within a wide range (-73 to 50 degrees Centigrade) and, for mission concepts that have a life detection component, the recommended threshold was less than or equal to -20 degrees Centigrade. The RSSB was asked by the Mars 2020 project to determine whether or not a temperature requirement was needed within the range of 30 to 70 degrees Centigrade. There are eight expected temperature regimes to which the samples could be exposed, from the moment that they are drilled until they are placed into a temperature-controlled environment on Earth. Two of those - heating during sample acquisition (drilling) and heating while cached on the Martian surface - potentially subject samples to the highest temperatures. The RSSB focused on the upper temperature limit that Mars samples should be allowed to reach. We considered 11 scientific investigations where thermal excursions may have an adverse effect on the science outcome. Those are: (T-1) organic geochemistry, (T-2) stable isotope geochemistry, (T-3) prevention of mineral hydration/dehydration and phase transformation, (T-4) retention of water, (T-5) characterization of amorphous materials, (T-6) putative Martian organisms, (T-7) oxidation/reduction reactions, (T-8) (sup 4) He thermochronometry, (T-9) radiometric dating using fission, cosmic-ray or solar-flare tracks, (T-10) analyses of trapped gasses, and (T-11) magnetic studies.

Beaty, D. W.↗

User's manual for the TRW gaspipe 2 program: A vapor-gas front analysis program for heat pipes containing non-condensible gas

A digital computer program for design and analysis of heat pipes which contain non-condensible gases, either for temperature control or to aid in start-up from the frozen state, is presented. Some of the calculations which are possible with the program are: (1) wall temperature profile along a gas-loaded heat pipe, (2) amount of gas loading necessary to obtain desired evaporator temperature at a desired heat load, (3) heat load versus evaporator temperature for a fixed amount of gas in the pipe, and (4) heat and mass transfer along the pipe, including the vapor-gas front region.

Edwards, D. K.↗

Cryogenic Absorption Cells Operating Inside a Bruker IFS-125HR: First Results for 13CH4 at 7 Micrometers

New absorption cells designed specifically to achieve stable temperatures down to 66 K inside the sample compartment of an evacuated Bruker IFS-125HR Fourier transform spectrometer (FTS) were developed at Connecticut College and tested at the Jet Propulsion Laboratory (JPL). The temperature stabilized cryogenic cells with path lengths of 24.29 and 20.38 cm were constructed of oxygen free high conductivity (OFHC) copper and fitted with wedged ZnSe windows using vacuum tight indium seals. In operation, the temperature-controlled cooling by a closed-cycle helium refrigerator achieved stability of 0.01 K. The unwanted absorption features arising from cryodeposits on the cell windows at low temperatures were eliminated by building an internal vacuum shroud box around the cell which significantly minimized the growth of cryodeposits. The effects of vibrations from the closed-cycle helium refrigerator on the FTS spectra were characterized. Using this set up, several high-resolution spectra of methane isotopologues broadened with nitrogen were recorded in the 1200-1800 per centimeter spectral region at various sample temperatures between 79.5 and 296 K. Such data are needed to characterize the temperature dependence of spectral line shapes at low temperatures for remote sensing of outer planets and their moons. Initial analysis of a limited number of spectra in the region of the R(2) manifold of the v4 fundamental band of 13CH4 indicated that an empirical power law used for the temperature dependence of the N2-broadened line widths would fail to fit the observed data in the entire temperature range from 80 to 296 K; instead, it follows a temperature-dependence similar to that reported by Mondelain et al. [17,18]. The initial test was very successful proving that a high precision Fourier transform spectrometer with a completely evacuated optical path can be configured for spectroscopic studies at low temperatures relevant to the planetary atmospheres.