Search NASA⌕ Search

SEARCH · Search NASA

Results for “Testing Procedure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Knowledge-Based Hazardous Waste Determinations for Solar Photovoltaic (PV) Modules: A Foundational Study

This report explores using "generator knowledge" to determine whether a solar photovoltaic (PV) module must be managed as hazardous waste prior to recycling or landfilling. Generator knowledge is a legal term and existing regulatory pathway for making a hazardous waste determination that has been used by other industries but is a relatively unknown option to the PV industry. In the United States, a hazardous waste determination often acts as a pre-requisite to recycle or landfill a PV module. The results of the hazardous waste determination dictate whether the PV module must be managed as hazardous waste or nonhazardous solid waste. Managing a PV module as hazardous waste requires compliance with stringent U.S. federal and state hazardous waste law. In addition to increased management costs, which can be ten times higher, legal liability for PV modules regulated as hazardous waste is also heightened with both civil and criminal penalties for noncompliance which includes making an inaccurate or faulty hazardous waste determination. The most common reason a PV module would be regulated as hazardous is if it contains a regulated metal in an amount that equals or exceeds the toxicity characteristic limits. To determine whether a PV module exhibits a hazardous characteristic, the regulated person/entity must "apply knowledge...in light of the materials and processes used." In the absence of adequate knowledge to determine whether the PV module is hazardous, it must be tested using Test Method 1311 Toxicity Characteristic Leaching Procedure (TCLP) or an equivalent EPA-approved method. Although TCLP is the predominant method used to today to make a hazardous waste determination for PV modules, evidence from this study concludes it is not practical to TCLP test every PV module even in a single utility-scale installation, and a scalable solution is needed. This study finds that knowledge-based hazardous waste determinations may allow a regulated person/entity to make a hazardous waste determination for more than one PV module at one time - making this regulatory pathway a potential scalable solution. Through legal analysis and interviews with 44 experts, the authors explore what it means to make an accurate knowledge-based hazardous determination for PV modules considering sources and forms of information as well as potential limitations. The work aims to provide a foundation for building consensus on whether knowledge-based hazardous determinations are a viable, scalable industry approach for solar.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Draft Plan to Develop Non-Intrusive Load Monitoring Test Protocols

This document presents a Draft Plan proposed to develop a common test protocol that can be used to evaluate the performance requirements of Non-Intrusive Load Monitoring. Development on the test protocol will be focused on providing a consistent method that can be used to quantify and compare the performance characteristics of NILM products. Elements of the protocols include specifications for appliances to be used, metrics, instrumentation, and a procedure to simulate appliance behavior during tests. In addition, three priority use cases for NILM will be identified and their performance requirements will specified.

47 OTHER INSTRUMENTATION↗

Insulation Coordination Design for Grid-Connected Solid-State Transformers

The deployment of solid-state transformers (SSTs) in medium-voltage (MV) distribution systems is facing various challenges, especially the challenge of insulation coordination design against grid-originated lightning impulses. In this article, two challenges in existing insulation coordination designs for grid-connected SSTs are identified. One challenge is the mismatch between metal-oxide varistor (MOV) protective levels and SST insulation strength, the other challenge is the incompatibility of standard impulse test on SST protective structures. To address the MOV selection challenge, a novel lightning protection scheme is designed to protect a single-stage SST where the semiconductor modules are directly exposed to external lightning impulses. Here, the in-lab lightning impulse tests are performed to verify the overvoltage attenuation performance of the prototyped lightning protection scheme. To address the impulse test challenge, the surge withstand capability of the protected SST is comprehensively evaluated with a complete set of insulation coordination design procedures beyond the basic insulation level (BIL) test. After these two challenges are addressed, a discussion is presented on substituting conventional transformers with the protected SSTs into insulation-coordinated distribution systems to facilitate the field deployment of SSTs.

solid-state transformer (SST)↗

SU-F-T-226: QA Management for a Large Institution with Multiple Campuses for FMEA

Purpose: To redesign our radiation therapy QA program with the goal to improve quality, efficiency, and consistency among a growing number of campuses at a large institution. Methods: A QA committee was established with at least one physicist representing each of our six campuses (22 linacs). Weekly meetings were scheduled to advise on and update current procedures, to review end-to-end and other test results, and to prepare composite reports for internal and external audits. QA procedures for treatment and imaging equipment were derived from TG Reports 142 and 66, practice guidelines, and feedback from ACR evaluations. The committee focused on reaching a consensus on a single QA program among all campuses using the same type of equipment and reference data. Since the recommendations for tolerances referenced to baseline data were subject to interpretation in some instances, the committee reviewed the characteristics of all machines and quantified any variations before choosing between treatment planning system (i.e. treatment planning system commissioning data that is representative for all machines) or machine-specific values (i.e. commissioning data of the individual machines) as baseline data. Results: The configured QA program will be followed strictly by all campuses. Inventory of available equipment has been compiled, and additional equipment acquisitions for the QA program are made as needed. Dosimetric characteristics are evaluated for all machines using the same methods to ensure consistency of beam data where possible. In most cases, baseline data refer to treatment planning system commissioning data but machine-specific values are used as reference where it is deemed appropriate. Conclusion: With a uniform QA scheme, variations in QA procedures are kept to a minimum. With a centralized database, data collection and analysis are simplified. This program will facilitate uniformity in patient treatments and analysis of large amounts of QA data campus-wide, which will ultimately facilitate FMEA.

43 PARTICLE ACCELERATORS↗

Tank 50 Simulant Grout and Toxicity Characteristic Leaching Procedure (TCLP) Results for Methyl Mercury Waste Acceptance Criteria (WAC) Limit

Testing of simulated Tank 50 salt solution grout, spiked with methyl mercury (MeHg) and ionic mercury, used the Toxicity Characteristic Leaching Procedure (TCLP) to evaluate leaching performance with respect to Hg and the Waste Acceptance Criteria (WAC) limits for the Saltstone Production Facility (SPF). This report describes the test parameters for simulant preparation and confirmatory analysis, grout preparation, TCLP leach testing and subsequent leachate analyses. These scoping tests were designed to provide an initial evaluation of the effect of increased MeHg and ionic Hg on the TCLP and were requested by Savannah River Remediation LLC (SRR) through a Technical Assistance Request (TAR). It is expected that this preliminary testing will likely lead to future, more detailed, testing involving the mercury (Hg) WAC and Hg limits with respect to the Tank 50 TCLP for mercury. The TCLP concentrations for total Hg have approached 0.06 mg/L in recent years for Tank 50 radioactive solutions containing up to 105 mg/L of Hg in the form of ionic (Hg(I/II), elemental (Hg(0)) and organo-mercury such as MeHg. In discussions with SRR personnel, it was decided for this non-baseline work to target Hg spike concentrations, using predominately MeHg, in the range of 150 to 350 mg/L total Hg to investigate corresponding Hg TCLP leaching behaviors.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Application of pH-dependent environmental protection agency test method 1313 to low-activity nuclear waste glass

Here, in this study, we present results of a room temperature, pH-dependent leach test established by United States Environmental Protection Agency (EPA) Leaching Environmental Assessment Framework (LEAF) (EPA Method 1313 and further abbreviated EPA 1313) to study the alteration behavior of low-activity nuclear waste (LAW) glasses. Implementation of EPA 1313, which is closer to LAW disposal temperatures, could allow for more flexibility in the formulation of Hanford LAW glasses, specifically in terms of increased waste loading. A set of 48 LAW glasses were selected to test with EPA 1313. Briefly, the test method consists of adding glass to a number of solutions at different initial pH values and at a fixed mass-to-solution-volume ratio. The glass is then allowed to corrode for two days and the final solution pH and concentration of different glass elements in solution is measured. The test was modified from the published procedure to constrain particle size to provide more reproducible results, reduce the studied pH range to a more applicable range, and to reduce solution volume to reduce costs associated with material preparation. Compositional modeling was used to predict the measured elemental releases at various pH. The model predictions improved in tests where there was a relatively small difference between initial and final solution pH indicating that pH controls would result in better predictive models.

Accelerated aging↗

Test Plan for the Horizontal Dry Cask Simulator

The thermal performance of commercial spent nuclear fuel dry storage casks is evaluated through detailed numerical analysis. These modeling efforts are completed by the vendor to demonstrate performance and regulatory compliance. The calculations are then independently verified by the Nuclear Regulatory Commission(NRC). Canistered dry storage cask systems rely on ventilation between the inner canister and the overpack to convect heat away from the canister to the surrounding environment for both horizontal and vertical configurations. Recent advances in dry storage cask designs have significantly increased the maximum thermal load allowed in a cask in part by increasing the efficiency of internal conduction pathways and by increasing the internal convection through greater canister helium pressure. Carefully measured data sets generated from testing of full sized casks or smaller cask analogs are widely recognized as vital for validating these models. While several testing programs have been previously conducted, these earlier validation studies did not integrate all the physics or components important in a modern, horizontal dry cask system. The purpose of the investigation described in this test plan is to produce data sets that can be used to benchmark the codes and best practices presently used to determine cladding temperatures and induced cooling air flows in modern horizontal dry storage systems. The horizontal dry cask simulator(HDCS) has been designed to generate this benchmark data and add to the existing knowledgebase. The pressure vessel representing the canister has been designed, fabricated, and pressure tested for a maximum allowable pressure(MAWP)rating of 2,400 kPa at400 °C. An existing electrically heated but otherwise prototypic boiling water reactor(BWR), Incoloy-clad test assembly will be deployed inside of a representative storage basket and canister. An insulated sheet metal enclosure will be used to mimic the thermal properties of the concrete vault enclosure used in a modern horizontal storage system. Radial and axial temperature profiles along with induced cooling air flow will be measured for a wide range of decay powers and representative(and higher)cask pressures using various backfills of helium, argon, or air. The single assembly geometry with well-controlled boundary conditions simplifies computational requirements while preserving relevant physics. The proposed test apparatus integrates all the underlying thermal-hydraulics important to defining the performance of a modern horizontal storage system. These include combined-mode heat transfer from the electrically-heated assembly to the canister walls and the primarily natural-convective heat transfer from the canister to the cooling air flow passing through the horizontal vault enclosure. The objective of the HDCS is not to reproduce the performance of a commercial dry storage system for any given set of operational parameters. Rather ,the objective is to capture the dominant physics in a well-characterized test apparatus. The close coupling between the thermal response of the canister system and the resulting induced cooling air flow rate is of particular importance. While incorporating the best available information based on thermal-hydraulic scaling arguments as well as previous vertical testing, this test plan is subject to changes due to improved understanding or from as built deviations to designs. As-built conditions and actual procedures will be documented in the final test report.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optimal Geometry for Focused Ion Beam-Milled Samples for Direct-Pull Micro-Tensile Testing Performed In Situ in a Scanning Electron Microscope

A thorough procedure was developed to efficiently manufacture dogbone samples using focused ion beam (FIB) milling for micro-tensile testing. A Bruker PI 89 PicoIndenter, Billerica, MA, USA, was used as a case study, although the analysis and results are applicable to other micro-mechanical testing systems capable of mounting a standard, Ø12.7 mm × Ø3.2 mm pin, scanning electron microscopy (SEM) pin stub (Ted Pella, Redding, CA, USA). Nine dogbones were made from an Fe-45Cu alloy additively manufactured using powder-fed laser-directed energy deposition (DED-LB). Testing showed that fracture was confined to the gauge section for all dogbones and that the fracture mode, ductile vs. brittle, was entirely dependent on the grain orientation relative to the loading direction. The analysis showed that the measured plastic strain to failure can vary from >11% (optimal geometry) to <1% (non-optimal geometry) in micro-tensile testing of high-tensile-strength (>1 GPa) metallic materials. Subsequently, a finite element analysis (FEA) was conducted to identify the improved dogbone geometries. A total of ten thousand dogbone geometries were tested, and their dimensions were defined by a set of four adjustable parameters (corner radius, load surface angle, load surface length, and dogbone head length). The gauge width and gauge length were fixed to 4 µm and 10 µm, respectively. Three-dimensional surface plots of the stress concentration as a function of two parameters were used to identify the optimal ranges of parameter values. The addition of maximum width and length constraints, measuring 25 µm and 30 µm, respectively, allowed us to identify an optimal geometry at load surface angles of 30° and 45°. Their respective dimensions (corner radius, load surface length, and dogbone head length) are, in µm, 12, 6, and 7 and 10, 7, and 7. Testing these two optimal geometries with a range of gauge lengths from 4 to 20 µm showed that smaller gauge lengths only slightly reduced the detrimental stress concentration outside the gauge section. However, smaller gauge lengths will notably improve the FIB surface polishing step as tapering is reduced with smaller dogbone lengths.

Chemistry↗

Energy and power quality measurement for electrical distribution in AC and DC microgrid buildings

Today's selection of DC microgrid buildings features a diverse set of electrical topologies and turnkey solutions, each with specific design trade-offs and optimizations. Designers desperately need standardized metrics and procedures for measurement and verification (M&V) to analyze and compare the advantages of each DC solution to traditional AC building networks. This work develops M&V procedures for quantifying and comparing the energy efficiency and power quality in buildings. To calculate full-building efficiency, this work introduces the measurement-informed modeling method, a procedure that develops and refines a building's energy model with metered data. To quantify power quality, this work defines a new voltage quality index that applies to both AC and DC buildings. This article describes the equipment, instrumentation, and operation necessary to calculate the efficiency and power quality. It then demonstrates these methods with a set of field tests. We report these M&V procedures can ultimately be used to compare and improve the efficiency and power quality of various DC topologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Precision of Product Consistency Tests with Reference Glasses ARM-1 and SRM 623

An interlaboratory study (ILS) was conducted in 2014 to measure the precision with which the ASTM-International product consistency test method A (PCT-A) can be performed using properly prepared samples of reference glass ARM-1 or SRM 623 and test parameter values near the centers of ranges specified in procedure ASTM C1285. The ILS did not evaluate the full range of test parameter values allowed in the PCT-A method and the results do not represent the precision that should be expected if extreme values of the ranges are used. However, the precision measured in the ILS quantified the precision of tests conducted with mean parameters that were used to estimate the effects of individual parameters. Follow-on tests were conducted to assess the effects of several individual test parameter values on the test response and uncertainties in the derived glass dissolution rates. The effects of particle size distributions in glass samples prepared by wet- and dry-sieving methods, methods to remove fines, and the limiting parameter values for the water-to-glass (w/g) mass ratio and test duration allowed in PCT-A were measured. Test responses for all variations except test duration exceeded the precision measured in the ILS for conducting triplicate PCT-A tests within a single laboratory. The accuracy of glass dissolution rates derived from PCT results benefits from using a tighter control of these test variables than required in ASTM C1285. Comparison with previous analyses of the method shows how use of the relative standard deviation to represent the test precision can be misleading, and that the mean response and standard deviation should both be considered.

36 MATERIALS SCIENCE↗

Design and execution of a verification, validation, and uncertainty quantification plan for a numerical model of left ventricular flow after LVAD implantation

Left ventricular assist devices (LVADs) are implantable pumps that act as a life support therapy for patients with severe heart failure. Despite improving the survival rate, LVAD therapy can carry major complications. Particularly, the flow distortion introduced by the LVAD in the left ventricle (LV) may induce thrombus formation. While previous works have used numerical models to study the impact of multiple variables in the intra-LV stagnation regions, a comprehensive validation analysis has never been executed. The main goal of this work is to present a model of the LV-LVAD system and to design and follow a verification, validation and uncertainty quantification (VVUQ) plan based on the ASME V&V40 and V&V20 standards to ensure credible predictions. The experiment used to validate the simulation is the SDSU cardiac simulator, a bench mock-up of the cardiovascular system that allows mimicking multiple operation conditions for the heart-LVAD system. The numerical model is based on Alya, the BSC’s in-house platform for numerical modelling. Alya solves the Navier-Stokes equation with an Arbitrary Lagrangian-Eulerian (ALE) formulation in a deformable ventricle and includes pressure-driven valves, a 0D Windkessel model for the arterial output and a LVAD boundary condition modeled through a dynamic pressure-flow performance curve. The designed VVUQ plan involves: (a) a risk analysis and the associated credibility goals; (b) a verification stage to ensure correctness in the numerical solution procedure; (c) a sensitivity analysis to quantify the impact of the inputs on the four quantities of interest (QoIs) (average aortic root flow $Q^{avg}_{Ao}$, maximum aortic root flow $Q^{max}_{Ao}$, average LVAD flow $Q^{avg}_{VAD}$, and maximum LVAD flow $Q^{max}_{VAD}$; (d) an uncertainty quantification using six validation experiments that include extreme operating conditions. Numerical code verification tests ensured correctness of the solution procedure and numerical calculation verification showed a grid convergence index (GCI)95% <3.3%. The total Sobol indices obtained during the sensitivity analysis demonstrated that the ejection fraction, the heart rate, and the pump performance curve coefficients are the most impactful inputs for the analysed QoIs. The Minkowski norm is used as validation metric for the uncertainty quantification. It shows that the midpoint cases have more accurate results when compared to the extreme cases. The total computational cost of the simulations was above 100 [core-years] executed in around three weeks time span in Marenostrum IV supercomputer. This work details a novel numerical model for the LV-LVAD system, that is supported by the design and execution of a VVUQ plan created following recognised international standards. We present a methodology demonstrating that stringent VVUQ according to ASME standards is feasible but computationally expensive.

59 BASIC BIOLOGICAL SCIENCES↗

The Precision of Product Consistency Tests with Environmental Assessment Glass

Several series of triplicate tests conducting following the ASTM C1285 product consistency test method have been performed using samples of Environmental Assessment glass in Teflon™ and steel test vessels. The results of tests with test parameters within the ranges specified in the PCT method A procedure were used to calculate repeatability and reproducibility precision statistics for tests in each type of vessel. These show the test response and test precision attained in tests conducted in Teflon™ and stainless steel test vessels are statistically indistinguishable.

36 MATERIALS SCIENCE↗

Mitigating Corrosion in Mg Sheet in Conjunction with a Sheet-Joining Method that Satisfies Structural Requirements within Sub-assemblies

This work was undertaken as a LightMAT project funded by the DOE-Vehicles Technology Office. The goal of this work was to develop corrosion protection strategies that simultaneously mitigate corrosion and achieve Class-A surface finish for Mg components in automotive applications. While automotive metals such as steel and aluminum are protected against corrosion through a variety of coating schemes/packages, the efficacy of these existing coating schemes for Mg and Mg- joints is not clear and needs to be determined. Therefore, five commercially available coating schemes and two joining techniques (riveting and Arplas resistance spot welding) were evaluated. The corresponding individual Mg sheet coupons or Mg/Mg joint test coupons were provided by Magna that were then corrosion tested at PNNL using ASTM B117 procedure. The microstructures and mechanical properties of the coupons were analyzed to determine the effectiveness of the joining and corrosion mitigation strategies. Of the coating schemes evaluated, Henkel Bonderite MgC 2.0 pre-treatment + E-coat showed the best corrosion protection and surface finish for individual Mg coupons and Arplas resistance spot welded coupons. However, the strength of Mg/Mg welded joint was reduced after corrosion testing due to some corrosion at the weld nugget. Mg/Mg rivet joints in conjunction with Chemetall oxisilan pre-treatment + polyurethane coating showed good corrosion resistance and some discoloration on the surface finish. Coating schemes comprising pre-treatment with Alodine 5200 + E-coat or Bonderite 1455 + polyurethane coating, in conjunction with Al rivet joints, showed significant corrosion and extensive discoloration of the surface. We anticipate that the results from this work will provide useful guidance to the automotive industry in selecting the appropriate combinations of corrosion protection coatings and joining techniques to fabricate light-weight Mg-based automotive components.

36 MATERIALS SCIENCE↗

Experimental study of the downstream effect of LOCA-generated debris on the pressure drop of full scale fuel assembly

The emergency core cooling system (ECCS) works to cool the reactor core in the event of a postulated loss-of-coolant accident (LOCA). The long-term reactor cooling water of ECCS comes from containment sump. Usually, the containment sump contains one or more screens to prevent the components of the ECCS from debris which could be washed into the sump. Large debris is blocked by the sump screens. However, some of the debris, such as fibrous, chemical precipitates and small particles may be ingested into the ECCS and subsequently into the reactor coolant systems (RCS), which would challenge the long-term core cooling (LTCC) and threaten the reactor core safety. NRC address this concern Generic Letter 2004-02. Westinghouse has evaluated the AP1000 1/4 height fuel assembly head-loss test in response to the issue. AVERA also perform the scaled 1/3 height mock-up fuel assembly test. The debris effect on the pressure drop of half-length mock-up PLUS7 fuel assembly of APR1400 were performed in KHNP. Numerical simulation by RELAP5-3D were performed for the debris-generated core blockage and full core as well as core bypass blockage condition were considered. However, the test in the works mentioned above use the scaled down FA (1/4, 1/3 or 1/2 length of a full FA), and didn't give the relationship between pressure drop and debris batches. The purpose of this study was to extend the debris effect to the full scale PWR fuel assembly, and identified batch by batch effect of debris to head loss of FA. The specific experimental procedure is concluded. The pressure drop test without adding debris is performed at the beginning and then three kinds of debris are added to the test loop step by step to test their effect on the pressure drop of fuel assembly. Two kinds of tests have been carried out, and the quantitative pressure data are obtained and analysis is provided. This work provides reliable and quantitative data for nuclear power plant (NPP) downstream effect analysis and safety analysis program, which is important to for licensing of NPP and further benchmark exercise. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Improving an Acoustic Vehicle Detector Using an Iterative Self-Supervision Procedure

In many non-canonical data science scenarios, obtaining, detecting, attributing, and annotating enough high-quality training data is the primary barrier to developing highly effective models. Moreover, in many problems that are not sufficiently defined or constrained, manually developing a training dataset can often overlook interesting phenomena that should be included. To this end, we have developed and demonstrated an iterative self-supervised learning procedure, whereby models are successfully trained and applied to new data to extract new training examples that are added to the corpus of training data. Successive generations of classifiers are then trained on this augmented corpus. Using low-frequency acoustic data collected by a network of infrasound sensors deployed around the High Flux Isotope Reactor and Radiochemical Engineering Development Center at Oak Ridge National Laboratory, we test the viability of our proposed approach to develop a powerful classifier with the goal of identifying vehicles from continuously streamed data and differentiating these from other sources of noise such as tools, people, airplanes, and wind. Using a small collection of exhaustively manually labeled data, we test several implementation details of the procedure and demonstrate its success regardless of the fidelity of the initial model used to seed the iterative procedure. Finally, we demonstrate the method’s ability to update a model to accommodate changes in the data-generating distribution encountered during long-term persistent data collection.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Test Plan for the Boiling Water Reactor Dry Cask Simulator

The thermal performance of commercial nuclear spent fuel dry storage casks are evaluated through detailed numerical analysis . These modeling efforts are completed by the vendor to demonstrate performance and regulatory compliance. The calculations are then independently verified by the Nuclear Regulatory Commission (NRC). Carefully measured data sets generated from testing of full sized casks or smaller cask analogs are widely recognized as vital for validating these models. Recent advances in dry storage cask designs have significantly increased the maximum thermal load allowed in a cask in part by increasing the efficiency of internal conduction pathways and by increasing the internal convection through greater canister helium pressure. These same vertical, canistered cask systems rely on ventilation between the canister and the overpack to convect heat away from the canister to the environment for both above and below-ground configurations. While several testing programs have been previously conducted, these earlier validation attempts did not capture the effects of elevated helium pressures or accurately portray the external convection of above-ground and below-ground canistered dry cask systems. The purpose of the investigation described in this report is to produce a data set that can be used to test the validity of the assumptions associated with the calculations presently used to determine steady-state cladding temperatures in modern vertical, canistered dry cask systems. The BWR cask simulator (BCS) has been designed in detail for both the above-ground and below-ground venting configurations. The pressure vessel representing the canister has been designed, fabricated, and pressure tested for a maximum allowable pressure (MAWP) rating of 24 bar at 400 deg C. An existing electrically heated but otherwise prototypic BWR Incoloy-clad test assembly is being deployed inside of a representative storage basket and cylindrical pressure vessel that represents the canister. The symmetric single assembly geometry with well-controlled boundary conditions simplifies interpretation of results. Various configurations of outer concentric ducting will be used to mimic conditions for above and below-ground storage configurations of vertical, dry cask systems with canisters. Radial and axial temperature profiles will be measured for a wide range of decay power and helium cask pressures. Of particular interest is the evaluation of the effect of increased helium pressure on allowable heat load and the effect of simulated wind on a simplified below ground vent configuration. While incorporating the best available information, this test plan is subject to changes due to improved understanding from modeling or from as-built deviations to designs. As-built conditions and actual procedures will be documented in the final test report.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Preliminary Enhanced LAW Glass Formulation Algorithm

This report summarizes the Preliminary Enhanced LAW Glass Formulation Algorithm, its background information, and the calculations it performs. The Preliminary Enhanced LAW Glass Formulation Algorithm is a tool that has been developed in MATLAB to formulate glass at a given a waste composition, while attempting to maximize waste loading. It is intended for use at the Hanford Waste Treatment and Immobilization Plant, where nuclear waste will be vitrified into glass for safe, long-term storage. The formulated glass is required to meet several processing and product quality constraints. In addition, calculations must account for associated uncertainties in constraint prediction and measurement. The algorithm also allows for the ability to hold glass compositions closer to tested regions in order to increase confidence in the output. The algorithm must also follow nuclear quality assurance procedures and submit to rigorous validation and verification testing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Computer-Based Procedures Among Older Adults: Findings from the Rancor Microworld Simulator

As with many industries worldwide, nuclear energy is experiencing an aging workforce; older than other energy sources and the national average. For example, while almost one in three nuclear industry professionals are 55+ years, for oil and gas that number is one in five. The challenges brought about by an aging workforce are one of the industry’s top concerns. However, the industry lacks for empirical research that examines the effects of developmental aging in older workers, as well as the interactions between aging and new digital technologies. We present the results of an experiment that tested three different computer-based procedures in a sample of 30 older adults (55+ years). While the industry has traditionally relied on paper-based procedures, these are being modernized by digital technology. Participants were randomly assigned to one of three procedure-types that varied by the level of digitalization, based on the IEEE Standard-1786. Type 1 essentially represents a digital representation of a paper-based procedure, Type 2 adds embedded indicators, and Type 3 adds soft controls. Participants performed two different operational scenarios (startup and loss of feedwater) on a simplified nuclear power plant simulator. Results revealed a weak signal that Type 2 may produce lower workload and lower completion times in some instances. However, there were no significant effects of procedure-type across any other outcomes, including simulator log data, situation awareness, and preference ratings. We discuss our findings in terms of optimal levels of digitalization/automation for an aging nuclear workforce and suggest pathways for future directions.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗