Search NASA⌕ Search

SEARCH · Search NASA

Results for “Transient Testing Reactor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Results of high heat flux tests of tungsten divertor targets under plasma heat loads expected in ITER and tokamaks (review)

Heat loads on the tungsten divertor targets in the ITER and the tokamak power reactors reach ~10MW m{sup −2} in the steady state of DT discharges, increasing to ~0.6–3.5 GW m{sup −2} under disruptions and ELMs. The results of high heat flux tests (HHFTs) of tungsten under such transient plasma heat loads are reviewed in the paper. The main attention is paid to description of the surface microstructure, recrystallization, and the morphology of the cracks on the target. Effects of melting, cracking of tungsten, drop erosion of the surface, and formation of corrugated and porous layers are observed. Production of submicron-sized tungsten dust and the effects of the inhomogeneous surface of tungsten on the plasma–wall interaction are discussed. In conclusion, the necessity of further HHFTs and investigations of the durability of tungsten under high pulsed plasma loads on the ITER divertor plates, including disruptions and ELMs, is stressed.

36 MATERIALS SCIENCE↗

Development and Porting of Nuclear Reactor Computational Models for the NRIC Virtual Test Bed in FY23

The U.S. DOE’s National Reactor Innovation Center (NRIC) hosts an open-source website and associated GitHub repository called the Virtual Test Bed (VTB) on which computational models for advanced reactors are documented and shared with the reactor community. In FY23 under the NRIC program, computational models for nuclear reactor analysis were developed and contributed to the VTB Github repository during FY23 by contributors at Argonne National Laboratory. Other models developed outside of NRIC were also ported to the VTB as part of this work, serving a broader mission to make computational reactor analysis models more widely available to the reactor community. The model development activities focused on demonstration of gas-cooled microreactor models including computational fluid dynamics simulations of flow through an industry-inspired air jacket design, and simulation of multiphysics transients for a gas-cooled microreactor assembly. Additionally, development of a molten salt reactor (led at Idaho National Laboratory) was supported through Argonne’s expertise in multigroup cross sections generation. Models for these two reactor types were targeted due to their relevancy to NRIC’s Demonstration of Microreactor Experiments (DOME) and Laboratory for Operation and Testing in the U.S. (LOTUS) physical test beds, which are slated to host microreactor and molten salt reactor experiments. The model porting activities consisted of developing detailed documentation for several physics models which originate from the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program. We include only contributions from Argonne National Laboratory in this report.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Modeling a Gas-Cooled Microreactor Balance of Plant for the Virtual Test Bed

High Temperature Gas-cooled Reactors (HTGRs) are one of the technology considered for microreactor designs because of their high performance and technological maturity. Several designs are being developed. These microreactor cores are connected to power conversion system (PCS) through a heat exchanger. For transient analysis, the feedback of the PCS or of the primary loop can be important, therefore, it is necessary to develop robust models for the balance of plant that can be coupled to a core model. In this work, a balance of plant model using the MOOSE Thermal Hydraulics module (THM) is presented and demonstrated for startup and load-follow transients. This model can be seamlessly coupled with any MOOSE-based multi-physics core model using the MOOSE multi-app approach.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of a Griffin model of the advanced test reactor

In the pursuit of a higher fidelity deterministic simulation capability of the Advanced Test Reactor, it is important to have a fast yet accurate deterministic neutronics model. Here, to achieve this, we employed an advanced two-step method. The first step involves generating homogenized cross sections using OpenMC, a cutting-edge Monte Carlo neutron transport code. OpenMC offers excellent modular capabilities, allowing for easy component integration and flexibility in incorporating new designs into the model. The second step involves deterministic transport calculations, which are performed using Griffin, a reactor physics application based on the Multiphysics Object-Oriented Simulation Environment (MOOSE). To ensure the accurate spatial resolution and assignment of material cross sections, a Cubit-generated mesh for the Advanced Test Reactor is utilized as an intermediate step between the OpenMC and Griffin models; Griffin utilizes the mesh for its finite element solution, while OpenMC material identifications are written to the mesh file to be used in Griffin material assignments. Additionally, a Python-based script converts the cross sections generated by OpenMC into the ISOXML format required by Griffin. Initial comparisons using the Griffin diffusion solver indicated good agreement between the neutron multiplication factors obtained from the standalone OpenMC model and the Griffin model, with differences of less than 10 pcm in the 2D geometry configuration; it was later determined that this agreement was likely due to compensating effect and was more likely on the order of –700 pcm relative to the OpenMC solution. However, in three-dimensional calculations, an unacceptably large error (almost 8,000 pcm) was found in the Griffin solution with the diffusion solver. Subsequent calculations using Griffin’s discrete ordinates solver demonstrated substantially improved agreement, within 116 pcm of the OpenMC solution used to generate the cross sections for Griffin. Building on this capability, future work will seek to perform more detailed validation calculations. The ultimate goal is to evaluate both transient and multiphysics simulations of the reactor.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

An investigation of FeCrAl cladding behavior under normal operating and loss of coolant conditions

Iron-chromium-aluminum (FeCrAl) alloys are candidates to be used as nuclear fuel cladding for increased accident tolerance. An analysis of the response of FeCrAl under normal operating and loss of coolant conditions has been performed using fuel performance modeling. In particular, recent information on FeCrAl material properties and phenomena from separate effects tests has been implemented in the BISON fuel performance code and analyses of integral fuel rod behavior with FeCrAl cladding have been performed. BISON simulations included both light water reactor normal operation and loss-of-coolant accidental transients. In order to model fuel rod behavior during accidents, a cladding failure criterion is desirable. For FeCrAl alloys, a failure criterion is developed using recent burst experiments under loss of coolant like conditions. The added material models are utilized to perform comparative studies with Zircaloy-4 under normal operating conditions and oxidizing and non-oxidizing out-of-pile loss of coolant conditions. The results indicate that for all conditions studied, FeCrAl behaves similarly to Zircaloy-4 with the exception of improved oxidation performance. Here, further experiments are required to confirm these observations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Multiphysics Evaluation of Annular Uranium-Zirconium Metallic Fuels [Poster]

This study examines the performance of U-10Zr annular metallic fuel rodlets which were experimentally evaluated as part of the Advanced Fuels Campaign (AFC). The AFC mission is to develop novel fuel technologies and facilitate the implementation of those technologies by industry partners. A key objective is to improve steady-state and transient performance over current fuel types. The experiments of interest in this study included annular metallic U-Zr fuel rodlets within HT-9 cladding which were placed in SS-316 capsules and inserted in the Advanced Test Reactor (ATR). Certain mechanical and thermal conditions cannot be directly evaluated through experiments and fuel performance modeling is used to shed light on this evolution over time. In this study, BISON Multiphysics simulations are leveraged to investigate the state of the fuel system throughout and after the experimental conditions.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Demonstration of an Ultra-Short Channel Metal Monolith Catalytic Reactor for Trace Contaminant Control Applications

The International Space Station (ISS) Trace Contaminant Control Subassembly (TCCS) design is based upon proven, highly reliable technology. However, because its core unit operations rely upon expendable activated charcoal and an indirectly heated high temperature catalyst, annual logistics mass, crew time, and power consumption requirements are significant. To address this situation, a unique catalytic reactor design has been developed which is suitable for retrofit into the TCCS's high temperature catalytic oxidizer (HTCO) assembly. The unique design, which employs a metallic, ultra-short channel length monolith (USCM) catalyst substrate, was tested in a flight-like TCCS HTCO assembly to investigate its performance characteristics. Test results indicate that retrofitting the TCCS with a USCM-based catalytic reactor is feasible and that it may provide significant reductions in logistics mass, crew time, and power consumption. Savings indicated by test results are up to 81% for annual logistics, 56% for crew time, and 77% for startup transient duration. In addition, its demonstrated ability to operate in a power saving mode provides up to a 43% savings in average power consumption. A summary of the USCM demonstration test objectives, approach, results, and specific benefits to the TCCS's process economics are presented,

Perry, J. L↗

SAS4A/SASSYS-1 Validation with EBR-II Tests Performed During the SHRT Testing Program (Rev. 2)

The EBR-II sodium-cooled fast reactor supported a wide range of fast reactor research activities. The final fifteen years of operations at EBR-II were used for experiments and tests to demonstrate the importance of passive safety in liquid metal reactors and the capability of such systems to provide strong passive responses during off-normal conditions. The Shutdown Heat Removal Test program at EBR-II provided test data supporting the validation of computer codes for design, licensing, and operation of LMRs, among other objectives. The program included nearly sixty tests, most of which were protected and unprotected loss of flow and loss of heat sink tests run at various initial powers and flow rates. This report documents the results of modeling and simulation of tests from the Shutdown Heat Removal Test program to support validation of Argonne’s SAS4A/SASSYS-1 fast reactor safety analysis code. SHRT-17 and SHRT-6 were protected loss of flow tests where a loss of electrical power to all sodium coolant pumps was simulated to demonstrate the effectiveness of natural circulation cooling characteristics. SHRT-45R, SHRT-39, and SHRT-43R were unprotected loss of flow tests where the control rod scram function of the plant protection system was disabled to demonstrate the effectiveness of EBR-II’s passive reactivity feedbacks. BOP-301 and BOP-302R were unprotected loss of heat sink tests that demonstrated how reactivity feedback effects driven by changes to the core inlet temperature can shut down the fission process. PICT-5/6 demonstrated how core power could be increased and decreased via changes in the intermediate sodium and feedwater flow rates. This validation activity leverages modeling and simulation efforts that originated under an International Atomic Energy Agency Coordinated Research Project for benchmark analysis of the EBR-II Shutdown Heat Removal Tests. The SAS4A/SASSYS-1 models originally developed for the CRP have been modernized to utilize new code features and modeling practices. Differences between the predicted and measured test data were explored and the causes of these differences were identified as being due to modeling approximations, uncertainty in transient component behavior, and instrumentation uncertainties. Overall, it was concluded that for all tests simulated there was good agreement between the flow, power, and temperature predictions and the measured data.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

FY23 Report on Water NSTF Testing at Two-Phase Conditions: Off-normal Scenarios

Under support from the Department of Energy (DOE) and the Office of Advanced Reactor Technologies (ART), a large-scale test facility has been constructed at Argonne National Laboratory to generate NQA-1 qualified validation data for passive decay heat removal systems in advanced reactors. The Natural convection Shutdown heat removal Test Facility (NSTF) reflects key features of a ½ scale, water-based, Reactor Cavity Cooling System (RCCS) and is intended to study the behavior, bound performance, and ultimately guide design decisions for passive decay heat removal systems for advanced reactors. In addition to the experimental activities detailed in this report, a supportive computational modeling effort is on-going which has been demonstrated to significantly strengthen the experimental program while also improving accuracy of the computer models. Together these create a mutually beneficial relationship integral to meeting the overall program objective of examining the heat removal performance of the RCCS concept. This report details the experimental activities and upgrades performed during the program’s fifth year of water-based operation. The theme of this year of testing was examining off-normal scenarios. In practice, that meant examining scenarios with blockages or other design basis conditions. From a maintenance and capability standpoint that meant assessing valving options for implementing blockages, assessing drain and refill capabilities, and ensuring in all cases that operators could safely, efficiently, and repeatably bring the facility to an off-normal condition and return it to the normal operating state. In one notable case, no solution existed, nor was a solution commercially available, that met the facility needs for implementing blockages within the two-phase region of the chimney. A valve and feedthrough were custom-designed for NSTF to operate submerged in saturated water while being safely actuated from outside the tank. The fifth year of testing included eight matrix tests consisting of 162 hours of active heating, 9,735 kWh of electrical heating, with seven tests classified as Accepted per NQA-1 and one as Trending. All matrix tests were performed at two-phase flow conditions. The power parametric series from previous years was extended to include another scenario with a decay load equivalent to 1.75 MWt, full scale, further resolving the system flow oscillation response as a function of input power. A depletion test was performed to extend previous work and examine the system’s approach to stagnation and geysering that were not previously observed. This test began at an initial inventory level of 50%, prototypic power of 2.1 MWt, and employed an accelerated drain of 0.75 gpm plus boiloff until stagnation conditions were achieved and multiple geysering events were recorded. Further exploring the geysering phenomenon was a separate effects test examining static boiling in the risers and chimney. This static boiling test was performed at 48 kWe, a higher power than testing in the previous year, and included enhancements to the drain system to remove inventory in a better-controlled and more reliable manner. Two tests were performed, at prototypic conditions of 1.4 MWt and 2.4 MWt, respectively, examining the system response to throttled conditions in the singlephase region of the piping. A ball valve immediately before he riser inlet header was increasingly throttled, progressing the system through a repeatable pattern of two-phase oscillations and stable regimes before ultimately inducing stagnation and geysering. Concluding the year, two tests were performed at baseline conditions of 70% initial inventory level and 2.1 MWt of prototypic decay heat to examine both repeatability and the response to throttling within the two-phase region, at the inventory tank inlet using the custom valve mentioned above. The first such test repeated transient operating conditions and revealed significant sensitivity t

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

RELAP5-3D Pre-test Prediction for High Temperature Test Facility Test PG-26

The RELAP5-3D computer code has been used to perform a pre-test prediction for Test PG-26 in the High Temperature Test Facility at Oregon State University. Test PG-26 will simulate a pressurized conduction cooldown transient following a trip of the primary coolant system gas circulator. The facility is initialized with a steady-state power of 700 kW and prototypic core inlet and outlet helium coolant temperatures of 259 and 687°C, respectively. Sensitivity calculations addressed the flow coastdown time, the reactor cavity cooling system flow rate and temperature, and decay power.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of a point kinetics subroutine for Molten Salt reactors in RELAP5-3D

RELAP5-3D has historically focused on accurate modeling of design-basis and beyond-design-basis accidents in solid fuel light-water reactors. The assumption used in solid fuel reactors that delayed neutron precursors remain at the location in which they were produced is inherently incorrect for a molten salt reactor with flowing fuel. Therefore, new methods for modeling MSR kinetics were required. Subroutine used in RELAP5-3D were updated to analyze point kinetics in a molten salt reactor during both steady state and transient analyses. The phenomena related to MSR kinetics that were added to RELAP5-3D include arrays to store previous values for independent and dependent variables, arrays to add terms to existing kinetics equations, and a new reactivity bias term. A custom MATLAB assessment code was used to establish a suite of verification tests. This capability is undergoing final documentation and testing for public release with a future version of RELAP5-3D.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SAS4A/SASSYS-1 Commercial Grade Dedication Example Report for a Generic Sodium Pool-Type Fast Reactor Application

In the U.S., a key component of the commercialization of advanced reactors is completion of a license application, which must ultimately be approved by the Nuclear Regulatory Commission (NRC). The approval of the license application by the NRC is contingent on satisfactory demonstration of the design basis and the response of the advanced reactor design to transient and accident scenarios using accepted codes and methods. This report describes the qualification and dedication requirements that the advanced reactor safety analysis system software SAS4A/SASSYS-1 are expected to need to fulfill to be used for sodium-cooled pool-type fast reactor licensing. The qualification and dedication requirements are identified through performance critical characteristics and evaluation model acceptance criteria representative of the advanced reactor design considered for licensing. This document captures, additionally, the verification process developed to demonstrate that the software fulfills the qualification and dedication requirements for a generic sodium-cooled pool-type fast reactor as part of the commercial grade dedication process. Like most software that has primarily existed in the research and development space, the most significant challenge facing SAS4A/SASSYS-1 for use in a licensing framework is the availability of a documentation basis describing the code pedigree. SAS4A/SASSYS-1 has been used for licensing of the fast flux test facility (FFTF) and the JOYO sodium-cooled fast reactor in Japan, as well as the design of the CRBR Plant. However, the historical verification and validation (V&V) activities supporting SAS4A/SASSYS-1 development do not align with modern software quality assurance (SQA) and V&V requirements. Two approaches to use of SAS4A/SASSYS-1 in a commercial licensing framework have been identified: commercial-grade dedication (CGD) and software qualification. The methods and requirements prescribed in the ASME NQA-1-2008/2009 Standard and Regulatory Guide 1.203 on the evaluation model development and assessment process (EMDAP) have been used as guidance to define the CGD and qualification processes, respectively. A qualification and dedication requirements matrix has been developed which utilizes fundamental software verification. In this process, software verification is defined as a software quality process aimed at defining software requirement specifications, developing software design documentation, and performing and documenting acceptance testing of the code against requirements. A key element of software qualification and dedication includes determination of software acceptance with respect to critical characteristics relevant to the functional requirements of the software. To assist with identification of cross-cutting transient phenomena and functional requirements, domestic SFR vendor designs have been reviewed to identify a reference SFR design. For this report, the reference design is defined as a pool-type reactor with metal alloy fuel, a liquid-metal intermediate heat transport system, and passive decay heat rejection systems. Given this reference, a series of high-level cross-cutting phenomena was identified for a general class of single-fault undercooling or reactivity insertion transients that scopes the design basis space, with the goal of assisting with prioritization of documentation development efforts for key transient models in SAS: 1) Reactivity feedback response prior to scram; 2) System-wide thermal inertia; 3) Transition in natural circulation flow regime in heat removal systems; 4) Decay heat generation; 5) Steady-state fuel characterization; 5) Clad/fuel behavior at elevated temperatures; 6) Point kinetics and decay heat; 7) Pump coastdown behavior; 8) Core flow redistribution in loss of forced convection; 9) Pool stratification. As a demonstration of CGD of SAS4A/SASSYS-1 for a sodium pool reactor, a software qualification and dedication gap analysis as it relates to code documentation has been performed. This effort leverages the framework established as part of the SAS4A/SASSYS-1 SQA Program. This CGD demonstration provides a framework that vendors can build upon to demonstrate the applicability of the SAS4A/SASSYS-1 software for licensing a sodium-cooled pool-type fast reactor.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SAS4A/SASSYS-1 VERSION 5.2 SAFETY ANALYSIS CODE SYSTEM

SAS4A/SASSYS-1 is a software simulation tool used to perform deterministic safety analysis of anticipated events as well as design basis and beyond design basis accidents for advanced nuclear reactors. This software can be used to assess the safety of a prescribed reactor design, but it cannot be used to configure a design to meet targeted performance objectives. Detailed, mechanistic models of steady-state and transient thermal, hydraulic, kinetic, and mechanical phenomena are employed to describe the response of the reactor core, the reactor primary and secondary coolant loops, the reactor control and protection systems and the balance-of-plant to accidents caused by changes in coolant flow, oss of heat rejection, or reactivity insertion. The consequences of single and double-fault accidents can be modeled, including fuel and coolant heating, fuel and cladding mechanical behavior, core reactivity feedbacks, coolant loop performance including natural circulation, and decay heat removal. Analyses are typically terminated upon demonstration of reactor and plant shutdown to permanently coolable conditions or upon violation of design basis margins. The objective of the analysis is to quantify accident consequences as measured by the transient behavior of system performance parameters, such as fuel and cladding temperatures, reactivity, and cladding strain. Originally developed for analysis of sodium cooled reactors with oxide fuel clad by stainless steel, the models In SAS4A/SASSYS-1 were subsequently extended and specialized to metallic fuel clad with advanced alloys and to several other coolant options including lead and LBE. METHOD OF SOLUTION: Each subassembly in the reactor core is represented with single or multiple-pin models. One channel represents one or more fuel pins and many channels are employed for a whole-core representation. Heat transfer in each pin is modeled with a two-dimensional (r/z) heat conduction equation. Single and two-phase coolant thermal-hydraulics are simulated with a unique, one-dimensional (axial) multiple-bubble liquid metal boiling model. The transient fuel and cladding mechanical behavior models are integrated with fission product production,release, and transport models. UNIQUE FEATURES: The physical models in SAS4AJSASSYS-1 are highly detailed 1umerical representations of reactor accident conditions based on extensive laboratory and test reactor results. The models are specialized to liquid metal (sodium) cooled fast reactors with oxide or metallic fuel clad with stainless steel.«

Fanning, Thomas↗

Unstructured mesh-based multi-physics reactor transient simulation with iMC code

In this study, we present a time-dependent Monte Carlo simulation result about a complex fuel-loaded light water reactor system with thermal-hydraulic feedback using the KAIST iMC code. The intra-pin temperature distribution is calculated based on Monte Carlo-tallied detailed power distribution and the finite element heat transfer method. The temperature effect of fuel, absorber, and coolant are adequately reflected into the dynamic response by the on-the-fly Doppler broadened cross-section correction. For the time-dependent Monte Carlo transport simulation, the predictor-corrector quasi-static Monte Carlo method is used for this study. We tested the coupled analysis framework with a 17-by-17 fuel assembly loaded with the centrally-shielded burnable absorber (CSBA) fuel element. The temperature feedback effect on the material cross-section and the moderator density incurred negative reactivity in response to the external positive reactivity insertion, showing the inherent stability of the reactor system. The pin-wise power and temperature change during the system transient are presented and discussed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Application of Dynamical System Scaling for Accelerated Fuel Qualification Efforts

There are considerable ongoing research and testing campaigns to qualify new fuel designs such as metallic fuels for advanced reactor designs and the Accident Tolerant Fuel (ATF) campaign for light water reactors (LWR). The typical research and development lifecycle needed to qualify a nuclear fuel design, under ideal conditions, can take up to 20-25 years which limits the ability for new fuels to make fast deployments into commercial, test, and research reactors. While there are several efforts to accelerate nuclear fuel qualification through advanced modeling coupled with state-of-the-art experiments, there is not yet a framework to methodically quantify and rank distortions occurring in experimental test specimens needed to validate nuclear fuel performance codes. This study uses the Dynamical System Scaling (DSS) methodology to quantify transient scaling distortions that occur over experiment and simulated transients. DSS analysis metrics provide a researcher with several tools and information embedded within test data to identify dominant phenomena, associated timescales, and quantify a transient?s overall dynamic distortion. This is demonstrated with separate analyses of the SETH-C and CHF-SERTTA thermal-hydraulic experiments in the TREAT facility at Idaho National Laboratory. The outcome of this work is a scaling and data analysis approach to account for the influence a scaled fuel test specimen?s geometric and temporal distortions have on its ability to be representative of the full-scale design.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Transient behavior of a scaled RCCS test facility under postulated fault and accident scenarios

Tests were performed on the Natural convection Shutdown heat removal Test Facility (NSTF) to simulate design basis accident and postulated fault scenarios. Residing at Argonne National Laboratory, the NSTF stands nearly 26-m in total height and reflects a ½ scale reactor cavity cooling system (RCCS) for high temperature gas cooled reactors. The following manuscript details three test conditions performed on the experimental test facility. The first simulated the reactor pressure vessel (RPV) boundary condition during depressurized conduction cool down accident with small primary leak, and was repeated during both winter and summer seasons. The second examined a short-circuit break between the inlet and outlet flow paths, and was performed in three incremental stages of nominal flow area break size. The third and final test case studied system behavior with varying amounts of cooling channel blockages, up to and including 50% flow areas. Nominal component temperatures, heat removal performance, and system stability will be presented to characterize the behavior at these conditions.

decay heat removal↗

Experiment to Investigate the On-set of Transient Fission Gas Release Under Simulated LOCA Conditions

Continuing efforts to better understand the phenomenon of transient fission gas release in irradiated commercial light water reactor fuel undergoing a simulated loss of coolant accident (LOCA) will be discussed in this work. During heating associated with LOCA conditions there is an additional release of fission gas beyond what is typically released during steady state operation. The exact timing of this release could impact the cladding balloon and rupture as the LOCA progresses in an actual accident. Recent experiments performed on the upgraded Severe Accident Test Station at Oak Ridge National Laboratory have expanded the current assessment of transient fission gas release. This system evaluates fission gas release by sweeping fission gas out of the LOCA test furnace and into cryogenically cooled cold traps where radioactive noble gas fission products are measured by gamma spectrometry. Additionally, the sweep gas can be monitored by a gas mass spectrometer to provide additional data on noble gas release and changes in the sweep gas atmosphere during heating. Several different conditions have been evaluated that explored the response of irradiated fuel to different thermal ramp conditions and different overpressure conditions. This further confirmed the impact of an overpressure in suppressing transient fission gas release. Further experiments are planned to evaluate the on-set temperature of transient fission gas release under a known overpressure. This test will progressively step through different temperature conditions while maintaining hydrostatic pressure on the fuel that is representative of high burnup fuel conditions. The available results from this type of testing will be discussed. Post-test microscopy will be compared to other transient fission gas release and standard LOCA tests to further understand the microstructural source of transient fission gas release.

Harp, Jason [ORNL] (ORCID:0000000253458440)↗

Behavior of an air-cooled thermosiphon during a non-air gas ingress event

Here, this study investigates the transient response of an air-cooled thermosiphon subjected to a sudden non-air gas ingress event. Results presented are from experimental testing conducted on a large-scale thermal hydraulic facility that examines heat removal performance of the Reactor Cavity Cooling System (RCCS) concept, a passive safety system for advanced nuclear reactors. Relying on buoyancy driven natural circulation flow, these systems feature a series of riser standpipes and coupled chimney network that provide a pathway for heat rejection to the atmosphere. In this work, the facility was modified to allow a transition of the draft intake from normal ambient air, to draft intake from an open-top volume containing high purity argon. Testing began by establishing normal operation and allowing the facility to reach steady-state thermal hydraulic flow conditions with natural air draft. The transitioned sequence was then initiated which simultaneously changed the inlet boundary from open air to a pathway from the quiescent argon volume. This event caused 1,200 cu-feet of the heavy gas, twice the internal volume of total facility flow path, to be drawn into the inlet plenum and ingress into the heated riser standpipes. With the upper chimney network still containing residual air, there was insufficient density difference to maintain buoyancy driven natural circulation. After a period of only 90 s past the ingress event, the facility experienced complete flow stagnation before entering an extended period of severely degraded system flow. Due to the cessation of bulk fluid movement and subsequent failure of its heat removal function, fluid and structural temperatures began to rise sharply. Re-circulation patterns developed within the multiple parallel riser standpipes, where hot gas near the outlets was observed to travel downward and re-enter the inlet of adjacent channels. After approximately 18-minutes, fluid temperatures and their associated density difference rose to a level sufficient to allow reestablishment of buoyancy driven system flow, and ultimately, recovery of facility operation to normal behavior.

42 ENGINEERING↗