Search NASA⌕ Search

SEARCH · Search NASA

Results for “UTILITY INTERCONNECTIONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

On the Path to SunShot - Emerging Issues and Challenges with Integrating High Levels of Solar into the Distribution System

Wide use of advanced inverters could double the electricity-distribution system’s hosting capacity for distributed PV at low costs—from about 170 GW to 350 GW (see Palmintier et al. 2016). At the distribution system level, increased variable generation due to high penetrations of distributed PV (typically rooftop and smaller ground-mounted systems) could challenge the management of distribution voltage, potentially increase wear and tear on electromechanical utility equipment, and complicate the configuration of circuit-breakers and other protection systems—all of which could increase costs, limit further PV deployment, or both. However, improved analysis of distribution system hosting capacity—the amount of distributed PV that can be interconnected without changing the existing infrastructure or prematurely wearing out equipment—has overturned previous rule-of-thumb assumptions such as the idea that distributed PV penetrations higher than 15% require detailed impact studies. For example, new analysis suggests that the hosting capacity for distributed PV could rise from approximately 170 GW using traditional inverters to about 350 GW with the use of advanced inverters for voltage management, and it could be even higher using accessible and low-cost strategies such as careful siting of PV systems within a distribution feeder and additional minor changes in distribution operations. Also critical to facilitating distributed PV deployment is the improvement of interconnection processes, associated standards and codes, and compensation mechanisms so they embrace PV’s contributions to system-wide operations. Ultimately SunShot-level PV deployment will require unprecedented coordination of the historically separate distribution and transmission systems along with incorporation of energy storage and “virtual storage,” which exploits improved management of electric vehicle charging, building energy systems, and other large loads. Additional analysis and innovation are neede

14 SOLAR ENERGY↗

State Strategies for Valuing Distributed Energy Resources in Cost-Effective Locations

The deployment of Distributed Energy Resources (DERs), small-scale electricity generation sources or controllable loads connected to the distribution system or a facility served by the distribution system, can have wide-ranging and positive impacts for the electricity grid. Interconnecting a DER in a high-value location on the grid can unlock benefits beyond those that accrue to the off-taker or asset owner. When DERs are deployed optimally, not only can the individual consumer benefit, but the local utility, the electricity system, and other ratepayers can benefit as well. By engaging in locational DER planning, states can help protect their communities and ratepayers and can help ensure the reliability and resilience of the electricity system. This report explores states' role in better integrating locational value into DER siting and development. It first outlines some of the benefits that can be achieved through the deployment of DERs in high-value locations. It then looks at state policy and regulatory roles and the tools states can use to influence the location of DER development. The report next examines the challenges of locational DER planning, with a particular focus on the challenges that states face in influencing the location of DER development. It highlights three case studies from states that engaged in locational DER planning through the Multistate Initiative to Develop Solar in Locations that Provide Benefits to the Grid and then presents several lessons learned from these efforts. The final section of this report summarizes some recent publications related to locational value of DERs in the form of an abbreviated literature review.

14 SOLAR ENERGY↗

Reconstructing a hydrogen-driven microbial metabolic network in Opalinus Clay rock

A significant fraction (~ 20%) of microbial life is found in the terrestrial deep subsurface, yet the metabolic processes extant in those environments are poorly understood. Here we show that H 2 , injected into the Opalinus Clay formation in a borehole located 300 meters below the surface, fuels a community of microorganisms with interconnected metabolisms. Metagenomic binning and metaproteomic analysis reveal a complete carbon cycle, driven by autotrophic hydrogen oxidizers. Dead biomass from these organisms is a substrate for a fermenting bacterium that produces acetate as a product. In turn, complete oxidizer heterotrophic sulfate- reducing bacteria utilize acetate and oxidize it to CO 2 , closing the cycle. This metabolic reconstruction sheds light onto a hydrogen-driven carbon cycle, and a sunlight-independent ecosystem in the deep subsurface.

54 ENVIRONMENTAL SCIENCES↗

Circulating Current Reduction of Back-to-Back MMC with Advanced Grid-Support Functionalities for Medium-Voltage Applications

A Lyapunov energy function based circulating current reduction scheme for a back to back modular multilevel converter based system for a microgrid application has been proposed in this digest. In order to ensure no circulating or zero sequence currents within the modules, the dynamics from one leg of the converter to the other are evaluated. A Lyapunov energy function is then developed and utilizing the circulating current dynamics of the converter the overall control law is implemented. In this digest a decentralized hierarchical control architecture has been implemented for the main current control; where the outer loop or the central controller implements the higher level grid interconnection functions as per IEEE 1547-2018 standards and the inner loop based on synchronous reference frame implements the current control architecture. The inner loops' outputs are the commanded converter voltages either on either side which are augmented by the Lyapunov energy function based circulating current suppression architecture. To evaluate the efficacy of the overall system, the overall system is modeled around a 300kVA back to back SiC multilevel modular converter used as a direct-connected medium voltage (MV) grid intertie based on MATLAB/Simulink domain. Several important case studies are presented in this paper to prove the effectiveness of the proposed architecture. case study results are presented.

circulating current↗

FNET/GridEye: A Tool for Situational Awareness of Large Power Interconnetion Grids

This paper gives an overview of a wide-area measurement system deployed at the distribution level: FNET/GridEye, which consists of hundreds of sensors, communication and a data center. The sensors are utilized to take frequency, voltage phase angle and magnitude measurements from the ordinary 110 or 220V outlets in offices or residential houses. These measurements are continuously transmitted to the data center via Internet. Many applications have been implemented to monitor large-scale interconnected power grids, and interpret grid operation status to improve system operators' situational awareness capability. Some representative online and offline applications are presented in this paper, as well as several recently developed new applications.

Zhu, Lin↗

Small Hydropower Interconnection Best Practices Guidelines and Templates

The process for development of a hydropower project can be a convoluted and lengthy process involving numerous federal, state, and local agencies and encompass a plethora of stakeholders that other renewable project development processes may not have to consider. Additionally, the process may vary depending on who the owner/operator is, such as private, nonutility companies; private utility companies; municipalities; electric cooperatives; private citizens; and state and federal government agencies.

13 HYDRO ENERGY↗

Valuing Resilience Benefits of Microgrids for an Interconnected Island Distribution System

Extreme climate-driven events such as hurricanes, floods, and wildfires are becoming more intense in areas exposed to these threats, requiring approaches to improve the resilience of the electrical infrastructure serving these communities. Long-duration outages caused by such high impact events propagate to economic, health, and social consequences for communities. As essential service providers, electric utilities are mandated to provide safe, economical and reliable electricity to their customers. The public is becoming less tolerant to these more frequent disruptions, especially in view of technological advances that are intended to improve power quality, reliability and resilience. One promising solution is state-of-the-art microgrids and the advanced controls employed therein. This paper presents and demonstrates an approach to technoeconomic analysis that can be used to value the avoided economic consequences of grid resilience investments, as applied to the islands of Vieques and Culebra in Puerto Rico. This valuation methodology can support policies to incorporate resilience value into any investment decision-making process, especially those which serve the public interest.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Security Enhancements for Distributed Energy Resource Systems Interconnected with Distribution Networks: Final Technical Report

The revised IEEE 1547 Standard defines new complex communication-adjustable voltage and frequency regulation and ride-through characteristics, while maintaining the general antiislanding requirement for unintentional islanding situations. Unintentional islanding is prohibited while intentional islanding is specifically allowed, thus effectively enabling microgrid operation mode. Further, IEEE 1547-2018 Standard introduces new requirements in terms of interoperability so that the DER plant/circuit segments may be seamlessly integrated with the utility networks but at the same time become vulnerable to a cyber-attack. Traditional cybersecurity measures including encryption, authentication and role-based access control may not be fully implementable to all communication protocols specified in the IEEE 1547 Standard. Therefore, in this project we have identified, researched, implemented and tested several cyberphysical approaches that rely mostly on the behavior of the DER circuit and may help with validating the incoming command and control action potentially coming through an insecure communications channel. Additionally, we have built semantic models and communications profiles for DER facilities and have implemented lightweight IEC 61850 based publisher-subscriber GOOSE messaging mechanism, with security extensions in terms of authentication and encryption. The project proposed information models for integration into UCA OpenFMB 2.0 profiles focusing on grid code compliance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Understanding DERMS

With the rapid deployment of distributed energy resources (DER), there is a high level of interest in how these devices can be integrated with utility operations at all levels for management and monitoring purposes. This integration is challenging in that the number of devices is high and that ownership is often that of a customer or third party. Industry stakeholders first began to address DER integration by identifying and standardizing the functions that individual DER can perform autonomously, a distributed manner. Device-level functions like “voltage ride-through”, “volt-var”, “frequency-watt”, and “dynamic reactive current” were designed and documented and are now supported by communication standards and grid codes worldwide, making grid-supportive capabilities mandatory for new interconnections. This was a first step. A necessary step, but not sufficient to achieve end-to-end integration of DER with the grid. A substantial gap was recognized between the granular controls of individual DER and the type of organized services needed for grid support, integration with distribution management systems (DMS) and grid operations. In 2012, stakeholders began working to define a common set of grid-supportive services and means to integrate large quantities of DERs into utility systems in a way that is practical, sustainable and extensible. Because multiple parties could be involved; utilities, DMS providers, DER aggregators and facility/microgrid controller providers are working together.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Exploring the interoperability of remote GPGPU virtualization using rCUDA and directive-based programming models

Directive-based programming models, such as OpenMP, OpenACC, and OmpSs, enable users to accelerate applications by using coprocessors with little effort. These devices offer significant computing power, but their use can introduce two problems: an increase in the total cost of ownership and their underutilization because not all codes match their architecture. Remote accelerator virtualization frameworks address those problems. In particular, rCUDA provides transparent access to any graphic processor unit installed in a cluster, reducing the number of accelerators and increasing their utilization ratio. Joining these two technologies, directive-based programming models and rCUDA, is thus highly appealing. In this work, we study the integration of OmpSs and OpenACC with rCUDA, describing and analyzing several applications over three different hardware configurations that include two InfiniBand interconnections and three NVIDIA accelerators. Our evaluation reveals favorable performance results, showing low overhead and similar scaling factors when using remote accelerators instead of local devices.

97 MATHEMATICS AND COMPUTING↗

Hollow fiber-supported designer ionic liquid sponges for post-combustion CO2 scrubbing

A proof of concept study for a new type of carbon capture system is considered for post-combustion CO2 capture based on porous hollow fiber sorbents with ionic liquids sorbed in the cell walls of the fiber. This study proves that delicate morphological features in the open-celled porous wall can be maintained during the infusion process. Mixtures of task specific ionic liquid (i.e. [BMIM][Tf2N]) and superbase (i.e. DBU) were loaded into polyamide-imide (PAI) fibers by a so-called two-step non-solvent infusion protocol. In the protocol, methanol carries ionic liquids into the pore cell walls of hollow fibers and then hexane carries superbase to create an efficient CO2 sorbent. Our ionic liquid/superbase impregnation technique overcomes a serious increase in mass transfer resistance upon reaction with CO2, thereby allowing its large scale utilization for post-combustion CO2 capture. The investigation on the effect of different pore former additives (different molecular weights of polyvinylpyrrolidone, lithium nitrate, and their mixtures) suggested that a large molecular weight of PVP (M-w; 1300k) including dope composition produces highly interconnected open cell pore structures of PAI hollow fibers. Lastly, a lumen side barrier layer was successfully formed on the bore side of neat PAI fibers by using a mixture of Neoprene (R) with crosslinking agents (TSR-633) via a post-treatment process. The lumen layer will enable heat removal from the fiber sorbents during their application in rapid thermal swing cycling processes. (C) 2012 Elsevier Ltd. All rights reserved.

Lee, JS↗

Hydrogen Based Energy Storage System for Integration with Dispatchable Power Generator (Phase I Feasibility Study)

This project examined the feasibility of integrating hydrogen generation, storage, and use as a means to decarbonize campus activities while retaining the ability to utilize the existing natural gas fired combined heat and power system installed at the campus of the University of California @ Irvine. Analysis of specific potential sites for the integrated system identified a location adjacent to the existing central plant which resulted in minimization of interconnections. A strategy based on use of commercial electrolyzers and gas storage was identified. Primary technology advancements are required for the gas turbine to accommodate higher levels of hydrogen and the integrated controls. The project indicated challenges for adopting the proposed strategy with the present rates and constraints. The availability of a relatively low-cost biogas resource by the campus already decarbonizes the gas turbine to some extent. In the absence of this resource, procurement of electricity directly from large scale renewable operations could facilitate lower electricity costs. Additional solar resources on campus could also help in this regard. The gas turbine cannot be operated below 50% capacity due to air permit constraints. Using the otherwise curtailed gas turbine operation to generate hydrogen via electrolysis by consuming natural gas is not highly efficient and therefore leads to relatively high costs of electricity returned. Several scenarios demonstrate potential for effective decarbonization, yet most involve lower and lower capacity factor for the legacy gas turbine which is not a good use of the asset. A small gas turbine output with higher efficiency operation would help. As would ability to export electricity to the grid. Certainly current rate structures and operational scenarios are less attractive than other possible future structures which should be pushed for in the future.

03 NATURAL GAS↗

Exploration of Resource and Transmission Expansion Decisions in the Western Renewable Energy Zone Initiative

Building transmission to reach renewable energy (RE) goals requires coordination among renewable developers, utilities and transmission owners, resource and transmission planners, state and federal regulators, and environmental organizations. The Western Renewable Energy Zone (WREZ) initiative brings together a diverse set of voices to develop data, tools, and a unique forum for coordinating transmission expansion in the Western Interconnection. In this report we use a new tool developed in the WREZ initiative to evaluate possible renewable resource selection and transmission expansion decisions. We evaluate these decisions under a number of alternative future scenarios centered on meeting 33% of the annual load in the Western Interconnection with new renewable resources located within WREZ-identified resource hubs. Of the renewable resources in WREZ resource hubs, and under the assumptions described in this report, our analysis finds that wind energy is the largest source of renewable energy procured to meet the 33% RE target across nearly all scenarios analyzed (38-65%). Solar energy is almost always the second largest source (14-41%). Solar exceeds wind by a small margin only when solar thermal energy is assumed to experience cost reductions relative to all other technologies. Biomass, geothermal, and hydropower are found to represent a smaller portion of the selected resources, largely due to the limited resource quantity of these resources identified within the WREZ-identified hubs (16-23% combined). We find several load zones where wind energy is the least cost resource under a wide range of sensitivity scenarios. Load zones in the Southwest, on the other hand, are found to switch between wind and solar, and therefore to vary transmission expansion decisions, depending on uncertainties and policies that affect the relative economics of each renewable option. Uncertainties and policies that impact bus-bar costs are the most important to evaluate carefully, but factors that impact transmission costs and the relative market value of each renewable option can also be important. Under scenarios in which each load zone must meet 33% of its load with delivered renewable energy from the WREZ-identified resource hubs, the total transmission investment required to meet the 33% west-wide RE target is estimated at between $22 billion and $34 billion. Although a few of the new transmission lines are very long - over 800 miles - most are relatively short, with average transmission distances ranging from 230-315 miles, depending on the scenario. Needed transmission expenditure are found to decline to $17 billion if wide use of renewable energy credits is allowed; consideration of renewable resources outside of WREZ-identified hubs would further reduce this transmission cost estimate. Even with total transmission expenditures of $17-34 billion, however, these costs still represent just 10-19% of the total delivered cost of renewable energy.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Experiences from Field Testing for Black Start of a Run-of-the-river Hydropower Plant in Idaho Falls Power Distribution Grid

Idaho Falls Power (IFP) utility has local generation portfolio comprising of 56.3MVA of run-of-the-river (ROR) hydropower that can serve typically 25%-30% of the total load demand. The remaining load is served by importing power from Bonneville Power Administration through two Pacificorp transmission interconnections. In case of emergencies (power disruption or directed load reduction), the capability to island from transmission grid and stably serve critical loads in the IFP distribution grid can be a huge advantage. In this direction, the capability to black start with ROR is an essential requirement, and a challenge due to limited dispatchability and requires re-tuning of hydro-governor and excitation system controls. This paper presents the field experience from the testing done for black start of 8.9 MW ROR hydro plant in the IFP distribution grid using an adjustable load bank in December 2017. The lessons from the successful black start testing is presented along with test results to establish the potential value and requirements to develop black start capability with a ROR hydro plant.

13 HYDRO ENERGY↗

Inertia estimation for power grids: A review of methods, challenges, and future prospects

The electric power grid is undergoing a significant transformation, shifting from traditional synchronous generators to inverter-based resources (IBRs) such as solar photovoltaics, wind turbines, and energy storage systems. This evolution leads to a reduction in system inertia, a critical attribute for maintaining frequency stability in response to disturbances. Consequently, the ability to monitor and estimate system inertia has become increasingly essential. This paper provides a comprehensive review of existing inertia estimation methodologies, analyzing them from multiple perspectives, including the types of data utilized, underlying estimation principles, operational modes, and system-wide applicability. A comparative summary table is included to distill commonalities and key characteristics across various studies. In addition, the paper examines practical implementations of inertia estimation across several major power systems worldwide, including the U.S. interconnections, the Nordic power system, and the U.K. grid. Key challenges are identified, particularly in estimating contributions from virtual inertia sources and load-induced inertia in increasingly converter-dominated networks. To address these emerging challenges, the paper proposes an integrated framework for real-time inertia estimation and monitoring. This framework encompasses critical components such as data acquisition, inertia estimation from both synchronous and non-synchronous sources, load-induced effects, optimization techniques, forecasting, and virtual inertia scheduling. Collectively, these elements enable dynamic, system-wide monitoring and adaptive control of grid inertia.

Inertia estimation↗