Search NASA⌕ Search

SEARCH · Search NASA

Results for “VASCULAR DISEASES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Technical and Imaging Outcomes from the UK Registry of Prostate Artery Embolization (UK-ROPE) Study: Focusing on Predictors of Clinical Success

Introduction: The UK Registry of Prostate Artery Embolization (UK-ROPE) was a prospective, multicentre study comparing PAE against surgical therapies for symptomatic benign prostatic hyperplasia (BPH). A wealth of data was collected supplementary to the main study outcomes which provide a snapshot of UK PAE practice. We aimed to interpret these data in the hope of providing insight into factors which affect clinical outcome and radiation dose. Methods: 216 patients (mean age 66, mean IPSS 21.3) undergoing PAE at 20 British centres from July 2014 to January 2016 were prospectively followed up to 12 months with retrospective analysis of the data. Technical outcome was evaluated based on procedural and fluoroscopy times, skin dose and dose area product (DAP). Clinical outcome was evaluated through collection of Qmax, IPSS reduction and prostate volume reduction. Multiple analysis of variance (MANOVA) was used to assess the significance of various patients and procedural factors on clinical outcome and patient dose. Results: Significant predictors of technical outcome which affected patient skin dose included severity of CTA-detected atheroma (p < 0.001), the practitioner (p < 0.001) and use of protective coil embolization (p = 0.019). Predictors of clinical outcome included initial prostate size (dichotomized into groups > 80 ml and = <80 ml, d = 1, p = 0.0138), embolic agent (spherical particles < 300 nm performed best, p = 0.01) and number of arteries embolized (IPSS reduction of 32.9% in unilateral PAE versus 54.4% for bilateral PAE, p = 0.026). Conclusion: We have identified several important factors which are associated with improved clinical outcome and increased patient dose which we hope will facilitate optimal patient selection and encourage improved embolization technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Balloon Plasty for Thoracic Duct Occlusion in a Patient with Chylothorax and Chylous Ascites

A patient developed abdominal distension, dyspnea, and nausea due to chylothorax and chylous ascites 1 month after bruising her back. Lymphangiography was unable to identify the site of lymph leakage, and lymphatic duct embolization was impractical. However, lymphangiography showed occlusion of the thoracic duct. Thus, balloon plasty was performed to restore the patency of the thoracic duct, and the chylothorax and chylous ascites improved. Although embolization of the thoracic or lymphatic ducts has been reported as a treatment for lymphorrhea, it is impractical if the lymphatic duct responsible for leakage cannot be identified. In such a case, balloon plasty of the occluded thoracic duct to lower the pressure in the peripheral lymphatic ducts was successfully performed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Feasibility of Percutaneous Intrahepatic Split by Microwave Ablation (PISA) After Portal Vein Embolization for Hypertrophy of Future Liver Remnant: The Radiological Stage-1 ALPPS

PurposeTo assess the feasibility of radiological stage-1 ALPPS, associating liver partition and portal vein ligation for staged hepatectomy, by combining portal vein embolization (PVE) with percutaneous intrahepatic split by ablation (PISA).Materials and MethodsThree patients (mean age 65.0 ± 7.3 years) underwent PVE and PISA. PISA was performed 21 days after PVE by microwave ablation to create a continuous intrahepatic cutting plane. Abdominal CT examinations were performed before and after PVE and PISA. The future liver remnant (FLR) volume was calculated by semiautomatic segmentation, and increase was reported as a percentage of the pre-procedural volume. The FLR/body weight (FLR/BW) ratio was calculated; a ratio greater than 0.8% was considered sufficient for guaranteeing adequate liver function after surgery. The liver function before and after PISA was also evaluated by 99mTc-mebrofenin hepatobiliary scintigraphy. Patients’ laboratory tests, performance status, ability to walk were assessed before and after PVE and PISA procedures.ResultsNo procedure-related complications were recorded. The FLR volume increase in each patient was 42.0, 33.1 and 30.4% within 21 days of PVE and 109.3, 68.1 and 71.7% within 10 days after PISA. The FLR/BW ratios were 0.76, 0.66, 0.63% and 1.13, 0.83, 0.83% after PVE and PISA procedures, respectively. Two patients underwent successful right hepatectomy; in one patient, despite 1.13% FLR/BW, surgery was not performed because of the absolute rejection of blood transfusion due to the patient’s religious convictions.ConclusionRadiological stage-1 ALPPS is a feasible, minimally invasive option to be further investigated to become an effective alternative to surgical stage-1 ALPPS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Balloon-Occluded Carbon Dioxide Gas Angiography for Internal Iliac Arteriography and Intervention

IntroductionThe usefulness of carbon dioxide (CO{sub 2}) gas digital subtraction angiography (DSA) has been reported for patients with renal insufficiency and allergy to iodinated contrast agents. However, CO{sub 2} gas cannot replace the iodinated contrast agent in all cases owing to some disadvantages. We describe balloon-occluded CO{sub 2} DSA (B-CO{sub 2} DSA) as an improved CO{sub 2} DSA procedure for interventions in the internal iliac artery (IIA) region and compare the quality of images obtained using conventional CO{sub 2} DSA and B-CO{sub 2} DSA.Materials and MethodsB-CO{sub 2} DSA-guided embolization was performed for one case of genital bleeding with an acute anaphylactic reaction to the iodinated contrast agent and for three cases of type II endoleaks after endovascular abdominal aortic aneurysm repair with renal dysfunction. A 9-mm occlusion balloon catheter was placed just after the orifice of the IIA. Then, 10–15 ml of CO{sub 2} gas was injected manually via the catheter with and without balloon occlusion. The quality of sequential digital subtraction angiograms was analyzed based on a scoring criterion.ResultsIn all four cases, image quality was improved with B-CO{sub 2} DSA; the poor quality of images without balloon occlusion was because of reflux of the CO{sub 2} gas.ConclusionsB-CO{sub 2} DSA improves the image quality of CO{sub 2} DSA in the IIA region and is useful for vascular intervention. Level of Evidence: Level IV.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transcatheter Arterial Embolization for Postoperative Bleeding Following Abdominal Surgery

PurposeWe aimed to estimate the usefulness of transcatheter arterial embolization (TAE) in patients with postoperative abdominal hemorrhage and to evaluate the effects of pancreatic fistula on clinical outcomes and angiographic findings.Materials and MethodsWe enrolled 22 patients (20 males and 2 females; mean age 63 years; range 25–86 years), who underwent transarterial angiography for postoperative hemorrhage after abdominal surgery. This group corresponded to 28 procedures. Technical and clinical success rates were calculated, and clinical findings and outcomes were compared between patients with and without a pancreatic fistula.ResultsPre-interventional CT was performed in all patients before first angiography, and the location of the bleeding was identified in all but one patient. Active arterial bleeding, identified by extravasation of contrast agent (n = 12), pseudoaneurysm formation (n = 12), and arterial wall irregularity (n = 2) were detected in 28 angiographic procedures, and embolization was performed in 26 instances. Various embolization techniques such as isolation, packing, embolization, and stentgraft implantation were performed. The technical and clinical success rates were 96% (25/26 procedures) and 82% (18/22 patients), respectively. In hemodynamically unstable patients (shock index: heart rate/systolic blood pressure > 1), a 92% (12/13 cases) technical success rate was achieved. There were no significant differences in any evaluated parameters between patients with and without pancreatic fistula.ConclusionTAE is a safe and effective for treating postoperative hemorrhage even in patients with hemodynamic instability and pancreatic fistula. Additionally, pre-interventional CT is useful for effective, consecutive interventions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Efficacy of Automated Supplying Artery Tracking Software Using Multidetector-Row Computed Tomography Images for Emergent Transcatheter Arterial Embolization

PurposeTo assess the reliability of a prototype automated supplying artery tracking software (ASATS) using multidetector-row CT (MDCT) images in emergent TAE.Materials and MethodsConsecutive 53 patients underwent 57 sessions of emergent TAE during 7 months. Twenty-one cases were excluded due to a lack of CT data (n = 12) or negative angiographic findings (n = 9). Remaining 34 sessions of TAE and MDCT images in 32 patients (mean age 62.9 years; age range 37–92 years) were enrolled. ASATS was retrospectively conducted for the identification of supplying arteries which were confirmed with angiography (automated method). Manual modification was added as needed (semi-automated method). Two observers independently reviewed the MDCT images to detect supplying arteries (manual method). Detectability of supplying artery and time to analysis were compared among the automated, semi-automated, and manual methods by both observers.ResultsA total of 64 bleeding sites were demonstrated on angiography. The detectability was 28 (43.8%) for automated method, 53 (82.8%) for semi-automated method, 55 (85.9%) for observer 1, and 58 (90.6%) for observer 2. Detectability of semi-automated method was significantly better than of automated method (P = 0.000) and comparable with manual method by both observers (P = 0.193 and 0.081). Average time to analysis was 185.4 s for automated method, 297.2 s for semi-automated method, 186.2 s for observer 1, and 243.7 s for observer 2.ConclusionASATS has a sufficient ability to identify supplying arteries of bleeding by adding manual modification as needed and can be used for emergent TAE. Level of Evidence: Level 4, Case Control Study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Utility of the Virtual Liver Parenchymal Perfusion Area Using a Commercially Available Workstation in Transarterial Chemoembolization for Hepatocellular Carcinoma

Purpose: To evaluate the accuracy of the virtual liver parenchymal perfusion area using a commercially available workstation and liver analysis software in conventional transarterial chemoembolization (cTACE) for hepatocellular carcinoma (HCC). Materials and Methods: This method was retrospectively applied to 29 treated HCCs in 23 patients. The virtual embolic area (VEA) was estimated based on cone beam computed tomography during hepatic arteriography using a commercially available workstation and liver analysis software by two observer groups (group A: experts; group B: semi-experts). The real embolic area (REA) was defined as the area where iodized oil accumulated on computed tomography at 1 week after cTACE. The REA was estimated by each of the two groups, and the mean REA between the groups (mREA) was used as a standard reference. Agreement of volume and cross-sectional area in three orthogonal planes between the VEA and mREA were analyzed using intraclass correlation coefficients (ICCs) and Bland–Altman plots. Results: The ICCs for volume between VEA and mREA were 0.97 and 0.88 for groups A and B, respectively, and those for cross-sectional area were 0.94 and 0.88 for the axial plane, 0.95 and 0.83 for the coronal plane, and 0.87 and 0.74 for the sagittal plane, respectively. Thus, the overall agreement was excellent, except for the sagittal imaging plane in group B. Conclusion: This method using a commercially available workstation and liver analysis software can be useful for estimating the embolic area in cTACE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Trans-Catheter Aspiration of Systemic Air Embolism Causing Cardiac Compromise During CT-Guided Lung Biopsy, a Potentially Lifesaving Maneuver

Systemic artery embolism is a rare complication of CT-guided lung biopsy. Immediate clinical and radiological recognitions are crucial for rapid intervention and prevention of fatal outcome. Although hyperbaric oxygen is the suggested treatment of mildly symptomatic systemic artery embolization, aspiration of air should be considered as part of the management in cases of cardiac arrest.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Rectal Venous Malformation Treated by Superior Rectal Artery Embolization

A 25-year-old female was referred to the Interventional Radiology Department for investigation and treatment of a rectal venous malformation (RVM) causing large recurrent episodes of rectal bleeding and chronic anaemia. Magnetic resonance imaging (MRI) demonstrated a large venous malformation affecting the rectum, lower pelvis and left thigh. After three failed attempts at injection foam sclerotherapy using fluoroscopic colonoscopy, a multidisciplinary team proposed an embolization procedure of the arterial inflow to the venous malformation. Following discussion with the patient, embolization of the superior rectal arteries was undertaken with immediate on-table fluoroscopic improvement in the RVM. Post-treatment, a significant reduction in bleeding, was reported by day 10 with subsequent return to activities of daily living and full employment. Follow-up MRI at 1 year demonstrated significant reduction in bowel-wall thickening.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Imaging and Endovascular Treatment of Bleeding Pelvic Fractures: Review Article

Pelvic fractures are potentially life-threatening injuries with high mortality rates, mainly due to intractable pelvic arterial bleeding. However, concomitant injuries are frequent and may also be the cause of significant blood loss. As treatment varies depending on location and type of hemorrhage, timely imaging is of critical importance. Contrast-enhanced CT offers fast and detailed information on location and type of bleeding. Angiography with embolization for pelvic fracture hemorrhage, particularly when performed early, has shown high success rates as well as low complication rates and is currently accepted as the first method of bleeding control in pelvic fracture-related arterial hemorrhage. In the current review imaging workup, patient selection, technique, results and complications of pelvic embolization are described.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transcatheter Arterial Embolization of Spontaneous Soft Tissue Hematomas: A Systematic Review

Background: Severe spontaneous soft tissue hematomas (SSTH) are usually treated with transcatheter arterial embolization (TAE) although only limited retrospective studies exist evaluating this treatment option. The aim of this study was to systematically assess the efficacy and safety of TAE for the management of SSTH. Methods: Medline, EMBASE, PubMed and Cochrane Library were searched from inception to July 2017 using MeSH headings and a combination of keywords. Eligibility was restricted to original studies with patients suffering from SSTH treated with TAE. Patients with traumatic hematomas or who were treated with solely conservative or surgical management were excluded. For each publication, clinical success based on the control of the bleed, rebleeding rates and complications (including mortality) was collected, as well as technical details. Results: Sixty-three studies met the inclusion criteria, with an aggregate total of 267 patients. Follow-up extended from 1 day to 10 years. Bleeding was mainly localized to the iliopsoas (n = 113/267, 42.3%) and anterior abdominal wall (n = 145/266, 54.7%). When information was available, 81.0% (n = 158/195) of patients were on anticoagulant therapy prior to the bleeding episode. Initial stabilization with control of the bleed was obtained in 93.1% (n = 242 patients, n = 60 studies). The most common embolic materials were coils (n = 129, 54.4%). Rebleeding was reported in 25 patients (9.4%). Only two embolization complications were reported (0.7%). The 30-day mortality was 22.7% (n = 42/1857). Conclusion: TAE represents a safe and effective procedure in the management of SSTH. We present a management algorithm based on these data, but further studies are needed to address the knowledge gap.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Enlarged Fibroid Uterus: Aberrant Arterial Supply via the Omental Artery

Uterine artery embolization is considered a first-line therapy for symptomatic fibroids and is occasionally required to mitigate operative risk prior to total abdominal hysterectomy or myomectomy. We present a pictorial review of parasitized omental artery supply to the enlarged fibroid uterus in three patients undergoing preoperative uterine artery embolization. A detailed understanding of variant uterine blood supplies is crucial when performing fibroid embolization. Although omental artery supply to the fibroid uterus is an unusual finding, aortography to include mesenteric arteries may be necessary when anomalous blood supply to the enlarged fibroid uterus is suspected.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiofrequency Ablation of the Marginal Venous System in Patients with Venous Malformations

Purpose: To evaluate radiofrequency ablation (RFA) for closure of marginal veins in pediatric and adult patients with venous malformations. Materials and methods: Medical records, imaging and procedure details were retrospectively reviewed in patients who underwent RFA of the marginal vein in a 17-month period. Additional sclerotherapy (n = 19) and coil embolization of the marginal vein were performed (n = 2). Results: A total of 23 marginal veins were treated in 20 patients. Mean age at treatment was 16 years ± 9.4 (1–37 years). Pre-procedural magnetic resonance imaging revealed thoracoabdominal marginal veins in 3 patients. A type I marginal vein (draining in the great saphenous vein below the popliteal vein) was identified in 1 and type IIa/IIb (draining in a median/lateral accessory saphenous vein) in 2/8 cases. Type III (draining into the profunda femoral vein) was detected in 8, and type IV (draining into gluteal veins) in 1. Mean diameter of the marginal veins was 13.2 mm ± 4 (7–20 mm). Patency was found in 1 during follow-up (22 months ± 9.8). Complete or partial occlusion was achieved in 94.5% of the veins. One patient showed signs of thrombophlebitis after the procedure, and another incomplete paresis of the peroneal nerve. Conclusion: RFA is effective as minimally invasive treatment of the marginal venous system. These veins should be treated early in life. Marginal veins with large diameter, residual tributaries and the intrafascial courses usually require adjunct coil embolization and sclerotherapy. Level of Evidence: Case series, Level IV.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prospective Study on Total Fluoroscopic Time in Patients Undergoing Uterine Artery Embolization: Comparing Transradial and Transfemoral Approaches

Purpose: Comparing total fluoroscopy time (FT) to perform uterine artery embolization (UAE) with transradial approach (TRA) versus transfemoral approach (TFA). Our hypothesis was that there would be no significant procedural time penalty incurred, despite the learning curve associated with adopting a new approach. Materials and Methods: A cohort study was undertaken including 66 consecutive patients undergoing UAE with either TRA/TFA between January and September 2015. Total FT was recorded prospectively for each procedure, and data subsequently analyzed retrospectively. Each operator had at least 2 years of experience as an interventional radiologist having performed at least 200 TFA UAEs. All operators had recently incorporated TRA into their practice. Results: A total of 39 TFA and 27 TRA cases were included in the study; mean age for TFA group was 44.4 years (± 4.9) and for TRA group was 45.1 years (± 4.9) (p = 0.59). Mean FTs were comparable between the two groups (p = 0.86) despite a learning curve associated with TRA: The mean total FT with TFA was 20.36 min (± 9.48) compared to TRA 20.12 min (± 7.67). Conclusions: FTs for TRA UAE were comparable to TFA UAE, even though TRA had been recently adopted as a new approach. Despite the learning curve associated with developing a novel technique, operators should not expect the efficiency of their service to be significantly compromised. Introducing this safe and effective method of vascular access should therefore be considered.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Visibility of Hypovascularized Liver Tumors during Intra-Arterial Therapy Using Split-Bolus Single-Phase Cone Beam CT

Purpose: To validate a split-bolus contrast injection protocol for single-phase CBCT in terms of detectability of hypovascular liver tumors compared to digital subtraction angiography (DSA). Materials and Methods: In this retrospective, single-center study, 20 consecutive patients with in total 77 hypovascularized tumors referred for intra-arterial therapy received a split-bolus single-phase CBCT. Two readers rated the visibility of the target tumors scheduled for embolization in CBCT and DSA compared to the pre-interventional multiphasic CT or MRI used as reference on a 3-point scoring system (1 = optimal, 3 = not visible) and catheter-associated artifacts (1 = none, 3 = extended). SNR, CNR and contrast values were derived from 37 target tumors in CBCT and MRI. Statistical analysis included the kappa test to determine interrater reliability, the Friedman’s test for the inter-modality comparison evaluating tumor visibility in DSA and CBCT as well as for quantitative assessment. Post hoc analysis included the Wilcoxon signed-rank test. p values < 0.05 were considered significant. Results: Ninety percentage of target tumors were rated as visible in CBCT and 37.5% in DSA (p < 0.001). 70.1% of pre-interventionally detected hypovascularized tumors were depicted with CBCT and 31.2% by DSA (p < 0.001). 7.8% of known tumors were outside the FOV. Quantitative assessment showed higher image contrasts in CBCT (1.91 ± 7.01) compared to hepatobiliary-phase MRI (0.29 ± 0.14, p = 0.003) and to portal-venous (p.v.) MRI (0.31 ± 0.13, p < 0.001), but higher CNR for MRI (1.18 ± 0.80; 13.92 ± 15.82; 13.79 ± 6.65). Conclusion: In conclusion, the split-bolus single-phase CBCT detects significantly more hypovascularized liver tumors compared to DSA performed through the proper hepatic artery with high image contrasts. Level of Evidence: Level III, diagnostic study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗