Search NASA⌕ Search

SEARCH · Search NASA

Results for “Vibration Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Characterization of the liquid sodium spray generated by a pipework hole

Due to its advantageous thermodynamic characteristics at high temperature (550 deg. C), liquid sodium is the main candidate to be the cooling fluid for Generation TV nuclear reactors SFR (Sodium-cooled Fast Reactors). Now, sodium reacts very violently, both with the water and the oxygen of the air. Only few data were known about the liquid sodium behaviour when spread in the environment through micro defects. These are often present in a cooling circuit in welded or sealed joints and more rarely in the pipes. Micro defects, on the other hand, can be also generated in a cooling circuit because of the vibrations always present in a circuit into which a fluid runs. A new set-up, named LISOF, was built for testing high temperature liquid sodium when passing through micro defects and generating sprays or jets. Sprays and jets were generated by means of nozzles embedding sub milli-metric holes the diameter of which was: 0.2 mm, 0.4 mm, 0.5 mm. Tests were performed by pressurizing liquid sodium (550 deg. C) at: 3, 6 and 9 barg. Normal and high speed cinematography were used for the direct observation of the liquid sodium sprays while Phase Doppler Interferometry was used for the measurement of the droplets characteristics and velocity. Tests concerning the behaviour of the high temperature liquid sodium firing in air or in contact with the cement cover applied to a scaled down core catcher simulacrum were also performed. The paper presents the built set-up and the collected results. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Testing of Helium-Cooled Metal Molybdenum Disk Target

NorthStar Medical Radioisotopes LLC is planning to produce an important medical radioisotope, molybdenum-99 (Mo-99), through photonuclear reaction on molybdenum-100 (Mo-100). In this approach, molybdenum metal will be bombarded with a 40-MeV electron beam. Because enriched Mo-100 is expensive, it is desired to use as much beam power as possible to achieve maximum production yield and minimize target mass. This objective leads to very high beam power density (heat deposition in the target), which sets challenging requirements for cooling. Together with scientists at Los Alamos National Laboratory, a team at Argonne National Laboratory has developed and demonstrated a cooling approach using pressurized helium, which allows for efficient heat removal. One of the main challenges in this approach is the management of the heat load on the target window. The target window separates the high-pressure helium inside the target from the vacuum in the beamline, so it is constantly under stress from differential pressure. Also, the window is cooled only by the helium gas flowing on one side, making the window cooling even more challenging. High heat deposition in the target disks also imposes a strict requirement on performance of the helium cooling system and thickness of the target disks. The target disks are produced from metal powder via a press-and-sinter process. The resulting disks do not possess tensile strength as high as solid molybdenum and might not survive the vibration from the high-velocity helium coolant and high thermal stress from beam heating. An Argonne team of scientists performed a series of tests at Argonne’s Low Energy Accelerator Facility (LEAF) [3-7]. This report describes two series of tests for scale down production target designs that utilize full-scale 29 millimeters diameter, 0.75 mm thick press-and-sintered disks. We performed two thermal tests with different beam parameters and configurations of the disk laminations. We compared the results of the window temperature measurements and cooling system parameters obtained in the experiments with those predicted by analytical calculations and Computation Flow Dynamic (CFD) simulations. Results of the experiments and calculations are presented below.

36 MATERIALS SCIENCE↗

Measurement of rabbit eardrum vibration through stroboscopic digital holography

In this work, we present a setup for high-power single shot stroboscopic digital holography and demonstrate it in an application on rabbit eardrum vibration measurement. The setup is able to make full-field time-resolved measurements of vibrating surfaces with a precision in the nanometer range in a broad frequency range. The height displacement of the measured object is visualized over the entire surface as a function of time. Vibration magnitude and phase maps can be extracted from these data, the latter proving to be very useful to reveal phase delays across the surface. Such deviations from modal motion indicate energy losses due to internal damping, in contrast to purely elastic mechanics. This is of great interest in middle ear mechanics and finite element modelling. In our setup, short laser pulses are fired at selected instants within the surface vibration period and are recorded by a CCD camera. The timing of the pulses and the exposure of the camera are synchronized to the vibration phase by a microprocessor. The high-power frequency-doubled Nd:YAG laser produces pulses containing up to 5 mJ of energy, which is amply sufficient to record single-shot holograms. As the laser pulse length is 8 ns and the smallest time step of the trigger electronics is 1 μs, vibration measurements of frequencies up to 250 kHz are achievable through this method, provided that the maximum vibration amplitude exceeds a few nanometers. In our application, middle ear mechanics, measuring frequencies extend from 5 Hz to 20 kHz. The experimental setup will be presented, as well as results of measurements on a stretched circular rubber membrane and a rabbit's eardrum. Two of the challenges when measuring biological tissues, such as the eardrum, are low reflectivity and fast dehydration. To increase reflectivity, a coating is applied and to counteract the undesirable effects of tissue dehydration, the measurement setup and software have been optimized for speed without compromising on the quality. Results of a repeatability test will be presented as well. Since the method measures the membrane motion as a function of time in small time steps, we do not only measure vibration amplitude like in time-average holography, but we can also measure non-linear elastic and transient behaviour. In conclusion, the combination of good spatial, depth and time resolution with the fast data acquisition and very wide frequency range make our technique applicable in a number of fields, including biological tissue vibrations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Heterogeneous System for Eagle Detection, Deterrent, and Wildlife Collision Detection for Wind Turbines (Final Technical Report)

This report summarizes the design, implementation, and test of an integrated system for automated detection and deterrence of eagles, with included wind turbine blade strike detection and imaging functionality. A machine learning approach was used in conjunction with a 360° camera system for automated detection and classification of golden eagles. This was developed using footage obtained from trained golden eagles and other raptors, in collaboration with wildlife biologists and professional bird handlers. Oregon State University developed a visual deterrent system, which uses inflatable anthropomorphic sculptures with random, kinetic motion to deter eagles, and conducted limited field testing on live eagles; the deterrent can be triggered by the visual detection of eagles using the vision system. Finally, a multi-sensor module was developed that is mounted at the turbine blade root. This module measures vibration and other motions to detect blade strikes, and an integrated on-blade camera captures an image of any impacting objects. Long-term, this blade strike detection system is intended to support an automatic monitoring and certification system for the eagle detection and deterent system. Independent field testing of each system component is described. Testing of the integrated system on an operational wind turbine was conducted across three separate field tests. This includes multi-day fields tests on a General Electric 1.5MW wind turbine at the National Renewable Energy Laboratory (NREL) National Wind Technology Center (NWTC) in Boulder, CO in October 2018 and July 2019; installation procedures, test procedures, and a summary of collected data are presented. A third multi-day on-turbine field test is also presented, which was performed using a General Electric 1.5MW wind turbine at the North American Wind Research and Training Center (NAWRTC) at Mesalands Community College, Tucumcari, NM in April 2019. Across these field tests, the vision system was demonstrated using unmanned aerial vehicles (UAV), and the eagle classification algorithm was not tested; the visual deterrent system was demonstrated, including automatic, remote deployment following surrogate visual detections; and, multi-sensor on-blade data was recorded across multiple wind turbine operational conditions and through more than 100 surrogate blade strikes using soft projectiles, including the successful demonstration of automatic image capture of striking objects. This data set was also used for offline development and validation of enhanced collision detection algorithms. As summarized in this report, the development and field validation of an integrated detection, deterrent, and blade collision detection system represents a critical proof of concept for future technology development of related detection and deterrent technologies, where both deterrent as well as collision detection recording devices are needed for future siting, monitoring, and operation of wind turbine installations, both onshore and offshore.

17 WIND ENERGY↗

Experimental characterization of cantilever-type piezoelectric generator operating at resonance for vibration energy harvesting

A cantilever-type resonant piezoelectric generator (RPG) has been designed by gluing a PZT patch working in d{sub 31} mode onto a glass fibre reinforced composite cantilever beam with a discrete mass applied on its free end. The electrical and dynamic behaviour of the RPG prototype has been investigated by carrying out laboratory tests aimed to assess the effect of definite design parameters, specifically the electric resistance load and the excitation frequency. Results showed that an optimum resistance load exists, at which power generation is maximized. Moreover, it has been showed that power generation is strongly influenced by the vibration frequency highlighting that, at resonance, output power can be increased by more than one order of magnitude. Possible applications include inertial resonant harvester for energy recovery from vibrating machines, sea waves or wind flux and self-powering of wireless sensor nodes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Separating and Stabilizing Phosphate from High-Level Radioactive Waste: Process Development and Spectroscopic Monitoring

Removing phosphate from alkaline high-level waste sludges at the Department of Energy's Hanford Site in Washington State is necessary to increase the waste loading in the borosilicate glass waste form that will be used to immobilize the highly radioactive fraction of these wastes. We are developing a process which first leaches phosphate from the high-level waste solids with aqueous sodium hydroxide, and then isolates the phosphate by precipitation with calcium oxide. Tests with actual tank waste confirmed that this process is an effective method of phosphate removal from the sludge and offers an additional option for managing the phosphorus in the Hanford tank waste solids. The presence of vibrationally active species, such as nitrate and phosphate ions, in the tank waste processing streams makes the phosphate removal process an ideal candidate for monitoring by Raman or infrared spectroscopic means. As a proof-of-principle demonstration, Raman and Fourier transform infrared (FTIR) spectra were acquired for all phases during a test of the process with actual tank waste. Quantitative determination of phosphate, nitrate, and sulfate in the liquid phases was achieved by Raman spectroscopy, demonstrating the applicability of Raman spectroscopy for the monitoring of these species in the tank waste process streams.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An intense, few-cycle source in the long-wave infrared

For the last several decades, the wavelength range accessible for strong-field, few-cycle studies has remained limited to the visible, near infrared and mid-wave infrared regimes. In particular, sources in the long-wave infrared have been lacking. We report the development of a 1 kHz, few-cycle laser source with up to a 9 μm central wavelength and gigawatt peak powers. When focused, this source can ionize gas targets, which we demonstrate here through the ionization of atomic xenon at wavelengths ranging from 5 μm to 9 μm. This opens up new opportunities for fundamental atomic and molecular physics, enabling experimental tests of strong-field ionization theories in the extreme long-wavelength, few-cycle limit and the direct excitation of vibrational transitions in organic molecules.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Lattice constants and optical response of pseudomorph Si-rich SiGe:B

Pseudomorph epitaxial films of Si{sub 1−x}Ge{sub x}:B were grown on undoped (100) Si for x ≤ 0.026 and the B concentration of 1.3 × 10{sup 20} cm{sup −3}.The in-plane and out-of-plane lattice constants were determined using the X-ray techniques for 004 symmetric and 224 asymmetric diffraction. The influence of B and Ge co-doping has been detected in reflectance and ellipsometric spectra from infrared to ultraviolet. Free-hole plasma and Fano-type resonances of Si phonons and localized {sup 11}B and {sup 10}B vibrations have been observed. The spectral shift of E{sub 1} electronic transitions has been quantified. We found a simple way to test the variations of Ge content using relative reflectance spectra.

36 MATERIALS SCIENCE↗

Measurement of local internal friction in metallic glasses

Atomic force acoustic microscopy (AFAM), an advanced scanning probe microscopy technique, has been used to measure local elastic properties with a spatial resolution given by the tip-sample contact radius. AFAM is based on inducing out-of-plane vibrations in the specimen. The vibrations are sensed by the AFM cantilever from by the photodiode signal when its tip is in contact with the material under test. To measure local damping, the inverse quality factor Q{sup −1} of the resonance curve is usually evaluated. Here, from the contact-resonance spectra obtained, we determine the real and imaginary part of the contact stiffness k* and from these two quantities the local damping factor Q{sub loc}{sup −1} is obtained which is proportional to the imaginary part γ of the contact stiffness. The evaluation of the data is based on the cantilever's mass distribution with damped flexural modes and not on an effective point-mass approximation for the cantilever’s motion. The given equation is simple to use and has been employed to study the local Q{sub loc}{sup −1} of amorphous PdCuSi metallic glass and its crystalline counterpart as a function of position of the AFM tip on the surface. The width of the distribution changes dramatically from the amorphous to the crystalline state as expected from the consequences of the potential-energy landscape picture. The center value of the distribution curve for Q{sub loc}{sup −1} coincides very well with published data, based on global ultrasonic or internal friction measurements. This is compared to Q{sub loc}{sup −1} measured in crystalline SrTiO{sub 3}, which exhibits a narrow distribution, as expected.

36 MATERIALS SCIENCE↗

Thermal conductance of interfaces between titanium nitride and group IV semiconductors at high temperatures

Measuring the temperature dependence of material properties is a standard method for better understanding the microscopic origins for that property. Surprisingly, only a few experimental studies of thermal boundary conductance at high temperatures exist. This lack of high temperature data makes it difficult to evaluate competing theories for how inelastic processes contribute to thermal conductance. To address this, we report time domain thermoreflectance measurements of the thermal boundary conductance for TiN on diamond, silicon-carbide, silicon, and germanium between 120 and 1000 K. In all systems, the interface conductance increases monotonically without stagnating at higher temperatures. For TiN/SiC interfaces, G ranges from 330 to 1000 MW/m2-K, with a room temperature conductance of 750 MW/m2-K. The interface conductance for TiN/diamond ranges from 140 to 950 MW/m2-K. Notably, for all four interfacial systems, the conductance continues to increase with temperature even after all phonon modes in the vibrationally soft material are thermally excited. This observation suggests that inelastic processes are significant contributors to the thermal conductance in all four interfacial systems, regardless of whether the materials forming the interface are vibrationally similar or dissimilar. Our study fills a notable gap in the literature for how interfacial conductance evolves at high temperatures and tests burgeoning theories for the role of inelastic processes in interfacial thermal transport.

Physics↗

Active beam position stabilization of pulsed lasers for long-distance ion profile diagnostics at the Spallation Neutron Source (SNS)

A high peak-power Q-switched laser has been used to monitor the ion beam profiles in the superconducting linac at the Spallation Neutron Source (SNS). The laser beam suffers from position drift due to movement, vibration, or thermal effects on the optical components in the 250-meter long laser beam transport line. We have designed, bench-tested, and implemented a beam position stabilization system by using an Ethernet CMOS camera, computer image processing and analysis, and a piezo-driven mirror platform. The system can respond at frequencies up to 30 Hz with a high position detection accuracy. With the beam stabilization system, we have achieved a laser beam pointing stability within a range of 2 rad (horizontal) to 4 rad (vertical), corresponding to beam drifts of only 0.5 mm 1 mm at the furthest measurement station located 250 meters away from the light source.

43 PARTICLE ACCELERATORS↗

Properties of Noise Cross-Correlation Functions Obtained from a Distributed Acoustic Sensing Array at Garner Valley, California

A field test that was conducted at Garner Valley, California, on 11 and 12 September 2013 using distributed acoustic sensing (DAS) to sense ground vibrations provided a continuous overnight record of ambient noise. Furthermore, the energy of ambient noise was concentrated between 5 and 25 Hz, which falls into the typical traffic noise frequency band. A standard procedure (Bensen et al., 2007) was adopted to calculate noise cross-correlation functions (NCFs) for 1-min intervals. The 1-min-long NCFs were stacked using the time–frequency domain phase-weighted-stacking method, which significantly improves signal quality. The obtained NCFs were asymmetrical, which was a result of the nonuniform distributed noise sources. A precursor appeared on NCFs along one segment, which was traced to a strong localized noise source or a scatterer at a nearby road intersection. NCF for the radial component of two surface accelerometers along a DAS profile gave similar results to those from DAS channels. Here, we calculated the phase velocity dispersion from DAS NCFs using the multichannel analysis of surface waves technique, and the result agrees with active-source results. We then conclude that ambient noise sources and the high spatial sampling of DAS can provide the same subsurface information as traditional active-source methods.

58 GEOSCIENCES↗

Scalable Enrichment of 48 Ca at the Solid/liquid Interface by Chemical and Electrochemical Methods

This award targets to develop methods to enrich 48 Ca, which is a critical isotope for synthesizing superheavy elements and testing the standard model through neutrinoless double beta decay. The team first tested chemical exchange-based separation between solids and liquids, which is based on the free energy change due to the different vibrational frequencies caused by Ca isotopes in a material. However, the separation factor (alpha), which is defined as the ratio of 40 Ca/ 48 Ca ratios in the two phases, only reach ~1.01. The team then developed liquid centrifugation-based isotope separation, where a Ca salt aqueous solution is centrifuged at a speed of ~60 kRPM, and 48 Ca is enriched at the bottom of a centrifuge tube due to its larger mass. A high α of ~1.2-1.4 is achieved for 40 Ca/ 48 Ca at 40 °C. This method is further approved to be generic for any isotope that can be dissolved in a liquid solution or form liquid chemicals near room temperature. The experimental results also align well with modeling prediction. The team further develop a model to evaluate isotope separation in countercurrent liquid centrifugation. The team found that the countercurrent configuration can also enhance isotope separation in liquids, similar with gas centrifugation, which boost separation for isotopes which are difficult to be gasified near room temperature.

07 ISOTOPE AND RADIATION SOURCES↗

On the flow induced vibration of an externally excited nuclear reactor experiment

An in-pile, drop-in experiment design is presently being designed and studied for the near-term deployment within the Advanced Test Reactor (ATR) located at the Idaho National Laboratory (INL); this experiment is termed the Miniplate-1 Large-B (MP-1 LB) Experiment. A number of explicit studies are performed during the design- and safety-related stage. Traditionally, a clear and logical methodology has been developed and utilized for analyses such as hydraulics, thermal-loads, mechanical loads, and others for these experiments. Recently a small component from a different experiment assembly mechanically separated while in the reactor’s core. While this experiment didn’t compromise the safety of the reactor, it led to a higher-level question which centered on whether the appropriate level of consideration was being made toward the fluid–structure-interactions of these experiments. The outcome yielded separate flow test experiments of like-for-like geometry in an experimental loop located at Oregon State University which produces experimental data compliant with applicable parts and requirements to ASME’s NQA-1 2008, 2009a standard – suitable for benchmark evaluation. Here, the objectives of this study are to (1) develop a process for handling and interpreting the mechanical response of the test elements during hydraulic testing, to (2) characterize the motion of a specific test element during a flow test which imposes a wide range of hydraulic conditions, and (3) provide objective observations toward the potential safety related implications that are tied to the synthesized data. The outcome of this study has led to a confident process in inspecting the experimental data, synthesized it for interpretation, identified several unique hydraulic characteristics of the experiment design which were previously unknown, and demonstrated that the likelihood for mechanical failure resulting from fluid-structure-interactions in the reactor is far below any criterion for concern of the element’s safety.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Using Finite Model Analysis and Out of Hot Cell Surrogate Rod Testing to Analyze High Burnup Used Nuclear Fuel Mechanical Properties

Based on a series of FEA simulations, the discussions and the conclusions concerning the impact of the interface bonding efficiency to SNF vibration integrity are provided in this report; this includes the moment carrying capacity distribution between pellets and clad, and the impact of cohesion bonding on the flexural rigidity of the surrogate rod system. As progressive de-bonding occurs at the pellet-pellet interfaces and at the pellet-clad interface, the load ratio of the bending moment carrying capacity gradually shifts from the pellets to the clad; the clad starts to carry a significant portion of the bending moment resistance until reaching the full de-bonding state at the pellet-pellet interface regions. This results in localized plastic deformation of the clad at the pellet-pellet-clad interface region; the associated plastic deformations of SS clad leads to a significant degradation in the stiffness of the surrogate rod. For instance, the flexural rigidity was reduced by 39% from the perfect bond state to the de-bonded state at the pellet-pellet interfaces.

fuel-pellet interface↗

Kirigami Photopiezo Catalysts for Self-Sustainable Environment Remediation

Photo(electro)-piezo catalysis has emerged as one of the most effective strategies for sustainable environmental remediation. While various (nano)materials have been investigated for enhancing the intrinsic properties related to the interfacial band structure, increasing the efficiency by integration of materials with rational design for stress–strain applications has not yet been considered. Herein, we introduce kirigami strain engineering to photopiezo catalysts for enhancing efficiency by increasing the magnitude of applied strain and density of bends. Macroscale stretching motion is converted into localized bending by a pliable kirigami structure using similar or even lower input energy, which can be easily modulated by natural waves. The kirigami structure leads to a significant enhancement (~250%) in the degradation of dyes, and we discovered the significant contribution of the oxygen reduction pathway in the charge-transfer mechanism, which corresponds to the observed enhancement. In conclusion, the photopiezo catalytic effects of kirigami were further highlighted by the small water reservoir test, showing its feasibility in nature for self-sustainable environmental remediation that can be modulated using motions of winds, waves, and life vibrations.

14 SOLAR ENERGY↗

Optical emission spectroscopic diagnostics of a non-thermal atmospheric pressure helium-oxygen plasma jet for biomedical applications

In this work, we have applied optical emission spectroscopy diagnostics to investigate the characteristics of a non-thermal atmospheric pressure helium plasma jet. The discharge characteristics in the active and afterglow region of the plasma jet, that are critical for biomedical applications, have been investigated. The voltage-current characteristics of the plasma discharge were analyzed and the average plasma power was measured to be around 18 W. The effect of addition of small fractions of oxygen at 0.1%-0.5% on the plasma jet characteristics was studied. The addition of oxygen resulted in a decrease in plasma plume length due to the electronegativity property of oxygen. Atomic and molecular lines of selected reactive plasma species that are considered to be useful to induce biochemical reactions such as OH transitions A{sup 2}{Sigma}{sup +}({nu}=0,1){yields}X{sup 2}{Pi}({Delta}{nu}=0) at 308 nm and A{sup 2}{Sigma}{sup +}({nu}=0,1){yields}X{sup 2}{Pi}({Delta}{nu}=1) at 287 nm, O I transitions 3p{sup 5}P{yields}3s{sup 5}S{sup 0} at 777.41 nm, and 3p{sup 3}P{yields}3s{sup 3}S{sup 0} at 844.6 nm, N{sub 2}(C-B) second positive system with electronic transition C{sup 3}{Pi}{sub u}{sup {yields}}B{sup 3}{Pi}{sub g}'' in the range of 300-450 nm and N{sub 2}{sup +}(B-X) first negative system with electronic transition B{sup 2}{Sigma}{sub u}{sup +}{yields}X{sup 2}{Sigma}{sub g}{sup +}({Delta}{nu}=0) at 391.4 nm have been studied. The atomic emission lines of helium were identified, including the He I transitions 3p{sup 3}P{sup 0}{yields}2s{sup 3}S at 388.8 nm, 3p{sup 1}P{sup 0}{yields} 2s{sup 1}S at 501.6 nm, 3d{sup 3}D{yields}2p{sup 3}P{sup 0} at 587.6 nm, 3d{sup 1}D{yields}2p{sup 1}P{sup 0} at 667.8 nm, 3s{sup 3}S{sup 1}{yields}2p{sup 3}P{sup 0} at 706.5 nm, 3s{sup 1}S{sup 0}{yields}2p{sup 1}P{sup 0} at 728.1 nm, and H{sub {alpha}} transition 2p-3d at 656.3 nm. Using a spectral fitting method, the OH radicals at 306-312 nm, the rotational and vibrational temperatures equivalent to gas temperatures of the discharge was measured and the effective non-equilibrium nature of the plasma jet was demonstrated. Our results show that, in the entire active plasma region, the gas temperature remains at 310 {+-} 25 K and 340 {+-} 25 K and it increases to 320 {+-} 25 K and 360 {+-} 25 K in the afterglow region of the plasma jet for pure helium and helium/oxygen (0.1%) mixture, respectively. Additionally, the vibrational temperatures range from 2200 {+-} 100 K and 2500 {+-} 100 K for pure helium and helium/oxygen (0.1%) mixture, respectively. The plasma jet was tested on heat sensitive polymer films used in biomedical applications such as polyethylene terephthalate and poly-L-lactide samples continuously for several minutes without causing any physical or thermal damage to the films. The plasma jet produces significant reactive species of interest while the gas temperatures remain very low demonstrating its potential for a range of biomedical applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Retro-Commissioning Sensor Suitcase for Energy Efficiency

This project will enable Pacific Northwest National Laboratory (PNNL) and Lawrence Berkeley National Laboratory (LBNL) to work with industry partner, GreenPath Energy Solutions, joint developers of the Suitcase, to enhance the capabilities and usability of the Retro-Commissioning Sensor Suitcase (hereinafter the Sensor Suitcase or Suitcase), assisting GreenPath to take the Suitcase to market and rapidly expand their market share. The proposed project will specifically focus on 1) adding sensors types to extend the data collection capability and support more building and equipment performance metrics and identification of even more energy saving opportunities, 2) developing algorithms to identify recommendations for the new energy savings opportunities from item 1 and to prototype software modifications implementing them, 3) validating the use of vibration sensors to detect the operating state of a broader set of packaged HVAC equipment (additional capacities, different numbers of stages, etc.) than tested in initial development and modifying the state algorithm and software code, as needed, 4) improving cost-effectiveness in manufacturing the Sensor Suitcase, and 5) additional field testing of the technology in real buildings to more comprehensively validate Suitcase performance and to guide refinement of its capabilities. Project results will position GreenPath, and potential future licensees, to implement the new capabilities developed in this project in GreenPath’s RCx Building Suitcase, increasing its functionality and the savings resulting from its use. These enhancements will increase the value of the Suitcase to users and increase the potential market for its use and impacts in that impact.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗