Search NASA⌕ Search

SEARCH · Search NASA

Results for “Volatile analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Editorial to the special issue on the 2015 TOUGH Symposium

This Special Issue of Transport in Porous Media features selected papers from the 2015 TOUGH Symposium, which took place on September 28–30, 2015, in Berkeley, California, USA. Such symposia are held every 3 years and are a forum where users of the TOUGH family of numerical simulators meet for an open exchange on the code applications and recent enhancements. The TOUGH codes (TOUGH is an acronym for Transport of Unsaturated Groundwater and Heat) were originally developed in the early 1980s for geothermal reservoir simulation by a team of researchers at the Lawrence Berkeley National Laboratory (LBNL) headed by Karsten Pruess (see http://esd.lbl.gov/TOUGH). The TOUGH codes have a modular structure in which different fluid components can be incorporated into the code by means of a replaceable equation of state (EOS) package. Since its first release, a variety of important EOS modules have been developed, enabling the modeling of volatile organic compounds, decay chains of multiple radionuclides, gas hydrates, tight and shale gas behavior, enhanced oil recovery, and supercritical water and CO 2 . Derivatives and descendants of the basic TOUGH code include coupled multi-phase flow and reactive chemical transport; coupled thermo-hydrologic-mechanical processes; inverse modeling for parameter estimation, sensitivity analysis, and uncertainty quantification; and parallelization for multi-core PCs, workstation clusters, and supercomputers. The TOUGH codes have been applied to a large variety of problems, including geothermal and petroleum reservoir engineering, nuclear waste and CO 2 geologic sequestration, subsurface environmental remediation, methane gas hydrate production, compressed air energy storage, and many other energy and environmental applications. Finally, the international TOUGH user community currently numbers almost 400 organizations (research laboratories, government agencies, private companies, universities, etc.) in over 60 countries.

99 GENERAL AND MISCELLANEOUS↗

Surface Chemistry and Particle Morphology Changes in Pine Biomass under Indirect Thermal Gradients: Implications for Feed Screw Design

The conversion of biomass feedstocks into fuels and chemicals using fast pyrolysis is a promising approach to renewable energy. Feed screws that convey biomass to pyrolysis reactors, however, often encounter plugging. Indirect heating of the feed screw occurs due to contact with the pyrolysis chamber, resulting in a heating gradient ranging from ambient temperature (22 °C) to reactor temperature (500 °C). Given that major cell wall macromolecules, such as lignin, cellulose, and hemicellulose, begin to produce bio-oils and volatile resin acid compounds within this temperature gradient, we hypothesized that indirect heating during feed screw conveyance is sufficient to cause premature degradation of biomass. We characterized this degradation by observing increases in surface roughness, changes in overall particle morphology, and the production and deposition of bio-oils on biomass particle surfaces. Correlative analysis between optical in situ hot-stage microscopy, confocal Raman spectroscopy, and SEM analysis revealed that heating at temperatures as low as 375 °C caused significant increases in surface roughness, with large fissures forming between and within cell walls. Additionally, droplets of bio-oil were observed on particles, especially in the bark and cambium samples. This work suggests that these phenomena contribute to particle agglomeration, leading to feed screw plugging, and that engineering a solution to cool the feed screw could prevent particle agglomeration and reduce plugging incidents, thereby increasing biomass processing efficiency.

09 BIOMASS FUELS↗

Proton Nuclear Magnetic Resonance (H NMR) of Glycolate in Real Waste: Developing and Testing Analytical Methods for the Savannah River Site Liquid Waste System

In preparation for implementing the NG acid flowsheet for the SRS LWS, analytical methods for determining glycolate at low concentration are desired to support system management and safety. Previous work documented that the IC method performed well for samples with low to moderate ionic strength. That work also included a scoping effort to determine if an alternate analytical strategy using H NMR would complement and extend the capabilities of the IC method. The H NMR scoping results indicated that the method had the potential to expand glycolate analysis in LWS samples to higher ionic strength tanks/solutions. The scope of this work is to develop innovative proton NMR techniques, including demonstrating ion exchange decontamination protocols needed for application of the technique to real waste samples. Part of radioactive waste processing at SRS uses formic acid to reduce oxidized (Hg 2+ ) to more volatile elemental Hg for steam striping, collecting, and disposal. Under acidic conditions found in the Chemical Processing Cell (CPC) at the Defense Waste Processing Facility (DWPF), formic acid has a much higher hydrogen generation rate than an alternative reductant, glycolic acid. Thus, an NG acid flowsheet has been developed utilizing glycolic acid with the benefit of easing the need for headspace monitoring requirements for hydrogen and ammonia at DWPF. Low concentrations of glycolate are conservatively assumed to be in the recycle stream, which will collect in the Recycle Collection Tank (RCT). The DWPF recycle stream collected in the RCT has a distinct pathway to the LWS waste tanks that feed the 2H and 3H Evaporator. This route involves transfer of the DWPF recycle to Tank 22 in the Concentration, Storage, and Transfer Facilities (CSTF) followed by transfer to the LWS tank farm/evaporators.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fine Aerosol Acidity and Water during Summer in the Eastern North Atlantic

Aerosol pH governs many important atmospheric processes that occur in the marine boundary layer, including regulating halogen and sulfur chemistries, and nutrient fertilization of surface ocean waters. In this study, we investigated the acidity of PM1 over the eastern North Atlantic during the Aerosol and Cloud Experiments in Eastern North Atlantic (ACE-ENA) aircraft campaign. The ISORROPIA-II thermodynamic model was used to predict PM1 pH and water. We first investigated the sensitivities of PM1 pH and water predictions to gas-phase NH3 and HNO3 concentrations. Our sensitivity analysis indicated that even though NH3 and HNO3 were present at very low concentrations in the eastern North Atlantic during the campaign, PM1 pH calculations can still be sensitive to NH3 concentrations. Specifically, NH3 was needed to constrain the pH of populations of PM1 that had low mass concentrations of NH4+ and non-volatile cations (NVCs). We next assumed that gas-phase NH3 and HNO3 concentrations during the campaign were 0.15 and 0.09 µg m−3, respectively, based on previous measurements conducted in the eastern North Atlantic. Using the assumption that PM1 were internally mixed (i.e., bulk PM1), we determined that PM1 pH ranged from 0.3–8.6, with a mean pH of 5.0 ± 2.3. The pH depended on both Hair+ and Wi. Hair+ was controlled primarily by the NVCs/SO42− molar ratio, while Wi was controlled by the SO42− mass concentration and RH. Changes in pH with altitude were driven primarily by changes in SO42−. Since aerosols in marine atmospheres are rarely internally mixed, the scenario where non-sea salt species and sea-salt species were present in two separate aerosol modes in the PM1 (i.e., completely externally mixed) was also considered. Smaller pH values were predicted for the aerosol mode comprised only of non-sea salt species compared to the bulk PM1 (difference of around 1 unit on average). This was due to the exclusion of sea-salt species (especially hygroscopic alkaline NVCs) in this aerosol mode, which led to increases in Hair+ values and decreases in Wi values. This result demonstrated that assumptions of aerosol mixing states can impact aerosol pH predictions substantially, which will have important implications for evaluating the nature and magnitude of pH-dependent atmospheric processes that occur in the marine boundary layer.

54 ENVIRONMENTAL SCIENCES↗

Technical and economic feasibility of solar flat-plate collector thermal energy systems for small and medium manufacturers

Manufacturing industries require process heating for a wide variety of operations, such as drying, cooking, washing, and sterilizing. Studies of industrial energy consumption have shown that more than 50% of industrial heating demand is in the low (<60 °C), medium (60-150 °C), and medium-high (<250 °C) temperature ranges. A significant fraction of this low temperature thermal energy could be generated by commercially available solar flat-plate collector thermal energy systems, which would reduce the use of fossil fuels, energy cost volatility, and carbon emissions. However, manufacturing industries have not been able to take advantage of solar flat-plate collector systems for two main reasons: First, information is not readily available about when and what flat-plate collector system sizes can be economically applied and, second, manufacturers often do not have appropriate personnel or analysis tools to make decisions about installation of solar flat-plate collector systems. The goal of this research is to provide design decision support to small- and medium-sized manufacturers in conducting feasibility analysis for the application of solar flat-plate collector systems in their operations. The $\bar{φ}, f$-chart method and modified $\bar{φ}, f$-chart design method are used to predict the amount of energy collected by solar flat-plate collectors. A simplified model is proposed to assess the cost of solar flat-plate collector energy systems. To demonstrate the presented feasibility analysis methodology, a decision support software application is developed. What-if scenarios are presented for several geographic locations of varying climates. A sensitivity analysis of savings-to-investment ratio (SIR) was performed by changing selected input parameters by ±30% from the base case. It was found that SIR is sensitive to natural gas price, followed by collector area dependent cost, discount rate, cost of the auxiliary gas heater, and cost of the preheating system.

14 SOLAR ENERGY↗

Technology Enablers for Advanced Gasoline Compression Ignition Engines

To meet current emission regulations and increasingly demanding global fleet CO2 standards on fuel economy and future trends towards life cycle GHG emissions, advanced combustion engines remain significant in the passenger vehicle sector to achieve high efficiency and low emissions over the full operating range. Lean burn gasoline compression ignition (GCI) technology has shown to have the most potential in reaching these goals, although it faces challenges in the operating range. In this study, an advanced GCI engine is considered with the capability to operate under two combustion modes, namely low temperature combustion (LTC) and GCI. They are enabled with the use of two Hyundai in-house developed technologies; an advanced valve control mechanism known as continuously variable valve duration (CVVD) and a high-pressure gasoline injection system. At low load, the engine utilizes dual CVVD and dual CVVT (continuously variable valve timing) mechanisms for both intake and exhaust valvetrains to enable NVO (negative valve overlap) to trap hot residuals. The hot residuals enable low load auto-ignition, and the phasing control of that auto-ignition is achieved by varying the degrees of NVO, and in turn, the amount of hot residuals. This is done in real time with respect to the changes in engine loads or operating conditions, significantly improving cylinder-phasing control in LTC mode, and subsequently is able to realize a fuel economy gain and reduced emission benefits. Early direct injection during NVO or intake stroke is used to form homogenous or quasi-homogenous air-fuel mixture for LTC. At mid to high loads, late direct injection of gasoline or GCI mode is employed to take advantage of the high volatility and high resistance to auto-ignition of gasoline fuel, so that diesel-engine like high combustion efficiency can be achieved with lower soot emissions for the same NOx level as diesel combustion. In this paper, the key control and fueling technologies that enable this multiple mode combustion are introduced, and the resultant analysis on engine test and CFD simulation at LTC and GCI operating conditions are presented in detail.

Gasoline compression ignition, low temperature com↗

Offline solid phase microextraction sampling system

An offline solid phase microextraction (SPME) sampling apparatus for enabling SPME samples to be taken a number of times from a previously collected fluid sample (e.g. sample atmosphere) stored in a fused silica lined bottle which keeps volatile organics in the fluid sample stable for weeks at a time. The offline SPME sampling apparatus has a hollow body surrounding a sampling chamber, with multiple ports through which a portion of a previously collected fluid sample may be (a) released into the sampling chamber, (b) SPME sampled to collect analytes for subsequent GC analysis, and (c) flushed/purged using a fluidically connected vacuum source and purging fluid source to prepare the sampling chamber for additional SPME samplings of the same original fluid sample, such as may have been collected in situ from a headspace.

Harvey, Chris A↗

Solar Thermochemical Fuel Production via a Novel Low Pressure, Magnetically Stabilized, Non-volatile Iron Oxide Looping Process (University of Florida)

The UF Solar Fuels team has developed a modular reactor at the 10kW scale for the thermochemical conversion of H 2 O and CO 2 to H 2 and CO, respectively, using concentrated solar energy to drive high-temperature redox reactions. Various materials, including ferrites, doped and mixed metal ferrites, and ceria, were investigated and reported on. Ceria was chosen as the reactive material, with thermogravimetric and bench-scale analysis concurring with literature review and pointing towards reasonable kinetics and stability at temperatures on the order of 1500°C. A combined radiation, conduction, and species reaction/mass transport model was developed, utilizing Monte Carlo ray tracing, Lattice Boltzmann, and random walk particle tracking for the respective components to direct development and optimization of the reactor. With experimental data used for reaction rates, the model showed a path to efficiencies >20%, which could be market competitive with current PV-hydrolysis hydrogen generation systems. Economic analysis of a larger-scale plant (100kW modular system with cost performed at 500 modules) has been performed, assuming 0.5% and 10% internal rate of return. Without compression costs, H 2 production cost using this is technology at 12 USD/kg H 2 and 17 USD/kg H 2 for realized efficiencies of 20% and 15%, respectively.

14 SOLAR ENERGY↗

Supereruption quartz crystals and the hollow reentrants

Hollow reentrants in quartz phenocrysts from Yellowstone (western United States) caldera’s Lava Creek Tuff are preserved vestiges of bubbles in the supereruption’s pre-eruptive magma reservoir. We characterized the reentrants using a combination of petrographic techniques, synchrotron X-ray microtomography, and cathodoluminescence imagery. One or more reentrants occur in ~20% of quartz, and up to ~90% of those reentrants are hollow. The earliest-erupted parts of the Lava Creek Tuff have the most empty reentrants. The hollow reentrants provide direct, physical evidence for volatile saturation, exsolution, and retention in a magma reservoir. Quartz-melt surface tension permits bubbles to attach to quartz only when bubbles have been able to nucleate and grow in the melt. Prior to eruption, the Lava Creek Tuff existed as a bubbly, volatile-saturated magma reservoir. Finally, the exsolved volatiles increased magma compressibility, helping to prevent the ever-accumulating magma from reaching a critical, eruptive overpressure until it reached a tremendous volume.

58 GEOSCIENCES↗

Healthy Zero Energy Buildings (HZEB) Program - Cross-Sectional Study of Contaminant Levels, Source, Strengths, and Ventilation Rates in Retail Stores

This field study measured ventilation rates and indoor air quality parameters in 21 visits to retail stores in California. The data was collected to guide the development of new, science-based commercial building ventilation rate standards that balance the dual objectives of increasing energy efficiency and maintaining acceptable indoor air quality. Data collection occurred between September 2011 and March 2013. Three types of stores participated in this study: grocery stores, furniture/hardware stores, and apparel stores. Ventilation rates and indoor air contaminant concentrations were measured on a weekday, typically between 9 am and 6 pm. Ventilation rates measured using a tracer gas decay method exceeded the minimum requirement of California’s Title 24 Standard in all but one store. Even though there was adequate ventilation according to Title 24, concentrations of formaldehyde, acetaldehyde, and acrolein exceeded the most stringent chronic health guidelines. Other indoor air contaminants measured included carbon dioxide (CO{sub 2}), carbon monoxide (CO), ozone (O{sub 3}), and particulate matter (PM). Concentrations of CO{sub 2} were kept low by adequate ventilation, and were assumed low also because the sampling occurred on a weekday when retail stores were less busy. CO concentrations were also low. The indoor-outdoor ratios of O{sub 3} showed that the first-order loss rate may vary by store trade types and also by ventilation mode (mechanical versus natural). Analysis of fine and ultrafine PM measurements showed that a substantial portion of the particle mass in grocery stores with cooking-related emissions was in particles less than 0.3 μm. Stores without cooking as an indoor source had PM size distributions that were more similar indoors and outdoors. The whole-building emission rates of volatile organic compounds (VOCs) and PM were estimated from the measured ventilation rates and indoor and outdoor contaminant concentrations. Mass balance models were then used to determine the ventilation rates, filtration strategies, or source reductions needed to maintain indoor contaminant concentrations below reference levels. Several scenarios of potential concern were considered: (i) formaldehyde levels in furniture/hardware stores, (ii) contaminants associated with cooking (e.g., PM, acrolein, and acetaldehyde) in grocery stores, and (iii) outdoor contaminants (e.g., PM and O{sub 3}) impacting stores that use natural ventilation. Estimated formaldehyde emission rates suggest that retail stores would need to ventilate at levels far exceeding the current Title 24 requirement to lower indoor concentrations below California’s stringent formaldehyde reference level. Given the high costs of providing ventilation but only modest chronic health benefit is expected, effective source control is an attractive alternative, as demonstrated by some retail stores in this study. Predictions showed that grocery stores need MERV 13 air filters, instead of MERV 8 filters that are more commonly used, to maintain indoor PM at levels that meet the chronic health standards for PM. Exposure to acrolein is a potential health concern in grocery stores, and should be addressed by increasing the use of kitchen range hoods or improving their contaminant removal efficiency. In stores that rely on natural ventilation, indoor PM can be a health concern if the stores are located in areas with high outdoor PM. This concern may be addressed by switching to mechanical ventilation when the outdoor air quality is poor, while continuing natural ventilation when outdoor air quality is good.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fragmentation of peptide negative molecular ions induced by resonance electron capture

A simple robust method to study resonance gas-phase reactions between neutral peptides of low volatility and free electrons has been designed and implemented. Resonance electron capture (REC) experiments were performed by several neutral model peptides and two naturally occurring peptides. The assignment of negative ions (NIs) formed in these gas-phase reactions was based on high mass-resolving power experiments. From these accurate mass measurements, it was concluded that fragment NIs formed by low (1-2 eV) energy REC are of the same types as those observed in electron capture/transfer dissociation, where the positive charge is a factor. The main feature resulting from these REC experiments by peptides is the occurrence of z{sub n}-1 ions, which are invariably of the highest abundances in the negative ion mass spectra of larger peptides. [M-H]{sup -} NIs presumably the carboxylate anion structure dominate the REC spectra of smaller peptides. There was no evidence for the occurrence of the complementary reaction, i.e., the formations of c{sub n}+1 ions. Instead, c{sub n} ions arose without hydrogen/proton transfer albeit with lower abundances than that observed for z{sub n}-1 ions. Only the amide forms of small peptides showed more abundant ion peaks for the c{sub n} ions than for the z{sub n}-1 ions. The mechanisms for the N-C{sub {alpha}} bond cleavage are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thermal treatment for recovery of manganese and zinc from zinc-carbon and alkaline spent batteries

Highlights: Black-Right-Pointing-Pointer We separated Zn from Mn in zinc-carbon and alkaline batteries after removal of Hg. Black-Right-Pointing-Pointer Almost total removal of Hg is achieved at low temperature in air. Black-Right-Pointing-Pointer Nitrogen atmosphere is needed to reduce zinc and to permit its volatilization. Black-Right-Pointing-Pointer A high grade Zn concentrate was obtained with a high recovery at 1000-1200 Degree-Sign C. Black-Right-Pointing-Pointer The grade of Mn in the residue was enhanced with complete recovery. - Abstract: The aim of this paper is the recovery of manganese and zinc from a mixture of zinc-carbon and alkaline spent batteries, containing 40.9% of Mn and 30.1% of Zn, after preliminary physical treatment followed by removal of mercury. Separation of the metals has been carried out on the basis of their different boiling points, being 357 Degree-Sign C and 906 Degree-Sign C the boiling point of mercury and zinc and 1564 Degree-Sign C the melting point of Mn{sub 2}O{sub 3}. Characterization by chemical analysis, TGA/DTA and X-ray powder diffraction of the mixture has been carried out after comminution sieving and shaking table treatment to remove the anodic collectors and most of chlorides contained in the mixture. The mixture has been roasted at various temperatures and resident times in a flow of air to set the best conditions to remove mercury that were 400 Degree-Sign C and 10 min. After that, the flow of air has been turned into a nitrogen one (inert atmosphere) and the temperatures raised, thus permitting the zinc oxide to be reduced to metallic zinc by the carbon present in the original mixture and recovered after volatilization as a high grade concentrate, while manganese was left in the residue. The recovery and the grade of the two metals, at 1000 Degree-Sign C and 30 min residence time, were 84% and 100% for zinc and 85% and 63% for manganese, respectively. The recovery of zinc increased to 99% with a grade of 97% at 1200 Degree-Sign C and 30 min residence time, while the recovery and grade of manganese were 86% and 87%, respectively, at that temperature. Moreover, the chlorinated compounds that could form by the combustion of the plastics contained in the spent batteries, are destroyed at the temperature required by the process.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evolution of Functional Groups during Pyrolysis Oil Upgrading

In this paper, we examine the evolution of functional groups (carbonyl, carboxyl, phenol, and hydroxyl) during stabilization at 100–200 °C of two typical wood derived pyrolysis oils from BTG and Amaron in a batch reactor over Ru/C catalyst for 4h. An aqueous and an oily phase were obtained. The content of functional groups in both phases were analyzed by GC/MS, 31P-NMR, 1H-NMR, elemental analysis, KF titration, carbonyl groups by Faix, Folin – Ciocalteu method and UV-Fluorescence. The consumption of hydrogen was between 0.007 and 0.016 g/g oil, and 0.001-0.020 g of CH4/g of oil, 0.005-0.016 g of CO2/g oil and 0.03-0.10 g H2O/g oil were formed. The content of carbonyl, hydroxyl, and carboxyl groups in the volatile GC-MS detectable fraction decreased (80, 65, and ~70% respectively), while their behavior in the total oil and hence in the non-volatile fraction was more complex. The carbonyl groups initially decreased having minimum at ~125-150°C and then increased, while the hydroxyl groups had reversed trend. This might be explained by initial hydrogenation of the carbonyl groups to form hydroxyls, followed by continued dehydration reactions at higher temperatures that may increase their content. The 31P-NMR was on the limit of its sensitivity for the carboxylic groups to precisely detect changes in the non-volatile fraction, however the more precise titration method showed that the concentration of carboxylic groups in the non-volatile fraction remains constant with increased stabilization temperature. The UV-Fluorescence results show that repolymerization increases with temperature. ATR-FTIR method coupled with deconvolution of the region between 1490 and 1850 cm-1 showed to be a good tool for following the changes in carbonyl groups and phenols of the stabilized pyrolysis oils. The deconvolution of the IR bands around 1050 and 1260 cm-1 correlated very well with the changes in the 31P-NMR silent O groups (likely ethers). Most of the H2O formation could be explained from the significant reduction of these silent O groups (from 12% in the fresh oils, to 6 to 2% in the stabilized oils) most probably belonging to ethers.

Stankovikj, Filip↗

Heat capacity measurements of sub-nanoliter volumes of liquids using bimaterial microchannel cantilevers

Lab-on-a-Chip compatible techniques for thermal characterization of miniaturized volumes of liquid analytes are necessary in applications such as protein blotting, DNA melting, and drug development, where samples are either rare or volume-limited. We developed a closed-chamber calorimeter based on a bimaterial microchannel cantilever (BMC) for sub-nanoliter level thermal analysis. When the liquid-filled BMC is irradiated with infrared (IR) light at a specific wavelength, the IR absorption by the liquid analyte results in localized heat generation and the subsequent deflection of the BMC, due to a thermal expansion mismatch between the constituent materials. The time constant of the deflection, which is dependent upon the heat capacity of the liquid analyte, can be directly measured by recording the time-dependent bending of the BMC. We have used the BMC to quantitatively measure the heat capacity of five volatile organic compounds. With a deflection noise level of ∼10 nm and a signal-to-noise ratio of 68:1, the BMC offers a sensitivity of 30.5 ms/(J g{sup −1 }K{sup −1}) and a resolution of 23 mJ/(g K) for ∼150 pl liquid for heat capacity measurements. This technique can be used for small-scale thermal characterization of different chemical and biological samples.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Biorefinery upgrading of herbaceous biomass to renewable hydrocarbon fuels, Part 2: Air pollutant emissions and permitting implications

The development of advanced biofuel production facilities is still at a nascent stage, and the biorefineries could face challenges in obtaining air permits required for their construction and operation because they are novel emission sources. To fill gaps in knowledge regarding potential emissions, we perform a detailed federal regulatory analysis and estimate air pollutant emissions for an advanced biorefinery that produces renewable diesel blendstock (RDB) from lignocellulosic biomass via aerobic respiration documented in Part 1 of the paper. We evaluate 12 design permutations that include two feedstocks, a uniform format blend (UFB) and corn stover; three biorefinery scales, 2,000, 5,200, and 9,100 dry metric tons per day (dmtd) of lignocellulosic biomass feed; and two lignin uses, as either a boiler fuel or for pellet production. We also evaluate 6 additional design permutations by incorporating non-emitting renewable power, which could reduce up to 63% carbon monoxide (CO) and nitrogen oxides (NO x ) each, 21% volatile organic compounds (VOC), and 43% hazardous air pollutants (HAP) as opposed to on-site power production, for biorefineries that produce pellets, using either UFB or corn stover. Our results indicate that all 18 design permutations would be classified as a major source under the Clean Air Act's New Source Review program without additional emission controls. Compared to using lignin as a boiler fuel, diverting lignin for pellet production reduces the emissions of CO up to 88%, NOx up to 73%, sulfur dioxide (SO 2 ) up to 99%, VOCs up to 72%, and HAPs up to 66%. Additionally, we explore control options that could further reduce emissions and assess whether reductions are enough to achieve minor source classification. Insights from our analysis can help biorefinery developers and regulators develop permitting strategies to mitigate investment risks.

09 BIOMASS FUELS↗

Laser-Induced Acoustic Desorption/Electron Ionization of Amino Acids and Small Peptides

Laser-induced acoustic desorption (LIAD) allows for desorption of neutral nonvolatile compounds independent of their volatility or thermal stability. Many different ionization methods have been coupled with LIAD. Hence, this setup provides a better control over the types of ions formed than other mass spectrometry evaporation/ionization methods commonly used to characterize biomolecules, such as ESI or MALDI. In this study, the utility of LIAD coupled with electron ionization (EI) was tested for the analysis of common amino acids with no derivatization. The results compared favorably with previously reported EI mass spectra obtained using thermal desorption/EI. Further, LIAD/EI mass spectra collected for hydrochloride salts of two amino acids were found to be similar to those measured for the neutral amino acids with the exception of the appearance of an HCl{sup +●} ion. However, the hydrochloride salt of arginine showed a distinctly different LIAD/EI mass spectrum than the previously published literature EI mass spectrum, likely due to its highly basic side chain that makes a specific zwitterionic form particularly favorable. Finally, EI mass spectra were measured for seven small peptides, including di-, tri-, and tetrapeptides. These mass spectra show a variety of ion types. However, a{sub n} type ions are prevalent. Also, electron-induced dissociation (EID) of protonated peptides has been reported to form primarily a{sub n} type ions. In addition, the loss of small neutral molecules and side-chain cleavages were observed that are reminiscent of other high-energy fragmentation methods, such as EID. Finally, the isomeric dipeptides LG and IG were found to produce drastically different EI mass spectra, thus allowing differentiation of the leucine and isoleucine amino acids in these dipeptides. .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Tritium Distribution and Capture Requirements for UNF Reprocessing

Four radionuclides have been identified as being sufficiently volatile in reprocessing of nuclear fuel that their gaseous release needs to be controlled to meet U.S. regulatory requirements. These radionuclides are {sup 3}H, {sup 14}C, {sup 85}Kr, and {sup 129}I. Previous studies have discussed the need for treating off-gas streams to control {sup 3}H, {sup 14}C, {sup 85}Kr, and {sup 129}I from the reprocessing of used nuclear fuel (UNF) and the regulations that set the limits for releases from such a facility. These regulations ultimately prescribe the decontamination factor (DF) that must be met in the facility. Jubin et al. examined the role of off-gas pathways since the gaseous radionuclides can partition to different reprocessing off-gas streams. Based on this report and subsequent analysis, the required DF for {sup 129}I could be 1000 to 3000. The required DF for {sup 3}H could be as high as 200, depending on the age of the fuel processed. The DF for {sup 85}Kr could be up to ∼35, also depending on fuel age. The required DF for {sup 14}C is 1 in many cases (no treatment required) but could be higher in specific cases. While iodine has been the focus of a number of studies due to the high DF requirements on multiple escape pathways, it is clear from the studies noted above that the control of tritium will also be a significant issue for future reprocessing plants, especially if processing relatively short-cooled fuels (<10 yr post reactor discharge). Tritium contained in a UNF matrix will be released into the liquid and off-gas streams during fuel reprocessing. The amount released into the process streams is a function of the type and burnup of the fuel processed, and the chemical processes employed within the reprocessing plant. Previous studies have examined the tritium capture requirements for the reprocessing facility assuming that all of the tritium is volatilized in the head-end operations, i.e., tritium pretreatment is employed and tritium is completely released from the cladding. This is clearly a worst case scenario from the standpoint of the amount of tritium that could be released, but the scenario tends to limit the release pathway to the head-end off-gas stream. In this analysis, the volume of HTO and the HTO to H{sub 2}O ratio for each of the three plant-wide tritium DFs were determined. The overall amount of HTO that had to be captured from the off-gas streams was virtually the same for the three DF cases evaluated; 98%, 99% and 99.5% of the tritium in the fuel entering the plant needed to be recovered for overall plant DFs of 50, 100 and 200, respectively. The use of the 'tritium barrier' to limit the spread of HTO from the head-end systems to the balance of the plant results in an increase in tritiated waste concentration in the head-end recycle acid systems which results in a decrease in the total amount of HTO + H{sub 2}O that must recovered from the gaseous effluent from the plant. The use of the 'tritium barrier' decreases the waste volume due to the higher HTO:H{sub 2}O ratio in the treated off-gas stream. The results also show that increasing the acid recycle percentage increases the concentration of HTO within the UNF reprocessing plant. This is then manifested in less HTO + H{sub 2}O that must be recovered from the gaseous effluents. Finally, the application of tritium recovery on the recycle acid reduces the HTO concentration in the recycle acid stream and generates a separate HTO + H{sub 2}O stream that must be managed. However, the resulting volume of tritium-containing waste generated plant-wide is a function of the selectivity of the tritium recovery system and the ability of the tritium recovery system to limit the accumulation of HTO in the recycle acid such that the HTO + H{sub 2}O recovered from gaseous effluents does not contribute significantly to the overall tritium waste volume. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Modular Undersea Compressed Air Energy Storage (UCAES) System

This project has been devoted to the design, optimization, and cost analysis of a unique power plant with integral energy storage. The proposed facility combines a novel underwater compressed air energy storage (UCAES) system with a customized gas turbine generator, providing exceptional power management and overall efficiency. Unlike conventional CAES, opportunities for underwater storage are plentiful and proximal to the power grid. The UCAES system provides coastal and island communities a practical means for managing the volatility of large-scale wind and solar power resources. The result is higher renewable energy absorption and improved electrical reliability with reduced fossil fuel consumption. The UCAES power plant is composed of three major subsystems: The underwater air containment system (ACS), the air transport pipe (ATP), and the land-based power conversion system (PCS). The underwater ACS is made up of modular concrete shell units, structurally optimized for minimal material usage while employing conventional production methods and equipment. Each shell is designed to receive and control loose fill or gravel, serving as the ballast. The static nature of the final structures make them an asset to marine habitats and includes features intended to permit safe and cost-effective deployment. The ATP Connects the ACS modules to each other and to the on-land power conversion system and utilizes high density polyethylene (HDPE) pipe for low cost and long life. The PCS Houses the turbine-generator ‘expander modules’, with peak capacity of 12.3 MWe each, engineered from existing gas turbine equipment and includes electrically driven commercial 3-stage intercooled centrifugal compressors, each nominally drawing 6.6 MWe when matching the turbine flow requirements. The subsystems listed above are designed with the intent to serve as building-blocks to achieve a peak power output rating in the 40 to 120 MWe range, with 0.25 to 4 hours of energy storage capacity. The modular facility with integral energy storage provides some remarkable transient maneuvers and load-following features unachievable by competing technologies. The system can operate as a dispatchable power plant with a fuel-to-electric efficiency over 41%; substantially better that the average existing Hawaiian peak power generation assets. Optimal efficiency can be maintained while load-following due to modular PCS design and is operable with a range of liquid or gaseous fuels while meeting the most stringent California (CARB) emission standards. The system can operate as a peaking energy plant in discharge mode. Power ramp-up equivalent to 215% of continuous load rating within 1 second accomplished by simply turning off the electric compressor(s). Contrarily, the system can offer energy absorption during periods of grid surplus generation. The electric compressors may be sequenced on to absorb power within seconds. More moderate transitions are easily achieved with standard compressor control functions. The system offers unique features as compared to energy storage systems. ‘Round-trip efficiency’, as calculated by industry standard methods, is in the 90% range. The PCS equipment has a mean-time between overhauls of 80,000 hours, with maintenance costs of less than $0.005/kW-hr of electricity delivered. The underwater ACS structures and piping employ materials and designs specified to achieve a 75 year life. With the underwater containment modules qualified as a marine habitat, there would be no decommissioning costs. In conjunction with the engineering work invested in the design of the UCAES power plant, Brayton Energy has employed a team of manufacturing specialists, marine construction engineers, and power industry experts to create a comprehensive economic model that captures the many site-related variables and configuration options. The cost results and methodology have been validated by suppliers, engineers, and deployment specialists through a detailed case study on Hawaii. While creation of the parametric cost model was based on inputs specific to Hawaii, the proposed construction and deployment steps were chosen to be general enough to allow extrapolation across locations world-wide. Analysis of the proposed system shows it to be a viable option and addresses the principal challenges described by the Department of Energy by offering competitive costs, validated safety and reliability, consideration of the regulatory environment, and utilization of industry accepted practices and equipment. The UCAES system is recommended for immediate consideration in Hawaii. Estimation of time to complete planning, design, and construction of the facility is anticipated to take 3 to 5 years. Other coastal and island communities world-wide should realize similar benefits; as the results presented in this report are considered generally transferable to other locations.

24 POWER TRANSMISSION AND DISTRIBUTION↗