Search NASA⌕ Search

SEARCH · Search NASA

Results for “WAVE FORMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Broad Separation of Isomeric Lipids by High-Resolution Differential Ion Mobility Spectrometry with Tandem Mass Spectrometry

Maturation of metabolomics has brought a deeper appreciation for the importance of isomeric identity of lipids to their biological role, mirroring that for proteoforms in proteomics. However, full characterization of the lipid isomerism has been thwarted by paucity of rapid and effective analytical tools. A novel approach is ion mobility spectrometry (IMS) and particularly differential or field asymmetric waveform IMS (FAIMS) at high electric fields, which is more orthogonal to mass spectrometry. Here we broadly explore the power of FAIMS to separate lipid isomers, and find a ~75% success rate across the four major types of glycero- and phospho- lipids (sn, chain length, double bond position, and cis/trans). The resolved isomers were identified using standards, and (for the first two types) tandem mass spectrometry. These results demonstrate the general merit of incorporating high-resolution FAIMS into lipidomic analyses. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Maximizing Ion Transmission in Differential Mobility Spectrometry

We provide modeling and experimental data describing the dominant ion-loss mechanisms for differential mobility spectrometry (DMS). Ion motion is considered from the inlet region of the mobility analyzer to the DMS exit, and losses resulting from diffusion to electrode surfaces, insufficient effective gap, ion fragmentation, and fringing field effects are considered for a commercial DMS system with 1-mm gap height. It is shown that losses due to diffusion and radial oscillations can be minimized with careful consideration of residence time, electrode spacing, gas flow rate, and waveform frequency. Fragmentation effects can be minimized by limitation of the separation field. When these parameters were optimized, fringing field effects at the DMS inlet contributed the most to signal reduction. We also describe a new DMS cell configuration that improves the gas dynamics at the mobility cell inlet. The new cell provides a gas jet that decreases the residence time for ions within the fringing field region, resulting in at least twofold increase in ion signal as determined by experimental data and simulations. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Digital Waveform Technology and the Next Generation of Mass Spectrometers

Ion traps and guides are integral parts of current commercial mass spectrometers. They are currently operated with sinusoidal waveform technology that has been developed over many years. Recently, digital waveform technology has begun to emerge and promises to supplant its older cousin because it presents new capabilities that result from the ability to instantaneously switch the frequency and duty cycle of the waveforms. This manuscript examines these capabilities and reveals their uses and effects on instrumentation. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Implementation of Precursor and Neutral Loss Scans on a Miniature Ion Trap Mass Spectrometer and Performance Comparison to a Benchtop Linear Ion Trap

Implementation of orthogonal double resonance precursor and neutral loss scans on the Mini 12 miniature rectilinear ion trap mass spectrometer is described, and performance is compared to that of a commercial Thermo linear trap quadropole (LTQ) linear ion trap. The ac frequency scan version of the technique at constant rf voltage is used here because it is operationally much simpler to implement. Remarkably, the Mini 12 shows up to two orders of magnitude higher sensitivity compared to that of the LTQ. Resolution on the LTQ is better than unit at scan speeds of ~ 400 Th/s, whereas peak widths on the Mini 12, on average, range from 0.5 to 2.0 Th full width at half maximum and depend heavily on the precursor ion Mathieu q parameter as well as the pump down time that precedes the mass scan. Both sensitivity and resolution are maximized under higher pressure conditions (short pump down time) on the Mini 12. The effective mass range of the product ion ejection waveform was found to be 5.8 Th on the Mini 12 in the precursor ion scan mode vs. that of 3.9 Th on the LTQ. In the neutral loss scan mode, the product ion selectivity was between 8 and 11 Th on the Mini 12 and between 7 and 8 Th on the LTQ. The effects of nonlinear resonance lines on the Mini 12 were also explored. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved Quantitative Dynamic Range of Time-of-Flight Mass Spectrometry by Simultaneously Waveform-Averaging and Ion-Counting Data Acquisition

Two different types of data acquisition methods, “averaging mode” and “ion-counting mode”, have been used in a time-of-flight (TOF) mass spectrometry. The most common method is an averaging mode that sums waveform signals obtained from each flight cycle. While it is possible to process many ions arriving at the same TOF in one flight cycle, low-abundance ions are difficult to measure because ion signals are overwhelmed by noises from the detection system. An ion-counting mode is suitable for the detection of such low-concentration ions, but counting loss occurs when two or more ions arrive at the detector within the dead time of the acquisition system. In this study, we introduce a technique that combines two methods to measure target ions with a high concentration difference, i.e., averaging mode and ion-counting mode are used simultaneously for high abundant and trace ions, respectively. By processing waveforms concurrently during data acquisition, one can choose to analyze either or both types of data to achieve a highly quantitative mass spectrum over a wide range of sample concentrations. The result of the argon isotope analysis shows that this method provides a more accurate determination of the isotope ratio compared to averaging mode alone at one-twentieth of the analysis time required by ion-counting alone. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Differential Mobility Spectrometry-Mass Spectrometry (DMS-MS) in Radiation Biodosimetry: Rapid and High-Throughput Quantitation of Multiple Radiation Biomarkers in Nonhuman Primate Urine

High-throughput methods to assess radiation exposure are a priority due to concerns that include nuclear power accidents, the spread of nuclear weapon capability, and the risk of terrorist attacks. Metabolomics, the assessment of small molecules in an easily accessible sample, is the most recent method to be applied for the identification of biomarkers of the biological radiation response with a useful dose-response profile. Profiling for biomarker identification is frequently done using an LC-MS platform which has limited throughput due to the time-consuming nature of chromatography. We present here a chromatography-free simplified method for quantitative analysis of seven metabolites in urine with radiation dose-response using urine samples provided from the Pannkuk et al. (2015) study of long-term (7-day) radiation response in nonhuman primates (NHP). The stable isotope dilution (SID) analytical method consists of sample preparation by strong cation exchange-solid phase extraction (SCX-SPE) to remove interferences and concentrate the metabolites of interest, followed by differential mobility spectrometry (DMS) ion filtration to select the ion of interest and reduce chemical background, followed by mass spectrometry (overall SID-SPE-DMS-MS). Since no chromatography is used, calibration curves were prepared rapidly, in under 2 h (including SPE) for six simultaneously analyzed radiation biomarkers. The seventh, creatinine, was measured separately after 2500× dilution. Creatinine plays a dual role, measuring kidney glomerular filtration rate (GFR), and indicating kidney damage at high doses. The current quantitative method using SID-SPE-DMS-MS provides throughput which is 7.5 to 30 times higher than that of LC-MS and provides a path to pre-clinical radiation dose estimation. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using Digital Waveforms to Mitigate Solvent Clustering During Mass Filter Analysis of Proteins

With advances in the precision of digital electronics, waveform generation technology has progressed to a state that enables the creation of m/z filters that are purely digitally driven. These advances present new methods of performing mass analyses that provide information from a chemical system that are inherently difficult to achieve by other means. One notable characteristic of digitally driven mass filters is the capacity to transmit ions at m/z ratios that vastly exceed the capabilities of traditional resonant systems. However, the capacity to probe ion m/z ratios that span multiple orders of magnitudes across multiple orders of magnitude presents a new set of issues requiring a solution. In the present work, when probing multiply charged protein species beyond m/z 2000 using a gentle atmospheric pressure interface, the presence of solvent adducts and poorly resolved multimers can severely degrade spectral fidelity. Increasing energy imparted into a target ion population is one approach minimizing these clusters; however, the use of digital waveform technology provides an alternative that maximizes ion transport efficiency and simultaneously minimizes solvent clustering. In addition to the frequency of the applied waveform, digital manipulation also provides control over the duty cycle of the target waveform. This work examines the conditions and approach leading to optimal digital waveform operation to minimize solvent clustering. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Operation and Performance of a Mass-Selective Cryogenic Linear Ion Trap

We report on the performance of a cryogenic 2D linear ion trap (cryoLIT) that is shown to be mass-selective in the temperature range of 17–295 K. As the cryoLIT is cooled, the ejection voltages during the mass instability scan decrease, which results in an effective mass shift to lower m/z relative to room temperature. This is attributed to a decrease in trap radius caused by thermal contraction. Additionally, the cryoLIT generates reproducible mass spectra from day-to-day, and is capable of performing stored waveform inverse Fourier transform (SWIFT) mass isolation of fragile N{sub 2}-tagged ions for the purpose of background-free infrared dissociation spectroscopy. .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Increasing the Upper Mass/Charge Limit of a Quadrupole Ion Trap for Ion/Ion Reaction Product Analysis via Waveform Switching

Quadrupole ion traps (QITs) are versatile platforms for performing experiments with gas-phase ions due to their abilities to store ions of both polarities and to conduct MS{sup n} experiments. The QIT is particularly useful as a reaction cell for ion/ion reactions. In the case of an ion/ion reaction experiment in a QIT, multiply charged reactant ions may initially be of relatively low m/z (e.g., m/z < 1000) whereas the product ions can be one or more orders of magnitude higher in m/z (e.g., m/z > 100,000). Several factors can limit the m/z range over which an ion/ion reaction experiment can be conducted. These include (1) the efficiency of the detector, (2) the m/z range over which oppositely charged ions can be mutually stored, and (3) the m/z range over which ions can be mass selectively ejected into an external detector. High-frequency waveforms provide larger m/z trapping ranges for mutual storage of oppositely charged ions whereas low-frequency waveforms provide better trapping for very high m/z product ions. Presented here is a method that switches from a high-frequency sine wave prior to and during an ion/ion reaction to a low-frequency square wave to eject low m/z reagent ions and improves confinement of the product ions before mass-selective ejection by scanning the frequency of the square wave. This approach addresses the third issue, which is the primary limiting factor with QITs operated at high RF (e.g., > 900 MHz). .

74 ATOMIC AND MOLECULAR PHYSICS↗

A multigrid waveform relaxation method for solving the poroelasticity equations

In this work, a multigrid waveform relaxation method is proposed for solving a collocated finite difference discretization of the linear Biot’s model. This gives rise to the first space–time multigrid solver for poroelasticity equations in the literature. The waveform relaxation iteration is based on a point-wise Vanka smoother that couples the pressure variable at a grid-point with the displacements around it. A semi-algebraic mode analysis is proposed to theoretically analyze the convergence of the multigrid waveform relaxation algorithm. This analysis is novel since it combines the semi-algebraic analysis, suitable for parabolic problems, with the non-standard analysis for overlapping smoothers. The practical utility of the method is illustrated through several numerical experiments in one and two dimensions.

97 MATHEMATICS AND COMPUTING↗

The morphology of electrostatic tripolar regions

Electrostatic tripolar regions in plasmas develop a skewness of their own electric potential waveform as a peculiar morphological property, which distinguishes them from symmetric electrostatic solitary waves. Within the collision-less, kinetic treatment developed here, this property holds if the velocity distributions of electrons and ions are singular in value, irrespective of their smoothness at the region's boundary and of the smoothness of the potential waveform and of the electron and ion density distributions. These singularities are integrable, and are of the logarithmic and jump type: the former occur at isolated points in phase space; the latter occur on the left branch of the electron separatrix and on the left branch of the ion sub-separatrix. The distributions are non-negative if, at its local extrema, the potential waveform is skewed to the left, in agreement with observations, and if the skewness is smaller than a given bound: a sufficient condition for such skewness to be small about the minimum of the potential waveform is that a sufficiently fast electron beam exists on the high-potential boundary of the tripolar region. In those special cases in which the particle distributions are continuous in value, the above mentioned singularities affect their space and velocity derivatives. These results could be extracted from very general considerations on the degree of smoothness of the spatial distribution of the electric potential and on the non-negativity of the electron and ion distributions, without the assistance of any specific models.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An investigation of the multi-mode Richtmyer-Meshkov instability at a gas/HE interface using Pagosa

Here, in this work, we present a hydrocode Pagosa and explore the Richtmyer-Meshkov Instability (RMI) at an air/high explosive (HE) interface for the first time that is important but has not received much attention yet in the high explosive safety field. Thus, the presented Pagosa can be expected to predict the whole deflagration-to-detonation transition (DDT) process in future. In Pagosa, spatial discretization is implemented on cubic staggered grids by computing different variables at the vertex and the cell center, respectively, a special operator-splitting technique is employed to reduce the computational cost, and an artificial viscosity is added to handle the discontinuous shock waves in our simulations. To quantitatively evaluate the capability of Pagosa to solve these kinds of instabilities, the single mode Rayleigh-Taylor instability (RTI) and the multimode RMI at an air/SF 6 interface are first performed, respectively. The Pagosa results are compared with the related numerical solutions in the existing references and the experimental result. Moreover, a theoretical derivation of growth of RTI is also provided based on our numerical method. Subsequently, we explore the multi-mode RMI at an air/HE interface as well as the effects of several factors using Pagosa. Numerical results show that Pagosa is a powerful toolset to generate the right structures and the amplitude of RTI and RMI at an air/SF 6 interface. The solid HE can be penetrated by a strong shock wave and forms RMI deformations. The RMI at an air/HE interface behaves very different than at an air/SF 6 interface, periodic, decreased oscillation is observed due to material character, and is very sensitive to the initial simulation settings, that is, a tiny change in physical quantities will lead to a remarkable RMI structure, which is also observed in a shock bubble interaction. The findings in this work are significant, and will present a new insight for the high explosive field.

97 MATHEMATICS AND COMPUTING↗

The nonlinear response of inverted ''V'' flames to equivalence ratio nonuniformities

Recent studies indicate that heat release fluctuations generated by equivalence ratio perturbations may constitute sources of instability with effects similar to those induced by acoustic perturbations. The present article addresses this issue by considering the dynamics of an inverted laminar dihedral (''V'') flame spreading in an open geometry when this flame is submitted to equivalence ratio modulations. The problem is investigated with numerical simulations by first establishing a steady state flame which then evolves in a uniform flow transporting a fixed level of equivalence ratio perturbations. The flame features wrinkles of increasing amplitude locking on the convected composition perturbations. The wrinkling amplitude grows with distance from the injector. For sufficiently large wrinkle amplitudes, the flame interacts with the fresh mixture outer boundary, giving rise to sudden disruptions of the flame sheet. The rapid burning of fresh mixture pockets generates a nonlinear heat release signal with abrupt changes in the waveform. It is found that high levels of modulation induce axial velocity perturbations, which in turn interact with the flame and modify the response. Calculations described in this article may serve to guide analytical modeling of the response of combustion to equivalence ratio inhomogeneities. A simple model is devised on this basis to distinguish regimes corresponding to weak and strong interactions. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Novel Phase-Coherent Programmable Clock for High-Precision Arbitrary Waveform Generation Applied to Digital Ion Trap Mass Spectrometry

Digital ion trap (DIT) mass spectrometry requires the ability to precisely and accurately produce waveforms. The quality of the mass spectra produced in terms of resolution and mass accuracy depend on the resolution and precision of the applied waveforms. This publication reveals a novel method for the production of arbitrary waveforms in general and then applies the method to the production of DIT waveforms. Arbitrary waveforms can be created by varying the clock frequency input to a programmable read only memory that is then input to a digital-to-analog converter (DAC). The arbitrary waveform is composed of a defined number of points that are triggered to be written after programmed numbers of clock cycles to define the arbitrary waveform. The novelty introduced here is that the direct digital synthesis (DDS) generated clock frequency can be precisely changed as the arbitrary waveform is written because we have developed a method to rapidly switch the DDS frequency exactly at the end of the output clock cycle allowing exact timing of multiple transitions to produce precise and temporally complex waveforms. Changing the frequency only at the end of the output clock cycle is a phase coherent process that permits precise timing between each point in the arbitrary waveform. The waveform generation technique was demonstrated by creating a prototype that was used to operate a digital ion trap mass spectrometer. The jitter in the phase-coherent DDS TTL output that was used as the frequency variable clock was 20 ps. This jitter represents the realizable limit of precision for waveform generation. The rectangular waveforms used to operate the mass spectrometer were created with counters that increased the jitter to 100 ps. The mass resolution achieved was 5000 at m/z = 414. This resolution corresponds to a jitter of 275 ps assuming DC fluctuations and overshoots in the waveform are insignificant. Resolution should improve with increasing mass because the waveforms have longer periods while the jitter should remain constant. Given the current limit of the variable clock resolution, much better mass resolution should be achievable with future generations of the waveform production system. The agility of the DDS function generators permits the phase-coherent variable clock to be switched at a rate up to 250 MHz. This permits arbitrary waveforms to be produced with much more temporal complexity than previously possible.

47 OTHER INSTRUMENTATION↗

Novel Super-Resolution Approach to Time-Resolved Volumetric 4-Dimensional Magnetic Resonance Imaging With High Spatiotemporal Resolution for Multi-Breathing Cycle Motion Assessment

Purpose: To develop and evaluate a super-resolution approach to reconstruct time-resolved 4-dimensional magnetic resonance imaging (TR-4DMRI) with a high spatiotemporal resolution for multi-breathing cycle motion assessment. Methods and Materials: A super-resolution approach was developed to combine fast 3-dimensional (3D) cine MRI with low resolution during free breathing (FB) and high-resolution 3D static MRI during breath hold (BH) using deformable image registration. A T1-weighted, turbo field echo sequence, coronal 3D cine acquisition, partial Fourier approximation, and SENSitivity Encoding parallel acceleration were used. The same MRI pulse sequence, field of view, and acceleration techniques were applied in both FB and BH acquisitions; the intensity-based Demons deformable image registration method was used. Under an institutional review board–approved protocol, 7 volunteers were studied with 3D cine FB scan (voxel size: 5 × 5 × 5 mm{sup 3}) at 2 Hz for 40 seconds and a 3D static BH scan (2 × 2 × 2 mm{sup 3}). To examine the image fidelity of 3D cine and super-resolution TR-4DMRI, a mobile gel phantom with multi-internal targets was scanned at 3 speeds and compared with the 3D static image. Image similarity among 3D cine, 4DMRI, and 3D static was evaluated visually using difference image and quantitatively using voxel intensity correlation and Dice index (phantom only). Multi-breathing-cycle waveforms were extracted and compared in both phantom and volunteer images using the 3D cine as the references. Results: Mild imaging artifacts were found in the 3D cine and TR-4DMRI of the mobile gel phantom with a Dice index of >0.95. Among 7 volunteers, the super-resolution TR-4DMRI yielded high voxel-intensity correlation (0.92 ± 0.05) and low voxel-intensity difference (<0.05). The detected motion differences between TR-4DMRI and 3D cine were −0.2 ± 0.5 mm (phantom) and −0.2 ± 1.9 mm (diaphragms). Conclusion: Super-resolution TR-4DMRI has been reconstructed with adequate temporal (2 Hz) and spatial (2 × 2 × 2 mm{sup 3}) resolutions. Further TR-4DMRI characterization and improvement are necessary before clinical applications. Multi-breathing cycles can be examined, providing patient-specific breathing irregularities and motion statistics for future 4D radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dynamic Collision-Induced Dissociation (DCID) in a Quadrupole Ion Trap Using a Two-Frequency Excitation Waveform: II. Effects of Frequency Spacing and Scan Rate

Dynamic CID of selected precursor ions is achieved by the application of a two-frequency excitation waveform to the end-cap electrodes during the mass instability scan of a quadrupole ion trap mass spectrometer (QIT-MS). The time period normally allotted for resonance excitation and collisional cooling of the trapped ion are excluded and fragmentation instead takes place simultaneously with the mass acquisition scan. This new method permits a shorter scanning time when compared to conventional on-resonance CID. When the excitation waveform consists of two closely-spaced frequencies, the relative phase-relationship of the two frequencies plays a critical role in the fragmentation dynamics. However, at wider frequency spacings (>8 kHz) these phase effects are diminished, while maintaining the efficacy of closely-spaced excitation frequencies. The fragmentation efficiencies and energetics of n-butylbenzene and tetraalanine are studied under different experimental conditions and the results are compared at various scan rate parameters between 0.1 and 1.0 ms/Th. Although faster scan rates reduce the analysis time, the maximum observed fragmentation efficiencies rarely exceed 30%, compared to values in excess of 50% achieved at slower scan rates. The internal energies calculated from the simulations of n-butylbenzene at fast scan rates are ~4 eV for most experimental conditions, while at slow scan rates internal energies above 5.5 eV are observed for a wide range of conditions. Extensive ITSIM simulations support the observation that slowing the scan rate has a similar effect on fragmentation as widening the frequency spacing between the two excitation frequencies. Both approaches generally enhance CID efficiencies and make fragmentation less dependent upon the relative phase angle between the excitation waveform and the ion motion. This could be useful for optimizing the CID efficiencies for a wide range of precursor ion mass-to-charge ratios.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimum Waveforms for Differential Ion Mobility Spectrometry (FAIMS)

Differential mobility spectrometry or field asymmetric waveform ion mobility spectrometry (FAIMS) has emerged as a major tool for separation and identification of gas-phase ions, particularly in conjunction with mass-spectrometry. In FAIMS, ions are filtered by the difference between mobilities in gases (K) at high and low electric field intensity (E) using asymmetric waveforms. An infinite number of waveform profiles is possible and maximizing the performance within engineering constraints is a major issue in FAIMS technology development. Earlier optimizations assumed the non-constant component of mobility to scale as E2, producing the same result for all ions. Here we show that the optimum profiles for either rectangular or sinusoidal-based waveforms are controlled by the full series expansion of K(E) that always includes terms beyond the 1st proportional to E2. For many ion/gas pairs, the first two terms have different signs and the optimum profiles at sufficiently high E in FAIMS may substantially differ from those found previously, improving the resolving power by up to 2 - 2.5 times. This situation arises for some ions in all FAIMS systems, but becomes more common with recent miniaturized units that employ higher E. With realistic K(E) dependences, the maximum waveform amplitude is not necessarily best and reducing it by up to 20 - 30% is beneficial in some cases. Present findings are particularly relevant to targeted analyses where separation depends on the spread between K(E) functions of specific ions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A new fourth-order Fourier-Bessel split-step method for the extended nonlinear Schroedinger equation

Fourier split-step techniques are often used to compute soliton-like numerical solutions of the nonlinear Schroedinger equation. Here, a new fourth-order implementation of the Fourier split-step algorithm is described for problems possessing azimuthal symmetry in 3 + 1-dimensions. This implementation is based, in part, on a finite difference approximation {delta}{sub perpendicular} {sup FDA} of 1/r ({partial_derivative})/({partial_derivative}r) r({partial_derivative})/({partial_derivative}r) that possesses an associated exact unitary representation of e{sup i/2{lambda}}{sup {delta}{sub perpendicular}{sup FDA}}. The matrix elements of this unitary matrix are given by special functions known as the associated Bessel functions. Hence the attribute Fourier-Bessel for the method. The Fourier-Bessel algorithm is shown to be unitary and unconditionally stable. The Fourier-Bessel algorithm is employed to simulate the propagation of a periodic series of short laser pulses through a nonlinear medium. This numerical simulation calculates waveform intensity profiles in a sequence of planes that are transverse to the general propagation direction, and labeled by the cylindrical coordinate z. These profiles exhibit a series of isolated pulses that are offset from the time origin by characteristic times, and provide evidence for a physical effect that may be loosely termed normal mode condensation. Normal mode condensation is consistent with experimentally observed pulse filamentation into a packet of short bursts, which may occur as a result of short, intense irradiation of a medium.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗