Search NASA⌕ Search

SEARCH · Search NASA

Results for “X ray”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Soft X-rays from the Large Magellanic Cloud - Implications on the origin of the diffuse X-ray background

A total soft X-ray luminosity of approximately 10 to the 38th power ergs/s was observed from the Large Magellanic Cloud (LMC) during pointed rocket observations in November 1973. Simple spectral parameters are derived and discussed. Upper limits at 1 KeV to several known LMC point sources are presented. A diffuse bar source reported previously was not detected. Strong limits are placed on the fraction of halo and extragalactic diffuse X-ray flux observed in the direction of the LMC due to the lack of correlation of the 0.25-KeV diffuse flux with interstellar hydrogen in the Galaxy and in the LMC.

Long, K. S.↗

The asymmetric 4.8 hour X-ray modulation of Cygnus X-3 - Model light curves and inferred orbital parameters

The 4.8 hour X-ray light curve of Cygnus X-3 is quantitatively described by several proposed models under the assumption that the binary orbit of Cyg X-3 is elliptic. The cocoon model implies an apparent size for the X-ray star's companion, which is larger than that of its critical lobe, and it is suggested that the emission of a dense stellar wind by the companion could lead to such a situation. It is shown that a helium star, with or without a hydrogen-rich envelope, seems to be the most likely Cyg X-3 companion, and that some of the observed variations in the 4.8 hour period can be accounted for by the apparent period variations due to apsidal motion.

Ghosh, P.↗

NASA's Future X-ray Missions: From Constellation-X to Generation-X

Among the most important topics in modern astrophysics are the formation and evolution of supermassive black holes in concert with galaxy bulges, the nature of the dark energy equation of state, and the self-regulating symmetry imposed by both stellar and AGN feedback. All of these topics are readily addressed with observations at X-ray wavelengths. NASA's next major X-ray observatory is Constellation-X, which is being developed to perform spatially resolved high-resolution X-ray spectroscopy. Con-X will directly measure the physical properties of material near black holes' last stable orbits and the absolute element abundances and velocities of hot gas in clusters of galaxies. The Con-X mission will be described, as well as its successor, Generation-X (anticipated to fly approx.1 decade after Con-X). After describing these missions and their driving science areas, the talk will focus on areas in which Chandra observing programs may enable science with future X-ray observatories. These areas include a possible ultra-deep Chandra imaging survey as an early Universe pathfinder, a large program to spatially resolve the hot intracluster medium of massive clusters to aid dark energy measurements, and possible deep spectroscopic observations to aid in preparatory theoretical atomic physics work needed for interpreting Con-X spectra.

Hornschemeier, A.↗

Evidence for a 115 Day Orbital Period in the Ultraluminous X-ray Source NGC 5408 X-1

We report the detection of a 115 day periodicity in SWIFT/XRT monitoring data from the ultraluminous X-ray source (ULX) NGC 5408 X-1. Our ongoing campaign samples its X-ray flux approximately twice weekly and has now achieved a temporal baseline of more than 500 days. Timing analysis reveals a significant periodicity with a period of 115.5 +- 4 days. The fractional modulation amplitude decreases with increasing energy, ranging from 0.13 above 1 keV to 0.24 below 1 keV. The shape of the profile evolves as well, becoming less sharply peaked at higher energies. Periodogram analysis is consistent with a periodic process, however, continued monitoring is required to confirm the coherent nature of the modulation. Spectral analysis indicates that NGC 5408 X-1 can reach 0.3 - 10 keV luminosities of 2 x 10e40 ergs/s. We suggest that, like the 62 day period of the ULX in M82 (X41.4+60), the periodicity detected in NGC 5408 X-1 represents the orbital period of the black hole binary containing the ULX. If this is true then the secondary can only be a giant or supergiant star.

Strohmayer, T.↗

Soft x-ray absorption spectroscopy and magnetic circular dichroism as operando probes of complex oxide electrolyte gate transistors

Electrolyte-based transistors utilizing ionic liquids/gels have been highly successful in the study of charge-density-controlled phenomena, particularly in oxides. Experimental probes beyond transport have played a significant role, despite challenges in their application in electric double-layer transistors. Here, we demonstrate the application of synchrotron soft x-ray absorption spectroscopy (XAS) and x-ray magnetic circular dichroism (XMCD) as operando probes of the charge state and magnetism in ion-gel-gated ferromagnetic perovskite films. Electrochemical response via oxygen vacancies at positive gate bias in LaAlO 3 (001)/La 0.5 Sr 0.5 CoO 3-δ is used as a test case. XAS/XMCD measurements of 4–25 unit-cell-thick films first probe the evolution of hole doping (from the O K-edge pre-peak) and ferromagnetism (at the Co L-edges), to establish a baseline. Operando soft XAS/XMCD of electrolyte-gated films is then demonstrated, using optimized spin-coated gels with a thickness of ~1 μm and a specific composition. The application of gate voltages up to +4 V is shown to dramatically suppress the O K-edge XAS pre-peak intensity and Co L-edge XMCD, thus enabling the Co valence and ferromagnetism to be tracked upon gate-induced reduction. Soft XAS and XMCD, with appropriate electrolyte design, are thus established to be viable for the operando characterization of electrolyte-gated oxides.

Yu, Biqiong↗

Motorized Beam Alignment of a Commercial X-ray Diffractometer

X-ray diffraction (XRD) is a powerful analysis method that allows researchers to noninvasively probe the crystalline structure of a material. This includes the ability to determine the crystalline phases present, quantify surface residual stresses, and measure the distribution of crystallographic orientations. The Structures and Materials Division at the NASA Glenn Research Center (GRC) heavily uses the on-site XRD lab to characterize advanced metal alloys, ceramics, and polymers. One of the x-ray diffractometers in the XRD lab (Bruker D8 Discover) uses three different x-ray tubes (Cu, Cr, and Mn) for optimal performance over numerous material types and various experimental techniques. This requires that the tubes be switched out and aligned between experiments. This alignment maximizes the x-ray tube s output through an iterative process involving four set screws. However, the output of the x-ray tube cannot be monitored during the adjustment process due to standard radiation safety engineering controls that prevent exposure to the x-ray beam when the diffractometer doors are open. Therefore, the adjustment process is a very tedious series of blind adjustments, each followed by measurement of the output beam using a PIN diode after the enclosure doors are shut. This process can take up to 4 hr to perform. This technical memorandum documents an in-house project to motorize this alignment process. Unlike a human, motors are not harmed by x-ray radiation of the energy range used in this instrument. Therefore, using motors to adjust the set screws will allow the researcher to monitor the x-ray tube s output while making interactive adjustments from outside the diffractometer. The motorized alignment system consists of four motors, a motor controller, and a hand-held user interface module. Our goal was to reduce the alignment time to less than 30 min. The time available was the 10-week span of the Lewis' Educational and Research Collaborative Internship Project (LERCIP) summer internship program and the budget goal was $1200. In this report, we will describe our motorization design and discuss the results of its implementation.

Van Zandt, Noah R.↗

Origin of cosmic X rays.

X-ray astronomy emphasizing interpretation of observational results and relationship to radio and optical astronomy and cosmic ray physics

RADIO ASTRONOMY↗

A Comprehensive Spectral Analysis of the X-Ray Pulsar 4U 1907+09 from Two Observations with the Suzaku X-Ray Observatory

We present results from two observations of the wind-accreting X-ray pulsar 4U 1907+09 using the Suzaku observatory, The broadband time-averaged spectrum allows us to examine the continuum emission of the source and the cyclotron resonance scattering feature at approx. 19 keV. Additionally, using the narrow CCD response of Suzaku near 6 ke V allows us to study in detail the Fe K bandpass and to quantify the Fe Kp line for this source for the first time. The source is absorbed by fully-covering material along the line of sight with a column density of N(sub H) approx. 2 x 10(exp 22)/sq cm, consistent with a wind accreting geometry, and a high Fe abundance (approx. 3 - 4 x solar). Time and phase-resolved analyses allow us to study variations in the source spectrum. In particular, dips found in the 2006 observation which are consistent with earlier observations occur in the hard X-ray bandpass, implying a variation of the whole continuum rather than occultation by intervening material, while a dip near the end of the 2007 observation occurs mainly in the lower energies implying an increase in NH along the line of sight, perhaps indicating clumpiness in the stellar wind

Rivers, Elizabeth↗

Neutron and x-ray computed tomography of a natural uranium tristructural isotropic (TRISO) fuel compact

A natural uranium-based, unirradiated tristructural isotropic (TRISO) fuel compact was nondestructively imaged using both X-ray (XCT) and neutron computed tomography (nCT). While XCT of compacts can provide information on fuel kernels, imaging artifacts preclude examination of the graphite matrix. In this work, nCT was used for the first time on a TRISO compact to examine the graphite matrix. A crack was clearly resolved within the graphite matrix, proving that nCT is a viable tool for nondestructive volumetric examination of the matrix material in TRISO fuel compacts. The XCT and nCT data were then fused together to create a more comprehensive dataset containing both matrix and fuel kernels.

36 - MATERIALS SCIENCE↗

Quantitative uranium elemental reconstruction using spectral x-ray radiography

X-ray radiography offers the ability to noninvasively inspect the internal structure and material composition of objects. Dual-energy radiography allows material discrimination but is limited in quantitative material measurements due to the broad nature of the interrogating x-ray spectrum. Spectral radiography detectors provide an observation of not just the number of x rays that are transmitted through a sample but also the spectrum. Here, experimental validations of a method to use spectral x-ray radiography to accurately quantify the uranium mass in a powder are presented. An accurate system response model was developed, which includes a model of the incident x-ray source spectrum and a pixel-wise detector response that describes how the transmitted x rays were observed. Further, a calibration to account for the effect of partial x-ray attenuation was developed. As a result, the method is demonstrated to be capable of estimating the uranium mass in a variety of uranium oxide powders to a bias of –0.01±0.62%.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A Comparison of Cs-137 γ Rays and 320-kV X-Rays in a Mouse Bone Marrow Transplantation Model

US homeland security concerns regarding the potential misuse of some radiation sources used in radiobiological research, for example, cesium-137 ( 137 Cs), have resulted in recommendations by the National Research Council to conduct studies into replacing these sources with suitable X-ray instruments. The objective of this research is to compare the effectiveness of an X-RAD 320 irradiator (PXINC 2010) with a 137 Cs irradiator (Gammacell-1000 Unit) using an established bone marrow chimeric model. Using measured radiation doses for each instrument, we characterized the dose–response relationships for bone marrow and splenocyte ablation, using a cytotoxicity-hazard model. Our results show that the X-RAD 320 photon energy spectrum was suitable for ablating bone marrow at the 3 exposure levels used, similar to that of 137 Cs photons. However, the 320-kV X-rays were not as effective as the much higher energy γ rays at depleting mouse splenocytes. Furthermore, the 3 X-ray levels used were less effective than the higher energy γ rays in allowing the successful engraftment of donor bone marrow, potentially as a result of the incomplete depletion of the spleen cells. More defined studies are warranted for determining whether bone marrow transplantation in mice can be successfully achieved using 320-kV X-rays. A higher X-ray dose then used is likely needed for transplantation success.

320-kV X-rays↗

The next-generation particle x-ray temporal diagnostic for simultaneous time-resolved measurements of nuclear-burn and x-ray emission histories in support of basic-science and inertial confinement fusion experiments at OMEGA

The next-generation Particle X-ray Temporal Diagnostic (PXTD) has been implemented for simultaneous measurements of x-ray, charged particle, and neutron emission histories from a wide range of inertial confinement fusion and high energy density plasma experiments, demonstrating excellent timing accuracy and greatly improved experimental flexibility. The key changes to the previously fielded system are a redesigned set of thin foil filters in front of the scintillators and individual neutral density filters for each region of the detector. The fully implemented PXTD system can provide unique information about the evolution of ion and electron temperatures in multi-ion and kinetic-physics experiments, proton radiography experiments, and DT experiments executed at the OMEGA facility. The system has 35 ps time resolution and negligible relative timing uncertainty between measured emission history signals. The first use of the upgraded four-channel PXTD system during a set of D 3 He-filled silica-glass implosions on OMEGA captured electron temperatures with a minimum uncertainty of 0.5 keV and resolved both the relative timings and widths of neutron, proton, and x-ray peaks within a single recorded image.

Evans, T. E. [Massachusetts Inst. of Technology (M↗

X-ray illuminated stellar winds - Ionization effects in the radiative driving of stellar winds in massive X-ray binary systems

This paper presents calculations of the effect of changing X-ray ionization conditions on the radiative force experienced by the stellar wind material in a massive X-ray binary system. The radiative line force from the radiation field of the primary is parameterized in terms of the Castor et al. (1975) force multiplier. The results show that the line force decreases sharply, but in a nonlinear way, with increasing X-ray ionization. The dynamic consequences of this effect are discussed.

Stevens, Ian R.↗

High-resolution Compton spectroscopy using x-ray microcalorimeters

X-ray Compton spectroscopy is one of the few direct probes of the electron momentum distribution of bulk materials in ambient and operando environments. Herein, we report high-resolution inelastic x-ray scattering experiments with high momentum and energy transfer performed at a storage-ring-based high-energy x-ray light source facility using an x-ray transition-edge sensor (TES) microcalorimeter detector. The performance was compared with a silicon drift detector (SDD), an energy-resolving semiconductor detector, and Compton profiles were measured for lithium and cobalt oxide powders relevant to lithium-ion battery research. Spectroscopic analysis of the measured Compton profiles demonstrates the high-sensitivity to the low- Z elements and oxidation states. The line shape analysis of the measured Compton profiles in comparison with computed Hartree–Fock profiles is usually limited by the resolution of the semiconductor detector. We have characterized an x-ray TES microcalorimeter detector for high-resolution Compton scattering experiments using a bending magnet source at the Advanced Photon Source with a double crystal monochromator, providing monochromatic photon energies near 27.5 keV. The momentum resolution below 0.16 atomic units (a.u.) was measured, yielding an improvement of more than a factor of 7 over a state-of-the-art SDD for the same scattering geometry. Furthermore, the lineshapes of narrow valence and broad core electron profiles of sealed lithium metal were clearly resolved using an x-ray TES compared to smeared and broadened lineshapes observed when using the SDD. High-resolution Compton scattering using the energy-resolving area detector shown here presents new opportunities for spatial imaging of electron momentum distributions for a wide class of materials with applications ranging from electrochemistry to condensed matter physics.

47 OTHER INSTRUMENTATION↗