SEARCH · Search NASA
Results for “accelerated testing”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Accelerated Stress Testing, Qualification Testing, HAST, Field Experience - What Do They All Mean? (Presentation)
This presentation discusses the need for a set of tests for modules that would predict their long term-field performance.
Accelerating Fatigue Testing for Cu Ribbon Interconnects (Presentation)
This presentation describes fatigue experiments and discusses dynamic mechanical loading for Cu ribbon interconnects.
Perfluorinated Sulfonic Acid Membrane and Membrane Electrode Assembly Degradation Correlating Accelerated Stress Testing and Lifetime Testing
Abstract Not Provided
Accelerated Irradiation Testing of Miniature Fuel Specimens
Explore the source record for details and available documents.
Comparison of Accelerated Life Test Plans Based on Exact Small-Sample Methodology and Asymptotic Large-Sample Methodology.
Abstract not provided.
Comparison of Accelerated Life Test Plans Based on Exact Small-Sample Methodology and Asymptotic Large-Sample Methodology.
Abstract not provided.
High-Throughput Optical Mapping for Accelerated Stress Testing of PV Module Materials
The study will provide guidance towards the design and application of larger and/or outdoor-use intended instruments. Measurement capability will be benchmarked against existing specimens, examined in a round-robin study using conventional spectrophotometer instruments. Data acquisition and storage will be integrated into the DuraMAT DataHub network along with data visualization tool, facilitating sharing of information.
A Custom High-Throughput Optical Mapping Instrument (OMI) for Accelerated Stress Testing of PV Module Materials
The performance and integrity of photovoltaic (PV) modules and materials may be assessed through optical characterizations. We have developed a custom Optical Mapping Instrument (OMI) to improve measurement throughput time, facilitate automated measurements, and obtain spatial information relative to commercial benchtop spectrophotometer instruments. Both the key components and the methods used to improve the measurements are described. The measurement precision for the OMI is benchmarked for hemispherical transmittance relative to a previous round-robin study for commercial spectrophotometers. Example mapping measurements and their implications are given for specimens from other studies, including: (1) the depletion of the UV absorber is revealed for specimens beyond a certain size after standardized artificial ultraviolet (UV) weathering, (2) an optical degradation by internal haze formation is confirmed following Damp Heat (85°C/85% relative humidity) testing, (3) the better uniformity of the wear pattern for falling sand abrasion is used to select the DIN 52348 fixture over the ASTM D968 fixture, and (4) the local (millimeter-scale) heterogeneity of surface contamination in the soiling-prone location of Dubai relative to Kuwait. The results of the UV study have already been used to improve the standardized weathering of encapsulants. The example for Damp Heat testing is given to increase awareness of a degradation believed to be ubiquitously occurring in safety and design-type qualification testing of PV modules.
Computational Modeling of Photovoltaic Mini-Modules Undergoing Accelerated Stress Testing.
Abstract not provided.
Computational Modeling of Photovoltaic Mini-Modules Undergoing Accelerated Stress Testing.
Abstract not provided.
Sensor Design Construction and Validation for in-situ Water Layer Thickness Determination during Accelerated Corrosion Testing.
Abstract not provided.
Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing
The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include offline modules, strings, and inverters; system shutdown; arc faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector, and discrete fuse components. Previous papers and presentations have focused on the development of the test method using a benchtop prototype. This presentation covers the early results of C-AST aging of static and dynamic specimens.
Accelerated Corrosion Testing of Cold Spray Coatings on 304L in Chloride Environments.
Abstract not provided.
Accelerated Aging Testing and Emplacement Studies of Dual-Purpose Canister Filler Material
Explore the source record for details and available documents.
Direct Correlation of CdTe Solar Cell Stabiity with Mobile Ion Charge Generation During Accelerated Lifetime Testing: Preprint
CdS/CdTe cells deposited on CTO/ZTO TCO substrates show greater degradation than similar devices fabricated on cSnO2/iSnO2 substrates.