Development and construction of two hydrogen masers Interim technical report, 1 Feb. 1962 - 31 May 1963
Optimal construction of atomic hydrogen frequency standard for spacecraft application
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Optimal construction of atomic hydrogen frequency standard for spacecraft application
Very low temperature atomic hydrogen masers were developed. The advantages over room temperature hydrogen masers include higher radiated power due to the higher beam intensities possible using low temperature techniques and the much smaller electron spin flip cross section at low temperatures, lower cavity and amplifier noise temperatures, increased stability against mechanical creep at low temperatures, and opportunities to extend H atom collision studies to low temperatures, where quantum effects and details of the interatomic potentials are much more important.
Spin-spin interaction energy for large separations of two ground state hydrogen atoms
Atomic hydrogen departures from LTE computed for models of B star atmospheres, assuming detailed balance in hydrogen lines
Total Born cross section determination for fast proton excitation of ground state hydrogen atoms
Determination of rate constants for atomic recombinations involving hydrogen and oxygen
Thermionic emission measurement for palladium filament exposed to molecular and atomic hydrogen beam - hydrogen chemisorption on palladium
This work investigates the effects of argon ions, hydrogen atoms, and hydrogen ions on the diamond (100) surface using classical molecular dynamics simulations. The purpose of this investigation was to asses plasma processing techniques for applications in quantum device manufacturing. The simulations suggest that combining argon ion smoothing with selective, near threshold energy H removal of amorphous C could be an effective strategy for diamond surface engineering, leading to more reliable and sensitive diamond color center devices. Results were found to differ significantly with interatomic potential, and an analysis of these differences was also carried out. Included in this repository are LAMMPS source files, input scripts, and plotting scripts required to reproduce the data. Also included are the output data required to make all the plots included in the associated publication.
Here, the adsorption of atomic H and H 2 on copper mono- and submonolayers supported on hexagonal WC(0001) surfaces has been investigated using density functional theory with the Perdew–Burke–Ernzerhof exchange correlation functional and D2 van der Waals corrections. Results evidence the impact of the termination of the carbide substrate on fundamental properties of Cu adatoms, and, hence, on the stability of molecular and atomic hydrogen, defining copper's catalytic activity for hydrogen evolution reaction. Using H adsorption energy as a descriptor, catalytic activity of Cu adlayers for hydrogen evolution reaction was estimated using traditional volcano curves and a curve, obtained at low hydrogen coverage. Obtained results evidence that copper adlayers supported on the WC may present a viable low-cost alternative to noble metal-based catalysts, with improved catalytic activity compared to that of copper. This, potentially, can be a useful basis for designing and developing novel functional materials with predetermined catalytic properties.
Thermospheric atomic hydrogen concentration temporal variations in situ measurement by Explorer 32 satellite
A low temperature atomic hydrogen maser was developed using frozen atomic neon as the storage surface. The maser has been operated in the pulsed mode at temperatures from 6 K to 11 K and as a self-excited oscillator from 9 K to 10.5 K.
Lateral flow and other effects contributing to the diurnal variation of the amount of atomic hydrogen in the exosphere
Hydrogen atomic beam optics system that increases fraction of atoms entering storage bulb of hydrogen maser
The first year of neutron mapping measurements from the Mars Odyssey spacecraft are presented based on observations from the High Energy Neutron Detector (HEND). The HEND instrument is a part of GRS suite responsible for registration of epithermal and fast neutrons originating in the Mars subsurface layer. The gamma ray and neutron spectrometers measure the scattering of fast neutrons from the Martian surface, which is caused by bombardment of primary cosmic rays and is strongly sensitive to the presence of hydrogen atoms. Even several percent subsurface hydrogen significantly depresses the flux of epithermal and fast neutrons. The recent Mars Odyssey observations detected a considerable amount of hydrogen, almost certainly corresponding to water ice, in the shallow near surface of the southern and northern hemispheres of Mars.
After a preliminary discussion of feasibility, new experimental work with a hydrogen beam is described. A space focused magnetic resonance technique with separated oscillatory fields is used with a monochromatic beam of cold hydrogen atoms which are selected from a higher temperature source. The first resonance curves and other experimental results are presented. These results are interpreted from the point of view of accuracy potential and frequency stability, and are compared with hydrogen maser and cesium beam capabilities.
Stereocontrol is of critical importance in organic synthesis. In this study, we demonstrate how heterogeneous electrochemical hydrogenation enables diastereocontrol simply by tuning electrochemical hydrogenation mechanisms without altering the adsorption conformation of a reactant on the electrode. We use 4-hydroxy-1-tetralone (4-OH-tetralone) as a model reactant, where diastereomers can be produced during the hydrogenation of the carbonyl group. In traditional thermocatalytic hydrogenation, H 2 first dissociates on the catalyst surface to form surface-adsorbed hydrogen (H*), and therefore, H* is always added to the organic reactant from the catalyst side via hydrogen atom transfer (HAT). Thus, in order to flip the diastereoselectivity, the adsorbed reactant itself must be physically flipped. In contrast, electrochemical hydrogenation can occur either via HAT, where H is added from the electrode surface, or via proton-coupled electron transfer (PCET), where H is added from the solution side of the adsorbed reactant. Thus, without changing the adsorption conformation of the reactant, opposite diastereomers can be obtained by switching the hydrogenation mechanism (HAT vs PCET). In this work, using a combination of experimental and computational studies, we demonstrate two examples of flipping diastereoselectivity by different electrochemical hydrogenation mechanisms. In the first case, we achieve opposite diastereoselectivities using metals that adopt different hydrogenation mechanisms (HAT vs PCET). In the second case, we flip the diastereoselectivity by varying the applied potential, which switches one hydrogenation mechanism to the other on the same metal electrode. In each case, our results offer an atomic-level understanding of the preferred hydrogenation mechanism that enables the corresponding diastereoselectivity.
Minimum principle for single channel scattering applied to S-wave elastic-scattering phase shift of positrons by atomic hydrogen
The Polarized Atomic Hydrogen Gas Jet Target polarimeter (HJET) is operated at the Relativistic Heavy Ion Collider (RHIC) since 2004 to measure the absolute polarization of each colliding proton beam. Polarimeter detectors and data acquisition were upgraded in 2015 to increase the solid angle, energy range, and to improve the energy and time resolution. These upgrades along with an improved beam intensity and polarization allowed us to greatly reduce the statistical and systematic errors for the proton polarization measurements in RHIC Runs 15 (E beam = 100 GeV) and 17 (255 GeV). For a typical 8 hour RHIC store, the measured proton beam average polarization was about P beam ~ 55 ± 2.0 stat ± 0.3 syst %. The elastic pp analyzing power, AN(t)~0.04, was determined with a precision of about |δA N (t)|~0.0002 in the momentum transfer squared range 0.001<-t<0.020 GeV 2 . In this paper we present a detailed systematic error analysis of the polarization measurements at HJET. Perspectives of using the HJET based absolute polarimeters in the future Electron Ion Collider (EIC) will be also discussed.