Search NASA⌕ Search

SEARCH · Search NASA

Results for “bragg diffraction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Structural correlations and melting of B-DNA fibers

Despite numerous attempts, understanding the thermal denaturation of DNA is still a challenge due to the lack of structural data on the transition since standard experimental approaches to DNA melting are made in solution and do not provide spatial information. We report a measurement using neutron scattering from oriented DNA fibers to determine the size of the regions that stay in the double-helix conformation as the melting temperature is approached from below. A Bragg peak from the B form of DNA is observed as a function of temperature and its width and integrated intensity are measured. These results, complemented by a differential calorimetry study of the melting of B-DNA fibers as well as electrophoresis and optical observation data, are analyzed in terms of a one-dimensional mesoscopic model of DNA.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thermal Denaturation of DNA Studied with Neutron Scattering

The melting transition of DNA, whereby the strands of the double-helix structure completely separate at a certain temperature, has been characterized using neutron scattering. A Bragg peak from B-form fiber DNA has been measured as a function of temperature, and its widths and integrated intensities have been interpreted using the Peyrard-Bishop-Dauxois model with only one free parameter. The experiment is unique, as it gives spatial correlation along the molecule through the melting transition where other techniques cannot.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Bare Fiber Bragg Gratings embedded into concrete buffer Supercontainer concept for nuclear waste storage

We present the preliminary results obtained with bare fiber Bragg grating-based sensors embedded into half-scale Belgian Supercontainer concept. Being temperature and strain sensitive, some sensors were placed into aluminum tubes to monitor only temperature and results were compared with thermocouples data. The utility of using bare fiber Bragg gratings, knowing that these ones are very fragile, is to have a direct contact between the high alkaline environment of the concrete and silica fibers and to determine its impact over a very long time. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Nucleation and Crystallization of Globular Proteins: What we Know and What is Missing

Recently. much progress has been made in understanding the nucleation and crystallization of globular proteins, including the formation of compositional and structural crystal defects, Insight into the interactions of (screened) protein macro-ions in solution, obtained from light scattering, small angle X-ray scattering and osmotic pressure studies. can guide the search for crystallization conditions. These studies show that the nucleation of globular proteins is governed by the same principles as that of small molecules. However, failure to account for direct and indirect (hydrodynamic) protein interactions in the solutions results in unrealistic aggregation scenarios. Microscopic studies of numerous proteins reveal that crystals grow by the attachment of growth units through the same layer-spreading mechanisms as inorganic crystals. Investigations of the growth kinetics of hen-egg-white lysozyme (HEWL) reveal non-steady behavior under steady external conditions. Long-term variations in growth rates are due to changes in step-originating dislocation groups. Fluctuations on a shorter timescale reflect the non-linear dynamics of layer growth that results from the interplay between interfacial kinetics and bulk transport. Systematic gel electrophoretic analyses suggest that most HEWL crystallization studies have been performed with material containing other proteins at percent levels. Yet, sub-percent levels of protein impurities impede growth step propagation and play a role in the formation of structural/compositional inhomogeneities. In crystal growth from highly purified HEWL solutions, however, such inhomogeneities are much weaker and form only in response to unusually large changes in growth conditions. Equally important for connecting growth conditions to crystal perfection and diffraction resolution are recent advances in structural characterization through high-resolution Bragg reflection profiling and X-ray topography.

Rosenberger, F.↗

Investigation of an unusual low-temperature phase transformation in RbBH{sub 4} by neutron diffraction

To investigate the previously reported low-temperature phase transition in rubidium borohydride (RbBH{sub 4}) near 48.5 K, we carried out neutron powder diffraction and vibrational spectroscopy measurements both above and below this temperature on an isotopically-enriched sample of Rb{sup 11}BD{sub 4}. Our diffraction data reflected an average cubic Fm3{sup ¯}m structure with BD{sub 4}{sup −} anion orientational disorder at all temperatures, with no hint of extra Bragg peaks due to long-range orientational order below the transition temperature as reported by others. These structural results and careful analysis of torsional vibrations in RbBD{sub 4} corroborate the results of prior neutron vibrational spectroscopy measurements suggesting that the low-temperature RbBH{sub 4} structure indeed possesses some orientational ordering of the BH{sub 4}{sup −} anions, but of a shorter-ranged nature insensitive to powder diffraction methods. - The neutron powder diffraction pattern of RbBD{sub 4} below the phase transition temperature (shown here in black) is indistinguishable from that collected above the phase transition temperature. The inset depicts the cubic structure that fits the data at both temperatures. - Highlights: • We investigated the nature of the RbBD{sub 4} phase transition using NVS and NPD. • A change in shape of the RbBD{sub 4} torsion mode was observed across the transition. • The RbBD{sub 4} diffraction pattern across this phase transition was unchanged. • The phase transition in RbBD{sub 4} appears to produce only short-range ordering of BD{sub 4}{sup −}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Normalization schemes for ultrafast x-ray diffraction using a table-top laser-driven plasma source

We present an experimental setup of a laser-driven x-ray plasma source for femtosecond x-ray diffraction. Different normalization schemes accounting for x-ray source intensity fluctuations are discussed in detail. We apply these schemes to measure the temporal evolution of Bragg peak intensities of perovskite superlattices after ultrafast laser excitation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multibeam Electron Diffraction

One of the primary uses for transmission electron microscopy (TEM) is to measure diffraction pattern images in order to determine a crystal structure and orientation. In nanobeam electron diffraction (NBED), we scan a moderately converged electron probe over the sample to acquire thousands or even millions of sequential diffraction images, a technique that is especially appropriate for polycrystalline samples. However, due to the large Ewald sphere of TEM, excitation of Bragg peaks can be extremely sensitive to sample tilt, varying strongly for even a few degrees of sample tilt for crystalline samples. In this paper, we present multibeam electron diffraction (MBED), where multiple probe-forming apertures are used to create multiple scanning transmission electron microscopy (STEM) probes, all of which interact with the sample simultaneously. We detail designs for MBED experiments, and a method for using a focused ion beam to produce MBED apertures. We show the efficacy of the MBED technique for crystalline orientation mapping using both simulations and proof-of-principle experiments. We also show how the angular information in MBED can be used to perform 3D tomographic reconstruction of samples without needing to tilt or scan the sample multiple times. Finally, we also discuss future opportunities for the MBED method.

47 OTHER INSTRUMENTATION↗

Non-conventional bell-shaped diffuse scattering in low-energy electron diffraction from high-quality epitaxial 2D-materials

A broad, bell-shaped intensity component is observed in low-energy electron diffraction from high-quality epitaxial 2D-systems. Three 2D-systems, graphene on Ir(111), graphene on SiC(0001), and hexagonal boron nitride on Ir(111), have been prepared in situ under ultra-high vacuum conditions. In all three systems—independent of substrate material—similar strong diffuse intensity is observed, exhibiting a width as large as 50% of the Brillouin zone and an integrated intensity more than 10 times the intensity of the Bragg spots. The presented experimental results provide evidence for a common origin of such diffuse diffraction intensity in different atomically thin 2D-materials.

Omambac, K. (ORCID:0000000250139567)↗

Layered synthetic microstructures as Bragg diffractors for X rays and extreme ultraviolet - Theory and predicted performance

The theory of X-ray diffraction by periodic structures is applied to the layered synthetic microstructures (LSMs) made possible by recent developments in thin film technology, and approximate formulas for estimating their performance are presented. A more complete computation scheme based on optical multilayer theory is also described, and it is shown that the diffracting properties may be tailored to specific applications by adjusting the refractive indices and thicknesses of the component layers. The theory may be modified to take account of imperfections in the LMS structure, and the properties of nonperiodic structures thereby computed. Structures with high integrated reflectivity constructed according to the methods defined have potential application in many areas of X-ray or EUV research and instrumentation.

Underwood, J. H.↗

Serial femtosecond X-ray diffraction of enveloped virus microcrystals

Serial femtosecond crystallography (SFX) using X-ray free-electron lasers has produced high-resolution, room temperature, time-resolved protein structures. We report preliminary SFX of Sindbis virus, an enveloped icosahedral RNA virus with ~700 Å diameter. Microcrystals delivered in viscous agarose medium diffracted to ~40 Å resolution. Small-angle diffuse X-ray scattering overlaid Bragg peaks and analysis suggests this results from molecular transforms of individual particles. Viral proteins undergo structural changes during entry and infection, which could, in principle, be studied with SFX. This is a pertinent step toward determining room temperature structures from virus microcrystals that may enable time-resolved studies of enveloped viruses.

59 BASIC BIOLOGICAL SCIENCES↗

Single-shot mega-electronvolt ultrafast electron diffraction for structure dynamic studies of warm dense matter

We have developed a single-shot mega-electronvolt ultrafast-electron-diffraction system to measure the structural dynamics of warm dense matter. The electron probe in this system is featured by a kinetic energy of 3.2 MeV and a total charge of 20 fC, with the FWHM pulse duration and spot size at sample of 350 fs and 120 μm respectively. We demonstrate its unique capability by visualizing the atomic structural changes of warm dense gold formed from a laser-excited 35-nm freestanding single-crystal gold foil. The temporal evolution of the Bragg peak intensity and of the liquid signal during solid-liquid phase transition are quantitatively determined. This experimental capability opens up an exciting opportunity to unravel the atomic dynamics of structural phase transitions in warm dense matter regime.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Confocal Microscope Alignment of Nanocrystals for Coherent Diffraction Imaging

We have installed and tested an Olympus LEXT confocal microscope at the 34-ID-C beamline of the Advanced Photon Source (APS). The beamline is for Coherent X-ray Diffraction (CXD) experiments in which a nanometre-sized crystal is aligned inside a focussed X-ray beam. The microscope was required for three-dimensional (3D) sample alignment to get around sphere-of-confusion issues when locating Bragg peaks in reciprocal space. In this way, and by use of strategic sample preparations, we have succeeded in measuring six Bragg peaks from a single 200 nm gold crystal and obtained six projections of its internal displacement field. This enables the clear identification of stacking-fault bands within the crystal. The confocal alignment method will allow a full determination of the strain tensor provided three or more Bragg reflections from the same crystal are found.

43 PARTICLE ACCELERATORS↗

Grazing-incidence X-ray diffraction from a crystal with subsurface defects

The diffraction of X rays incident on a crystal surface under grazing angles under conditions of total external reflection has been investigated. An approach is proposed in which exact solutions to the dynamic problem of grazing-incidence diffraction in an ideal crystal are used as initial functions to calculate the diffuse component of diffraction in a crystal with defects. The diffuse component of diffraction is calculated for a crystal with surface defects of a dilatation-center type. Exact formulas of the continuum theory which take into account the mirror-image forces are used for defect-induced atomic displacements. Scattering intensity maps near Bragg peaks are constructed for different scan modes, and the conditions for detecting primarily the diffuse component are determined. The results of dynamic calculations of grazing-incidence diffraction in defect-containing crystals are compared with calculations in the kinematic approximation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Diffraction imaging for in situ characterization of double-crystal X-ray monochromators

Imaging of the Bragg-reflected X-ray beam is proposed and validated as an in situ method for characterization of the performance of double-crystal monochromators under the heat load of intense synchrotron radiation. A sequence of images is collected at different angular positions on the reflectivity curve of the second crystal and analyzed. The method provides rapid evaluation of the wavefront of the exit beam, which relates to local misorientation of the crystal planes along the beam footprint on the thermally distorted first crystal. The measured misorientation can be directly compared with the results of finite element analysis. The imaging method offers an additional insight into the local intrinsic crystal quality over the footprint of the incident X-ray beam.

cryogenic cooling↗

SrFe{sub 0.9}Ti{sub 0.1}O{sub 3−δ}: A cluster spin glass

Graphical abstract: - Highlights: • Prepared SrFe{sub 0.9}Ti{sub 0.1}O{sub 3−δ} is in nanocrystalline form. • Arrott plot shows absence of spontaneous magnetization which rules out the possibility of long range ferromagnetic order. • AC susceptibility data is evidence of cluster spin glass. • There is no magnetic Bragg's reflection. • By substituting Ti{sup 4+}, helical antiferromagetic SrFeO{sub 3} is transformed to a cluster spin glass. - Abstract: The magnetic ground state of nanocrystalline SrFe{sub 0.9}Ti{sub 0.1}O{sub 3−δ} system has been investigated from 2 K to 300 K using AC Susceptibilty (ACS), magnetization and neutron diffraction measurements. The cusp in the temperature dependent magnetization and dispersion below T{sub max} (the temperature at which the maximum susceptibility is observed) in real part of ac susceptibility with frequency is observed. Arrott plot shows the lack of M{sub S} (spontaneous magnetization) down to 2 K, and the non-occurrence of magnetic Bragg reflections below the T{sub max} in neutron diffraction measurements, indicates the absence of long range ferro and antiferromagnetic order. The frequency dependence of T{sub max} obeys Vögel–Fulcher model establishing the cluster spin glass behavior in this system.

36 MATERIALS SCIENCE↗

High-precision laser-assisted absolute determination of x-ray diffraction angles

A novel technique for absolute wavelength determination in high-precision crystal x-ray spectroscopy recently introduced has been upgraded reaching unprecedented accuracies. The method combines visible laser beams with the Bond method, where Bragg angles ({theta} and -{theta}) are determined without any x-ray reference lines. Using flat crystals this technique makes absolute x-ray wavelength measurements feasible even at low x-ray fluxes. The upgraded spectrometer has been used in combination with first experiments on the 1s2p {sup 1}P{sub 1}{yields} 1s{sup 2} {sup 1}S{sub 0} w-line in He-like argon. By resolving a minute curvature of the x-ray lines the accuracy reaches there the best ever reported value of 1.5 ppm. The result is sensitive to predicted second-order QED contributions at the level of two-electron screening and two-photon radiative diagrams and will allow for the first time to benchmark predicted binding energies for He-like ions at this level of precision.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evolution of deformation structures under varying loading conditions followed in-situ by high angular resolution 3DXRD.

With high angular resolution three-dimensional X-ray diffraction, individual subgrains are traced in the bulk of a polycrystalline specimen and their dynamics is followed in situ during varying loading conditions. The intensity distribution of single Bragg reflections from an individual grain is analyzed in reciprocal space. It consists of sharp high-intensity peaks arising from subgrains superimposed on a cloud of lower intensity arising from dislocation walls. Individual subgrains can be distinguished by their unique combination of orientation and elastic strain. The responses of polycrystalline copper to different loading conditions are presented: during uninterrupted tensile deformation, formation of subgrains can be observed concurrently with broadening of the Bragg reflection shortly after onset of plastic deformation. With continued tensile deformation, the subgrain structure develops intermittently. When the traction is terminated, stress relaxation occurs and number, size and orientation of subgrains are found to be constant. The subgrain structure freezes and only a minor clean-up of the dislocation structure is observed. When changing the tensile direction after pre-deformation in tension, a systematic correlation between the degree of strain path change and the changes in the dislocation structure quantified by the volume fraction of the subgrains is established. For obtaining the subgrain volume fraction, a new fitting method has been developed for partitioning the contributions of subgrains and dislocation walls.

36 MATERIALS SCIENCE↗

Magnetic Order in TbCo2Zn20 and TbFe2Zn20

We report neutron di raction studies of TbCo2Zn20 and TbFe2Zn20, two isostructural compounds which exhibit dramatically di erent magnetic behavior. In the case of TbCo2Zn20, magnetic Bragg peaks corresponding to antiferromagnetic order are observed below TN 2.5 K with a propagation vector of (0.5 0.5 0.5). On the other hand, TbFe2Zn20 undergoes a ferromagnetic transition at temperatures as high as 66 K which shows a high sensitivity to sample-to-sample variations. Two samples of TbFe2Zn20 with the same nominal compositions but with substantially di erent mag- netic ordering temperatures (Tc 51 and 66 K) were measured by single crystal neutron di raction. Structural re nements of the neutron di raction data nd no direct signature of atomic site disorder between the two TbFe2Zn20 samples except for subtle di erences in the anisotropic thermal param- eters. The di erences in the anisotropic thermal parameters between the two samples is likely due to very small amounts of disorder. This provides further evidence for the extreme sensitivity of the magnetic properties of TbFe2Zn20 to small sample variations, even small amounts of disorder.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗