Search NASA⌕ Search

SEARCH · Search NASA

Results for “building case study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Technology Solutions Case Study: Cladding Attachment Over Mineral Fiber Insulation Board

Exterior insulating sheathing for high performance building enclosures is an important strategy for meeting energy efficiency requirements in many climates and can position an existing building to perform at the level of best-in-class new construction. Insulation board is also important in high performance building retrofit situations where minimal disruption at the interior is typically desired.

BSC↗

Technology Solutions Case Study: Hygrothermal Performance of a Double-Stud Cellulose Wall

Moisture problems within the building shell can be caused by a number of factors including excess interior moisture that is transported into the wall through air leakage and vapor drive, bulk water intrusion from leaks and wind-driven rain, capillary action from concrete to wood connections, and through wetted building materials such as siding wetted from rain splash back. With the increasing thickness of walls, moisture issues could increase. Several builders have successfully used “double-wall” systems to more practically achieve higher R-values in thicker framed walls. A double wall typically consists of a load-bearing external frame wall constructed with 2 × 4 framing at 16 in. on center using conventional methods. After the building is enclosed, an additional frame wall is constructed several inches inside the load-bearing wall. Several researchers have used moisture modeling software to conduct extensive analysis of these assemblies; however, little field research has been conducted to validate the results. In this project, the Building America research team Consortium for Advanced Residential Buildings monitored a double-stud assembly in climate zone 5A to determine the accu¬racy of moisture modeling and make recommendations to ensure durable and efficient assemblies.

Building America↗

Measured Zero Net Energy Performance: Results, Lessons, and Surprises

As more and more zero net energy (ZNE) buildings are built and monitored, we can learn from both careful case studies of individual projects as well as a broader perspective of trends over time. In a forum sponsored by Pacific Gas and Electric Company (PG&E), eight expert speakers discussed: results and lessons from monitoring occupied ZNE buildings; best practices for setting performance targets and getting actionable performance information, and; things that have surprised them about monitored ZNE buildings. This paper distills the content of the forum by laying out the most common hurdles that are encountered in setting up monitoring projects, frequent performance issues that the monitoring uncovers, and lessons learned that can be applied to future projects.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Human Missions to Europa and Titan - Why Not?

This report describes a long-term development plan to enable human exploration of the outer solar system, with a focus on Europa and Titan. These are two of the most interesting moons of Jupiter and Saturn, respectively, because they are the places in the solar system with the greatest potential for harboring extraterrestrial life. Since human expeditions to these worlds are considered impossible with current capabilities, the proposal of a well-organized sequence of steps towards making this a reality was formulated. The proposed Development Plan, entitled Theseus, is the outcome of a recent multinational study by a group of students in the framework of the Master of Space Studies (MSS) 2004 course at the International Space University (ISU). The Theseus Program includes the necessary development strategies in key scientific and technological areas that are essential for identifying the requirements for the exploration of the outer planetary moons. Some of the topics that are analysed throughout the plan include: scientific observations at Europa and Titan, advanced propulsion and nuclear power systems, in-situ resource utilization, radiation mitigation techniques, closed life support systems, habitation for long-term spaceflight, and artificial gravity. In addition to the scientific and technological aspects of the Theseus Program, it was recognized that before any research and development work may begin, some level of program management must be established. Within this chapter, legal issues, national and international policy, motivation, organization and management, economic considerations, outreach, education, ethics, and social implications are all considered with respect to four possible future scenarios which enable human missions to the outer solar system. The final chapter of the report builds upon the foundations set by Theseus through a case study. This study illustrates how such accomplishments could influence a mission to Europa to search for evidence of life in its subsurface oceans. The future remains unpredictable, as does the realization of any of these possibilities. However, projects such as this remind us that the final frontier for humans is truly outer space, and only our imagination will determine where the frontier stops. We can dream of visiting other planetary systems and perhaps even galaxies, but we must begin closer, and considering the scope of our known universe, Europa and Titan are very close indeed.

FROM↗

Colorado Better Buildings Project. Final Report

The Colorado Better Buildings project intended to bring new and existing energy efficiency model programs to market with regional collaboration and funding partnerships. The goals for Boulder County and its program partners were to advance energy efficiency investments, stimulate economic growth in Colorado and advance the state’s energy independence. Collectively, three counties set out to complete 9,025 energy efficiency upgrades in 2.5 years and they succeeded in doing so. Energy efficiency upgrades have been completed in more than 11,000 homes and businesses in these communities. Boulder County and its partners received a $25 million BetterBuildings grant from the U.S. Department of Energy under the American Recovery and Reinvestment Act in the summer of 2010. This was also known as the Energy Efficiency and Conservation Block Grants program. With this funding, Boulder County, the City and County of Denver, and Garfield County set out to design programs for the residential and commercial sectors to overcome key barriers in the energy upgrade process. Since January 2011, these communities have paired homeowners and business owners with an Energy Advisor – an expert to help move from assessment to upgrade with minimal hassle. Pairing this step-by-step assistance with financing incentives has effectively addressed many key barriers, resulting in energy efficiency improvements and happy customers. An expert energy advisor guides the building owner through every step of the process, coordinating the energy assessment, interpreting results for a customized action plan, providing a list of contractors, and finding and applying for all available rebates and low-interest loans. In addition to the expert advising and financial incentives, the programs also included elements of social marketing, technical assistance, workforce development and contractor trainings, project monitoring and verification, and a cloud-based customer data system to coordinate among field advisors and across local governments and local service vendors. A portion of the BetterBuildings grant went to the Metro Mayors Caucus (MMC) who worked in partnership with the Denver Regional Council of Governments (DRCOG) to conduct a series of 10 energy efficiency workshops for local government officials and other interested parties. The workshops helped showcase lessons learned on energy efficiency and helped guide other local governments in the establishment of similar programs. The workshops covered a wide range of energy efficiency and renewable energy topics such as clean energy finance, social mobilization and communications, specific case studies of Colorado towns, energy efficiency codes, net zero buildings and solar power. Since the programs launched in January 2011, these communities have collectively spurred economic investments in energy efficiency, achieved greater than 5:1 leveraging of grant funds, saved energy and reduced greenhouse gas emissions, provided trainings for a robust local energy contractor network, and proved out viable and replicable program models that local utilities and other communities are adopting, with long lasting market transformation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Framework for Small-Scale Experiments in Software Engineering: Guidance and Control Software Project: Software Engineering Case Study

Software is becoming increasingly significant in today's critical avionics systems. To achieve safe, reliable software, government regulatory agencies such as the Federal Aviation Administration (FAA) and the Department of Defense mandate the use of certain software development methods. However, little scientific evidence exists to show a correlation between software development methods and product quality. Given this lack of evidence, a series of experiments has been conducted to understand why and how software fails. The Guidance and Control Software (GCS) project is the latest in this series. The GCS project is a case study of the Requirements and Technical Concepts for Aviation RTCA/DO-178B guidelines, Software Considerations in Airborne Systems and Equipment Certification. All civil transport airframe and equipment vendors are expected to comply with these guidelines in building systems to be certified by the FAA for use in commercial aircraft. For the case study, two implementations of a guidance and control application were developed to comply with the DO-178B guidelines for Level A (critical) software. The development included the requirements, design, coding, verification, configuration management, and quality assurance processes. This paper discusses the details of the GCS project and presents the results of the case study.

Hayhurst, Kelly J.↗

Transmission Planning with Renewable Energy Zones (REZ): Overview, Select Case Studies, and Key Enablers

The renewable energy zone (REZ) transmission planning process is a proactive method to plan, approve, and build transmission infrastructure that connects high-quality and large-scale renewable resources to the power system. This presentation was developed for a technical side event focused on transmission systems to facilitate the rapid decarbonization of power systems at the Clean Energy Ministerial Senior Officials Meeting in March 2023. This document contains a synthesis of key REZ case studies throughout the world and is intended as a resource for policymakers and energy planners.

Australia↗

Advances in supervisory control strategies for a heat pump centric HVAC system − a comprehensive review on applications

There is an increase in research investigating the development and deployment of supervisory controllers that enable high efficiency electrically driven vapor compression heat pumps operating within grid interactive efficient buildings to provide demand side management. This paper reviews over sixty relevant case studies within this domain that focus on commercial off-the-shelf heat pumps whose primary task is providing space conditioning. The concept of a heat pump-centric heating, ventilation, and air-conditioning system is introduced, accompanied by a detailed overview of various kinds of electric heat pumps and building-level thermal energy storage configurations. Additionally, the different types of supervisory controller designs, including rule-based control and model predictive control, are discussed, along with the various methods for communication between a supervisory controller and a downstream heat pump’s local controller. A comparative analysis is conducted in order to categorize the reviewed case studies based on their system design, supervisory control algorithm, and validation methodology. This detailed analysis allows the review to establish current research trends, identify potential gaps, and suggest future directions for the development of this technology. Overall, the authors recommend that more future research be devoted to low-cost practical retrofits that allow for easy integration of active thermal energy storage within heat pump-centric heating, ventilation, and air-conditioning system systems that utilize direct expansion heat pumps. We also suggest more research into the development and deployment of supervisory controllers that can properly communicate with commercial off-the-shelf heat pump local controller available control inputs, e.g., zone temperature setpoint. Lastly, more rigorous experimental demonstrations of advanced supervisory control within real and or closed-loop, transient/ quasi-steady state environments are necessary to reduce industry wide skepticism of this technology.

Demand side management↗

Earthquake response of storey building in Jakarta using accelerographs data analysis

As seismotectonic, the Jakarta city will be greatly affected by the earthquake which originated from the subduction zone of the Sunda Strait and south of Java. Some occurrences of earthquakes in these location are often perceived by the occupants in the upper floors of multi-storey buildings in Jakarta but was not perceived by the occupants on the ground floor. The case shows the difference in ground-motion parameters on each floor height. The analysis of the earthquake data recorded by accelerographs on different floors need to be done to know the differences in ground-motion parameters. Data used in this research is accelerograph data installed on several floors in the main building of Meteorology Climatology and Geophysics Agency with a case study of Kebumen earthquake on January 25{sup th} 2014. Parameters analyzed include the Peak Ground Acceleration (PGA), Peak Ground Displacement (PGD), Peak Spectral Acceleration (PSA), Amplification (Ag), and the Effective Duration of earthquake (t{sub e}). Research stages include accelerographs data acquisition in three (3) different floors, conversion and data partition for each component, conversion to units of acceleration, determination of PGA, PGD, PSA, Ag and t{sub e} as well as data analysis. The study shows the value of PGA on the ground floor, 7{sup th} floor and 15{sup th} floors, respectively are 0.016 g, 0.053 g and 0.116 g. PGD on the ground floor, 7{sup th} floor and 15{sup th} floor respectively are 2.15 cm, 2.98 cm and 4.92 cm. PSA on the ground floor, 7{sup th} floor and 15{sup th} floor respectively are 0.067 g, 0.308 g and 0.836 g. Amplification of the peak acceleration value on the ground floor, 7{sup th} floor and 15{sup th} floor to the surface rock are 4.37, 6.07 and 7.30. Effective duration of the earthquake on the ground floor, 7{sup th} floor and 15{sup th} floor respectively are 222.28 s, 202.28 s and 91.58 s. In general, with increasing floor of the building, the value of the peak ground acceleration, peak ground displacement, peak spectral acceleration and amplification growing, contrary to the value of the effective duration of earthquake decreases. The difference in this parameter is strongly influenced by local soil conditions and building construction.

58 GEOSCIENCES↗

Policies to Spur Energy Access. Executive Summary; Volume 1, Engaging the Private Sector in Expanding Access to Electricity; Volume 2, Case Studies to Public-Private Models to Finance Decentralized Electricity Access

Government policy is one of the most important factors in engaging the private sector in providing universal access to electricity. In particular, the private sector is well positioned to provide decentralized electricity products and services. While policy uncertainty and regulatory barriers can keep enterprises and investors from engaging in the market, targeted policies can create opportunities to leverage private investment and skills to expand electricity access. However, creating a sustainable market requires policies beyond traditional electricity regulation. The report reviews the range of policy issues that impact the development and expansion of a market for decentralized electricity services from establishing an enabling policy environment to catalyzing finance, building human capacity, and integrating energy access with development programs. The case studies in this report show that robust policy frameworks--addressing a wide range of market issues--can lead to rapid transformation in energy access. The report highlights examples of these policies in action Bangladesh, Ethiopia, Mali, Mexico, and Nepal.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Advanced Metering Implementations - A Perspective from Federal Sector

Federal mandate (EPACT 2005) requires that federal buildings install advanced electrical meters-meters capable of providing data at least daily and measuring the consumption of electricity at least hourly. This work presents selected advanced metering implementations to understand some of the existing practices related to data capture and to understand how the data is being translated into information and knowledge that can be used to improve building energy and operational performance to meet federal energy reduction mandates. This study highlights case studies to represent some of the various actions that are being taken based on the data that are being collected to improve overall energy performance of these buildings. Some of these actions include- individualized tenant billing and energy forecasting, benchmarking, identifying energy conservation measures, measurement and verification.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Equation-based object-oriented modeling and simulation for data center cooling: A case study

© 2019 Elsevier B.V. Data center cooling accounts for about 1% of electricity usage in the United States. Computer models are pivotal in designing and operating energy-efficient cooling systems. Compared to conventional building performance simulation programs, the equation-based object-oriented modeling language Modelica is an emerging approach that can enable fast prototyping and dynamic simulation of cooling systems. In this case study, we first modeled the cooling and control systems of an actual data center located in Massachusetts using the open-source Modelica Buildings library, and then calibrated a baseline model based on measurement data. The simulation of the baseline model identified several operation-related issues in the cooling and control systems, such as degraded cooling coils, improper dead band in control settings, and simultaneous cooling and heating in air handlers. Afterwards, we used a sequential search technique as well as an optimization scheme to investigate the energy saving potentials for different energy efficiency measures aiming to address the abovementioned issues. Simulation results show potential energy savings up to 24% by resolving identified control-related issues and optimizing the supply air temperature.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ice processes in Antarctica: identification via multi-wavelength active and passive measurements and model evaluation (Final Report)

This project is based on new multi-frequency radar observations collected during the AWARE field campaign in 2016 at McMurdo Station by the ARM Mobile facility. Three scientific goals have been achieved. We have developed ice and mixed-phase cloud microphysics retrievals from multi-wavelength radar observations and ancillary observations, generally applicable at ARM sites. These technique generally better characterize the size of the ice crystals, their equivalent water content and the degree of riming better than using single wavelength techniques. We have characterized ice microphysical properties and ice processes via multi-frequency signatures. We have identified a unique mode in the McMurdo dataset appearing at quite cold temperature that we have attributed to riming processes. Triple frequency radar measurements unfortunately were available only for a short period but our work lays the foundation for building climatological and testing their replicability in models. Simultaneously case studies from the AWARE campaign have been exploited to evaluate and improve the NASA GISS ModelE3 climate model, including selection of case studies for combined goals of (i) running side-by-side using large-eddy simulation (LES) and ModelE3 in single-column model (SCM) mode and (ii) fingerprinting cloud processes in multi-wavelength radar observations. The different components of this work have contributed to 15 published papers with two currently under review.

54 ENVIRONMENTAL SCIENCES↗

2006/07 Field Testing of Cellulose Fiber Insulation Enhanced with Phase Change Material

Most recent improvements in building envelope technologies suggest that in the near future, residences will be routinely constructed to operate with very low heating and cooling loads. In that light, the application of novel building materials containing active thermal components (e.g., phase change materials [PCMs,] sub-venting, radiant barriers, and integrated hydronic systems) is like a final step in achieving relatively significant heating and cooling energy savings from technological improvements in the building envelope. It is expected that optimized building envelope designs using PCMs for energy storage can effectively bring notable savings in energy consumption and reductions in peak hour power loads. During 2006/07, a research team at Oak Ridge National Laboratory (ORNL) performed a series of laboratory and field tests of several wall and roof assemblies using PCM-enhanced cellulose insulation. This report summarizes the test results from the perspective of energy performance. The ORNL team is working on both inorganic and organic PCMs; this report discusses only paraffinic PCMs. A limited economical analysis also is presented. PCMs have been tested as a thermal mass component in buildings for at least 40 years. Most of the research studies found that PCMs enhanced building energy performance. In the case of the application of organic PCMs, problems such as high initial cost and PCM leaking (surface sweating) have hampered widespread adoption. Paraffinic hydrocarbon PCMs generally performed well, with the exception that they increased the flammability of the building envelope.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Investigation of Energy Efficient Retrofit HVAC Systems for a University: Case Study

We did energy efficient retrofits for the Indiana University Purdue University—Indianapolis Health Science Building using the eQuest energy software. The current dual-fan dual-duct (DFDD) system is 41 years old and has a higher energy utilization index (EUI) than the national average for similar building types. The baseline model with the DFDD system was compared with the actual electrical consumption. Then, two energy efficiency measures (EEMs) were applied to the model. The first EEM was ‘DFDD system with chilled water and steam heating,’ and the second EEM was ‘single-duct variable air volume (VAV) with chilled water and electric reheat.’ After comparative simulations and analyses, it was determined that the ‘single duct VAV with chilled water and electric reheat’ was the most energy efficient and saved 28% in utility costs. The recommendation given to the facility services was to change the current DFDD system to the single-duct VAV system. The single-duct VAV system will save energy and create additional space above the ceiling after the heating duct is removed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗