Search NASA⌕ Search

SEARCH · Search NASA

Results for “camera response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

DUST DISTRIBUTION IN THE beta PICTORIS CIRCUMSTELLAR DISKS

We present three-dimensional models of dust distribution around beta Pictoris that produce the best fits to the Hubble Space Telescope/Advanced Camera for Surveys' images obtained by Golimowski and coworkers. We allow for the presence of either one or two separate axisymmetric dust disks. The density models are analytical, radial two power laws joined smoothly at a crossover radius with density exponentially decreasing away from the midplane of the disks. Two-disk models match the data best, yielding a reduced chi{sup 2} of approx1.2. Our two-disk model reproduces many of the asymmetries reported in the literature and suggests that it is the secondary (tilted) disk which is largely responsible for them. Our model suggests that the secondary disk is not constrained to the inner regions of the system (extending out to at least 250 AU) and that it has a slightly larger total area of dust than the primary, as a result of slower falloff of density with radius and height. This surprising result raises many questions about the origin and dynamics of such a pair of disks. The disks overlap, but can coexist owing to their low optical depths and therefore long mean collision times. We find that the two disks have dust replenishment times on the order of 10{sup 4} yr at approx100 AU, hinting at the presence of planetesimals that are responsible for the production of second generation dust. A plausible conjecture, which needs to be confirmed by physical modeling of the collisional dynamics of bodies in the disks, is that the two observed disks are derived from underlying planetesimal disks; such disks would be anchored by the gravitational influence of planets located at less than 70 AU from beta Pic that are themselves in slightly inclined orbits.

79 ASTRONOMY AND ASTROPHYSICS↗

Response of a matrix photodetector into components of an optical signal with different spatial frequencies

We have used the method of direct evaluation of energy incident on each pixel of a photosensitive array to assess the distortions of a matrix photodetector response into a sinusoidal spatial signal. Using the data obtained, we have formulated recommendations for selecting a resolution of a matrix photodetector as a function of a maximum spatial frequency in the recorded interference pattern, as well as for matching of the resolutions of an objective and a photodetector of a digital camera or camcorder. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mass spectrometer-pyrolysis experiment for atmospheric and soil sample analysis on the surface of Mars

Results from the Viking mission will form the foundation for future in-depth investigations of atmosphere-surface interactions on Mars. The two Viking landers carried impressive instrumentation to obtain and analyze soil samples: the sites were observed by cameras, and the collector head was located on a long boom and allowed the collection of large samples at various depths. A selection of grain sizes was possible and a distribution system supplied a number of experiments with soil material. Despite stationary vehicles, a wide sampling field was reachable. The GCMS system, responsible for atmospheric as well as surface soil analysis, worked well on both landers. Atmospheric measurements resulted in the determination of the abundance of noble gases as well as of other molecular species. Isotopic composition measurements included the important ratios of C-13/C-12, N-15/N-14, and Ar-36/Ar-40. To verify these past results and to advance detailed studies of noble gas isotope ratios and minor constituents, better instrument sensitivities, higher precision, and lower background contributions are required in future Mars missions. Soil analysis during the Viking mission concentrated on organic material. Heating cycles were performed to 500 C and only water and carbon dioxide were identified. Higher pyrolysis temperatures are of primary importance to advance our understanding of the mineralogy and gas loading of surface material and atmospheric exchange.

Mauersberger, Konrad↗

In-Vacuum Photogrammetry of a Ten-Meter Square Solar Sail

Solar sailing is a promising, future in-space propulsion method that uses the small force of reflecting sunlight to accelerate a large, reflective membrane without expendable propellants. One of two solar sail configurations under development by NASA is a striped net approach by L'Garde, Inc. This design uses four inflatably deployed, lightweight booms supporting a network of thin strings onto which four quadrants of ultrathin aluminized membranes are attached. The NASA Langley Research Center (LaRC) provided both experimental and analytical support to L'Garde for validating the structural characteristics of this unique, ultralightweight spacecraft concept. One of LaRC's responsibilities was to develop and apply photogrammetric methods to measure sail shape. The deployed shape provides important information for validating the accuracy of finite-element modeling techniques. Photogrammetry is the science and art of calculating 3D coordinates of targets or other distinguishing features on structures using images. A minimum of two camera views of each target is required for 3D determination, but having four or more camera views is preferable for improved reliability and accuracy. Using retroreflective circular targets typically provides the highest measurement accuracy and automation. References 3 and 4 provide details of photogrammetry technology, and reference 5 discusses previous experiences with photogrammetry for measuring gossamer spacecraft structures such as solar sails. This paper discusses the experimental techniques used to measure a L Garde 10-m solar sail test in vacuum with photogrammetry. The test was conducted at the NASA-Glenn Space Power Facility (SPF) located at Plum Brook Station in Sandusky, Ohio. The SPF is the largest vacuum chamber in the United States, measuring 30 m in diameter by 37 m in height. High vacuum levels (10(exp -6) torr) can be maintained inside the chamber, and cold environments (-195 C) are possible using variable-geometry cryogenic cold walls. This test used a vacuum level of approximately 1 torr (sufficient for structural static/dynamic characterization) and instead of using the cryogenic cold walls, used local LN2 cold plates underneath each of the four cold-rigidizable solar sail booms instead.

Pappa, Richard S.↗

Micrometeoroid Impacts on the Hubble Space Telescope Wide Field and Planetary Camera 2: Smaller Particle Impacts

The radiator shield on the Wide Field and Planetary Camera 2 (WFPC2) was subject to optical inspection following return from the Hubble Space Telescope (HST) in 2009. The survey revealed over 600 impact features of > 300 micrometers diameter, from exposure in space for 16 years. Subsequently, an international collaborative programme of analysis was organized to determine the origin of hypervelocity particles responsible for the damage. Here we describe examples of the numerous smaller micrometeoroid (MM) impact features (< 700 micrometers diameter) which excavated zinc orthotitanate (ZOT) paint from the radiator surface, but did not incorporate material from underlying Al alloy; larger impacts are described by [3]. We discuss recognition and interpretation of impactor remains, and MM compositions found on WFPC2.

Ross, D. K.↗

THE ROLE OF QUENCHING TIME IN THE EVOLUTION OF THE MASS–SIZE RELATION OF PASSIVE GALAXIES FROM THE WISP SURVEY

We analyze how passive galaxies at z ∼ 1.5 populate the mass–size plane as a function of their stellar age, to understand if the observed size growth with time can be explained with the appearance of larger quenched galaxies at lower redshift. We use a sample of 32 passive galaxies extracted from the Wide Field Camera 3 Infrared Spectroscopic Parallel (WISP) survey with spectroscopic redshift 1.3 ≲ z ≲ 2.05, specific star formation rates lower than 0.01 Gyr{sup −1}, and stellar masses above 4.5 × 10{sup 10} M {sub ⊙}. All galaxies have spectrally determined stellar ages from fitting of their rest-frame optical spectra and photometry with stellar population models. When dividing our sample into young (age ≤2.1 Gyr) and old (age >2.1 Gyr) galaxies we do not find a significant trend in the distributions of the difference between the observed radius and that predicted by the mass–size relation. This result indicates that the relation between the galaxy age and its distance from the mass–size relation, if it exists, is rather shallow, with a slope α ≳ −0.6. At face value, this finding suggests that multiple dry and/or wet minor mergers, rather than the appearance of newly quenched galaxies, are mainly responsible for the observed time evolution of the mass–size relation in passive galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

Explorer-II: Wireless Self-Powered Visual and NDE Robotic Inspection System for Live Gas Distribution Mains

Carnegie Mellon University (CMU) under contract from Department of Energy/National Energy Technology Laboratory (DoE/NETL) and co-funding from the Northeast Gas Association (NGA), has completed the overall system design, field-trial and Magnetic Flux Leakage (MFL) sensor evaluation program for the next-generation Explorer-II (X-II) live gas main Non-destructive Evaluation (NDE) and visual inspection robot platform. The design is based on the Explorer-I prototype which was built and field-tested under a prior (also DoE- and NGA co-funded) program, and served as the validation that self-powered robots under wireless control could access and navigate live natural gas distribution mains. The X-II system design ({approx}8 ft. and 66 lbs.) was heavily based on the X-I design, yet was substantially expanded to allow the addition of NDE sensor systems (while retaining its visual inspection capability), making it a modular system, and expanding its ability to operate at pressures up to 750 psig (high-pressure and unpiggable steel-pipe distribution mains). A new electronics architecture and on-board software kernel were added to again improve system performance. A locating sonde system was integrated to allow for absolute position-referencing during inspection (coupled with external differential GPS) and emergency-locating. The power system was upgraded to utilize lithium-based battery-cells for an increase in mission-time. The resulting robot-train system with CAD renderings of the individual modules. The system architecture now relies on a dual set of end camera-modules to house the 32-bit processors (Single-Board Computer or SBC) as well as the imaging and wireless (off-board) and CAN-based (on-board) communication hardware and software systems (as well as the sonde-coil and -electronics). The drive-module (2 ea.) are still responsible for bracing (and centering) to drive in push/pull fashion the robot train into and through the pipes and obstacles. The steering modules and their arrangement, still allow the robot to configure itself to perform any-angle (up to 90 deg) turns in any orientation (incl. vertical), and enable the live launching and recovery of the system using custom fittings and a (to be developed) launch-chamber/-tube. The battery modules are used to power the system, by providing power to the robot's bus. The support modules perform the functions of centration for the rest of the train as well as odometry pickups using incremental encoding schemes. The electronics architecture is based on a distributed (8-bit) microprocessor architecture (at least 1 in ea. module) communicating to a (one of two) 32-bit SBC, which manages all video-processing, posture and motion control as well as CAN and wireless communications. The operator controls the entire system from an off-board (laptop) controller, which is in constant wireless communication with the robot train in the pipe. The sensor modules collect data and forward it to the robot operator computer (via the CAN-wireless communications chain), who then transfers it to a dedicated NDE data-storage and post-processing computer for further (real-time or off-line) analysis. The prototype robot system was built and tested indoors and outdoors, outfitted with a Remote-Field Eddy Current (RFEC) sensor integrated as its main NDE sensor modality. An angled launcher, allowing for live launching and retrieval, was also built to suit custom angled launch-fittings from TDW. The prototype vehicle and launcher systems are shown. The complete system, including the in-pipe robot train, launcher, integrated NDE-sensor and real-time video and control console and NDE-data collection and -processing and real-time display, were demonstrated to all sponsors prior to proceeding into final field-trials--the individual components and setting for said acceptance demonstration are shown. The launcher-tube was also used to verify that the vehicle system is capable of operating in high-pressure environments, and is safely deployable using proper evacuating/purging techniques for operation in the potentially explosive natural gas environment. The test-setting and environment for safety-certification of the X-II robot platform and the launch and recovery procedures, is shown. Field-trials were successfully carried out in a live steel pipeline in Northwestern Pennsylvania. The robot was launched and recovered multiple times, travelling thousands of feet and communicating in real time with video and command-and-control (C&C) data under remote operator control from a laptop, with NDE sensor-data streaming to a second computer for storage, display and post-processing. Representative images of the activities and systems used in the week-long field-trial are shown. CMU also evaluated the ability of the X-II design to be able to integrate an MFL sensor, by adding additional drive-/battery-/steering- and support-modules to extend the X-II train.

03 NATURAL GAS↗

Evaluation of a large format image tube camera for the shuttle sortie mission

A large format image tube camera of a type under consideration for use on the Space Shuttle Sortie Missions is evaluated. The evaluation covers the following subjects: (1) resolving power of the system (2) geometrical characteristics of the system (distortion etc.) (3) shear characteristics of the fiber optic coupling (4) background effects in the tube (5) uniformity of response of the tube (as a function of wavelength) (6) detective quantum efficiency of the system (7) astronomical applications of the system. It must be noted that many of these characteristics are quantitatively unique to the particular tube under discussion and serve primarily to suggest what is possible with this type of tube.

Tifft, W. C.↗

Skylab simulator visual displays and training for joint observing programs

The complexity of the Skylab Apollo Telescope Mount (ATM) experiment operations necessitated the use of high fidelity simulations of the onboard visual displays and pointing system for crew training. The displays which were simulated included the H-alpha displays, XUV monitor display, XUV/slit/white light display, X-ray image display, and the white light coronagraph display. The pointing simulation was achieved by projecting film sequences which were subsequently viewed by TV cameras. An optical system in front of the vidicons simulated the pointing, roll, and zoom capabilities of the ATM and sensing systems. The simulation enabled the Skylab crewmen to obtain valuable integrated training combining such tasks as target recognition and status assessment, complex and the time dependent pointing operations, malfunction analyses, and rapid responses to flare and other transient events.

Holt, A. C.↗

Aerial photographic water color variations from pollution in the James River

A photographic flight was made over the James River on May 17, 1977. The data show that, in general, James River water has very high sunlight reflectance. In the Bailey Bay area this reflectance is drastically reduced. Also shown is a technique for normalizing off-axis variations in radiance film exposure from camera falloff and uneven sunlight conditions to the nadir value. After data normalization, a spectral analysis is performed that identifies Bailey Creek water in James River water. The spectral results when compared with laboratory spectrometer data indicate that reflectance from James River water is dominated by suspended matter, while the substance most likely responsible for reduced reflectance in Bailey Creek water is dissolved organic carbon.

Bressette, W. E.↗

Optimizing the emission, propagation, and focusing of an intense electron beam

Intense electron beams can be used to study the dynamical response of materials under shocks in order to adjust the models developed for hydrodynamics simulations. We present in this paper a characterization of beams produced in a field emission diode coupled to the generator RKA at CEA/CESTA. Cherenkov emission, produced by the beam interacting in a fused silica disk, was observed by fast optical cameras to estimate beam homogeneity. GEANT4 simulations were performed to estimate the transfer function of the silica target and to optimize the anode foil. First, we chose the best cathode material available among the most common materials used in field emission systems. In addition, we found that by optimization of the anode thickness, we could improve the spatial homogeneity of the beam which is of prime importance for computing the interaction of the beam with materials. Next, we changed the beam fluence by increasing the beam current and by reducing the beam radius. Finally, we studied the propagation and focusing of the electron beam in low pressure gases and observed that we could use self-magnetic field focusing in order to increase beam fluence at the target location. The experimental results are in good agreement with PIC simulations.

43 PARTICLE ACCELERATORS↗

Expanding the HAWC Observatory

The High Altitude Water Cherenkov Gamma-Ray Observatory is expanding its current array of 300 water tanks to include 350 outrigger tanks to increase sensitivity to gamma rays above 10 TeV. This involves creating and testing hardware with which to build the new tanks, including photomultiplier tubes, high voltage supply units, and flash analog to digital converters. My responsibilities this summer included preparing, testing and calibrating that equipment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration Refinements in Support of MISR

The Multi-angle Imaging SpectroRadiometer (MISR) is one of five instruments on-board the EOSI Terra spacecraft, and has collected science data since March 2000. A multi-angle capability is provided by ninecameras, which view up to 70' forward and aft of the spacecraft track and enable unique geophysical retrievals. Throughout its mission, a calibration team has made periodic refinements to the process used to calibrate MISR. These have resulted in improved absolute, and band and camera-relative calibrations, as well as in derived geophysical data products. Data reprocessing is on-going, such that these refinements also improve previous data acquisitions. The calibration process is believed to be mature at this time, with no other changes anticipated. Bimonthly deployments of the on-board-calibrator continue to monitor instrument response degradations, and provide correction coefficients needed to maintain the accuracy of the radiance products.

refinements↗

Portable COTS RGB Wavefront System for Real-time Turbulence Mitigation

Atmospheric effects reduce the ability to detect or identify objects of interest due to spatial and spectral scintillation. Algorithms alone cannot correct for turbulence over long-range horizontal paths. While adaptive optics methods work well for astronomical viewing, they are not readily adapted for complex imagery over long-range horizontal paths. At MSS Parallel in 2016, we presented our work for the red/green/blue (RGB) wavefront sensor. Since then, we have completed our system to combine an off-the-shelf high-frame-rate USB3 color camera with a compact 90 mm Maksutov-Cassegrain telescope and an OKO deformable mirror (DM) to create a portable, real-time RGB wavefront sensor and turbulence mitigation system. The telescope’s aperture is covered with an aluminum plate holding three separate narrowband color filters. These filters, specifically matched to the relative spectral response of the sensor’s Bayer mask, provide nearly complete separation of the three color images. This device enables portable imaging through atmospheric turbulence and analysis thereof, where relative motion of the three-color Bayer-pixel video provides real-time wavefront information on the second-order statistics of Kolmogorov turbulence. We measured relative RGB pixel shifts and controlled this mirror using an ODROID single-board computer. We developed a bench setup to calibrate the relationship between pixel shifts and the deformable mirror actuators. We demonstrated the feasibility of this system on a benchtop and on scenes at 700 meters showing real time correction.

47 OTHER INSTRUMENTATION↗

Exploring the Use of DSCOVR/EPIC Satellite Observations to Monitor Vegetation Phenology

Vegetation phenology plays a pivotal role in regulating several ecological processes and has profound impacts on global carbon exchange. Large-scale vegetation phenology monitoring mostly relies on Low-Earth-Orbit satellite observations with low temporal resolutions, leaving gaps in data that are important for monitoring seasonal vegetation phenology. High temporal resolution satellite observations have the potential to fill this gap by frequently collecting observations on a global scale, making it easier to study change over time. This study explored the potential of using the Earth Polychromatic Imaging Camera (EPIC) onboard the Deep Space Climate Observatory (DSCOVR) satellite, which captures images of the entire sunlit face of the Earth at a temporal resolution of once every 1–2 h, to observe vegetation phenology cycles in North America. We assessed the strengths and shortcomings of EPIC-based phenology information in comparison with the Moderate-resolution Imaging Spectroradiometer (MODIS), Enhanced Thematic Mapper (ETM+) onboard Landsat 7, and PhenoCam ground-based observations across six different plant functional types. Our results indicated that EPIC could capture and characterize seasonal changes of vegetation across different plant functional types and is particularly consistent in the estimated growing season length. Our results also provided new insights into the complementary features and benefits of the four datasets, which is valuable for improving our understanding of the complex response of vegetation to global climate variability and other disturbances and the impact of phenology changes on ecosystem productivity and global carbon exchange.

Weber, Maridee A.↗

Low resistivity W{sub x}V{sub 1−x}O{sub 2}-based multilayer structure with high temperature coefficient of resistance for microbolometer applications

Materials that exhibit semiconductor-to-metal phase transition (SMT) are commonly used as sensing layers for the fabrication of uncooled microbolometers. The development of highly responsive microbolometers would benefit from using a sensing material that possesses a large thermal coefficient of resistance (TCR) close to room temperature and a resistivity low enough to compromise between noise reduction and high TCR, while it should also satisfies the requirements of current CMOS technology. Moreover, a TCR that remains constant when the IR camera surrounding temperature varies would contribute to achieve reliable temperature measurements without additional corrections steps for TCR temperature dependence. In this paper, the characteristics of the SMT occurring in undoped and tungsten-doped vanadium dioxide thin films deposited on LaAlO{sub 3} (100) substrates are investigated. They are further exploited to fabricate a W{sub x}V{sub 1−x}O{sub 2} (0 ≤ x ≤ 2.5) multilayer structure exhibiting a bottom-up gradient of tungsten content. This MLS displays a combination of properties that is promising for application to uncooled microbolometer, such as a large TCR of −10.4%/ °C and low resistivity values ranging from 0.012 to 0.10 Ω-cm over the temperature range 22 °C–42 °C.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-F-T-232: Monthly Quality Assurance in External Beam Radiation Therapy Using a Single System

Purpose: Monthly quality assurance (QA) is time consuming for external beam radiation therapy, taking as long as 6–8 hours for each machine. It is due to the use and setup of multiple devices for different QA procedures. We have developed a single system with rotational capability for the measurement of both optical light and radiation which significantly reduces the time spent on Monthly QA. Methods: A single system using mirrors, a phosphor screen and a CCD camera is housed on a cylindrical motor so that it can rotate 360 degrees. For monthly QA, the system is placed on the patient couch of the medical accelerator with the plane of the phosphor screen at isocenter for all measurements. For optical QA such as optical distance indicator, room laser and light field, the optical image is collected directly with the camera. For radiation QA such as beam profile, MLC speed, picket-fence test, collimator rotation, table rotation and gantry rotation, a brass build-up plate is attached to the top of the phosphor screen. Two brass plates with islands of different thickness were designed for photon energy and electron energy constancy checks. Flex map, distortion map and uniformity map were developed to calibrate the motor bearing, camera/lens distortion, and the phosphor screen’s measured response across the field. Results: Following the TG142 guidelines for monthly QA with our system, the overall run time is reduced from 6–8 hours to 1.5 hours. Our system’s rotating design allows for quick testing of the gantry radiation isocenter test that is also independent of the sag of the gantry and the EPID. Conclusion: Our system significantly shortens the time needed for monthly QA by unifying the tests with a single system. Future work will be focused on extending the technology to Brachytherapy, IMRT and proton therapy QAs. This work is funded in part by a sponsor research grant from JPLC who owns the Raven technology. John Wong is a co-founder of JPLC.

07 ISOTOPE AND RADIATION SOURCES↗