Search NASA⌕ Search

SEARCH · Search NASA

Results for “cleaning methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Low extractable wipers for cleaning space flight hardware

There is a need for low extractable wipers for solvent cleaning of space flight hardware. Soxhlet extraction is the method utilized today by most NASA subcontractors, but there may be alternate methods to achieve the same results. The need for low non-volatile residue materials, the history of soxhlet extraction, and proposed alternate methods are discussed, as well as different types of wipers, test methods, and current standards.

Tijerina, Veronica↗

Energy Data from Heat Pumps Installed in Juneau, AK

Heat pumps offer a great low carbon emission method to heat homes. Thermalize Juneau 2021 was a clean energy campaign that helped homeowners in Juneau, Alaska install heat pumps into their homes. Juneau is located near the climactic limit of many heat pumps, and we were interested in how well the heat pumps can function in cold climates. This was done by using Sense meters to remotely monitor the energy usage of 10 homes with heat pumps. The Sense meters are small devices that connect to the electrical panel and monitor the energy use of multiple appliances through machine learning. First, we recorded the energy usage of a heat pump in the lab using both the Sense meter and the existing lab datalogger. Both recorded very similar energy usage data which confirmed that the Sense meter can accurately measure the fluctuations in the heat pump energy use. Next, we looked at the energy data from the Sense meters in the homes with heat pumps and paired it with local weather data to see how well the heat pumps functioned in the cold weather.

Alaska↗

Streamlining and Simplifying the Chemical Separationof Berkelium (249Bk) from Other Actinides/Lanthanides andFission Products

Abstract Separation of an individual heavy actinide from other actinides, lanthanides, and coproduced fission products is challenging not only because of their similarity in chemistry but also because the chemistry of heavy actinides is largely unknown. At present, the cation-exchange chromatography with α-hydroxyisobutyric acid (CX-AHIB) method is used to isolate milli- to picogram quantities of heavy actinides (i.e., 249Bk, 252Cf, 254Es, and 257Fm). This method allows simultaneous separation of these actinides; however, isolating a clean individual product with a high yield has proven challenging. The process is also very slow and labor-intensive and requires precise control of various chemical conditions, such as pH, temperature, and AHIB concentration. Developing a separation scheme for heavy actinides requires identifying their unique feature and then harnessing this feature in the separation process design. The unique characteristic of Bk4+ is that it does not adsorb onto anion exchange resin columns, unlike other tetravalent actinides. This article discusses what makes Bk unique and how this discovery led to a new method for separating Bk from adjacent actinides, lanthanides, and coproduced fission products. The method employed two different resin columns in tandem to separate unwanted actinides from 249Bk, followed by fine cleanup of 249Bk. The advantages of the new Bk method over the CX-AHIB method in Bk production are discussed, and the performance and robustness of the proposed method were assessed in two recent production campaigns.

Chemistry↗

Extraction of the electron excess temperature in terahertz quantum cascade lasers from laser characteristics

Abstract We propose a method to extract the upper laser level’s (ULL’s) excess electronic temperature from the analysis of the maximum light output power ( P max ) and current dynamic range Δ J d = ( J max − J th ) of terahertz quantum cascade lasers (THz QCLs). We validated this method, both through simulation and experiment, by applying it on THz QCLs supporting a clean three-level system. Detailed knowledge of electronic excess temperatures is of utmost importance in order to achieve high temperature performance of THz QCLs. Our method is simple and can be easily implemented, meaning an extraction of the excess electron temperature can be achieved without intensive experimental effort. This knowledge should pave the way toward improvement of the temperature performance of THz QCLs beyond the state-of-the-art.

47 OTHER INSTRUMENTATION↗

Automated Clean Chemistry for Bulk Analysis of Environmental Swipe Samples – Final Report

Sample preparation methods for mass spectrometry are being automated using commercial-off-the-shelf (COTS) equipment to shorten lengthy and costly manual chemical purification procedures. This development addresses a serious need in the International Atomic Energy Agency’s (IAEA) Network of Analytical Laboratories (NWAL) to increase efficiency in the Bulk Analysis of Environmental Samples for Safeguards program with a method that allows unattended, overnight operation. In collaboration with Elemental Scientific Inc. (ESI), the prepFAST-MC2 was designed based on COTS equipment. It was modified for uranium/plutonium separations using renewable columns packed with Eichrom TEVA® and UTEVA® resins, with a chemical separation method based on the Oak Ridge National Laboratory (ORNL) NWAL chemical procedure. Initial verification of individual columns yielded small elution volumes with consistent elution profiles and good recovery. Combined column calibration demonstrated ample separation without crosscontamination of the eluent. Automated packing and unpacking of the built-in columns initially showed >15% deviation in resin loading by weight, which can lead to inconsistent separations. Optimization of the packing and unpacking methods led to a reduction in the variability of the packed resin to less than 5% daily. Based on the initial experience at ORNL with the prepFAST-MC2, a second-generation model, the prepFAST-SR, was built by ESI. The newly designed prepFAST-SR has several upgrades compared with the original prepFAST-MC2. The upgrades largely addressed issues with the reliability of unpacking the Eichrom columns and with ventilation to ensure adequate removal of acid vapors. Both systems are currently installed in the Ultra-Trace Forensics Science Center at ORNL. Separations of mixed uranium and plutonium samples containing certified reference materials were analyzed by multi-collector inductively coupled plasma mass spectrometry and yielded good results. Current efforts have demonstrated a wider applicability of the prepFAST system. Near-quantitative removal of metal interferences was achieved with the system in both uranium and plutonium separated fractions. Successful system validation was completed with several archived samples. Isotopic results from archived samples and certified reference materials were well within data quality limits for the IAEA NWAL. Additional COTS equipment has been evaluated for its potential to aid the prepFAST-SR system in reducing the time allotments and cleanroom infrastructure requirements for accurate separations. Overall, these efforts help ensure continued efficient and effective operation of the NWAL. Comparison of the amount of personnel time necessary for successful manual vs. automated chemical separations showed a significant decrease in hands-on time from 9.8 hours to 35 minutes for seven samples, respectively. This documented time savings and reduced labor translates to a significant cost savings per sample. Overall, the system will enable faster sample reporting times at reduced cost by limiting personnel hours dedicated to the chemical separation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Extraction technique for the determination of oxygen-18 in water using preevacuated glass vials

The need for a rapid, inexpensive technique for routine 18O/16O extraction from water has arisen recently through applications in the medical sciences and in hydrology. The traditional experimental technique for determining the oxygen isotope composition of water, the CO2-H2O equilibration method, is tedious, time consuming, and involves the use of custom-made glass apparatus. Furthermore, because of potential memory effects from one sample to the next, the glassware needs to be thoroughly cleaned between runs. A few attempts have been made to improve upon the method. Attempts to analyze water directly in the source of the mass spectrometer produced large memory effects and questionable results. Commercially available apparatus for automated extraction of 18O/16O from water is generally prohibitively expensive and often is designed to interface only with the manufacturer's own mass spectrometer. The method described in this paper utilizes inexpensive, off-the-shelf, preevacuated, glass vials. Preevacuated vials have been used by others for the isotopic analysis of breath CO2 and are well tested. The vials can be purchased in bulk from scientific apparatus suppliers at a relatively low cost. These are coupled with a simplified extraction line consisting of a stainless steel syringe needle and a glass cold trap. Vials are filled with CO2 and H2O and shaken in a constant-temperature water bath for at least 90 min. Since the vials are discarded after use, no cleaning is necessary, essentially eliminating any memory effect. Reproducibility is generally better than +/- 0.05%. The only reagents required are gaseous CO2 for equilibration, a dry ice/alcohol mixture for trapping water, and liquid nitrogen for transferring the CO2.

NASA Discipline Number 52-10↗

SULI Intern Final Report: Computationally Investigating Hydrogen Thermo-Diffusion in Yttrium Hydride Using Multiscale Methods

The renaissance of nuclear energy has arrived, heralding an age of abundant inexpensive clean energy, and renewed space exploration. In nuclear-powered spacecraft and microreactors, safety and size are of utmost importance. Yttrium Hydride (YHx) is being researched for its utility as a neutron moderator in nuclear reactors; the hydrogen in YHx slows down neutrons, enabling a continuous nuclear reaction in the reactor. This has the benefit of allowing reactors to be more safe, compact, and efficient. The goal of this effort is to computationally predict the coefficient of temperature-dependent hydrogen diffusion within YHx, the Soret coefficient. This parameter is essential for determining the safe operating modes of YHx moderators. Zirconium Hydride (ZrHx) is used in the Training, Research, Isotopes, General Atomics (TRIGA) reactor, is the reference material for these calculations. In this work, nanoscale atomic modeling in the Vienna Ab initio Simulation Package (VASP) is combined with the mesoscale finite element phase-field module in the Multiphysics Object-Oriented Simulation Environment (MOOSE); this culminates in a new multiscale computational method to simulate Soret diffusion of hydrogen in YHx. This data is useful for predicting experimental outcomes. This workflow involves convergence testing followed by static, Nudged Elastic Band (NEB), Quasi-Harmonic Approximation (QHA), and Molecular Dynamics (MD) calculations - linked with phase field simulation. NEB simulates hydrogen migration, while QHA and MD predict temperature-dependent properties. The static calculations align with literature, and preliminary NEB and QHA calculations yield accurate results. Once the atomic calculations are complete, we will incorporate Electron Backscatter Diffraction (EBSD) images and VASP-generated parameters into the phase field module to simulate intra- and intergranular transport of hydrogen in ZrHx and YHx. Future research will extend our approach to fuel-moderator materials systems such as Uranium-Yttrium Hydride (U-YHx). This work contributes to the development of advanced nuclear energy solutions for space travel.

36 - MATERIALS SCIENCE↗

A Facile Degumming Method of Kenaf Fibers Using Deep Eutectic Solution

An eco-friendly and effective degumming method needed to be developed for producing kenaf bast fibers. As such, this study devised a novel deep eutectic solvent (DES) method coupled with microwave and alkaline-ultrasonic treatment. The novel method could effectively remove the gummy matters, providing a smooth and clean fiber surface. The properties of the fibers were assessed including chemical compositions, surface structure, crystallinity index (66.68%) and thermal properties. The residual gum content (9.419%), fiber fineness (4.125tex), breaking tenacity (13.650 cn/tex) of the refined dry fibers produced by the novel treatment were comparable with the fibers produced by the traditional two-step alkali boiling method. Besides, the novel method could reduce the usage of chemical, water and time by 48.9%, by 66.7% and 66.8%, respectively. These results revealed that the novel combined DES pretreatment is a practical and feasible pretreatment method for kenaf bast degumming, demonstrating its facile, green energy-saving and fast properties in the degumming process.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Synthesis of nanoparticles using ethanol

The present disclosure relates to methods for producing nanoparticles. The nanoparticles may be made using ethanol as the solvent and the reductant to fabricate noble-metal nanoparticles with a narrow particle size distributions, and to coat a thin metal shell on other metal cores. With or without carbon supports, particle size is controlled by fine-tuning the reduction power of ethanol, by adjusting the temperature, and by adding an alkaline solution during syntheses. The thickness of the added or coated metal shell can be varied easily from sub-monolayer to multiple layers in a seed-mediated growth process. The entire synthesis of designed core-shell catalysts can be completed using metal salts as the precursors with more than 98% yield; and, substantially no cleaning processes are necessary apart from simple rinsing. Accordingly, this method is considered to be a "green" chemistry method.

36 MATERIALS SCIENCE↗

ANALYSIS OF SAMPLES FROM TANK 5F CHEMICAL CLEANING

The Savannah River Site (SRS) is preparing Tank 5F for closure. The first step in preparing the tank for closure is mechanical sludge removal. Following mechanical sludge removal, SRS performed chemical cleaning with oxalic acid to remove the sludge heel. Personnel are currently assessing the effectiveness of the chemical cleaning. SRS personnel collected liquid samples during chemical cleaning and submitted them to Savannah River National Laboratory (SRNL) for analysis. Following chemical cleaning, they collected a solid sample (also known as 'process sample') and submitted it to SRNL for analysis. The authors analyzed these samples to assess the effectiveness of the chemical cleaning process. The conclusions from this work are: (1) With the exception of iron, the dissolution of sludge components from Tank 5F agreed with results from the actual waste demonstration performed in 2007. The fraction of iron removed from Tank 5F by chemical cleaning was significantly less than the fraction removed in the SRNL demonstrations. The likely cause of this difference is the high pH following the first oxalic acid strike. (2) Most of the sludge mass remaining in the tank is iron and nickel. (3) The remaining sludge contains approximately 26 kg of barium, 37 kg of chromium, and 37 kg of mercury. (4) Most of the radioactivity remaining in the residual material is beta emitters and {sup 90}Sr. (5) The chemical cleaning removed more than {approx} 90% of the uranium isotopes and {sup 137}Cs. (6) The chemical cleaning removed {approx} 70% of the neptunium, {approx} 83% of the {sup 90}Sr, and {approx} 21% of the {sup 60}Co. (7) The chemical cleaning removed less than 10% of the plutonium, americium, and curium isotopes. (8) The chemical cleaning removed more than 90% of the aluminium, calcium, and sodium from the tank. (9) The cleaning operations removed 61% of lithium, 88% of non-radioactive strontium, and 65% of zirconium. The {sup 90}Sr and non-radioactive strontium were measured by different methods, and the differences in the fraction removed are not statistically significant. (10) Chemical cleaning removed 10-50% of the barium, chromium, iron, magnesium, manganese, and silicon. (11) Chemical cleaning removed only {approx}1% of the nickel.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Alternate paddle configuration for improved wear resistance in the saltstone mixer

The Saltstone Production Facility has a 10-inch Readco-Kurimoto continuous mixer that mixes the premix dry feeds and low-level waste salt solution to make fresh (uncured) saltstone. Inspection of the mixer in January 2013 showed significant wear on the third, fourth and fifth paddle pairs after the conveying augers. A 2-inch Readco-Kurimoto continuous mixer was used to test alternate paddle configurations for use in the 10-inch mixer to decrease the wear rate on the paddles. Two wear tests were conducted to investigate a method of reducing wear on the mixer paddles. The first test (wear test 2a) had a paddle configuration similar to the currently installed 10-inch mixer in the SPF. This test established baseline wear. The second test (wear test 2b) had a reconfigured paddle arrangement that replaced the flat paddles with helical paddles for paddle pairs 2 - 6 and aligned paddle pair 1 with the augers. The intent of the reconfiguration was to more effectively convey the partially wetted dry feeds through the transition region and into the liquid feed where paddle wear is reduced due to dry feeds and salt solution being mixed at the intended water to premix ratio. The design of the helical paddles provides conveyance through the transition region to the liquid feed inlet. The alignment with the auger is aimed to provide a smoother transition (minimizing the discontinuity between the auger and paddle pair 1) into the downstream paddles. A soft metal with low wear resistance (6000 series aluminum) was used for the wear testing paddles to determine wear patterns while minimizing run time and maximizing wear rate. For the two paddle configurations tested using the scaled 2-inch Readco-Kurimoto continuous mixer, with the first six paddles after the augers replaced by the wear paddles and the remaining paddles were stainless steel. Since the 10-inch SPF mixer is designed with the liquid inlet centered over paddle pairs 5 and 6, the scaled 2-inch mixer was configured the same way. The wear rate from wear test 2a was approximately double the wear rate from wear test 2b for paddle pairs 4 and 5. For both configurations, there was little or no wear on paddle pairs 1, 2, 3 and 6 based on mass change, indicating that the un-wetted and fully wetted premix materials cause less wear than the partially wetted premix. Additionally, inspection of the wear surface of the paddles showed more deformation on the flat paddles than the helical paddles which was consistent with the wear rates. Aligning of the auger discharge flight with paddle pair 1 resulted in a lower wear rate paddle pair 1 rather than having them misaligned with the feed augers. During the paddle wear tests, polishing wear was observed on the inside barrel of the mixer. The polishing wear is evident on the upper housing clamshell and the lower housing clamshell primarily at paddle pairs 4 and 5, which is the transition region of the mixer. Wear on the mixer barrel increases the space between the paddles and the barrel, resulting in increased grout build up on the barrel. Since the mixer barrel cannot be reconfigured or replaced in the SPF, the method for mitigating wear on the barrel is to move the more viscous grout through the transition region as quickly as possible. In addition, the location of the liquid inlet does not allow for sufficient cleaning of the mixer since residual grout remains on paddle pairs 1 - 4. As the paddles continue to wear and the self-cleaning capability of the paddles is lost, the lack of sufficient flushing would aid in grout build up between the barrel and the paddles which could eventually lead to decreased throughput capacity of the dry feeds. Changing the paddle configuration from flat to helical resulted in no change to the rheological properties of the grout mixture. Both tests produced a grout that is within the processing range of the SPF. Based on the results of this testing, it is recommended for the currently installed SPF mixer that paddle pairs 1 through 6 be helical rather than flat, with the paddle pair 1 aligned with the feed augers in order to minimize the wear occurring in the SPF mixer. Based on the results of this testing, it is recommended that the mixer be inspected and critical measurements be taken whenever the SPF processing schedule allows in order to establish a wear rate of the 10-inch mixer paddles.5 Based on these measurements, the lifetime of paddles in the transition region can be established in order to set up a maintenance schedule for the mixer. Since replacing the entire mixer is very expensive and time intensive, replacing the worn paddles after a specific time period would allow for planned shutdowns as well as process optimization such that the mixer throughput is not compromised. In addition, further testing should be performed to determine an alternate liquid inlet location to better flush the mixer of residual grout at the end of processing. Sufficiently cleaning the mixer will help eliminate another potential source of wear. Another potential method for reducing the wear rate in the mixer is to reduce the mixer speed without affecting the throughput capacity. Since wear rate is a function of impact velocity of the grout and mixing paddles, testing could be done using the 2-inch mixer determine the optimum mixer speed to reduce wear but not adversely impact facility operations (e.g. throughput capacity and grout properties).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Influence of the Si(111)-7 Multiplication-Sign 7 surface reconstruction on the diffusion of strontium atoms

The diffusion of strontium atoms on the Si(111) surface at room temperature has been investigated using scanning tunnel microscopy and simulation carried out in terms of the density functional theory and the Monte Carlo method. It has been found that the reconstruction of a clean silicon surface with a 7 Multiplication-Sign 7 structure has a profound effect on the diffusion process. The average velocity of motion of a strontium atom in a unit cell of the 7 Multiplication-Sign 7 structure has been calculated. The main diffusion paths of a strontium atom and the corresponding activation energies have been determined. It has been demonstrated that the formation of scanning tunnel microscope images of the Si(111)-7 Multiplication-Sign 7 surface with adsorbed strontium atoms is significantly affected by the shift of the electron density from the strontium atom to the nearest neighbor silicon adatoms in the 7 Multiplication-Sign 7 structure.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Airplane Mesh Development with Grid Density Studies

Automatic Grid Generation Wish List Geometry handling, including CAD clean up and mesh generation, remains a major bottleneck in the application of CFD methods. There is a pressing need for greater automation in several aspects of the geometry preparation in order to reduce set up time and eliminate user intervention as much as possible. Starting from the CAD representation of a configuration, there may be holes or overlapping surfaces which require an intensive effort to establish cleanly abutting surface patches, and collections of many patches may need to be combined for more efficient use of the geometrical representation. Obtaining an accurate and suitable body conforming grid with an adequate distribution of points throughout the flow-field, for the flow conditions of interest, is often the most time consuming task for complex CFD applications. There is a need for a clean unambiguous definition of the CAD geometry. Ideally this would be carried out automatically by smart CAD clean up software. One could also define a standard piece-wise smooth surface representation suitable for use by computational methods and then create software to translate between the various CAD descriptions and the standard representation. Surface meshing remains a time consuming, user intensive procedure. There is a need for automated surface meshing, requiring only minimal user intervention to define the overall density of mesh points. The surface mesher should produce well shaped elements (triangles or quadrilaterals) whose size is determined initially according to the surface curvature with a minimum size for flat pieces, and later refined by the user in other regions if necessary. Present techniques for volume meshing all require some degree of user intervention. There is a need for fully automated and reliable volume mesh generation. In addition, it should be possible to create both surface and volume meshes that meet guaranteed measures of mesh quality (e.g. minimum and maximum angle, stretching ratios, etc.).

Cliff, Susan E.↗

Serrating Nozzle Surfaces for Complete Transfer of Droplets

A method of ensuring the complete transfer of liquid droplets from nozzles in microfluidic devices to nearby surfaces involves relatively simple geometric modification of the nozzle surfaces. The method is especially applicable to nozzles in print heads and similar devices required to dispense liquid droplets having precise volumes. Examples of such devices include heads for soft printing of ink on paper and heads for depositing droplets of deoxyribonucleic acid (DNA) or protein solutions on glass plates to form microarrays of spots for analysis. The main purpose served by the present method is to ensure that droplets transferred from a nozzle have consistent volume, as needed to ensure accuracy in microarray analysis or consistent appearance of printed text and images. In soft printing, droplets having consistent volume are generated inside a print head, but in the absence of the present method, the consistency is lost in printing because after each printing action (in which a drop is ejected from a nozzle), a small residual volume of liquid remains attached to the nozzle. By providing for complete transfer of droplets (and thus eliminating residual liquid attached to the nozzle) the method ensures consistency of volume of transferred droplets. An additional benefit of elimination of residue is prevention of cross-contamination among different liquids printed through the same nozzle a major consideration in DNA microarray analysis. The method also accelerates the printing process by minimizing the need to clean a printing head to prevent cross-contamination. Soft printing involves a hydrophobic nozzle surface and a hydrophilic print surface. When the two surfaces are brought into proximity such that a droplet in the nozzle makes contact with the print surface, a substantial portion of the droplet becomes transferred to the print surface. Then as the nozzle and the print surface are pulled apart, the droplet is pulled apart and most of the droplet remains on the print surface. The basic principle of the present method is to reduce the liquid-solid surface energy of the nozzle to a level sufficiently below the intrinsic solid-liquid surface energy of the nozzle material so that the droplet is not pulled apart and, instead, the entire droplet volume becomes transferred to the print surface. In this method, the liquid-solid surface energy is reduced by introducing artificial surface roughness in the form of micromachined serrations on the inner nozzle surface (see figure). The method was tested in experiments on soft printing of DNA solutions and of deionized water through 0.5-mm-diameter nozzles, of which some were not serrated, some were partially serrated, and some were fully serrated. In the nozzles without serrations, transfer was incomplete; that is, residual liquids remained in the nozzles after printing. However, in every nozzle in which at least half the inner surface was serrated, complete transfer of droplets to the print surface was achieved.

Kim, Chang-Jin "CJ"↗

Large scale alignment anomalies of CMB anisotropies: a new test for residuals applied to WMAP 5yr maps

We analyze the alignment of the low multipoles (quadrupole and octupole) of various maps of the WMAP 5yr release: the CMB maps obtained with ILC and MCMC methods, the CMB map in the V band after foreground reduction, and, for comparison, the (not cleaned) V band map. We study how much this alignment is polluted by residuals on the Galactic region. Among the considered maps, the WMAP-ILC turns out to be the most clean map from the point of view of the proposed test. This result has been found studying the redistribution (due to the masking process) of each bin of the probability distribution functions of the alignment estimators. By construction, our method, feasible through Monte Carlo simulations, works for any possible mask adopted in the analysis of data from current and forthcoming CMB anisotropy experiments and it can only exclude that the considered map is clean.

79 ASTRONOMY AND ASTROPHYSICS↗

A simple novel device for air sampling by electrokinetic capture

A variety of different sampling devices are currently available to acquire air samples for the study of the microbiome of the air. All have a degree of technical complexity that limits deployment. Here, we evaluate the use of a novel device, which has no technical complexity and is easily deployable. An air-cleaning device powered by electrokinetic propulsion has been adapted to provide a universal method for collecting samples of the aerobiome. Plasma-induced charge in aerosol particles causes propulsion to and capture on a counter-electrode. The flow of ions creates net bulk airflow, with no moving parts. A device and electrode assembly have been re-designed from air-cleaning technology to provide an average air flow of 120 lpm. This compares favorably with current air sampling devices based on physical air pumping. Capture efficiency was determined by comparison with a 0.4 μm polycarbonate reference filter, using fluorescent latex particles in a controlled environment chamber. Performance was compared with the same reference filter method in field studies in three different environments. For 23 common fungal species by quantitative polymerase chain reaction (qPCR), there was 100 % sensitivity and apparent specificity of 87%, with the reference filter taken as “gold standard.” Further, bacterial analysis of 16S RNA by amplicon sequencing showed equivalent community structure captured by the electrokinetic device and the reference filter. Unlike other current air sampling methods, capture of particles is determined by charge and so is not controlled by particle mass. We analyzed particle sizes captured from air, without regard to specific analyte by atomic force microscopy: particles at least as low as 100 nM could be captured from ambient air. This work introduces a very simple plug-and-play device that can sample air at a high-volume flow rate with no moving parts and collect particles down to the sub-micron range. In conclusion, the performance of the device is substantially equivalent to capture by pumping through a filter for microbiome analysis by quantitative PCR and amplicon sequencing.

47 OTHER INSTRUMENTATION↗

Atomic Oxygen Cleaning of Unpainted Plaster Sculptures

Atomic oxygen erosion of polymers has been found to be a threat to spacecraft in low Earth orbit. As a result ground facilities have been developed to identify coatings to protect polymers such as used for solar array blankets. As a result of extensive laboratory testing, it was discovered that soot and other organic contamination on paintings could be readily removed by atomic oxygen interactions with minimal damage to the artwork. No method, other than dusting, has been found to be effective in the cleaning of unpainted plaster sculptures This presentation discusses the atomic oxygen interaction processes and how effective they are for cleaning soot damaged unpainted plaster sculptures.

Atomic oxygen↗

Numerical Methods of Computational Electromagnetics for Complex Inhomogeneous Systems

Understanding electromagnetic phenomena is the key in many scientific investigation and engineering designs such as solar cell designs, studying biological ion channels for diseases, and creating clean fusion energies, among other things. The objectives of the project are to develop high order numerical methods to simulate evanescent electromagnetic waves occurring in plasmon solar cells and biological ion-channels, where local field enhancement within random media in the former and long range electrostatic interactions in the latter are of major challenges for accurate and efficient numerical computations. We have accomplished these objectives by developing high order numerical methods for solving Maxwell equations such as high order finite element basis for discontinuous Galerkin methods, well-conditioned Nedelec edge element method, divergence free finite element basis for MHD, and fast integral equation methods for layered media. These methods can be used to model the complex local field enhancement in plasmon solar cells. On the other hand, to treat long range electrostatic interaction in ion channels, we have developed image charge based method for a hybrid model in combining atomistic electrostatics and continuum Poisson-Boltzmann electrostatics. Such a hybrid model will speed up the molecular dynamics simulation of transport in biological ion-channels.

97 MATHEMATICS AND COMPUTING↗