Search NASA⌕ Search

SEARCH · Search NASA

Results for “computational imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Digital hardware and computer system for a digital image recorder.

Description of the digital memory and related computer system used at the Palomar Mountain Observatory. The memory was designed to have a large number of pixels, a high capacity for each pixel, and fast access for use with a variety of image sensors. As an image integration and storage device, this memory is shown to possess ideal properties, namely, it is strictly linear, has a wide dynamic range, and the image does not deteriorate with time. The observer has a visual display which enables him to monitor the image as it is being integrated.-

Dennison, E. W.↗

3D mapping of water in oolithic limestone at atmospheric and vacuum saturation using X-ray micro-CT differential imaging

Determining the distribution of fluids in porous sedimentary rocks is of great importance in many geological fields. However, this is not straightforward, especially in the case of complex sedimentary rocks like limestone, where a multidisciplinary approach is often needed to capture its broad, multimodal pore size distribution and complex pore geometries. This paper focuses on the porosity and fluid distribution in two varieties of Massangis limestone, a widely used natural building stone from the southeast part of the Paris basin (France). The Massangis limestone shows locally varying post-depositional alterations, resulting in different types of pore networks and very different water distributions within the limestone. Traditional techniques for characterizing the porosity and pore size distribution are compared with state-of-the-art neutron radiography and X-ray computed microtomography to visualize the distribution of water inside the limestone at different imbibition conditions. X-ray computed microtomography images have the great advantage to non-destructively visualize and analyze the pore space inside of a rock, but are often limited to the larger macropores in the rock due to resolution limitations. In this paper, differential imaging is successfully applied to the X-ray computed microtomography images to obtain sub-resolution information about fluid occupancy and to map the fluid distribution in three dimensions inside the scanned limestone samples. The detailed study of the pore space with differential imaging allows understanding the difference in the water uptake behavior of the limestone, a primary factor that affects the weathering of the rock. - Highlights: • The water distribution in a limestone was visualized in 3D with micro-CT. • Differential imaging allowed to map both macro and microporous zones in the rock. • The 3D study of the pore space clarified the difference in water uptake behavior. • Trapped air is visualized in the moldic macropores at atmospheric saturation.

36 MATERIALS SCIENCE↗

Estimation of Rectal Dose Using Daily Megavoltage Cone-Beam Computed Tomography and Deformable Image Registration

Purpose: The actual dose delivered to critical organs will differ from the simulated dose because of interfractional organ motion and deformation. Here, we developed a method to estimate the rectal dose in prostate intensity modulated radiation therapy with consideration to interfractional organ motion using daily megavoltage cone-beam computed tomography (MVCBCT). Methods and Materials: Under exemption status from our institutional review board, we retrospectively reviewed 231 series of MVCBCT of 8 patients with prostate cancer. On both planning CT (pCT) and MVCBCT images, the rectal contours were delineated and the CT value within the contours was replaced by the mean CT value within the pelvis, with the addition of 100 Hounsfield units. MVCBCT images were rigidly registered to pCT and then nonrigidly registered using B-Spline deformable image registration (DIR) with Velocity AI software. The concordance between the rectal contours on MVCBCT and pCT was evaluated using the Dice similarity coefficient (DSC). The dose distributions normalized for 1 fraction were also deformed and summed to estimate the actual total dose. Results: The DSC of all treatment fractions of 8 patients was improved from 0.75±0.04 (mean ±SD) to 0.90 ±0.02 by DIR. Six patients showed a decrease of the generalized equivalent uniform dose (gEUD) from total dose compared with treatment plans. Although the rectal volume of each treatment fraction did not show any correlation with the change in gEUD (R{sup 2}=0.18±0.13), the displacement of the center of gravity of rectal contours in the anterior-posterior (AP) direction showed an intermediate relationship (R{sup 2}=0.61±0.16). Conclusion: We developed a method for evaluation of rectal dose using DIR and MVCBCT images and showed the necessity of DIR for the evaluation of total dose. Displacement of the rectum in the AP direction showed a greater effect on the change in rectal dose compared with the rectal volume.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The vectorization of a ray tracing program for image generation

Ray tracing is a widely used method for producing realistic computer generated images. Ray tracing involves firing an imaginary ray from a view point, through a point on an image plane, into a three dimensional scene. The intersections of the ray with the objects in the scene determines what is visible at the point on the image plane. This process must be repeated many times, once for each point (commonly called a pixel) in the image plane. A typical image contains more than a million pixels making this process computationally expensive. A traditional ray tracing program processes one ray at a time. In such a serial approach, as much as ninety percent of the execution time is spent computing the intersection of a ray with the surface in the scene. With the CYBER 205, many rays can be intersected with all the bodies im the scene with a single series of vector operations. Vectorization of this intersection process results in large decreases in computation time. The CADLAB's interest in ray tracing stems from the need to produce realistic images of mechanical parts. A high quality image of a part during the design process can increase the productivity of the designer by helping him visualize the results of his work. To be useful in the design process, these images must be produced in a reasonable amount of time. This discussion will explain how the ray tracing process was vectorized and gives examples of the images obtained.

Plunkett, D. J.↗

Image-plane processing for improved computer vision

The proper combination of optical design with image plane processing, as in the mechanism of human vision, which allows to improve the performance of sensor array imaging systems for edge detection and location was examined. Two dimensional bandpass filtering during image formation, optimizes edge enhancement and minimizes data transmission. It permits control of the spatial imaging system response to tradeoff edge enhancement for sensitivity at low light levels. It is shown that most of the information, up to about 94%, is contained in the signal intensity transitions from which the location of edges is determined for raw primal sketches. Shading the lens transmittance to increase depth of field and using a hexagonal instead of square sensor array lattice to decrease sensitivity to edge orientation improves edge information about 10%.

Huck, F. O.↗

Exploiting voxel-sparsity for bone imaging with sparse-view cone-beam computed tomography

An optimization-based image reconstruction frame work is developed specifically for bone imaging. This framework exploits voxel-sparsity by use of ℓ 1 -norm image regularization and it enables image reconstruction from sparse-view cone-beam computed tomography (CBCT) acquisition. The effectiveness of the voxel-sparsity regularization is enhanced by using a blurred image representation. Ramp-filtering is included in the data discrepancy term and it has the effect of acting as a preconditioner, reducing the necessary number of iterations. The bone image reconstruction framework is demonstrated on CBCT data taken from an equine metacarpal condyle specimen.

Bone imaging↗

Analysis of deformable image registration accuracy using computational modeling

Computer aided modeling of anatomic deformation, allowing various techniques and protocols in radiation therapy to be systematically verified and studied, has become increasingly attractive. In this study the potential issues in deformable image registration (DIR) were analyzed based on two numerical phantoms: One, a synthesized, low intensity gradient prostate image, and the other a lung patient's CT image data set. Each phantom was modeled with region-specific material parameters with its deformation solved using a finite element method. The resultant displacements were used to construct a benchmark to quantify the displacement errors of the Demons and B-Spline-based registrations. The results show that the accuracy of these registration algorithms depends on the chosen parameters, the selection of which is closely associated with the intensity gradients of the underlying images. For the Demons algorithm, both single resolution (SR) and multiresolution (MR) registrations required approximately 300 iterations to reach an accuracy of 1.4 mm mean error in the lung patient's CT image (and 0.7 mm mean error averaged in the lung only). For the low gradient prostate phantom, these algorithms (both SR and MR) required at least 1600 iterations to reduce their mean errors to 2 mm. For the B-Spline algorithms, best performance (mean errors of 1.9 mm for SR and 1.6 mm for MR, respectively) on the low gradient prostate was achieved using five grid nodes in each direction. Adding more grid nodes resulted in larger errors. For the lung patient's CT data set, the B-Spline registrations required ten grid nodes in each direction for highest accuracy (1.4 mm for SR and 1.5 mm for MR). The numbers of iterations or grid nodes required for optimal registrations depended on the intensity gradients of the underlying images. In summary, the performance of the Demons and B-Spline registrations have been quantitatively evaluated using numerical phantoms. The results show that parameter selection for optimal accuracy is closely related to the intensity gradients of the underlying images. Also, the result that the DIR algorithms produce much lower errors in heterogeneous lung regions relative to homogeneous (low intensity gradient) regions, suggests that feature-based evaluation of deformable image registration accuracy must be viewed cautiously.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization and monitoring of subsurface processes using parallel computing and electrical resistivity imaging

This newsletter discusses recent advancement in subsurface resistivity characterization and monitoring capabilities. The BC Cribs field desiccation treatability test resistivity monitoring data is use an example to demonstrate near-real time 3D subsurface imaging capabilities. Electrical resistivity tomography (ERT) is a method of imaging the electrical resistivity distribution of the subsurface. An ERT data collection system consists of an array of electrodes, deployed on the ground surface or within boreholes, that are connected to a control unit which can access each electrode independently (Figure 1). A single measurement is collected by injecting current across a pair of current injection electrodes (source and sink), and measuring the resulting potential generated across a pair of potential measurement electrodes (positive and negative). An ERT data set is generated by collecting many such measurements using strategically selected current and potential electrode pairs. This data set is then processed using an inversion algorithm, which reconstructs an estimate (or image) of the electrical conductivity (i.e. the inverse of resistivity) distribution that gave rise to the measured data.

99 GENERAL AND MISCELLANEOUS↗

Computational modeling and neutron imaging to understand interface shape and solute segregation during the vertical gradient freeze growth of BaBrCl:Eu

In this work we apply continuum models to analyze phase change, heat transfer, fluid flow, solute transport, and segregation in order to understand prior neutron imaging observations of the vertical gradient freeze growth of Eu-doped BaBrCl. The models provide a rigorous framework in which to understand the mechanisms that are responsible for the complicated evolution of interface shape and dopant distribution in the growth experiment. We explain how a transition in the solid/liquid interface shape from concave to convex is driven by changes in radial heat transfer caused by furnace design. We also provide a mechanistic explanation of how dynamic growth conditions and changes of the flow structure in the melt result in complicated segregation patterns in this system. A growth pause caused by controller lock-up is shown to result in a band of solute depletion in accordance with classical theory. However, changing flow patterns during growth result in a non-monotonic axial distribution of solute that cannot be explained by simple application of classical segregation models. We assert that the approach presented here, namely the use of rigorous models in conjunction advanced diagnostics, such as neutron imaging, provides an exciting path forward for process optimization and control, accelerating the incremental advances that have, in the past, typically relied on empiricism, experience, and intuition.

36 MATERIALS SCIENCE↗

Investigation of Helical Tomotherapy for Partial-Breast Irradiation of Prone-Positioned Patients

Purpose: To investigate whether helical tomotherapy can provide conformal, uniform target-dose coverage for partial-breast irradiation (PBI) of patients positioned prone while achieving organ-at-risk sparing compliant with National Surgical Adjuvant Breast and Bowel Project (NSABP) B-39/Radiation Therapy Oncology Group (RTOG) 0413 guidelines; and to report our initial experience with the delivery of prone-breast PBI treatments using tomotherapy. Methods and Materials: For our pilot study, we generated helical tomotherapy plans upon the images of 10 prone-positioned patients previously treated using conventional techniques. We also generated plans for 4 left-breast prone-positioned PBI patients who were treated using helical tomotherapy, and recalculated the planned sinograms upon the pretreatment megavoltage computed tomographic images. Of the planning target volume (PTV), 95% was prescribed to receive 38.5 Gy, administered twice daily for 5 days. Results: For our pilot study, on average the maximum point dose to the PTV was 41.3 Gy, and 99% or more of the PTV received 90% or more of the prescribed dose. RTOG 0413 dose-volume histogram objectives were fulfilled for all organs at risk except the contralateral breast, which received a maximum point dose as high as 3.2 Gy in 1 case. For the prospective prone-positioned tomotherapy PBI plans, all objectives were met except the contralateral-breast maximum dose, which was 3.7 Gy on average. Dose calculation using the planned sinogram upon the pretreatment megavoltage computed tomographic images indicated consistency with the planned dose distributions. Conclusions: Helical tomotherapy can provide conformal and uniform target-dose coverage simultaneous with adequate sparing of critical structures; in this study only the contralateral breast dose exceeded RTOG 0413 guidelines. Dosimetric results for our 4 prospective patient cases were consistent with those for our 10-case pilot study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Wavefront Control and Image Restoration with Less Computing

PseudoDiversity is a method of recovering the wavefront in a sparse- or segmented- aperture optical system typified by an interferometer or a telescope equipped with an adaptive primary mirror consisting of controllably slightly moveable segments. (PseudoDiversity should not be confused with a radio-antenna-arraying method called pseudodiversity.) As in the cases of other wavefront- recovery methods, the streams of wavefront data generated by means of PseudoDiversity are used as feedback signals for controlling electromechanical actuators of the various segments so as to correct wavefront errors and thereby, for example, obtain a clearer, steadier image of a distant object in the presence of atmospheric turbulence. There are numerous potential applications in astronomy, remote sensing from aircraft and spacecraft, targeting missiles, sighting military targets, and medical imaging (including microscopy) through such intervening media as cells or water. In comparison with prior wavefront-recovery methods used in adaptive optics, PseudoDiversity involves considerably simpler equipment and procedures and less computation. For PseudoDiversity, there is no need to install separate metrological equipment or to use any optomechanical components beyond those that are already parts of the optical system to which the method is applied. In Pseudo- Diversity, the actuators of a subset of the segments or subapertures are driven to make the segments dither in the piston, tilt, and tip degrees of freedom. Each aperture is dithered at a unique frequency at an amplitude of a half wavelength of light. During the dithering, images on the focal plane are detected and digitized at a rate of at least four samples per dither period. In the processing of the image samples, the use of different dither frequencies makes it possible to determine the separate effects of the various dithered segments or apertures. The digitized image-detector outputs are processed in the spatial-frequency (Fourier-transform) domain to obtain measures of the piston, tip, and tilt errors over each segment or subaperture. Once these measures are known, they are fed back to the actuators to correct the errors. In addition, measures of errors that remain after correction by use of the actuators are further utilized in an algorithm in which the image is phase-corrected in the spatial-frequency domain and then transformed back to the spatial domain at each time step and summed with the images from all previous time steps to obtain a final image having a greater signal-to-noise ratio (and, hence, a visual quality) higher than would otherwise be attainable.

Lyon, Richard G.↗

The cortex transform - Rapid computation of simulated neural images

With a goal of providing means for accelerating the image processing, machine vision, and testing of human vision models, an image transform was designed, which makes it possible to map an image into a set of images that vary in resolution and orientation. Each pixel in the output may be regarded as the simulated response of a neuron in human visual cortex. The transform is amenable to a number of shortcuts that greatly reduce the amount of computation.

Watson, Andrew B.↗

Use of multiresolution wavelet feature pyramids for automatic registration of multisensor imagery

The problem of image registration, or the alignment of two or more images representing the same scene or object, has to be addressed in various disciplines that employ digital imaging. In the area of remote sensing, just like in medical imaging or computer vision, it is necessary to design robust, fast, and widely applicable algorithms that would allow automatic registration of images generated by various imaging platforms at the same or different times and that would provide subpixel accuracy. One of the main issues that needs to be addressed when developing a registration algorithm is what type of information should be extracted from the images being registered, to be used in the search for the geometric transformation that best aligns them. The main objective of this paper is to evaluate several wavelet pyramids that may be used both for invariant feature extraction and for representing images at multiple spatial resolutions to accelerate registration. We find that the bandpass wavelets obtained from the steerable pyramid due to Simoncelli performs best in terms of accuracy and consistency, while the low-pass wavelets obtained from the same pyramid give the best results in terms of the radius of convergence. Based on these findings, we propose a modification of a gradient-based registration algorithm that has recently been developed for medical data. We test the modified algorithm on several sets of real and synthetic satellite imagery.

Evaluation Studies↗

Computed Tomography 3-D Imaging of the Metal Deformation Flow Path in Friction Stir Welding

In friction stir welding (FSW), a rotating threaded pin tool is inserted into a weld seam and literally stirs the edges of the seam together. To determine optimal processing parameters for producing a defect free weld, a better understanding of the resulting metal deformation flow path is required. Marker studies are the principal method of studying the metal deformation flow path around the FSW pin tool. In our study, we have used computed tomography (CT) scans to reveal the flow pattern of a lead wire embedded in a FSW weld seam. At the welding temperature of aluminum, the lead becomes molten and is carried with the macro-flow of the weld metal. By using CT images, a 3-dimensional (3D) image of the lead flow pattern can be reconstructed. CT imaging was found to be a convenient and comprehensive way of collecting and displaying tracer data. It marks an advance over previous more tedious and ambiguous radiographic/metallographic data collection methods.

Schneider, Judy↗

Cone-beam Computed Tomography-guided Stereotactic Liver Punctures: A Phantom Study

Purpose: Images from computed tomography (CT), combined with navigation systems, improve the outcomes of local thermal therapies that are dependent on accurate probe placement. Although the usage of CT is desired, its availability for time-consuming radiological interventions is limited. Alternatively, three-dimensional images from C-arm cone-beam CT (CBCT) can be used. The goal of this study was to evaluate the accuracy of navigated CBCT-guided needle punctures, controlled with CT scans. Methods: Five series of five navigated punctures were performed on a nonrigid phantom using a liver specific navigation system and CBCT volumetric dataset for planning and navigation. To mimic targets, five titanium screws were fixed to the phantom. Target positioning accuracy (TPE{sub CBCT}) was computed from control CT scans and divided into lateral and longitudinal components. Additionally, CBCT-CT guidance accuracy was deducted by performing CBCT-to-CT image coregistration and measuring TPE{sub CBCT-CT} from fused datasets. Image coregistration was evaluated using fiducial registration error (FRE{sub CBCT-CT}) and target registration error (TRE{sub CBCT-CT}). Results: Positioning accuracies in lateral directions pertaining to CBCT (TPE{sub CBCT} = 2.1 {+-} 1.0 mm) were found to be better to those achieved from previous study using CT (TPE{sub CT} = 2.3 {+-} 1.3 mm). Image coregistration error was 0.3 {+-} 0.1 mm, resulting in an average TRE of 2.1 {+-} 0.7 mm (N = 5 targets) and average Euclidean TPE{sub CBCT-CT} of 3.1 {+-} 1.3 mm. Conclusions: Stereotactic needle punctures might be planned and performed on volumetric CBCT images and controlled with multidetector CT with positioning accuracy higher or similar to those performed using CT scanners.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phantom-based experimental validation of computational fluid dynamics simulations on cerebral aneurysms

Purpose: Recently, image-based computational fluid dynamics (CFD) simulation has been applied to investigate the hemodynamics inside human cerebral aneurysms. The knowledge of the computed three-dimensional flow fields is used for clinical risk assessment and treatment decision making. However, the reliability of the application specific CFD results has not been thoroughly validated yet. Methods: In this work, by exploiting a phantom aneurysm model, the authors therefore aim to prove the reliability of the CFD results obtained from simulations with sufficiently accurate input boundary conditions. To confirm the correlation between the CFD results and the reality, virtual angiograms are generated by the simulation pipeline and are quantitatively compared to the experimentally acquired angiograms. In addition, a parametric study has been carried out to systematically investigate the influence of the input parameters associated with the current measuring techniques on the flow patterns. Results: Qualitative and quantitative evaluations demonstrate good agreement between the simulated and the real flow dynamics. Discrepancies of less than 15% are found for the relative root mean square errors of time intensity curve comparisons from each selected characteristic position. The investigated input parameters show different influences on the simulation results, indicating the desired accuracy in the measurements. Conclusions: This study provides a comprehensive validation method of CFD simulation for reproducing the real flow field in the cerebral aneurysm phantom under well controlled conditions. The reliability of the CFD is well confirmed. Through the parametric study, it is possible to assess the degree of validity of the associated CFD model based on the parameter values and their estimated accuracy range.

42 ENGINEERING↗

Real-time out-of-plane artifact subtraction tomosynthesis imaging using prior CT for scanning beam digital x-ray system

Purpose: The scanning beam digital x-ray system (SBDX) is an inverse geometry fluoroscopic system with high dose efficiency and the ability to perform continuous real-time tomosynthesis in multiple planes. This system could be used for image guidance during lung nodule biopsy. However, the reconstructed images suffer from strong out-of-plane artifact due to the small tomographic angle of the system. Methods: The authors propose an out-of-plane artifact subtraction tomosynthesis (OPAST) algorithm that utilizes a prior CT volume to augment the run-time image processing. A blur-and-add (BAA) analytical model, derived from the project-to-backproject physical model, permits the generation of tomosynthesis images that are a good approximation to the shift-and-add (SAA) reconstructed image. A computationally practical algorithm is proposed to simulate images and out-of-plane artifacts from patient-specific prior CT volumes using the BAA model. A 3D image registration algorithm to align the simulated and reconstructed images is described. The accuracy of the BAA analytical model and the OPAST algorithm was evaluated using three lung cancer patients’ CT data. The OPAST and image registration algorithms were also tested with added nonrigid respiratory motions. Results: Image similarity measurements, including the correlation coefficient, mean squared error, and structural similarity index, indicated that the BAA model is very accurate in simulating the SAA images from the prior CT for the SBDX system. The shift-variant effect of the BAA model can be ignored when the shifts between SBDX images and CT volumes are within ±10 mm in the x and y directions. The nodule visibility and depth resolution are improved by subtracting simulated artifacts from the reconstructions. The image registration and OPAST are robust in the presence of added respiratory motions. The dominant artifacts in the subtraction images are caused by the mismatches between the real object and the prior CT volume. Conclusions: Their proposed prior CT-augmented OPAST reconstruction algorithm improves lung nodule visibility and depth resolution for the SBDX system.

60 APPLIED LIFE SCIENCES↗

Real-time optical image processing techniques

Nonlinear real-time optical processing on spatial pulse frequency modulation has been pursued through the analysis, design, and fabrication of pulse frequency modulated halftone screens and the modification of micro-channel spatial light modulators (MSLMs). Micro-channel spatial light modulators are modified via the Fabry-Perot method to achieve the high gamma operation required for non-linear operation. Real-time nonlinear processing was performed using the halftone screen and MSLM. The experiments showed the effectiveness of the thresholding and also showed the needs of higher SBP for image processing. The Hughes LCLV has been characterized and found to yield high gamma (about 1.7) when operated in low frequency and low bias mode. Cascading of two LCLVs should also provide enough gamma for nonlinear processing. In this case, the SBP of the LCLV is sufficient but the uniformity of the LCLV needs improvement. These include image correlation, computer generation of holograms, pseudo-color image encoding for image enhancement, and associative-retrieval in neural processing. The discovery of the only known optical method for dynamic range compression of an input image in real-time by using GaAs photorefractive crystals is reported. Finally, a new architecture for non-linear multiple sensory, neural processing has been suggested.

Liu, Hua-Kuang↗