NREL Inflow Halo Phontonics Streamline XR Custom / Reviewed Data
This nacelle mounted LiDAR is a Halo Photonics StreamLine XR Scanning Doppler LiDAR, and it is front facing to measure the inflow in front of the turbine.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
This nacelle mounted LiDAR is a Halo Photonics StreamLine XR Scanning Doppler LiDAR, and it is front facing to measure the inflow in front of the turbine.
This dataset was generated using an iterative active learning strategy with the ArcaNN software package (https://github.com/arcann-chem/arcann_training) to train machine-learning interatomic potentials (MLIPs) for aqueous nitric acid. Each active-learning cycle consisted of three stages: (1) training, (2) exploration, and (3) labeling. The initial training set comprised approximately 800 randomly selected configurations from a previous study by Lewis et al. (https://doi.org/10.1021/jp205510q), which investigated nitric acid solutions at 2, 3, 4, and 5 mol/L. For all configurations, single-point calculations of atomic forces and total energies were performed at the quantum density functional theory BLYP-D2 and PBE-D3 levels of theory using the CP2K Quickstep module. Valence electrons were treated explicitly, while core electrons on all atoms were represented by norm-conserving Goedecker–Teter–Hutter (GTH) pseudopotentials. Long-range dispersion interactions were accounted for using Grimme dispersion corrections. Wave functions were expanded in a mixed Gaussian-and-plane-wave scheme using TZV2P-MOLOPT basis sets for all elements and an 800 Ry auxiliary plane-wave cutoff for the electron density. Self-consistent field convergence was accelerated using orbital transformation and Direct Inversion in the Iterative Subspace, with a convergence threshold of 10^{-6}. All single-point calculations were carried out in periodic orthorhombic cells whose dimensions match those of the molecular configurations sampled from earlier trajectories. The CELL_REF keyword in CP2K was used to define a fixed reference cell, ensuring consistency in the reference data used for MLIP training, particularly when cell fluctuations are present in NpT simulations. The resulting high-fidelity energies and forces constitute the ground-truth labels used to train the MLIPs contained in this dataset.
This dataset was generated using an iterative active-learning strategy implemented in the ArcaNN software package (https://github.com/arcann-chem/arcann_training) to train machine-learning interatomic potentials for aqueous ZnCl2 solutions. Each active-learning cycle consisted of three stages: training, exploration, and labeling. The initial training set combined configurations generated in this work from enhanced-sampling ab initio molecular dynamics simulations with configurations from a previously reported neural-network-potential study of aqueous ZnCl2. The enhanced-sampling ab initio molecular dynamics simulations involved Zn–Cl separation and the chloride coordination number around Zn²? as collective variables. These configurations served as the seed dataset. Subsequent active-learning cycles expanded the training set by identifying and labeling configurations that were poorly represented by the current models, thereby improving coverage of ion-association states and changes in local coordination and charge-state environments relevant to the solution free-energy landscape. For all selected configurations, single-point calculations of the total energies and atomic forces were performed within density functional theory using the CP2K Quickstep module. Reference calculations employed the revPBE-D3 and r2SCAN exchange-correlation functionals. Motivated by recent work on aqueous Zn²?, the main revPBE calculations omitted D3 dispersion contributions involving Zn²?, while retaining the D3 correction for water and chloride. For comparison, fully dispersion-corrected revPBE-D3 reference calculations were also performed, with D3 applied to all species, including Zn²?. Valence electrons were treated explicitly, while core electrons were represented using norm-conserving Goedecker–Teter–Hutter pseudopotentials. The wave functions were expanded using the mixed Gaussian-and-plane-wave scheme with TZV2P-MOLOPT basis sets for all elements and a 600 Ry auxiliary plane-wave cutoff for the electron density. Self-consistent-field convergence was accelerated using the orbital-transformation and Direct Inversion in the Iterative Subspace algorithms, with a convergence threshold of 10?6. All single-point calculations were performed in periodic orthorhombic cells. The CELL_REF keyword in CP2K was used to define a fixed reference cell with a box length of 25 Å. This treatment ensured a consistent reference for configurations extracted from NpT trajectories with fluctuating cell dimensions. The resulting DFT energies and atomic forces constitute the ground-truth labels used to train the MLIPs. The resulting MLIP was trained for aqueous ZnCl2 solutions spanning concentrations from 0 to 30 molal and a broad pH range, from strongly acidic to strongly basic conditions. Representative examples of configurations included in the MLIP training dataset are provided below. These include 1) Representative configurations from the dataset labeled at the revPBE-D3 level, with D3 dispersion interactions involving Zn2+ excluded (revPBE-wo-D3). 2) Representative configurations from the dataset labeled at the fully dispersion-corrected revPBE-D3 level, with D3 interactions applied to all species, including Zn2+ (revPBE-D3). 3) Representative configurations from the dataset labeled at the r2SCAN level of theory (r2SCAN).
In this tutorial narrative, we introduce a novel template developed to enable the creation of stoichiometric genome-scale metabolic models for iron-oxidizing bacteria. We demonstrate the development of this template by applying it to Sideroxydans lithotrophicus ES-1, and validate our model using transcriptomic data (Published in Zhou et al., 2022 AEM). Below, we further show that our template facilitates the modeling of mixotrophic iron-oxidizing bacteria and metagenome-assembled genomes (MAGs), by applying our template to the MAG of the mixotrophic iron oxidizer Leptothrix ochracea (Published in Tothero et al, 2024). This work represents the first instance of a generalized and adaptable template for modeling diverse iron-oxidizing microbial systems, expanding the accessibility and applicability of metabolic modeling in this field.
Advances in DNA synthesis have enabled the construction of artificial genes, gene circuits, and genomes of bacterial scale. Freedom in de novo design of synthetic constructs provides significant power in studying the impact of mutations in sequence features, and verifying hypotheses on the functional information that is encoded in nucleic and amino acids. To aid this goal, a large number of software tools of variable sophistication have been implemented, enabling the design of synthetic genes for sequence optimization based on rationally defined properties. The first generation of tools dealt predominantly with singular objectives such as codon usage optimization and unique restriction site incorporation. Recent years have seen the emergence of sequence design tools that aim to evolve sequences toward combinations of objectives. The design of optimal protein-coding sequences adhering to multiple objectives is computationally hard, and most tools rely on heuristics to sample the vast sequence design space. In this review, we study some of the algorithmic issues behind gene optimization and the approaches that different tools have adopted to redesign genes and optimize desired coding features. We utilize test cases to demonstrate the efficiency of each approach, as well as identify their strengths and limitations.
Transient terahertz time-domain spectroscopy (THz-TDS) imaging has emerged as a novel non-ionizing and noninvasive biomedical imaging modality, designed for the detection and characterization of a variety of tissue malignancies due to their high signal-to-noise ratio and submillimeter resolution. We report our design of a pair of aspheric focusing lenses using a commercially available lens-design software that resulted in about 200 × 200-μm2 focal spot size corresponding to the 1-THz frequency. The lenses are made of high-density polyethylene (HDPE) obtained using a lathe fabrication and are integrated into a THz-TDS system that includes low-temperature GaAs photoconductive antennae as both a THz emitter and detector. The system is used to generate high-resolution, two-dimensional (2D) images of formalin-fixed, paraffin-embedded murine pancreas tissue blocks. The performance of these focusing lenses is compared to the older system based on a pair of short-focal-length, hemispherical polytetrafluoroethylene (TeflonTM) lenses and is characterized using THz-domain measurements, resulting in 2D maps of the tissue refractive index and absorption coefficient as imaging markers. For a quantitative evaluation of the lens effect on the image resolution, we formulated a lateral resolution parameter, R2080, defined as the distance required for a 20–80% transition of the imaging marker from the bare paraffin region to the tissue region in the same image frame. The R2080 parameter clearly demonstrates the advantage of the HDPE lenses over TeflonTM lenses. The lens-design approach presented here can be successfully implemented in other THz-TDS setups with known THz emitter and detector specifications.
We have developed an intermediate size (906 L) aerosol processing chamber, and this work reports on the design and initial characterization of dry aerosol experiments. Specifically, we are determining wall-loss and coagulation correction factors using the observed size distribution measurements for surrogates of common aerosol classes: sodium chloride, sucrose, and biomass burning aerosol smoke. Results show that, on average, sodium chloride, sucrose, and smoke wall-loss rates converge to similar values on relatively short time scales (< 1 h). The fitted coagulation correction factor, W C -1 , for smoke particles (1.23 ± 0.312), indicates that on average they adhere to each other more than sodium chloride (0.969 ± 0.524) and sucrose (1.16 ± 1.38). The relative uncertainty is high for the coagulation correction, but it is consistent with our Monte Carlo error analysis. This study lays the foundation for future experiments at elevated humidity and supersaturation conditions to characterize the influence of particle shape on coagulation and cloud parameters.
Explore the source record for details and available documents.
Standard high pressure valves are used in low pressure fluid system testing when a substantial system pressure increase is required. The flow-vs-valve stroke is matched with that of the valves being replaced. Some correction to the plug contour may be necessary.
Optimal stock level with algorithm for random distribution
Thermal analysis of space hold performance of multilayer insulation on upper half of unshrouded liquid hydrogen tank within sun oriented vehicle
A commercial quadrupole residual gas analyzer system has been upgraded for operation at extended cable lengths. Operation inside a vacuum chamber for the standard quadrupole nude head is limited to approximately 2 m from its externally located rf/dc generator because of the detuning of the rf oscillator circuits by the coaxial cable reactance. The advance of long distance remote operation inside a vacuum chamber for distances of 45 and 60 m was made possible without altering the quadrupole's rf/dc generator circuit by employing an rf link to drive the quadrupole rods. Applications of the system have been accomplished for in situ space simulation thermal/vacuum testing of sophisticated payloads.
A commercial quadrupole mass spectrometer (residual gas analyzer, RGA) system has been modified to operate at large separations of its electronics console and sensing head. The methods implemented have made practical applications, as well as operation, of such a system possible for the first time. This advance was stimulated by a need for placing sensors at remote (45 or 60 m) chamber locations for space simulation testing of orbital flight spacecraft. Emphasis is placed on instrument functional requirements and describing the hardware changes and adjustment techniques necessary to assure operation at the extended cable lengths.
Automatic design technique uses standard circuit cells for producing large-scale integrated arrays. Computerized fabrication process provides individual cells of high density and efficiency, quick turnaround time, low cost, and ease of corrections for changes and errors.
A hybrid microcircuit standard was developed after a thorough review of applicable NASA, military, industry, and technical society specifications and standards and compilation of comments from technical reviewers throughout the hybrid industry. The draft of the standard submitted to the technical reviewers, the comments from the reviewers, and the completed standard are discussed.
Technique for reworking stock bearings saves time and produces helicopter-rotor bearings ground more precisely. Split tapered ring at one end of threaded bolt expands to hold inside of inner race bearing assembly; nut, at other end of bolt, adjusts amount of spring tension. Piece of hardware grasps bearing firmly without interfering with grinding operation. Operation produces bearing of higher quality than commercially available bearings.
Development of a forecast of the total domestic telecommunications demand, identification of that portion of the telecommunications demand suitable for transmission by satellite systems, identification of that portion of the satellite market addressable by CPS systems, identification of that portion of the satellite market addressable by Ka-band CPS system, and postulation of a Ka-band CPS network on a nationwide and local level were achieved. The approach employed included the use of a variety of forecasting models, a parametric cost model, a market distribution model and a network optimization model. Forecasts were developed for: 1980, 1990, 2000; voice, data and video services; terrestrial and satellite delivery modes; and C, Ku and Ka-bands.
Microelectronic test chips contain a number of test structures that are used for a variety of purposes in fabricating integrated circuits. For convenience, their use is divided into six groups: layout-rule evaluating, process-parameter extraction, device-parameter extraction, circuit-parameter extraction, initial-fabrication failure analysis, and reliability failure analysis. A given test structure can be used to gather information in a number of these groups. Examples are given here of the kinds of parameters that can be obtained in each of these groups. A table is included summarizing various device failures common to bulk CMOS and indicating failure mechanisms appearing after wafer fabrication and after stress.