Search NASA⌕ Search

SEARCH · Search NASA

Results for “data reliability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Calibration of Single-Crystal TATB EOS

An equation of state (EOS) for the single-crystal TATB (C 6 H 6 N 6 O 6 , molar mass 258.15 g/mol) is calibrated using the experimental/computational calibration data uploaded to the caldata repository. The thermodynamically complete EOS is given by the Helmholtz free energy as a single-valued almost analytical function of the specific volume and temperature. The cold curve is taken to be of the MACAW form. The vibrational contribution to the Helmholtz free energy is described by a weighted sum of three Debye oscillators in the quasi-harmonic approximation. The calibration data suggests the range of reliable applicability of the EOS from the ambient conditions to temperatures of ∼ 3000 K and pressures of ∼ 50-70 GPa.

36 MATERIALS SCIENCE↗

2024 Milestone Report: Site 300 mPDV Optical Fiducials

In the early 2000s Photon Doppler Velocimetry (PDV) replaced the Fabry-Perot many beam system1 and has since become ubiquitous across dynamic experimental platforms to measure velocity and event times such as shock breakout, key variables for high pressure physics research. The advent of optically multiplexed oscilloscope channels to create multiplexed PDV (mPDV) increased portability and reduced price per data point. However, these advantages came with the cost of additional fielding complexity and thermally induced timing drift, which directly affects the ability to use PDV for high precision time measurement. Controlling the temperature or incorporating optical fiducials allows researchers to characterize, reduce, and correct this thermal drift in analysis. Our implemented optical fiducial or “timing marker” allows us to reduce thermal drift uncertainty from the 10s of nanoseconds down to the 100s of picoseconds with minimal added complexity to existing systems. The implementation of this timing marker normalizes uncertainty across optical delays, brings our facility cross timing into the sub nanosecond regime and lets us identify/study anomalies in our data. This improvement increases experiment reliability and quality enabling a new class of high precision experiments at S300.

42 ENGINEERING↗

Investigating the Vulnerabilities of the Direct Transfer Trip Scheme for Network Protector Units in the Secondary Networks of Electric Power Distribution Grids

Network protector units (NPUs) are crucial parts of the protection of secondary networks to effectively isolate faults occurring on the primary feeders. When a fault occurs on the primary feeder, there is a path of the fault current going through the service transformers that causes a negative flow of current on the NPU connected to the faulted feeder. Conventionally, NPUs rely on the direction of current with respect to the voltage to detect faults and make a correct trip decision. However, the conventional NPU logic does not allow the reverse power flow caused by distributed energy resources installed on secondary networks. The communication-assisted direct transfer trip logic for NPUs can be used to address this challenge. However, the communication-assisted scheme is exposed to some vulnerabilities arising from the disruption or corruption of the communicated data that can endanger the reliable operation of NPUs. This paper evaluates the impact of the malfunction of the communication system on the operation of communication-assisted NPU logic. To this end, the impact of packet modification and denial-of-service cyberattacks on the communication-assisted scheme are evaluated. The evaluation was performed using a hardware-in-the-loop (HIL) co-simulation testbed that includes both real-time power system and communication network digital simulators. This paper evaluates the impact of the cyberattacks for different fault scenarios and provides a list of recommendations to improve the reliability of communication-assisted NPU protection.

direct transfer trip↗

Defining and Measuring Forest Dependence in the United States: Operationalization and Sensitivity Analysis

This manuscript helps bridge a gap between theoretical work that advocates for a broad view of forest dependence, and empirical work that has focused narrowly on economic measures. Background: Forest dependence has been widely recognized as a valuable concept for understanding human communities’ well-being and vulnerability to shocks and changes. Past theoretical literature has highlighted the importance of recognizing various types of dependence—environmental, economic, and social—yet past empirical literature on the topic in the United States has almost exclusively relied on measures of economic dependence such as employment and earnings from the traditional forest products sector. Objective and Methods: As a first step to bridge the gap between the theoretical and empirical, we reviewed the existing, publicly available, reliable, wall-to-wall data sources to identify alternate proxy measures for forest dependence. Data availability made the analysis feasible only at the county level—the administrative subdivisions of the state—or higher. Results and Conclusions: We created environmental, economic, and social criteria based on threshold levels of the following proxy variables: forest area, earnings, employment, and indigenous population. Using these criteria, we identified 524 counties to be potentially forest-dependent of 3140 total counties in the United States. The largest concentration was in the Pacific Northwest and Southeast regions, and a higher proportion were non-metro counties than metro. Varying the threshold levels significantly changes the number of counties identified but does not alter the overall geographic trends.

54 ENVIRONMENTAL SCIENCES↗

Persistent, extensive channelized drainage modeled beneath Thwaites Glacier, West Antarctica

Abstract. Subglacial hydrology is a leading control on basal friction and the dynamics of glaciers and ice sheets. At low discharge, subglacial water flows through high-pressure, sheet-like systems that lead to low effective pressures. However, at high discharge, subglacial water melts the overlying ice into localized channels that efficiently remove water from the bed, thereby increasing effective pressure and basal friction. Recent observations suggest channelized subglacial flow exists beneath Thwaites Glacier, yet it remains unclear if stable channelization is feasible in West Antarctica, where surface melting is nonexistent and water at the bed is limited. Here, we use the MPAS-Albany Land Ice model to run a suite of over 130 subglacial hydrology simulations of Thwaites Glacier across a wide range of physical parameter choices to assess the likelihood of channelization. We then narrow our range of viable simulations by comparing modeled water thicknesses to previously observed radar specularity content, which indicates flat, spatially extensive water bodies at the bed. In all of our data-compatible simulations, stable channels reliably form within 100–200 km of the grounding line and reach individual discharge rates of 35–110 m3 s−1 at the ice–ocean boundary. While only one to two channels typically form across the 200 km width of the glacier in our simulations, their high efficiency drains water across the entire lateral extent of the glacier. We posit the large catchment size of Thwaites Glacier, its funnel-like geometry, and high basal melt rates together accumulate enough water to form stable channels. No simulations resembled observed specularity content when channelization was disabled. Our results suggest channelized subglacial hydrology has two consequences for Thwaites Glacier dynamics: (i) amplifying submarine melting of the terminus and ice shelf while (ii) simultaneously raising effective pressure within 100 km of the grounding line and increasing basal friction. The distribution of effective pressure implied from our modeling differs from parameterizations typically used in large-scale ice sheet models, suggesting the development of more process-based parameterizations may be necessary.

54 ENVIRONMENTAL SCIENCES↗

Betting on Floatovoltaics: Floating PV Opportunities in the U.S.

Join NREL for a presentation on early findings on the potential for floating PV development in the U.S, covering feasible regions in the U.S., sensitivity analysis of factors affecting LCOE, operational and economic co-benefits, climate factors and early data on system performance and reliability.

14 SOLAR ENERGY↗

Methods and systems for detection of man-in-the-middle attacks for SCADA communication networks and applications of same

A system for detecting MITM for SCADA communication networks includes secure substation-substation communication links for providing secure and reliable paths to exchange OT data between substations for OT data consistency check; a SIB in each substation for sampling CT and PT measurements to calculate voltage magnitude and phase angle thereof; a S&C server in each substation coupled to the SIB for receiving the voltage magnitude and phase angle from the SIB and obtaining a packet carrying active power flow in transmission lines between two substations and a time stamp; an IDS server placed in a SCADA center for collecting the packet of each substation sent by the S&C server; analyzing the received packet from every adjacent substation; inspecting the payload of the received packet; and triggering an intrusion alarm to a SCADA operator when the power flow is not the same as the payload of the packets.

McCann, Roy A.↗

Spatio-Temporal Denoising Graph Autoencoders with Data Augmentation for Missing Photovoltaic Data Imputation

The integration of the global Photovoltaic (PV) market with real time data-loggers has enabled large scale PV data analytical pipelines for power forecasting and long-term reliability assessment of PV fleets. Nevertheless, the performance of PV data analysis heavily depends on the quality of PV timeseries data. This paper proposes a novel Spatio-Temporal Denoising Graph Autoencoder (STD-GAE) framework to impute missing PV Power Data. STDGAE exploits temporal correlation, spatial coherence, and value dependencies from domain knowledge to recover missing data. It is empowered by two modules. (1) To cope with sparse yet various scenarios of missing data, STD-GAE incorporates a domain-knowledge aware data augmentation module that creates plausible variations of missing data patterns. This generalizes STD-GAE to robust imputation over different seasons and environment. (2) STD-GAE nontrivially integrates spatiotemporal graph convolution layers (to recover local missing data by observed “neighboring” PV plants) and denoising autoencoder (to recover corrupted data from augmented counterpart) to improve the accuracy of imputation accuracy at PV fleet level. We have evaluated our proposed model on two realworld PV datasets. Experimental results show that STD-GAE can achieve a gain of 43.14% in imputation accuracy and remains less sensitive to missing rate, different seasons, and missing scenarios, compared with state-of-the-art data imputation methods such as MIDA and LRTC-TNN.

Fan, Yangxin↗

TMS 2023 - Methodology and Density of PuCl3-NaCl Mixtures

The development of molten salt reactors and their associated components demands reliable and accurate thermophysical property data for design and validation. A candidate fuel salt, PuCl3-NaCl (36 mol% PuCl3) has been synthesized and studied at the Idaho National Laboratory. This study has determined the density of PuCl3-NaCl at multiple compositions and temperatures, providing data for validation of modeling efforts and making improvements on the buoyancy method for density measurements of actinide-bearing molten salts.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

IEA PVPS Task 13 Techno-Economic Study of Bifacial Photovoltaic Systems on Single Axis Trackers

The International Energy Agency PVPS Task 13 has assembled an international team of photovoltaic (PV) researchers from government labs, academia, and industry to study the specific application of bifacial PV modules deployed on tracking systems. This configuration is of particular interest as it has been identified as the PV system design with the lowest Levelized Cost of Electricity (LCOE) for over 90% of the world [1]. As such, much research, development, and commercial activity are focused on further optimizing this system design for different regions and markets, including field deployment and advanced modeling activities. Despite these efforts, many challenges remain to overcome with this system design. This conference paper will report on several areas the team is working on as part of this project. The first part of this study focuses on extensive interviews with PV tracker companies (we have identified 35) and customers worldwide to identify emerging technology trends, design diversity, market environments, and the reliability and performance of these systems. We will provide a market summary of technologies such as advanced tracking algorithms, methods for dealing with topography within the PV plant, different system configurations and layouts, backside irradiance optimization from albedo enhancement, and ground sculpting. We will also review dual-use applications of tracked bifacial systems, such as Agrivoltaics and Building-Integrated PV. These interviews are underway now, and we will be able to report our initial findings at the conference. The second part of the study focuses on summarizing performance monitoring and evaluation methods, with particular attention to capacity and acceptance testing for such systems. The third part of the study reviews performance modeling and yield assessment methods for these tracked bifacial PV systems. The final part of the study covers reliability and operations, and maintenance data from these systems.

albedo↗

Tool-Based Case Studies on Strategic Deployment of Untapped Micro-Pumped Hydro Storage in Michigan

With most classical hydropower sites already utilized and the global push for rapid integration of renewable energy sources accelerating, there is a critical need to identify alternative energy storage solutions. Pumped hydro energy storage, which accounts for the vast majority of global grid-scale storage, remains one of the most cost-effective and long-duration storage technologies available. Hence, this study presents a novel tool designed to assess the untapped potential of inland lakes and reservoirs for micro-PSH, using Michigan’s relatively flat landscape as a case study due to its extensive but underutilized water infrastructure. To ensure accuracy and reliability, the tool incorporates extensive data gathered from authorized sources, covering more than 420 water facilities and potential reservoirs in the state. The tool evaluates key parameters such as horizontal and vertical distances, volume, and the total storage capacity of each reservoir. Its robust assessment framework integrates these metrics to evaluate each site’s potential. The tool’s intuitive interface and geospatial visualizations support actionable insights for planners and scalable deployment of distributed storage infrastructure.

13 HYDRO ENERGY↗

Measurement of the galaxy-velocity power spectrum of DESI tracers with the kinematic Sunyaev-Zeldovich effect using DESI DR2 and ACT DR6

Joint analyses of high-resolution CMB temperature maps with galaxy surveys provide a unique way to reconstruct the radial velocity field of the underlying matter distribution via the kinematic Sunyaev-Zeldovich (kSZ) effect. Using data from the Atacama Cosmology Telescope (ACT) DR6 and the Dark Energy Spectroscopic Instrument (DESI) DR2, we present radial velocity reconstructions for luminous red galaxies (LRGs), emission-line galaxies (ELGs), and quasars (QSOs). Leveraging the spectroscopic data, we are able to reliably model the foreground contamination and report a negligible impact on our main observables. We detect the velocity-galaxy cross-correlation at $17.0σ$ for LRGs, and for the first time, at $8.3σ$ for ELGs and $6.8σ$ for QSOs. We further report the first detection of the velocity-velocity correlation using LRGs at $3.1σ$, as well as the highest cumulative detection of the kSZ effect to date at $20.8 σ$. Similarly to previous results, we find a lower amplitude of the kSZ signal compared to our fiducial halo model prediction and electron profile assuming a Battaglia profile. Combining these new observables, we obtain constraints on local-type primordial non-Gaussianity (PNG): $f_{\rm NL}^{\rm loc} = 15.9_{-34.4}^{+34.6}$ at 68% confidence, which represents the tightest constraint to date derived from the velocity field. The measurements presented here already exhibit lower noise on a per-mode basis than the galaxy auto-correlation on the largest scales, $k<0.004~\rm{Mpc^{-1}}$, highlighting the key role these observables will play in the context of future CMB experiments such as the Simons Observatory.

Chaussidon, Edmond [LBL, Berkeley] (ORCID:00000001↗

Sizing ramping reserve using probabilistic solar forecasts: A data-driven method

Ramping products have been introduced or proposed in several U.S. power markets to mitigate the impact of load and renewable uncertainties on market efficiency and reliability. Current methods often rely on historical data to estimate the requirements of ramping products and fail to take into account the effects of the latest weather conditions and their uncertainties, which could lead to overly conservative or insufficient requirements. This study proposes a k-nearest-neighbor-based method to give weather-informed estimates of ramping needs based on short-term probabilistic solar irradiance forecasts. Forecasts from multiple sites are employed in conjunction with principal component analysis to derive numerical classifiers to characterize system-level weather conditions. In addition, we develop a data-driven method to optimize the model parameters in a rolling-forward manner. By using real-world data from the California Independent System Operator, we design two metrics to evaluate method performance: 1) frequency of shortage and 2) oversupply of ramping product. Our proposed method presents advantages in comparison with the baseline and a set of benchmark methods: without compromising system reliability, it reduces system ramping requirements by up to 25%, therefore improving both system reliability and economics.

14 SOLAR ENERGY↗

Reliability of emergency and standby diesel generators: Impact on energy resiliency solutions

Emergency diesel generators are the most common form of backup power for critical loads when the grid fails and are most often deployed as stand-alone generators (<2000 kW) tied to individual buildings for hospitals, emergency services, military bases, ports, airports, industries, and commercial facilities. Understanding the finite reliability of emergency diesel generators during continuous operation is critical for energy planners, managers, and end-users. A new analysis of two large non-public emergency diesel generator operational data sets shows that commonly used reliability metrics are inadequate to predict the performance during a grid outage. Additional metrics addressing the likelihood of an emergency diesel generator to be available at the time an outage starts, successfully start and carry load, and constantly run for the duration of the outage are needed to predict the continuous run-time reliability of emergency diesel generators during a grid outage. This is the first analysis of the reliability of modern generators that follow standard maintenance protocols commonly used for backup power and these new metrics are shown to be dependent on the level of emergency diesel generator maintenance with values that can vary by more than an order of magnitude. Even using the new metrics for well-maintained emergency diesel generators, the analysis shows that the single emergency diesel generators configurations are only 80% likely to provide power for the duration of a two-week grid outage.

ENERGY PLANNING, POLICY, AND ECONOMY,POWER TRANSMI↗

Next-Level Energy Management in Manufacturing: Facility-Level Energy Digital Twin Framework Based on Machine Learning and Automated Data Collection

This research introduces an energy prediction framework at the facility level supported by automated data collection and machine learning models. It investigates whether reducing the prediction time scale allows for applying more complex machine learning techniques and if those techniques improve the prediction accuracy. The primary advantages of this framework lie in its automation of the energy prediction process and its provision of real-time energy data suitable for use in energy dashboards or digital twins. A sitewide dataset was created by combining 15 min energy and daily production data of five shops—assembly, battery, body (electric), body (gas), and paint—from a globally recognized electric vehicle manufacturer. Various machine learning models were evaluated on daily, weekly, and monthly datasets, including, in increasingly complex order: naïve, simple linear regression, net regularized generalized linear regression, principal component regression, k-nearest neighbor, random forest, and Bayesian regularized neural network. Compared to the current state-of-the-art energy consumption prediction for the industrial facility level, this research investigates more complex models and smaller time intervals for higher accuracy. The findings revealed that the more complex monthly models require a minimum of a year and a half of data to operate, while weekly models demand a year of data to achieve improved accuracy. Daily models can operate with only six months of data but exhibit poor performance due to reduced prediction accuracy of production. Key challenges identified include access to reliable, high-quality energy and production data and the initial demand for human labor.

digital twin↗

Roadmap and Benchmarking: Privacy in Federated Load Forecasting

Data-driven techniques for energy demand forecasting continue to emerge with promising impacts on distribution grid planning. However, the development of robust and generalizable machine learning models requires that representative high quality training data are available. Distributed energy resources have begun to embed intelligence, gathering large amounts of data on customer demand, behavior, and household devices that are connected to the grid. Though utilities aggregate meter-level demand data for load shaping, demand response, outage management, reliability planning, and billing applications, there lies an inherent privacy concern in sharing consumption data that may identify individual consumer behavioral patterns. Hence, while sharing the data is crucial, the private sensitive customer data must be safeguarded from being exposed or manipulated. In this study, we propose a roadmap for implementing a based privacy preserving framework to support the advancement of data-driven analytics in data-sensitive distributed energy resources environments. The roadmap incorporates federated learning–a distributed training framework, differential privacy–a statistical framework that provides guarantees to safeguard the leakage of sensitive data, secure multiparty computation and homomorphic encryption– techniques for encrypting model gradients and applying secure aggregation on the server. Moreover, we perform baseline experiments on the federated short-term load forecasting (STLF) task using open-source residential load profile datasets, offering insights into the challenges of integrating differential privacy into federated learning.

Abebe, Waqwoya [Oak Ridge National Laboratory (ORN↗

Measurement of Beam Energy in the Fermilab&#x27;s Linac taken at the transfer Line

Linac is the first machine in the Accelerator chain at Fermilab where 𝐻− particles are accelerated from 35 keV to 400 MeV and travel to the Booster where they are stripped. of the extra electrons to become protons. The Booster requires stable beam energy at injection. The Linac extraction energy tuning has been performed using two Beam Velocity Monitors (a.k.a Griffin detectors) to maintain stable relative energy between the Booster and the Linac. Our goal is to control the Linac energy parameters using Machine Learning techniques to increase reliability and quality of beam delivered from Linac. The first step is to understand the data from the Linac extraction diagnostics; and develop reliable, accurate methods for energy measurement and control before implementing machine learning. There were two methods of energy measurement implemented, and the results of these are compared. The first method was time of flight measurements using the Phase probes inside B eam Position Monitors (BPM) that provide the beam’s phase of arrival data. The second method used the relation between beam position data from the BPMs and dispersion values from the 400MeV MAD-X model to calculate momentum variation. The results of these two energy measurement methods compare well as the Linac energy is varied.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fast and Accurate Frequency Response Estimation for Large Power System Disturbances Using Second Derivative of Frequency Data

Accurate Frequency Response Estimation (FRE) is critical to reliability risk management of large power system disturbances. This letter proposes a measurement-driven approach for FRE by calculating the second derivative of frequency from synchrophasor data. Compared with conventional methods, the proposed method has major advantages of low computational burden and high accuracy, which makes it appropriate for real-time FRE in bulk power systems. The effectiveness of this method is validated with actual synchrophasor data on 96 confirmed historical power system disturbances in the U.S. eastern interconnection.

24 POWER TRANSMISSION AND DISTRIBUTION↗