Search NASA⌕ Search

SEARCH · Search NASA

Results for “defect imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Infrared vibrational nano-crystallography and nano-imaging

Molecular solids and polymers can form low-symmetry crystal structures that exhibit anisotropic electron and ion mobility in engineered devices or biological systems. The distribution of molecular orientation and disorder then controls the macroscopic material response, yet it is difficult to image with conventional techniques on the nanoscale. We demonstrated a new form of optical nanocrystallography that combines scattering-type scanning near-field optical microscopy with both optical antenna and tip-selective infrared vibrational spectroscopy. From the symmetry-selective probing of molecular bond orientation with nanometer spatial resolution, we determined crystalline phases and orientation in aggregates and films of the organic electronic material perylenetetracarboxylic dianhydride. Mapping disorder within and between individual nanoscale domains, the correlative hybrid imaging of nanoscale heterogeneity provides insight into defect formation and propagation during growth in functional molecular solids.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Spatially resolved characterization of optical and recombination losses for different industrial silicon solar cell architectures

In this work, spatially resolved characterization methods are used to identify loss mechanisms for common p -type silicon solar cell architectures, including multicrystalline aluminum back surface field (Al-BSF), monocrystalline Al-BSF, monocrystalline passivated emitter and rear cells (PERC), and bifacial monocrystalline PERC. The characterization methods used in this work include suns-V OC , photoluminescence imaging, and spatially resolved external quantum efficiency and reflectance measurements. The optical and recombination losses are driven by the material properties, cell processing conditions, and device architecture. These losses are quantified and categorized in terms of underlying mechanisms (e.g., front reflectance, escape reflectance, front recombination, and parasitic optical absorption and recombination in the bulk and rear). The ability to create images of these loss parameters can be used to gain more insight into the materials and manufacturing processes used to produce solar cells, and examples are given in this work to illustrate how these images can help reveal the origin of defects.

14 SOLAR ENERGY↗

Electronic Properties of Carbon Nanotubes and Junctions

Metallic and semiconducting Single Wall Carbon Nanotubes (CNT) have recently been characterized using scanning tunneling microscopy (STM) and the manipulation of individual CNT has been demonstrated. These developments make the prospect of using CNT as molecular wires and possibly as electronic devices an even more interesting one. We have been modeling various electronic properties such as the density of states and the transmission coefficient of CNT wires and junctions. These studies involve first calculating the stability of junctions using molecular dynamics simulations and then calculating the electronic properties using a pi-electron tight binding Hamiltonian. We have developed the expertise to calculate the electronic properties of both finite-sized CNT and CNT systems with semi-infinite boundary conditions. In this poster, we will present an overview of some of our results. The electronic application of CNT that is most promising at this time is their use as molecular wires. The conductance can however be greatly reduced because of reflection due to defects and contacts. We have modeled the transmission through CNT in the presence of two types of defects: weak uniform disorder and strong isolated scatterers. We find that the conductance is affected in significantly different manners due to these defects Junctions of CNT have also been imaged using STM. This makes it essential to derive rules for the formation of junctions between tubes of different chirality, study their relative energies and electronic properties. We have generalized the rules for connecting two different CNT and have calculated the transmission and density of states through CNT junctions. Metallic and semiconducting CNT can be joined to form a stable junction and their current versus voltage characteristics are asymmetric. CNT are deformed by the application of external forces including interactions with a substrate or other CNT. In many experiments, these deformation are expected to occur naturally. We will present some preliminary results of our calculations of the modification of CNT electronic properties as a result of deformations.

Anantram, M. P.↗

Real Time Fatigue Damage Growth Assessment of a Composite Three-Stringer Panel Using Passive Thermography

Fatigue testing of advanced composite structures is critical to validate both structural designs and damage prediction models. In-situ inspection methods are necessary to track damage onset and growth as a function of load cycles. Passive thermography is a large area, noncontact inspection technique that is used to detect composite damage onset and growth in real time as a function of fatigue cycles. The thermal images are acquired in synchronicity to the applied compressive load using a dual infrared camera acquisition system for full (front and back) coverage. Image processing algorithms are investigated to increase defect contrast areas. The thermal results are compared to non-immersion ultrasound inspections and acoustic emission data.

Zalameda, Joseph N.↗

Recovery Act: Multimodal Imaging for Solar Cell Microcrack Detection

Undetected microcracks in solar cells are a principal cause of failure in service due to subsequent weather exposure, mechanical flexing or diurnal temperature cycles. Existing methods have not been able to detect cracks early enough in the production cycle to prevent inadvertent shipment to customers. This program, sponsored under the DOE Photovoltaic Supply Chain and Cross-Cutting Technologies program, studied the feasibility of quantifying surface micro-discontinuities by use of a novel technique, thermoreflectance imaging, to detect surface temperature gradients with very high spatial resolution, in combination with a suite of conventional imaging methods such as electroluminescence. The project carried out laboratory tests together with computational image analyses using sample solar cells with known defects supplied by industry sources or DOE National Labs. Quantitative comparisons between the effectiveness of the new technique and conventional methods were determined in terms of the smallest detectable crack. Also the robustness of the new technique for reliable microcrack detection was determined at various stages of processing such as before and after antireflectance treatments. An overall assessment is that the new technique compares favorably with existing methods such as lock-in thermography or ultrasonics. The project was 100% completed in Sept, 2010. A detailed report of key findings from this program was published as: Q.Zhou, X.Hu, K.Al-Hemyari, K.McCarthy, L.Domash and J.Hudgings, High spatial resolution characterization of silicon solar cells using thermoreflectance imaging, J. Appl. Phys, 110, 053108 (2011).

14 SOLAR ENERGY↗

Simulation Study of High-Precision Characterization of MeV Electron Interactions for Advanced Nano-Imaging of Thick Biological Samples and Microchips

The resolution of a mega-electron-volt scanning transmission electron microscope (MeV-STEM) is primarily governed by the properties of the incident electron beam and angular broadening effects that occur within thick biological samples and microchips. A precise understanding and mitigation of these constraints require detailed knowledge of beam emittance, aberrations in the STEM column optics, and energy-dependent elastic and inelastic critical angles of the materials being examined. This simulation study proposes a standardized experimental framework for comprehensively assessing beam intensity, divergence, and size at the sample exit. This framework aims to characterize electron-sample interactions, reconcile discrepancies among analytical models, and validate Monte Carlo (MC) simulations for enhanced predictive accuracy. Our numerical findings demonstrate that precise measurements of these parameters, especially angular broadening, are not only feasible but also essential for optimizing imaging resolution in thick biological samples and microchips. By utilizing an electron source with minimal emittance and tailored beam characteristics, along with amorphous ice and silicon samples as biological proxies and microchip materials, this research seeks to optimize electron beam energy by focusing on parameters to improve the resolution in MeV-STEM/TEM. This optimization is particularly crucial for in situ imaging of thick biological samples and for examining microchip defects with nanometer resolutions. Our ultimate goal is to develop a comprehensive mapping of the minimum electron energy required to achieve a nanoscale resolution, taking into account variations in sample thickness, composition, and imaging mode.

36 MATERIALS SCIENCE↗

Describing Point Defect Topology in 2D Energy Materials Through Computer Vision

Point defects such as vacancies and impurity atoms strongly impact the performance of 2D materials. Traditional efforts often rely on manual detection, a process that is time-intensive, prone to human error, and challenging to scale. Here we leverage machine learning (ML) methods to identify and quantify vacancies within 2D transition metal carbides (Ti3C2, MXenes), aiming to expedite detection while improving accuracy. MXenes exhibit valuable defect-defined electrochemical properties, but we currently lack statistical understanding of defect topology needed to fully harness these materials. We employ a convolutional neural network for semantic segmentation of experimental MXene images, opening an opportunity to conduct a rigorous statistical study on defect hierarchy while investigating local relaxation in the lattice. We show how the integration of ML can yield fundamental insight into point defects, providing a powerful tool that will play an increasingly crucial role in the future of materials science.

2D materials↗

Modeling of the Multiparameter Inverse Task of Transient Thermography

Transient thermography employs preheated surface temperature variations caused by delaminations, cracks, voids, corroded regions, etc. Often, it is enough to detect these changes to declare a defect in a workpiece. It is also desirable to obtain additional information about the defect from the thermal response. The planar size, depth, and thermal resistance of the detected defects are the parameters of interest. In this paper a digital image processing technique is applied to simulated thermal responses in order to obtain the geometry of the inclusion-type defects in a flat panel. A three-dimensional finite difference model in Cartesian coordinates is used for the numerical simulations. Typical physical properties of polymer graphite composites are assumed. Using different informative parameters of the thermal response for depth estimation is discussed.

Plotnikov, Y. A.↗

DETERMINATION OF STRUT QUALITY FACTORS IN ADDITIVELY MANUFACTURED LATTICES USING IN-SITU COMPRESSION TESTING µ-CT

In response to the need for an automated, commercial method to qualify additively manufactured (AM) lattice components, an experiment was conducted to evaluate the effects of defective lattice struts on the structural compression strength. Lattice samples with known defective or missing struts were compressed using a Deben CT5000RT and imaged using xray µ-CT. The compressive force and x-ray computed tomography results were compared to defect free standards to evaluate the impact of each defect type on the overall structure’s compressive strength. This analysis will allow for simplifications to Finite Element Analysis (FEA) on AM parts without sacrificing model fidelity. Understanding the contribution of each defect type and severity will also better inform non-destructive evaluation (NDE) personnel of the inspection parameters necessary to detect the smallest feature of importance.

Dinova, Vincent A.↗

Non-Uniformities in Thin-Film Cadmium Telluride Solar Cells Using Electroluminescence and Photoluminescence: Preprint

It is the purpose of this research to develop specific imaging techniques that have the potential to be fast, in-line tools for quality control in thin-film CdTe solar cells. Electroluminescence (EL) and photoluminescence (PL) are two techniques that are currently under investigation on CdTe small area devices made at Colorado State University. It is our hope to significantly advance theunderstanding of EL and PL measurements as applied to CdTe. Qualitative analysis of defects and non-uniformities is underway on CdTe using EL, PL, and other imaging techniques.

14 SOLAR ENERGY↗

High-Resolution Thermal Profiling of a High-Power Diode Laser Facet During Aging

Here, we study the facet temperature distribution of a high-power diode laser over its lifetime using a noncontact, high spatial resolution CCD-based thermoreflectance technique. Based on the known correlation between non-radiative defects and heating, thermal maps can provide valuable information regarding the formation and evolution of small point defects that are at or near the facet during aging. In the laser under study in this work we measure the appearance of local hot spots on the facet, including concentrated hot spots that appear just before or just after COD and are correlated with loss of local light emission. The locations of these hot spots do not exhibit morphology changes in high-resolution SEM imaging of the facet, indicating that the related defects are too small to be observable in SEM or are located at some depth under the facet. Prior to COD, we measure a gradual facet temperature increase accompanied by a gradual optical power decrease and gradual facet optical absorption increase, indicating gradual degradation of the laser.

47 OTHER INSTRUMENTATION↗

Phase Contrast X-ray Imaging of Shuttle Insulating Foam

X-ray radiation has been widely used for imaging applications since Rontgen first discovered X-rays over a century ago. Its large penetration depth makes it ideal for the nondestructive visualization of internal structure of materials or objects unobtainable otherwise. Currently widely used nondestructive evaluation (NDE) tools-X-ray radiography and tomography are absorption-based, and work well in highly absorbing materials where density or composition variations due to internal structure or defects are high enough to be spatially distinguished in terms of absorption contrast. However, in many cases where materials such as insulating foam are light-weight, the conventional absorption-based X-ray methods for NDE become less effective. Indeed, the low-density shuttle insulating foam used for flight mission poses a great challenge to the standard NDE tools in that the absorption contrast arising from internal defects of such a low- density material is either weak or indistinguishable. In this presentation, the latest progress in phase contrast X-ray imaging of internal defects of insulating foam will be presented and discussed, demonstrating new opportunities to solve challenging issues involved in advanced materials development and processing for space exploration.

Hu, Zhengwei↗

SU-E-T-04: 3D Dose Based Patient Compensator QA Procedure for Proton Radiotherapy

Purpose: In proton double-scattering radiotherapy, compensators are the essential patient specific devices to contour the distal dose distribution to the tumor target. Traditional compensator QA is limited to checking the drilled surface profiles against the plan. In our work, a compensator QA process was established that assess the entire compensator including its internal structure for patient 3D dose verification. Methods: The fabricated patient compensators were CT scanned. Through mathematical image processing and geometric transformations, the CT images of the proton compensator were combined with the patient simulation CT images into a new series of CT images, in which the imaged compensator is placed at the planned location along the corresponding beam line. The new CT images were input into the Eclipse treatment planning system. The original plan was calculated to the combined CT image series without the plan compensator. The newly computed patient 3D dose from the combined patientcompensator images was verified against the original plan dose. Test plans include the compensators with defects intentionally created inside the fabricated compensators. Results: The calculated 3D dose with the combined compensator and patient CT images reflects the impact of the fabricated compensator to the patient. For the test cases in which no defects were created, the dose distributions were in agreement between our method and the corresponding original plans. For the compensator with the defects, the purposely changed material and a purposely created internal defect were successfully detected while not possible with just the traditional compensator profiles detection methods. Conclusion: We present here a 3D dose verification process to qualify the fabricated proton double-scattering compensator. Such compensator detection process assesses the patient 3D impact of the fabricated compensator surface profile as well as the compensator internal material and structure changes. This research receives funding support from CURA Medical Technologies.

60 APPLIED LIFE SCIENCES↗

Defect structure of EFG silicon ribbon

The defect structure of EFG ribbons was studied using EBIC, TEM and HVEM. By imaging the same areas in EBIC and HVEM, a direct correlation between the crystallographic nature of defects and their electrical properties was obtained. (1) Partial dislocations at coherent twin boundaries may or may not be electrically active. Since no microprecipitates were observed at these dislocations it is likely that the different electrical activity is a consequence of the different dislocation core structures. (2) 2nd order twin joins were observed which followed the same direction as the coherent first order twins normally associated with EFG ribbons. These 2nd order twin joins are in all cases strongly electrically active. EFG ribbons contain high concentrations of carbon. Since no evidence of precipitation was found with TEM it is suggested that the carbon may be incorporated into the higher order twin boundaries now known to exist in EFG ribbons.

Strunk, H.↗

Actinic characterization of EUV bump-type phase defects

Despite tremendous progress and learning with EUV lithography, quantitative experimental information about the severity of point-like phase defects remains in short supply. We present a study of measured, EUV aerial images from a series of well-characterized, open-field, bump-type programmed phase defects, created on a substrate before multilayer deposition.

36 MATERIALS SCIENCE↗

Vision-based inspection of prefabricated components using camera poses: Addressing inherent limitations of image-based 3D reconstruction

Modular construction can lead to additional cost overruns and delays when a defect is found on the construction site and is not easily repairable. Researchers have developed various methods that use image-based 3D reconstruction for quality assessment, but they have inherent limitations, such as inconsistency and dealing with surfaces with reflectivity and limited visual features. Therefore, this paper presents a vision-based quality assessment method using cameras for prefabricated components by addressing these limitations. Specifically, this paper proposes a novel quality inspection method with sub-millimeter accuracy using cameras focused on leveraging camera poses (as opposed to 3D point clouds that are often not consistent in quality) from the image-based 3D reconstruction. The 3D point estimation by computing triangulation was used for achieving accurate measurement. The proposed method is validated using six different variances and two case studies – an aluminum pipe with a reflective surface and a fabricated concrete column. Furthermore, the results demonstrate the accuracy and effectiveness of the proposed method.

42 ENGINEERING↗

The self-healing of defects induced by the hydriding phase transformation in palladium nanoparticles

Nanosizing can dramatically alter material properties by enhancing surface thermodynamic contributions, shortening diffusion lengths, and increasing the number of catalytically active sites per unit volume. These mechanisms have been used to explain the improved properties of catalysts, battery materials, plasmonic materials, etc. Here we show that Pd nanoparticles also have the ability to self-heal defects in their crystal structures. Using Bragg coherent diffractive imaging, we image dislocations nucleated deep in a Pd nanoparticle during the forward hydriding phase transformation that heal during the reverse transformation, despite the region surrounding the dislocations remaining in the hydrogen-poor phase. We show that defective Pd nanoparticles exhibit sloped isotherms, indicating that defects act as additional barriers to the phase transformation. Our results resolve the formation and healing of structural defects during phase transformations at the single nanoparticle level and offer an additional perspective as to how and why nanoparticles differ from their bulk counterparts.

36 MATERIALS SCIENCE↗

Describing Point Defect Topology in 2D Energy Materials through Computer Vision

Point defects such as vacancies and impurity atoms strongly impact the performance of 2D materials. Traditional efforts often rely on manual detection, a process that is time-intensive, prone to human error, and challenging to scale. Here we leverage machine learning (ML) methods to identify and quantify vacancies within 2D transition metal carbides (Ti3C2, MXenes), aiming to expedite detection while improving accuracy. MXenes exhibit valuable defect-defined electrochemical properties, but we currently lack statistical understanding of defect topology needed to fully harness these materials. Here we employ a convolutional neural network for semantic segmentation of experimental MXene images, opening an opportunity to conduct a rigorous statistical study on defect hierarchy while investigating local relaxation in the lattice. We show how the integration of ML can yield fundamental insight into point defects, providing a powerful tool that will play an increasingly crucial role in the future of materials science.

2d materials↗