Search NASA⌕ Search

SEARCH · Search NASA

Results for “deployed optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

BOREAS RSS-3 Atmospheric Measurements from a Helicopter-Mounted Sunphotometer

The BOREAS RSS-3 team collected and processed helicopter-based measurements of atmospheric conditions to estimates of aerosol optical thickness and atmospheric water vapor. The automatic sun-tracking photometer for helicopters was deployed during all three 1994 IFCs at numerous tower and auxiliary sites in both the NSA and the SSA. Six spectral channels (440, 540, 613, 670, 870, and 1030 nm) were chosen to span the visible and NIR wavelengths and to avoid gaseous absorption. One additional channel, 940 nm, was selected to measure the water column abundance above the helicopter platform. The data are stored in tabular ASCII files.

Hall, Forrest G.↗

NASA Langley Airborne High Spectral Resolution Lidar Instrument Description

NASA Langley Research Center (LaRC) recently developed the LaRC Airborne High Spectral Resolution Lidar (HSRL) to make measurements of aerosol and cloud distribution and optical properties. The Airborne HSRL has undergone as series of test flights and was successfully deployed on the Megacity Initiative: Local and Global Research Observations (MILAGRO) field mission in March 2006 (see Hair et al. in these proceedings). This paper provides an overview of the design of the Airborne HSRL and descriptions of some key subsystems unique to this instrument.

Harper, David B.↗

Recent Developments in the Alignment and Test Plans for the James Webb Space Telescope Integrated Science Instrument Module

The James Webb Space Telescope (JWST) is a 6.6m diameter, segmented, deployable telescope for cryogenic IR space astronomy (approximately 40K). The JWST Observatory architecture includes the Optical Telescope Element (OTE) and the Integrated Science Instrument Module (ISIM) element that contains four science instruments (SI) including a Guider. The SIs and Guider are mounted to a composite metering structure with outer dimensions of 2.1 x 2.2 x 1.9m. The SI and Guider units are integrated to the ISIM structure and optically tested at NASA/Goddard Space Flight Center as an instrument suite using an OTE SIMulator (OSIM). OSIM is a high-fidelity, cryogenic JWST telescope simulator that features a approximately 1.5m diameter powered mirror. The SIs are aligned to the structure's coordinate system under ambient, clean room conditions using laser tracker and theodolite metrology. Temperature-induced mechanical SI alignment and structural changes are measured using a photogrammetric measurement system at ambient and cryogenic temperatures. OSIM is aligned to the ISIM mechanical coordinate system at the cryogenic operating temperature via internal mechanisms and feedback from alignment sensors in six degrees of freedom. SI performance, including focus, pupil shear and wavefront error, is evaluated at the operating temperature using OSIM. We present an updated plan for the assembly and ambient and cryogenic optical alignment, test and verification of the ISIM element.

Ohl, Raymond↗

Photogrammetric Metrology for the James Webb Space Telescope Integrated Science Instrument Module

The James Webb Space Telescope (JWST) is a 6.6m diameter, segmented, deployable telescope for cryogenic IR space astronomy (approximately 40K). The JWST Observatory architecture includes the Optical Telescope Element and the Integrated Science Instrument Module (ISIM) element that contains four science instruments (SI) including a Guider. The ISM optical metering structure is a roughly 2.2x1.7x2.2m, asymmetric frame that is composed of carbon fiber and resin tubes bonded to invar end fittings and composite gussets and clips. The structure supports the SIs, isolates the SIs from the OTE, and supports thermal and electrical subsystems. The structure is attached to the OTE structure via strut-like kinematic mounts. The ISIM structure must meet its requirements at the approximately 40K cryogenic operating temperature. The SIs are aligned to the structure's coordinate system under ambient, clean room conditions using laser tracker and theodolite metrology. The ISIM structure is thermally cycled for stress relief and in order to measure temperature-induced mechanical, structural changes. These ambient-to-cryogenic changes in the alignment of SI and OTE-related interfaces are an important component in the JWST Observatory alignment plan and must be verified. We report on the planning for and preliminary testing of a cryogenic metrology system for ISIM based on photogrammetry. Photogrammetry is the measurement of the location of custom targets via triangulation using images obtained at a suite of digital camera locations and orientations. We describe metrology system requirements, plans, and ambient photogrammetric measurements of a mock-up of the ISIM structure to design targeting and obtain resolution estimates. We compare these measurements with those taken from a well known ambient metrology system, namely, the Leica laser tracker system. We also describe the data reduction algorithm planned to interpret cryogenic data from the Flight structure. Photogrammetry was selected from an informal trade study of cryogenic metrology systems because its resolution meets sub-allocations to ISIM alignment requirements and it is a non-contact method that can in principle measure six degrees of freedom changes in target location. In addition, photogrammetry targets can be readily related to targets used for ambient surveys of the structure. By thermally isolating the photogrammetry camera during testing, metrology can be performed in situ during thermal cycling. Photogrammetry also has a small but significant cryogenic heritage in astronomical instrumentation metrology. It was used to validate the displacement/deformation predictions of the reflectors and the feed horns during thermal/vacuum testing (90K) for the Microwave Anisotropy Probe (MAP). It also was used during thermal vacuum testing (100K) to verify shape and component alignment at operational temperature of the High Gain Antenna for New Horizons. With tighter alignment requirements and lower operating temperatures than the aforementioned observatories, ISIM presents new challenges in the development of this metrology system.

Nowak, Maria↗

Advances in Measuring the Apparent Optical Properties (AOPs) of Optically Complex Waters

This report documents new technology used to measure the apparent optical properties (AOPs) of optically complex waters. The principal objective is to be prepared for the launch of next-generation ocean color satellites with the most capable commercial off-the-shelf (COTS) instrumentation. An enhanced COTS radiometer was the starting point for designing and testing the new sensors. The follow-on steps were to apply the lessons learned towards a new in-water profiler based on a kite-shaped backplane for mounting the light sensors. The next level of sophistication involved evaluating new radiometers emerging from a development activity based on so-called microradiometers. The exploitation of microradiometers resulted in an in-water profiling system, which includes a sensor networking capability to control ancillary sensors like a shadowband or global positioning system (GPS) device. A principal advantage of microradiometers is their flexibility in producing, interconnecting, and maintaining instruments. The full problem set for collecting sea-truth data--whether in coastal waters or the open ocean-- involves other aspects of data collection that were improved for instruments measuring both AOPs and inherent optical properties (IOPs), if the uncertainty budget is to be minimized. New capabilities associated with deploying solar references were developed as well as a compact solution for recovering in-water instrument systems from small boats.

Morrow, John H.↗

Active Thermal Architecture for Cryogenic Optical Instrumentation (ATACOI)

The Active Thermal Architecture for Cryogenic Optical Instrumentation (ATACOI) project will demonstrate an advanced thermal control system for CubeSats and enable the use of cryogenic electro-optical instrumentation on small satellite platforms. Specifically, the project focuses on the development of a deployable solar tracking radiator, a rotationally flexible rotary union fluid joint, and a thermal/vibrational isolation system for miniature cryogenic detectors. This technology will represent a significant improvement over the current state of the art for CubeSat thermal control, which generally relies on simple passive and conductive methods.

small spacecraft↗

Optimal Transport Based Control of Granular Imaging System in Space

"Orbiting Rainbows” is a paradigm for creating a space-based observatory (telescope) from confined and aligned granular media. The overall objective is to construct a very large and lightweight aperture in space using a cloud of micron-sized particles held in position and aligned by the application of external electromagnetic fields, thus alleviating the extreme expense of deploying and stabilizing large monolithic telescopes by reducing the mass of the primary aperture. Adaptive optics techniques for wavefront stabilization and computational imaging techniques are then used to remove the optical noise from the scattering reflections of the granular medium, and finally producing clean images within the diffraction limit. In this paper, we address one of the key challenges of this new paradigm, namely controlling the position and orientation of the granules or particles so that the cloud of particles achieves the desired shape of an ultra-lightweight telescope and points into the right orientation. A further complication arises due to the fact that the particles do not have any onboard actuators. A number of external electric-field-based actuators are used to control all the particles simultaneously. Moreover, the number of actuators are orders-of-magnitude smaller than the number of particles, making this system largely under-actuated. Since the cloud of particles in any plausible configuration can be modeled as a probability distribution over the workspace, we formulate this control challenge as an optimal transport problem and then show that our optimal transport based control law drives the cloud of particles from any initial distribution to the desired position distribution (optical surface) and angular distribution (polarization state). Simulation results demonstrate the effectiveness of our approach.

Bandyopadhyay, Saptarshi↗

Development of a mid-sized Schwarzschild-Couder Telescope for the Cherenkov Telescope Array

The Cherenkov Telescope Array (CTA) is a ground-based observatory for very high-energy (10 GeV to 100 TeV) gamma rays, planned for operation starting in 2018. It will be an array of dozens of optical telescopes, known as Atmospheric Cherenkov Telescopes (ACTs), of 8 m to 24 m diameter, deployed over an area of more than 1 square km, to detect flashes of Cherenkov light from showers initiated in the Earth's atmosphere by gamma rays. CTA will have improved angular resolution, a wider energy range, larger fields of view and an order of magnitude improvement in sensitivity over current ACT arrays such as H.E.S.S., MAGIC and VERITAS. Several institutions have proposed a research and development program to eventually contribute 36 medium-sized telescopes (9 m to 12 m diameter) to CTA to enhance and optimize its science performance. The program aims to construct a prototype of an innovative, Schwarzschild-Couder telescope (SCT) design that will allow much smaller and less expensive cameras and much larger fields of view than conventional Davies-Cotton designs, and will also include design and testing of camera electronics for the necessary advances in performance, reliability and cost. We report on the progress of the mid-sized SCT development program.

47 OTHER INSTRUMENTATION↗

Superdense coding for quantum networking environments

Quantum networks provide a versatile infrastructure for communication, computing, and sensing with quantum information. Novel sources and detectors for transmitting and receiving quantum states are critical elements in the development and eventual deployment of robust quantum networks. Alongside performance, the compatibility of quantum network devices with modern networking infrastructure is an important requirement for deployment. We present results on the integration of quantum communication using superdense coding transmitted over optical fiber links into network environments. Our approach takes advantage of a novel complete Bell-state measurement setup that relies on hyper-entanglement in the temporal and polarization degrees of freedom for a two-photon state emitted from a quantum light source. Using linear optics and common single-photon detectors, we record a single-qubit channel capacity of 1.665±0.018. We then demonstrate a full experimental implementation of hybrid, quantum-classical communication protocol for image transfer applications. Our devices integrate with existing fiber optical network and software-defined transmitters and receivers as part of a modular design to provide an extensible quantum communication system that can adapt to future quantum technology goals.

Humble, Travis↗

Sunphotometric Measurement of Columnar H2O and Aerosol Optical Depth During the 3rd Water Vapor IOP in Fall 2000 at the SGP ARM Site

We conducted ground-based measurements with the Ames Airborne Tracking 6-channel Sunphotometer (AATS-6) during the 3rd Water Vapor IOP (WVIOP3), September 18 - October 8, 2000 at the SGP ARM site. For this deployment our primary result was columnar water vapor (CWV) obtained from continuous solar transmittance measurements in the 0.94-micron band. In addition, we simultaneously measured aerosol optical depth (AOD) at 380, 450, 525, 864 and 1020 nm. During the IOP, preliminary results of CWV and AOD were displayed in real-time. The result files were made available to other investigators by noon of the next day. During WVIOP3 those data were shown on the daily intercomparison plots on the IOP web-site. Our preliminary results for CWV fell within the spread of values obtained from other techniques. After conclusion of WVIOP3, AATS-6 was shipped directly to Mauna Loa, Hawaii for post-mission calibration. The updated calibration, a cloud screening technique for AOD, along with other mostly cosmetic changes were applied to the WVIOP3 data set and released as version 0.1. The resulting changes in CWV are small, the changes in AOD and Angstrom parameter are more noticeable. Data version 0.1 was successfully submitted to the ARM External Data Center. In the poster we will show data examples for both CWV and AOD. We will also compare our CWV results with those obtained from a GPS (Global Positioning System) slant path method.

Schmid, B↗

Recent Developments in Hydrogeologic Applications for Strain Tensor Analyses

Changes in fluid pressure deform porous media and this effect occurs in a variety of hydrogeologic processes, from the change in storage during pumping or injection to fluctuations in water levels caused by barometric pressure. We have developed instruments for measuring small strains in porous media, and we have used the resulting strain data to evaluate well testing, hydraulic fracturing, manual loading at the ground surface, and ambient hydrologic processes, like rainfall and evaporation. A particularly important application is the use of strain tensor data measured at shallow depths to analyze well tests or hydraulic fractures conducted at much greater depths. An early demonstration of this technique was conducted at the North Avant Field north of Tulsa, Oklahoma, where Pennsylvanian sandstone creates a confined aquifer and oil reservoir at a depth of 530m. We have showed that the strains caused by injecting into the aquifer could be measured at a depth of 30m and used to evaluate the properties of the aquifer. We recently expanded the array of strainmeters at the North Avant Field by deploying three more instruments at shallow depth (30m) along with a deep instrument at 520m depth in the winter, 2021. The deep instrument is deployed in shale caprock slightly above the aquifer. To our knowledge, the deep strainmeter at the North Avant Field is the deepest strainmeter ever deployed and this required refining methods originally developed for shallow deployments. The instrument was lowered to depth on oil field tubing and cemented in place using techniques and materials developed for use in oil wells. Optical fiber used to communicate with the instrument was cemented in the annulus on the outside of tubing. This is significant because the techniques we used could readily be extended to greater depth, suggesting that strainmeters can be deployed over a wide range of depths for monitoring critical subsurface processes. For example, it suggests that strainmeters could be deployed through the caprock to monitor for leaks from underlying CO2 storage reservoirs. The strainmeter array at the North Avant Field has been used to characterize deformation during a series of injection tests in the spring and summer, 2021. All the new strainmeters respond to pumping, and the strainmeters we installed earlier also responded. To our knowledge, this is the first application of well testing in a deep aquifer that was monitored by an array of strainmeters—our earlier work used strainmeters at a single location. We are currently analyzing the strain data using an analytical solution, a proxy-based Bayesian inversion algorithm, and other methods. Strainmeter data has also been used to characterize periodic pumping tests by us and Riley Blais. A periodically varying pumping rate causes both hydraulic head and strain signals that vary with the same period as the pumping. The peaks and troughs of the head in monitoring wells lag behind the peaks and troughs of the head in the pumping well, and this lag time increases with distance from the pumping well. The lag time of the pressure and the distance to the monitoring well can be used in a simple analysis to estimate the hydraulic diffusivity of the aquifer. The lag time determined from strain data can be used to estimate aquifer properties using the same analysis that works for the pressure only for strain data measured at particular locations. That is because the strain field in a confining unit advances upward, laterally and then downward even though the pressure in the underlying aquifer only advances laterally, according to our recent simulations. We have field data showing that a small periodic signal superimposed on an injection rate at the North Avant Field will create a periodic strain signal at shallow strainmeters. The field data and the recent simulations suggest that including a periodic component to injection or pumping and then monitoring the resulting strain signal could be a way to monitor the subsurface.

Murdoch, Larry↗

Recent Developments in Hydrogeologic Applications for Strain Tensor Analyses

Changes in fluid pressure deform porous media and this effect occurs in a variety of hydrogeologic processes, from the change in storage during pumping or injection to fluctuations in water levels caused by barometric pressure. We have developed instruments for measuring small strains in porous media, and we have used the resulting strain data to evaluate well testing, hydraulic fracturing, manual loading at the ground surface, and ambient hydrologic processes, like rainfall and evaporation. A particularly important application is the use of strain tensor data measured at shallow depths to analyze well tests or hydraulic fractures conducted at much greater depths. An early demonstration of this technique was conducted at the North Avant Field north of Tulsa, Oklahoma, where Pennsylvanian sandstone creates a confined aquifer and oil reservoir at a depth of 530m. We have showed that the strains caused by injecting into the aquifer could be measured at a depth of 30m and used to evaluate the properties of the aquifer. We recently expanded the array of strainmeters at the North Avant Field by deploying three more instruments at shallow depth (30m) along with a deep instrument at 520m depth in the winter, 2021. The deep instrument is deployed in shale caprock slightly above the aquifer. To our knowledge, the deep strainmeter at the North Avant Field is the deepest strainmeter ever deployed and this required refining methods originally developed for shallow deployments. The instrument was lowered to depth on oil field tubing and cemented in place using techniques and materials developed for use in oil wells. Optical fiber used to communicate with the instrument was cemented in the annulus on the outside of tubing. This is significant because the techniques we used could readily be extended to greater depth, suggesting that strainmeters can be deployed over a wide range of depths for monitoring critical subsurface processes. For example, it suggests that strainmeters could be deployed through the caprock to monitor for leaks from underlying CO2 storage reservoirs. The strainmeter array at the North Avant Field has been used to characterize deformation during a series of injection tests in the spring and summer, 2021. All the new strainmeters respond to pumping, and the strainmeters we installed earlier also responded. To our knowledge, this is the first application of well testing in a deep aquifer that was monitored by an array of strainmeters—our earlier work used strainmeters at a single location. We are currently analyzing the strain data using an analytical solution, a proxy-based Bayesian inversion algorithm, and other methods. Strainmeter data has also been used to characterize periodic pumping tests by us and Riley Blais. A periodically varying pumping rate causes both hydraulic head and strain signals that vary with the same period as the pumping. The peaks and troughs of the head in monitoring wells lag behind the peaks and troughs of the head in the pumping well, and this lag time increases with distance from the pumping well. The lag time of the pressure and the distance to the monitoring well can be used in a simple analysis to estimate the hydraulic diffusivity of the aquifer. The lag time determined from strain data can be used to estimate aquifer properties using the same analysis that works for the pressure only for strain data measured at particular locations. That is because the strain field in a confining unit advances upward, laterally and then downward even though the pressure in the underlying aquifer only advances laterally, according to our recent simulations. We have field data showing that a small periodic signal superimposed on an injection rate at the North Avant Field will create a periodic strain signal at shallow strainmeters. The field data and the recent simulations suggest that including a periodic component to injection or pumping and then monitoring the resulting strain signal could be a way to monitor the subsurface.

Murdoch, Larry↗

CUDO: closed-form universal dwell-time optimization for computer-controlled optical surfacing

Precision optical figuring demands fast and accurate dwell time optimization to reach nanometer- and sub-nanometer-level accuracy in next-generation optical systems. We introduce CUDO (closed-form universal dwell-time optimization), the first, to the best of our knowledge, unified closed-form analytical framework that supports both function-form and matrix-form dwell time models in computer-controlled optical surfacing (CCOS). In contrast to traditional methods, which rely on iterative optimization and hyperparameter tuning, our framework derives direct analytical solutions with no adjustable parameters. This approach unifies the solution principles of existing methods within a single mathematical model, delivering three key advantages: (1) accuracy on par with, or superior to, iterative solvers, (2) substantial reduction in computation time, and (3) numerical robustness. Comparative studies with prior art confirm that closed-form solutions achieve equivalent residual error while removing runtime bottlenecks. By simplifying the implementation and enabling real-time, scalable deployment, CUDO establishes a practical foundation for future deterministic fabrication of large-aperture and high-performance optics.

36 MATERIALS SCIENCE↗

AERONET-OC: Strengths and Weaknesses of a Network for the Validation of Satellite Coastal Radiometric Products

The Ocean Color component of the Aerosol Robotic Network (AERONET-OC) has been implemented to support long-term satellite ocean color investigations through cross-site consistent and accurate measurements collected by autonomous radiometer systems deployed on offshore fixed platforms. The ultimate purpose of AERONET-OC is the production of standardized measurements performed at different sites with identical measuring systems and protocols, calibrated using a single reference source and method, and processed with the same code. The AERONET-OC primary data product is the normalized water leaving radiance determined at center-wavelengths of interest for satellite ocean color applications, with an uncertainty lower than 5% in the blue-green spectral regions and higher than 8% in the red. Measurements collected at 6 sites counting the northern Adriatic Sea, the Baltic Proper, the Gulf of Finland, the Persian Gulf, and, the northern and southern margins of the Middle Atlantic Bay, have shown the capability of producing quality assured data over a wide range of bio-optical conditions including Case-2 yellow substance- and sedimentdominated waters. This work briefly introduces network elements like: deployment sites, measurement method, instrument calibration, processing scheme, quality-assurance, uncertainties, data archive and products accessibility. Emphases is given to those elements which underline the network strengths (i.e., mostly standardization of any network element) and its weaknesses (i.e., the use of consolidated, but old-fashioned technology). The work also addresses the application of AERONET-OC data to the validation of primary satellite radiometric products over a variety of complex coastal waters and finally provides elements for the identification of new deployment sites most suitable to support satellite ocean color missions.

Zibordi, Giuseppe↗

A Passive Tamper Indicating Enclosure For Use Within A Nuclear Weapons Monitoring Regime

AWE and PNNL are engaged in a technical collaboration investigating techniques to enhance continuity of knowledge over Treaty Accountable Items, with emphasis on a verified nuclear weapons dismantlement process. Tamper Indicating Enclosures (TIE) will likely be deployed as part of a chain of custody regime to indicate an unauthorised attempt to access a Treaty Accountable Item, or secure authenticated monitoring equipment. In 2011, the collaboration presented a paper at the INMM annual conference held in Palm Desert, CA titled “Passive Tamper Indicating Enclosures Incorporating Embedded Optical Fibre”, which discussed the concept of integrating optical fibres into TIEs for use as a passive tamper indicating mechanism. This paper provides an update on the Fibre Optic based TIE and introduces a second passive TIE concept based on the use of Poly(Methyl MethAcrylate) (PMMA). Concepts relating to deployment, tamper indication, and unique identification will be discussed.

Arms Control, tamper indicating enclosure, chain o↗

Field test of continuous-variable quantum key distribution with a true local oscillator

A continuous-variable quantum key distribution (CV QKD) using a true local (located at the receiver) oscillator (LO) has been proposed to remove any possibility of side-channel attacks associated with transmission of the LO as well as reduce the cross-pulse contamination. Here we report an implementation of true LO-CV QKD using “off-the-shelf” components and conduct QKD experiments using the fiber optical network at Oak Ridge National Laboratory. A phase reference and quantum signal are time multiplexed and then wavelength division multiplexed with the classical communications that “coexist” with each other on a single optical network fiber. Importantly, this is the first demonstration of CV QKD with a receiver-based true LO over a deployed fiber network, a crucial step for its application in real-world situations.

97 MATHEMATICS AND COMPUTING↗

Rollable Thin-Shell Nanolaminate Mirrors

A class of lightweight, deployable, thin-shell, curved mirrors with built-in precise-shape-control actuators is being developed for high-resolution scientific imaging. This technology incorporates a combination of advanced design concepts in actuation and membrane optics that, heretofore, have been considered as separate innovations. These mirrors are conceived to be stowed compactly in a launch shroud and transported aboard spacecraft, then deployed in outer space to required precise shapes at much larger dimensions (diameters of the order of meters or tens of meters). A typical shell rollable mirror structure would include: (1) a flexible single- or multiple-layer face sheet that would include an integrated reflective surface layer that would constitute the mirror; (2) structural supports in the form of stiffeners made of a shape-memory alloy (SMA); and (3) piezoelectric actuators. The actuators, together with an electronic control subsystem, would implement a concept of hierarchical distributed control, in which (1) the SMA actuators would be used for global shape control and would generate the large deformations needed for the deployment process and (2) the piezoelectric actuators would generate smaller deformations and would be used primarily to effect fine local control of the shape of the mirror.

Hickey, Gregory↗

COLLABORATIVE RESEARCH: Study of Aerosol Sources and Processing at the GVAX Pantnagar Supersite

This project funded the participation of scientists from seven research groups, running more than thirty instruments, in the Winter Intensive Operating Period (January-February 2012) of the Clean Air for London (ClearfLo) campaign at a rural site in Detling, UK, 45 km southeast of central London. The primary science questions for the ClearfLo Winter IOP were, 1) what is the urban increment of particulate matter (PM) and other pollutants in the greater London area, and, 2) what is the contribution of solid fuel use for home heating to wintertime PM? An additional motivation for the Detling measurements was the question of whether coatings on black carbon particles enhance absorption. The following four key accomplishments have been identified so far: 1) Chemical, physical and optical characterization of PM from local and regional sources (Figures 2, 4, 5 and 6). 2) Measurement of urban increment in particulate matter and gases in London (Figure 3). 3) Measurement of optical properties and chemical composition of coatings on black carbon containing particles indicates absorption enhancement. 4) First deployment of chemical ionization instrument (MOVI-CI-TOFMS) to measure both particle-phase and gas-phase organic acids. (See final report from Joel Thornton, University of Washington, for details.) Analysis of the large dataset acquired in Detling is ongoing and will yield further key accomplishments. These measurements of urban and rural aerosol properties will contribute to improved modeling of regional aerosol emissions, and of atmospheric aging and removal. The measurement of absorption enhancement by coatings on black carbon will contribute to improved modeling of the direct radiative properties of PM.

54 ENVIRONMENTAL SCIENCES↗