Search NASA⌕ Search

SEARCH · Search NASA

Results for “detector resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Negative affinity X-ray photocathodes

A new X-ray image intensifier is described. The device should eventually have a quantum efficiency which is an order of magnitude greater than that of presently available high spatial resolution X-ray detectors, such as microchannel plates. The new intesifier is based upon a GaAs crystal photocathode which is activated to achieve negative electron affinity. Details concerning the detector concept are discussed together with the theoretical relations involved, X-ray data, and optical data.

Vanspeybroeck, L.↗

Modulation of auroral electron fluxes in the frequency range 50 kHz to 10 MHz

A sounding rocket-borne electron detector of high time resolution is used to search for modulation of auroral electron fluxes in the frequency range 50 kHz to 10 MHz and energy range 5-7 keV. Data were telemetered to ground via a 93-kHz subcarrier. A cross-correlation analysis of the data collected indicates low-level modulation near the detection threshold of the instrument. Two U-1 events are observed which are interpreted as indications of modulation. The two modulation events occur during a period of increasing flux for a region marking the boundary between two current sheets detected by the payload magnetometer. The strongest argument against interference contamination is the lack of any observable modulation at times other than those mentioned in the study.

Spiger, R. J.↗

Characterization of gigahertz (GHz) bandwidth photomultipliers

The average impulse response, root-mean-square times jitter as a function of signal level, single photoelectron distribution, and multiphotoelectron dark-count distribution have been measured for two static crossed-field and five electrostatic photomultipliers. The optical signal source for the first three of these tests was a 30 picosecond mode-locked laser pulse at 0.53 micron. The static crossed-field detectors had 2-photoelectron resolution, less than 200 ps rise times, and rms time jitters of 30 ps at the single photoelectron level. The electrostatic photomultipliers had rise times from 1 to 2.5 nanoseconds, and rms time jitters from 160 to 650 ps at the same signal level. The two static crossed-field photomultipliers had ion-feedback-generated dark pulses to the 50-photoelectron level, whereas one electrostatic photomultiplier had dark pulses to the 30-photoelectron level.

Abshire, J. B.↗

An instrument to measure the spectrum of cosmic ray iron and other nuclei to above 100 GeV-nucleon

A balloon-borne detector system for extending the study of cosmic ray composition to the energy region beyond 100 GeV/nucleon is described. The instrument incorporates an ionization calorimeter and a gas Cherenkov counter filled with freon for the determination of energies, and a charge module, consisting of scintillation and a lucite Cherenkov counter, for determining the charge of the incoming particle. The scintillators were utilized to determine the position of the incoming particle in addition to its charge. The characteristics of these detectors with respect to resolution, and the methods employed in laboratory calibration, cross-checks with flight data and actual performance in the flights are described in detail. Monte Carlo simulation of the ionization calorimeter and comparison of the response of the calorimeter and gas Cherenkov counter for complex nuclei was used to convert the observed calorimeter signal to absolute energy in a consistent manner.

Arens, J. F.↗

Simulated electronic heterodyne recording and processing of pulsed-laser holograms

The electronic recording of pulsed-laser holograms is proposed. The polarization sensitivity of each resolution element of the detector is controlled independently to add an arbitrary phase to the image waves. This method which can be used to simulate heterodyne recording and to process three-dimensional optical images, is based on a similar method for heterodyne recording and processing of continuous-wave holograms.

Decker, A. J.↗

Resolution enhanced sound detecting apparatus

An apparatus is described for enhancing the resolution of a sound detector of the type which includes an acoustic mirror for focusing sound from an object onto a microphone to enable the determination of the location from which the sound arises. The enhancement apparatus includes an enclosure which surrounds the space between the mirror and microphone, and contains a gas heavier than air, such as Freon, through which sound moves slower and therefore with a shorter wavelength than in air, so that a mirror of given size has greater resolving power. An acoustically transparent front wall of the enclosure which lies forward of the mirror, can include a pair of thin sheets with pressured air between them, to form an end of the region of heavy gas into a concave shape.

Kendall, J. M.↗

Space Telescope Digicon

The Digicon, chosen by NASA as the detector for the High Resolution Spectrograph (HRS) and the Faint Object Spectrograph (FOS) is a 512 parallel output channel vacuum photodetector. There are two HRS Digicons with spectral sensitivity ranges from 1050 A to 1800 A and 1150 A to 3000 A respectively, and two FOS Digicons, which have spectral ranges extending to 7000 A. The significant requirements for these devices are 0.01 counts per second background count rate per diode, state-of-the-art Digicon pulse height resolution (typical 15%) and a high degree of imaging precision and stability. The results of a manufacturing and test program to develop the Digicons coupled with extensive prior work has shown that these requirements can be met. The Digicon because of its inherent ruggedness is particularly well suited to space applications.

Alting-Mees, H. R.↗

Sounding-rocket experiment to study the diffuse soft X-ray background using a Si(Li) detector

Soft X-ray background in the energy range 0.4 to 10 keV was studied. A payload was developed which uses a wide angle, windowless, cooled, Si(Li) semiconductor detector system. With a resolution of less than 150 eV between 0.3 and 2.0 keV, the system is sensitive to an emission equivalent width of about 10 eV. Carbon and oxygen line emission were detected from the vicinity of the North Galactic Pole and the North Polar Spur.

Delvaille, J. P.↗

State-of-the-art Space Telescope Digicon performance data

The Digicon has been chosen as the detector for the High Resolution Spectrograph and the Faint Object Spectrograph of the Space Telescope. Both tubes are 512 channel, parallel-output devices and feature CsTe photocathodes on MgF2 faceplates. Using a computer-assisted test facility, the tubes have been characterized with respect to diode array performance, photocathode response (1100-9000 A), and imaging capability. Data are presented on diode dark current and capacitance distributions, pulse height resolution, photocathode quantum efficiency, uniformity and blemishes, dark count rate, distortion, resolution, and crosstalk.

Ginaven, R. O.↗

High resolution X-ray scattering measurements for Advanced X-ray Astrophysics Facility /AXAF/

The Advanced X-ray Astrophysics Facility (AXAF) is to be an orbiting X-ray observatory with high resolution imaging capabilities. Specific goals of 0.5 arcsecond resolution, and an encircled energy of 60% within a 1.0 arcsecond diameter circle at 2.5 keV have been established for AXAF. Imaging X-ray optics are primarily limited by scattering of the X-rays from the mirror surfaces. To ensure that the AXAF goals can be met, comprehensive X-ray scattering measurements are being conducted on a large number of flat samples. Sub-arcsecond resolution is achieved in these measurements through use of the MSFC 1000 ft X-ray calibration facility and a high spatial resolution X-ray detector. Flats of various materials, various coatings, and a range of rms surface roughness are being evaluated. Direct evaluation of surface microroughness is also provided by a variety of optical and non-optical means. This paper describes the scattering measurement program, the instrumentation used to obtain the measurements and preliminary results of measurements on several of the sample flats.

Zombeck, M. V.↗

An extreme ultraviolet spectrometer experiment for the Shuttle Get Away Special Program

An extreme ultraviolet (EUV) spectrometer experiment operated successfully during the STS-7 mission in an experiment to measure the global and diurnal variation of the EUV airglow. The spectrometer is an F 3.5 Wadsworth mount with mechanical collimator, a 75 x 75 mm grating, and a bare microchannel plate detector providing a spectral resolution of 7 X FWHM. Read-out of the signal is through discrete channels or resistive anode techniques. The experiment includes a microcomputer, 20 Mbit tape recorder, and a 28V, 40 Ahr silver-zinc battery. It is the first GAS payload to use an opening door. The spectrometer's 0.1 x 4.2 deg field of view is pointed vertically out of the shuttle bay. During the STS-7 flight data were acquired continuously for a period of 5 hours and 37 minutes, providing spectra of the 570 A to 850 A wavelength region of the airglow. Five diurnal cycles of the 584 A emission of neutral helium and the 834 A emission of ionized atomic oxygen were recorded. The experiment also recorded ion events and pressure pulses associated with thruster firings. The experiment is to fly again on Mission 41-F.

Conway, R. R.↗

Cosmic X-ray physics

A progress report of research activities carried out in the area of cosmic X-ray physics is presented. The Diffuse X-ray Spectrometer DXS which has been flown twice as a rocket payload is described. The observation times proved to be too small for meaningful X-ray data to be obtained. Data collection and reduction activities from the Ultra-Soft X-ray background (UXT) instrument are described. UXT consists of three mechanically-collimated X-ray gas proportional counters with window/filter combinations which allow measurements in three energy bands, Be (80-110 eV), B (90-187 eV), and O (e84-532 eV). The Be band measurements provide an important constraint on local absorption of X-rays from the hot component of the local interstellar medium. Work has also continued on the development of a calorimetric detector for high-resolution spectroscopy in the 0.1 keV - 8keV energy range.

Mccammon, D.↗

Construction of a cosmic ray air shower telescope

The telescope under construction is mainly for the purpose of locating the arrival directions of energetic particles and quanta which generate air showers of sizes 10 to the 5th power to 10 to the 6th power. Both fast timing method and visual track method are incorporated in determining the arrival directions. The telescope is composed of four stations using scintillators and neon flash tubes as detectors. The system directional resolution is better than 1.5 deg.

Ng, L. K.↗

A long duration balloon-borne telescope for solar gamma-ray astronomy

A new solar gamma-ray telescope is described which is intended to take advantage of current long-duration ballon facilities such as the RACOON system. The primary scientific objective is to detect and measure gamma-ray lines from solar flares, along with the associated low-energy continuum. The proposed instrument is centered on a multiheaded Ge system and is designed to operate over the energy range 50 keV to 200 200 MeV. In the nuclear transition energy region, the average energy resolution of the primary detectors is over 20 times better than that achieved with the gamma-ray spectrometer on the Solar Maximum Mission satellite.

Owens, Alan↗

The double nucleus galaxies Mkn 423 and Mkn 739

Long slit spectroscopy and imaging of Mkn 423 and Mkn 739 were performed on the 2.2 m and 3.5 m telescopes of the Calar Alto Observatory using both change coupled device (CCD) and photographic detectors. Low and medium resolution spectra (1.8A, 3.5A, 6.0A) together with V images have permitted the demonstration of the merging nature of Mkn 423 and the double structure of the narrow line region (NLR) of its Seyfert component. This last feature has been found also in the NLR of the Seyfert component of Mkn 739, a double system the two components of which are counterrotating.

Rafanelli, Piero↗

The contribution of methanol to the 3.4 micron feature in comets

With the advent of improved detectors and improved moderate resolution spectrometers several interesting features have been seen in the infrared spectra of comets. In particular, an emission excess at 3.52 microns was observed in several comets, and has recently been tentatively assigned to the nu 3 band of methanol (CH3OH). Using a developed model it is possible to calculate the relative strengths of the CH3OH features. The 3.52 microns emission strengths were used in a number of comets to retrieve methanol amounts, and the model was used to predict the fraction of the 3.4 micron flux which is contributed by the species. Implications for cometary formation are discussed.

Reuter, Dennis C.↗

Use of mercuric iodide X-ray detectors with alpha backscattering spectrometers for space applications

The authors present X-ray fluorescence (XRF) spectra of different extraterrestrial samples taken with a mercuric iodide (HgI2) spectrometer inserted into an alpha backscattering instrument identical to that used in the Soviet Phobos mission. The results obtained with the HgI2 ambient temperature detector are compared with those obtained using an Si(Li) cryogenically cooled detector. Efforts to design an optimized instrument for space application are also described. The results presented indicate that the energy resolution and sensitivity of HgI2 detectors are adequate to meet the performance needs of a number of proposed space applications, particularly those in which cooled silicon X-ray detectors are impractical or even not usable, such as for the target science programs on geoscience opportunities for lunar surface, Mars surface, and other comet and planetary missions being planned by NASA and ESA.

Iwanczyk, J. S.↗

Lower-hybrid collapse, caviton turbulence, and charged particle energization in the topside auroral ionosphere and magnetosphere

A scenario, first introduced by Retterer et al. (1986), is described which can result in the collapse of the lower-hybrid modes to shorter wavelengths to achieve the resonance matching with the tail region of the cold ionospheric ion distribution. The theory also predicts the simultaneous occurrence of counterstreaming electrons that are commonly observed in conjunction with the ion conics in the suprauroral region. These theoretical predictions are confirmed by recent high-altitude sounding rocket experiments utilizing innovative high time resolution wave and particle detectors.

Chang, Tom↗