Search NASA⌕ Search

SEARCH · Search NASA

Results for “device testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

SU-E-T-112: An OpenCL-Based Cross-Platform Monte Carlo Dose Engine (oclMC) for Coupled Photon-Electron Transport

Purpose: Low computational efficiency of Monte Carlo (MC) dose calculation impedes its clinical applications. Although a number of MC dose packages have been developed over the past few years, enabling fast MC dose calculations, most of these packages were developed under NVidia’s CUDA environment. This limited their code portability to other platforms, hindering the introduction of GPU-based MC dose engines to clinical practice. To solve this problem, we developed a cross-platform fast MC dose engine named oclMC under OpenCL environment for external photon and electron radiotherapy. Methods: Coupled photon-electron simulation was implemented with standard analogue simulation scheme for photon transport and Class II condensed history scheme for electron transport. We tested the accuracy and efficiency of oclMC by comparing the doses calculated using oclMC and gDPM, a previously developed GPU-based MC code on NVidia GPU platform, for a 15MeV electron beam and a 6MV photon beam in a homogenous water phantom, a water-bone-lung-water slab phantom and a half-slab phantom. We also tested code portability of oclMC on different devices, including an NVidia GPU, two AMD GPUs and an Intel CPU. Results: Satisfactory agreements were observed in all photon and electron cases, with ∼0.48%–0.53% average dose differences at regions within 10% isodose line for electron beam cases and ∼0.15%–0.17% for photon beam cases. It took oclMC 3–4 sec to perform transport simulation for electron beam on NVidia Titan GPU and 35–51 sec for photon beam, both with ∼0.5% statistical uncertainty. The computation was 6%–17% slower than gDPM due to the differences in both physics model and development environment, which is considered not significant for clinical applications. In terms of code portability, gDPM only runs on NVidia GPUs, while oclMC successfully runs on all the tested devices. Conclusion: oclMC is an accurate and fast MC dose engine. Its high cross-platform portability makes it clinically attractive.

60 APPLIED LIFE SCIENCES↗

SPE-5 Booster System: Design and Qualification Testing

The SPE-5 device presents a unique set of requirements for the initiation and booster system. This report documents the design of the booster and qualification test results to meet the requirements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improving performance of the MgZnO ultraviolet photodetectors by changing the interdigital electrode width

Highlights: • The different electrode width of the metal-semiconductor-metal photodetectors are fabricated by the radio frequency magnetron sputtering technique. • The responsivity and the dark current of the photodetectors will vary with the electrode width. • The main reason of the interesting phenomenon is the change of the density of the carriers. - Abstract: We grow the Mg{sub 0.24}Zn{sub 0.76}O thin film onto a quartz substrate by the radio frequency magnetron sputtering technique. Planar geometry metal-semiconductor-metal structured ultraviolet detectors were fabricated by conventional ultraviolet lithography and wet etching on the Mg{sub 0.24}Zn{sub 0.76}O thin films. To improve the performance of the device, three kinds of photodetectors with different electrode width were fabricated, after a series of tests on those device, it is amusing to find an interesting phenomenon, the Mg{sub 0.24}Zn{sub 0.76}O photodetectors with different electrode width have a great influence on the performance of the whole device. The Mg{sub 0.24}Zn{sub 0.76}O photodetectors that own larger electrode width had a higher responsivity and lower dark current than the photodetectors own littler electrode width. These interesting results are very meaningful for the photodetector industry.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A device for the application of uniaxial strain to single crystal samples for use in synchrotron radiation experiments

We present the design, construction, and testing of a straining device compatible with many different synchrotron radiation techniques, in a wide range of experimental environments (including low temperature, high field and ultra-high vacuum). The device has been tested by X-ray diffraction on single crystal samples of quasi-one-dimensional Cs{sub 2}Mo{sub 6}Se{sub 6} and K{sub 2}Mo{sub 6}Se{sub 6}, in which microscopic strains up to a Δc/c = 0.12% ± 0.01% change in the c lattice parameters have been achieved. We have also used the device in an inelastic X-ray scattering experiment, to probe the strain-dependent speed of sound ν along the c axis. A reduction Δν/ν of up to −3.8% was obtained at a strain of Δc/c = 0.25% in K{sub 2}Mo{sub 6}Se{sub 6}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New Zealand Multi-Mode Technology Demonstration at the US Navy's Wave Energy Test Site

The objective of the project is to redeploy the Wave Energy Technology – New Zealand (WET-NZ and now known as Azura) device that was tested at the NNMREC test site in 2013 at the United States Navy’s Wave Energy Test Site (WETS). The goal is to conduct open-ocean, grid connected testing for a period of up to 12 months to 1) optimize energy capture and 2) validate LCOE model.

16 TIDAL AND WAVE POWER↗

Advanced Energy Harvesting Control Schemes for Marine Renewable Energy Devices

The Advanced Energy Harvesting Control Schemes for Marine Renewable Energy Devices (Project) investigated, analyzed and modeled advanced turbine control schemes with the objective of increasing the energy harvested by hydrokinetic turbines in turbulent flow. Ocean Renewable Power Company (ORPC) implemented and validated a feedforward controller to increase power capture; and applied and tested the controls on ORPC’s RivGen® Power Systems in Igiugig, Alaska. Assessments of performance improvements were made for the RivGen® in the Igiugig environment and for ORPC’s TidGen® Power System in a reference tidal environment. Annualized Energy Production (AEP) and Levelized Cost of Energy (LCOE) improvements associated with implementation of the recommended control methodology were made for the TidGen® Power System in the DOE reference tidal environment. System Performance Advancement (SPA) goals were selected for the project. SPA targets were to improve Power to Weight Ratio (PWR) and system Availability, with the intention of reducing Levelized Cost of Electricity (LCOE). This project focused primarily reducing in PWR. Reductions in PWR of 25.5% were achieved. Reductions of 20.3% in LCOE were achieved. This project evaluated four types of controllers which were tested in simulation, emulation, a laboratory flume, and the field. The adaptive Kω2 controller performs similarly to the non-adaptive version of the same controller and may be useful in tidal channels where the mean velocity is continually evolving. Trends in simulation were largely verified through experiments, which also provided the opportunity to test assumptions about turbine responsiveness and control resilience to varying scales of turbulence. Laboratory experiments provided an essential stepping stone between simulation and implementation on a field-scale turbine. Experiments also demonstrated that using “energy loss” as a metric to differentiate between well-designed controllers operating at an optimal tip-speed ratio set-point is difficult, which anticipated the outcome from field experiments. The clear message is that the feedforward Kω2 controller out-performs the feedback controllers in almost all aspects and modes of evaluation. The controllers proved a substantial improvement over the baseline performance of the TidGen® turbine, in terms of energy capture. The effects of noise-contaminated angular velocity signals were investigated and validated by simulation as an explanation for the performance limitations observed for TidGen® turbine operations in Eastport, Maine. Measurements of loads performed as part of the laboratory testing indicate that there are limited differences in average axial thrust force between control architectures. This suggests that none of the control strategies are likely to substantially affect loads on the turbine support structure. Velocity measurements during the ORPC RivGen® turbine deployment at Igiugig, Alaska, in 2014 were used to assess the variability of the river flow. Results suggest that the river flow is approximately steady, in the mean sense, at any particular location in the river, with random turbulent fluctuations that are around 10% of the mean flow. The mean flow in the center channel of the river is 2.5 m/s, with reductions near the riverbanks and in the shallows. Spectral analysis and lagged correlation results indicate that temporal fluctuations at a given point are dominated by large scale fluctuations, such that measurements at the turbine location are just as useful for inflow control implementation as upstream measurements. At this site, and likely at many other river sites, flow is generally steady at a given location, but flow varies dramatically between locations, particularly laterally across the river. The primary result is that a lateral change in position of a few meters results in changes to flow speed that far exceed the turbulence fluctuations at any given location. The turbulence is dominated by long time scales. Following final system tests, the RivGen® device was submerged and each evaluated controller was tested across a range of gain/set point values and filter configurations for a minimum of 5 minutes, with longer runs attempted for well-performing cases. In addition to testing controllers during the 2015 deployment season, LGL Alaska Research Associates Inc. (LGL) performed a fish monitoring study in compliance with Alaska Department of Fish and Game fisheries habitat permit for the project. During the season, LGL reviewed 10% of 179 one-hour blocks of footage (6 minutes on the hour) and documented a total of over 1200 fish in the vicinity of the RivGen® device, including over 800 salmon smolt and over 350 adult salmon. No evidence of adverse effects including passage delay by upstream migrating salmon was noted. This is an important result for future deployments and has a direct impact on commercial system designs.

16 TIDAL AND WAVE POWER↗

Helicon plasma ion temperature measurements and observed ion cyclotron heating in proto-MPEX

The Prototype-Material Plasma Exposure eXperiment (Proto-MPEX) linear plasma device is a test bed for exploring and developing plasma source concepts to be employed in the future steady-state linear device Material Plasma Exposure eXperiment (MPEX) that will study plasma-material interactions for the nuclear fusion program. The concept foresees using a helicon plasma source supplemented with electron and ion heating systems to reach necessary plasma conditions. Here in this paper, we discuss ion temperature measurements obtained from Doppler broadening of spectral lines from argon ion test particles. Plasmas produced with helicon heating alone have average ion temperatures downstream of the Helicon antenna in the range of 3 ± 1 eV; ion temperature increases to 10 ± 3 eV are observed with the addition of ion cyclotron heating (ICH). The temperatures are higher at the edge than the center of the plasma either with or without ICH. This type of profile is observed with electrons as well. Finally, a one-dimensional RF antenna model is used to show where heating of the plasma is expected.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Commissioning, Performance, and Effect of the Quench Current-Boosting Device on a Dedicated Superconducting Magnet

Superconducting magnet training is one of the accelerator related issues attracting attention due to significant operational costs and time budget associated to it. It is especially worrisome that magnets based on the “next-generation” Nb 3 Sn technology are affected by long training. While various efforts are underway to better understand and resolve the problem a parallel path could also be investigated, a path bypassing the issue. Following the concept of fast induced over-current during magnet powering, FNAL has developed an upgradable capacitor-based device to discharge through a superconducting magnet at quench detection or operator chosen time. The 0.4 F/1 kV device has been tested on a 1-m-long dipole-coil in a “mirror” magnet configuration and conclusive results on magnet training elimination have been observed. Here in this paper we discuss the main characteristics of the device, compare simulated response and actual performance, elaborate on test drivers and outcomes. Next steps and perspectives for future use are debated.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fleet Evaluation and Factory Installation of Aerodynamic Heavy Duty Truck Trailers

The purpose of DE-EE0001552 was to develop and deploy a combination of trailer aerodynamic devices and low rolling resistance tires that reduce fuel consumption of a class 8 heavy duty tractor-trailer combination vehicle by 15%. There were 3 phases of the project: Phase 1 – Perform SAE Typed 2 track tests with multiple device combinations. Phase 2 – Conduct a fleet evaluation with selected device combination. Phase 3 – Develop the devices required to manufacture the aerodynamic trailer. All 3 phases have been completed. There is an abundance of available trailer devices on the market, and fleets and owner operators have awareness of them and are purchasing them. The products developed in conjunction with this project are at least in their second round of refinement. The fleet test undertaken showed an improvement of 5.5 – 7.8% fuel economy with the devices (This does not include tire contribution).

Beck, Jason↗

Moment tensor reconstruction

A seismic monitoring system includes a plurality of seismic monitors and a processing device operatively coupled to the plurality of seismic monitors. The processing device receives recordings of waveforms of motion detected at the plurality of seismic detectors in a geographic area. The processing device applies the respective recordings to corresponding positions of the seismic detectors in a three-dimensional geological model that describes its elastic attributes and tests a plurality of moment tensors at a plurality of locations. Based on the testing, the processing device determines a globally convergent source location and moment tensor in the three-dimensional model based on the testing.

Petrov, Petr↗

Feasibility of Passive MOSFET Paralleling for Photovoltaic Current-Voltage Curves

Current-voltage curves are an important method of characterizing Photovoltaic (PV) Modules. NREL has developed several low-cost MOSFET-based devices that can characterize PV cells and modules. The size of PV modules that can be measured is limited by the power limitations of a single MOSFET. By using multiple MOSFET devices, each can operate at a lower current, paralleled on resistance is also decreased allowing for higher power loads. Operating multiple devices in parallel can cause an imbalance in current, thus causing some devices to conduct more, pushing them into a thermal runaway condition. To investigate this, an active feedback circuit was tested with paralleled devices using a PV module load. The efficacy, limitations, and design considerations of using parallel MOSFET loads for PV characterization are explored. This work is not new, but the implementation of a paralleled architecture in a low cost characterization tool is novel.

14 SOLAR ENERGY↗

Quality Assurance methodology for the ATLAS Inner Tracker strip sensor production

The production of the strip sensors for the ATLAS Inner Tracker (ITk) will start in 2020. Nearly 22,000 large area sensors will be produced over a period of about five years by Hamamatsu Photonics K.K. (HPK). The institutes involved in the sensor development and production are committed to deliver and maintain the highest quality sensors for the experiment. A Quality Assurance (QA) strategy has been prepared to be carried out during the whole production period. Once the process has been characterized as providing the required pre-irradiation specifications and the proper radiation hardness, the onus is on the manufacturer to rigidly stick to that qualified process. Still, sample testing with specific device-element structures and irradiation of devices should be implemented by the ITk sensor collaboration. A detailed irradiation and testing plan has been prepared by the ATLAS-ITk Collaboration, together with a newly designed test chip with specific structures to monitor different key technological and device parameters during the whole production. The tests and irradiations will be carried out on a sample basis. In order to have a practical methodology, samples from alternating batches will be sent for irradiations with protons, neutrons and gammas, and then tested in order to check that the characteristics remain within specifications. Here we present the detailed plan and the design and test methods for the structures in the test chip.

47 OTHER INSTRUMENTATION↗

2011 Marine Hydrokinetic Device Modeling Workshop: Final Report; March 1, 2011

This report summarizes the NREL Marine and Hydrokinetic Device Modeling Workshop. The objectives for the modeling workshop were to: 1) Review the designs of existing MHK device prototypes and discuss design and optimization procedures; 2) Assess the utility and limitations of modeling techniques and methods presently used for modeling MHK devices; 3) Assess the utility and limitations of modelingmethods used in other areas, such as naval architecture and ocean engineering (e.g., oil & gas industry); and 4) Identify the necessary steps to link modeling with other important components that analyze MHK devices (e.g., tank testing, PTO design, mechanical design).

13 HYDRO ENERGY↗

Development of a DC Distribution Testbed for High-Power EV Charging

This paper explores the design and implementation of a power hardware-in-the-loop (P-HIL) setup for DC distribution infrastructure integrated with high-power charging (HPC) of electric vehicles (EVs), DC loads, and sources. The utilization of DC distribution holds significant potential for enhancing the operation of a HPC station architecture. However, there are challenges establishing a DC charging hub including interoperability, commoditization, distributed energy resource integration, stability, DC protection, and lack of common system level controllers. To address these challenges, a testing setup is required that accommodates commercial off-the-shelf (COTS) products to evaluate different use cases at rated power and voltage levels. The developed P-HIL setup features a dedicated DC charging hub, DC-coupled chargers, DC loads/sources, DC protection, and a communication architecture. The integrated P-HIL system provides a versatile testing environment to address technology and interoperability gaps and implements a smart energy management system (SEMS). This platform enables comprehensive and robust testing of COTS devices, charger prototypes, SEMS controllers and protection schemes, which together will accelerate transition to EVs at scale. The setup is tested for various use-cases at full-scale, integrating 950 V DC bus voltage, 660 kW grid-tied inverter, 150 kW COTS charger, and 100 kW energy storage system within an open-source SEMS platform.

ADVANCED PROPULSION SYSTEMS,POWER TRANSMISSION AND↗

Testing the Performance and Dynamic Control of Energy-Efficient Cellular Shades in the PNNL Lab Homes

This report describes the experimental design and results of testing the energy performance of Hunter Douglas double-cell cellular shades under various control schemes in the Pacific Northwest National Laboratory’s (PNNL) Lab Homes. The results of both heating and cooling season experiments are presented, where testing is designed to assess the heating, ventilation, and air conditioning (HVAC) savings resulting from the thermal insulating properties as well as the automated and dynamic control strategies of shading devices. Control schemes tested include common “connected home” strategies where controls are integrated and coordinated between the window shading device, building thermostats, and external sensors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cryomodule Test Stand Reduced-Magnetic Support Design At Fermilab

In a partnership with SLAC National Accelerator Laboratory (SLAC) and Jefferson Lab, Fermilab will assemble and test 17 of the 35 total 1.3 GHz cryomodules for the Linac Coherent Light Source II (LCLS-II) Project. These devices will be tested at Fermilab's Cryomodule Test Facility (CMTF) within the Cryomodule Test Stand (CMTS-1) cave. The problem of magnetic pollution became one of major issues during design stage of the LCLS-II cryomodule as the average quality factor of the accelerating cavities is specified to be $2.7 \times 10^{10}$. One of the possible ways to mitigate the effect of stray magnetic fields and to keep it below the goal of 5 mGauss involves the application of low permeable materials. Initial permeability and magnetic measurement studies regarding the use of 316L stainless steel material indicated that cold work (machining) and heat affected zones from welding would be acceptable.

43 PARTICLE ACCELERATORS↗

Implementation of WBG devices in circuits - Electric Drive Technologies Project (Final Technical Report)

The objective of the project is to ensure that SiC devices are reliable and rugged as required in automotive applications for operational life of 300,000 hrs and create new device designs to address various weaknesses in currently available commercial devices. OSU has worked closely with SUNY Polytechnic. OSU has carried out the reliability and ruggedness evaluations of commercial devices as well as those fabricated by SUNY Polytechnic, discussed the results with SUNY Poly, and collaborated with the PI at SUNY Poly to improve the designs with respect to reliability/ruggedness. OSU work focused on reliability/ruggedness evaluation of SiC devices by individually testing them and then evaluate them in a 10 kW, 3 phase inverter system built with a specific purpose of stressing devices using realistic drive cycles such as a 10-minute hill climb. It should be noted that the primary purpose of the 10 kW inverter is to provide a platform for stressing the SiC devices under accelerated but realistic drive conditions.

33 ADVANCED PROPULSION SYSTEMS↗

Test results of a counting type SOI device for a new x-ray area detector

Development of a new detector using Silicon-On-Insulator (SOI) technology has been started in the Photon Factory, KEK. The aim of this project is to develop a pulse-counting-type X-ray detector that can be used in synchrotron radiation experiments using soft X-rays. We started to make a Test Element Group of SOI chip, which is called CPIXPTEG1 and evaluated its performance. We succeeded in readout of output signals for 16 keV X-rays from the SOI chips. We also found that the middle-SOI structure was effective against a signal distortion caused by hole traps in the buried oxide layer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗