Search NASA⌕ Search

SEARCH · Search NASA

Results for “efficient envelope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Energy efficient soundproofing window retrofits

Described herein are window retrofits including a monolithic silica aerogel slab having (i) an average haze value of <5% as calculated in accordance with ASTM standard D1003-13 and (ii) a U-factor of <0.5 BTU/sf/hr/° F., and a transparent polymer envelope sealed at an internal pressure of ≤1 atmosphere, wherein the monolithic silica aerogel slab is encapsulated in the transparent polymer envelope. The monolithic aerogel slab can have a transmittance >94% at 8 mm thickness. The window retrofit can be bonded to a glass sheet.

Wang, Evelyn N.↗

Experimental studies of a high-gradient X-band welded hard-copper split accelerating structure

We report on recent research on high-gradient radio frequency (RF) accelerating structures indicates that the use of hard copper alloys provides improvement in high gradient performance over annealed copper. Such structures are made by bonding individually manufactured parts. However, there are no well-established bonding techniques that preserve the hardness, surface finish and cleanliness required for high gradient operation. To preserve the copper hardness, RadiaBeam has developed a novel high-gradient split accelerating structure, based on electron beam welding joining technique. This technique provides efficient bonding with strong, clean welds and minimal thermal loading, while maintaining a clean inner RF environment. Our RF design and fabrication methodology limits the small heat affected zone to the outer cavity envelop, with virtually no distortions or thermal loading of critical RF surfaces. It also incorporates provisions to precisely control the gap despite conventional issues with weld joint shrinkage. To date we have manufactured and validated an RF accelerating structure joined by electron-beam welding that incorporates a novel open split design to significantly reduce the assembly complexity and cost. In this paper, we will present the electromagnetic design of this structure, discuss bonding, and present the results of high-power tests, where the accelerating gradients of 140 MV m -1 with surface peak fields of 400 MV m -1 were achieved for flat-top pulse length of 600 ns with an RF breakdown rate of 10 -4 1/(pulsecm).

43 PARTICLE ACCELERATORS↗

Equitable Electrification Analysis for Existing Buildings in Richmond, CA

Over a 12-month period beginning in July 2022, NREL coordinated with a coalition of staff from the City of Richmond and local community organizations to develop and conduct a city-wide building energy use analysis and develop and assess the impacts of various approaches to electrifying and improving energy efficiency of all existing residential and commercial buildings within the city limits. Building on data available through NREL's ResStock™ and ComStock™ analysis tools, the authors looked at potential modeled impacts of building envelope and electrification upgrades on five indicators identified by the community coalition: building energy consumption, greenhouse gas (GHG) emissions, utility bill charges and cost-effectiveness, employment impacts, and health and safety impacts. This report summarizes the findings of that research and analysis.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Stellar kinematics of elliptical galaxies in pairs

In both galaxy pairs Arp 166 and 3C 278 the authors find radially increasing velocity dispersions indicating a perturbed, non-equilibrium state of the galaxies after the tidal interaction. In all galaxies, the increase is most pronounced in the regions which correspond to the centers of the outer isophotes. The authors suggest a scenario in which the galaxies are strongly decelerated on their orbits during the encounter. The deceleration depends on the radial position in the perturbed galaxy and vanishes in the center of the perturbed galaxy (Spitzer, 1958). In addition, the crossing time of the stars near the center is very short, implying that the tidal perturbations can be averaged over several orbital periods (e.g., Binney and Tremaine, 1987). In consequence, the central parts are not affected by the tidal interaction while the outer parts are strongly decelerated. This leads to a displacement of the central parts of the galaxies with respect to their envelopes in an anti-symmetrical way for the two components of each galaxy pair. The motions of the central parts subsequently are opposed by dynamical friction with the surrounding envelopes. Due to dynamical friction, the density of the stars increases in the wakes of the moving central parts (Mulder, 1983). The overdensity of stars in the wakes of the moving central parts efficiently decelerates the motions of the central parts. The reaction of the stars in the overdensity regions leads to an increase of the velocity dispersion mainly along the orbits of the moving central parts. The presented observations, especially the asymmetrical luminosity profiles and the radially increasing velocity dispersions support consistently the above scenario of tidal interaction between galaxies. Further spectroscopic observations are necessary in order to investigate the degree of anisotropy in the kinematically perturbed regions.

Madejsky, Rainer↗

Experiment Design for Complex VTOL Aircraft with Distributed Propulsion and Tilt Wing

Selected experimental results from a wind tunnel study of a subscale VTOL concept with distributed propulsion and tilt lifting surfaces are presented. The vehicle complexity and automated test facility were ideal for use with a randomized designed experiment. Design of Experiments and Response Surface Methods were invoked to produce run efficient, statistically rigorous regression models with minimized prediction error. Static tests were conducted at the NASA Langley 12-Foot Low-Speed Tunnel to model all six aerodynamic coefficients over a large flight envelope. This work supports investigations at NASA Langley in developing advanced configurations, simulations, and advanced control systems.

Murphy, Patrick C.↗

Online Airtightness Calculator for the US, Canada and China

The contribution of air leakage to heating and cooling loads has been increasing as the thermal resistance of building envelopes continues to improve. Easy-to-access data are needed to convince building owners and contractors that enhancing the airtightness of buildings is the next logical step to achieve a high-performance building envelope. To this end, Oak Ridge National Laboratory, the National Institute of Standards and Technology, the Air Barrier Association of America, and the US-China Clean Energy Research Center for Building Energy Efficiency Consortium partnered to develop an online calculator that estimates the potential energy savings in major US, Canadian, and Chinese cities due to improvements in airtightness. This tool will have user-friendly graphical interface that uses a database of CONTAM-EnergyPlus pre-run simulation results, and will be available to the public at no cost. Baseline leakage rates are either user-specified or the user selects them from the supplied typical leakage rates. Users will enter the expected airtightness after the proper installation of an air barrier system. Energy costs are estimated based on the building location and inputs from users. This paper provides an overview of the methodology that is followed in this calculator, as well as results from an example. The successful deployment of this calculator could influence construction practices so that greenhouse gas emissions from the US, Canada, and China are significantly curtailed.

air leakage↗

Modeling and Validation of a Residential Multi-Functional Variable Refrigerant Flow Heat Pump System with Heat Recovery

To bridge the existing gap in modeling the variable refrigerant flow heat pump systems with heat recovery (VRFHR), we developed a suite of dynamic VRFHR system models in Modelica. These models are specifically tailored for residential multi-functional VRFHR (MF-VRFHR) applications, including space conditioning and domestic hot water (DHW) heating, utilizing both the TIL library for HVAC equipment and the Buildings library for thermal load calculations. The development comprises essential component models, including the newly developed heat recovery unit (HRU), along with system models that integrate the heat pump system and building envelope. These system models accommodate various operational modes such as heating-only, cooling-only, and heating-recovery (including heating-dominant and cooling-dominant) modes. Furthermore, we propose an efficient optimization-based model calibration method that identifies critical model parameters while utilizing a small amount of data obtained from either real systems or manufacturer's specifications. We demonstrate the effectiveness of these models and the proposed calibration method for a MF-VRFHR system installed in Richland, WA. The developed models are calibrated and validated using data collected under different operational modes during both heating and cooling seasons. The results show that the models capture the system dynamics and achieve high accuracy, with the coefficient of the variation of the root-mean-square-error less than 15% for variables such as outdoor unit power consumption, compressor speed, space temperature and DHW temperature. The validated models serve as a reliable representation of the MF-VRFHR system, facilitating the development and validation of optimized controls needed to realize the full benefits of integrated heat pump systems. Future research will utilize these models to develop advanced controls and optimize system performance for improved energy efficiency and demand flexibility.

Modeling, Variable refrigerant flow (VRF) systems,↗

Side-by-Side Field Evaluation of Highly Insulating Windows in the PNNL Lab Homes

To examine the energy, air leakage, and thermal performance of highly insulating windows, a field evaluation was undertaken in a matched pair of all-electric, factory-built “Lab Homes” located on the Pacific Northwest National Laboratory (PNNL) campus in Richland, Washington. The “baseline” Lab Home B was retrofitted with “standard” double-pane clear aluminum-frame slider windows and patio doors, while the “experimental” Lab Home A was retrofitted with Jeld-Wen® triple-pane vinyl-frame slider windows and patio doors with a U-factor of 0.2 and solar heat gain coefficient of 0.19. To assess the window, the building shell air leakage, energy use, and interior temperatures of each home were compared during the 2012 winter heating and summer cooling seasons. The measured energy savings in Lab Home B averaged 5,821 watt-hours per day (Wh/day) during the heating season and 6,518 Wh/day during the cooling season. The overall whole-house energy savings of Lab Home B compared to Lab Home A are 11.6% ± 1.53% for the heating season and 18.4 ± 2.06% for the cooling season for identical occupancy conditions with no window coverings deployed. Extrapolating these energy savings numbers based on typical average heating degree days and cooling degree days per year yields an estimated annual energy savings of 12.2%, or 1,784 kWh/yr. The data suggest that highly insulating windows are an effective energy-saving measure that should be considered for high-performance new homes and in existing retrofits. However, the cost effectiveness of the measure, as determined by the simple payback period, suggests that highly insulating window costs continue to make windows difficult to justify on a cost basis alone. Additional reductions in costs via improvements in manufacturing and/or market penetration that continue to drive down costs will make highly insulating windows much more viable as a cost-effective energy efficiency measure. This study also illustrates that highly insulating windows have important impacts on peak load, occupant comfort, and condensation potential, which are not captured in the energy savings calculation. More consistent and uniform interior temperature distributions suggest that highly insulated windows, as part of a high performance building envelope, may enable more centralized duct design and downsized HVAC systems. Shorter, more centralized duct systems and smaller HVAC systems to yield additional cost savings, making highly insulating windows more cost effective as part of a package of new construction or retrofit measures which achieve significant reductions in home energy use.

PNNL Lab Homes↗

THE EFFECT OF THE {sup 14}N(p, {gamma}){sup 15}O REACTION ON THE BLUE LOOPS IN INTERMEDIATE-MASS STARS

We present stellar evolutionary sequences of stars in the mass range 5-12 M{sub Sun }, having solar-like initial composition. The stellar models are obtained using updated input physics, including recent rates of thermonuclear reactions. We investigate the effects of a modification of the {sup 14}N(p, {gamma}){sup 15}O reaction rate, as suggested by recent evaluations, on the formation and extension of the blue loops encountered during the evolution of the stars in the above mass range. We find that a reduced {sup 14}N(p, {gamma}){sup 15}O rate, as described in the text, has a striking impact on the physical conditions of burning and mixing during shell hydrogen burning when the blue loops are formed. In particular, we find that the efficiency of shell hydrogen burning is crucial for the formation of an extended blue loop. We show that a significantly reduced {sup 14}N(p, {gamma}){sup 15}O rate affects severely the extension of the blue loops and the time spent by the star in the blue part of the Hertzsprung-Russell diagram in the mass range 5-7 M{sub Sun} if the treatment of convection is based on the Schwarzschild criterion only. In this case, envelope overshooting helps to restore well-extended blue loops as supported by the observations of the Cepheid stars. If core overshooting is included during the core hydrogen and core helium burning phases, the loop formation and its properties depend on how this overshooting is treated for a given stellar mass range, as well as on its efficiency.

79 ASTRONOMY AND ASTROPHYSICS↗

WBG-Enabled Current-Source Inverters for Integrated PM Motor Drives

This project takes advantage of the special capabilities of wide-bandgap (WBG) power semiconductor devices to develop innovative power electronics in the form of new current-source inverters (CSIs) that offer promising advantages over the dominant voltage-source inverter (VSI) topology. These CSIs, in turn, are extremely well-suited for integration into the housings of permanent magnet synchronous machines (PMSMs) to form integrated motor drives (IMDs). These new IMDs offer great promise for achieving major energy savings in a wide variety of applications that benefit from adjustable-speed control, including air conditioners, laundry appliances, industrial pumps/compressors, electric vehicles, and aerospace drives. WBG devices play a critical enabling role in these new IMDs because of their transformative features including much higher switching frequencies, lower losses, and compatibility with high operating temperatures. When incorporated into new CSI-based IMDs with PM machines, these WBG switches open the door to achieving major increases in power density, drive system efficiency, and fault tolerance, as well as substantial reductions in electromagnetic interference (EMI), manufacturing cost, and temperature-induced failures. The higher operating temperature capability of WBG devices compared to conventional silicon power devices is very appealing in IMD applications because the power electronics is mounted in close proximity to the motors which typically operate at temperatures well above the maximum limits of today’s silicon-based power electronics. This project has succeeded in designing, building, and testing multiple prototype versions of this CSI-IMD that have overcome many technical challenges in order to demonstrate the impressive performance improvements that can be achieved by the WBG-enabled CSI-IMD. The preliminary demo and bench-top versions of the current-source inverter developed during the first two years of the project were critical to laying the technical foundations for the 3 kW prototype CSI-IMD unit that was successfully built and tested during the third year. This prototype CSI-IMD unit was designed to fit within the housing envelope of the original permanent magnet (PM) synchronous machine in order to meet the demanding power density requirements that were set at the beginning of the project. All of the remaining performance objectives set for the prototype CSI-IMD unit including efficiency and electromagnetic interference (EMI) were also met. The last 18 months of the project were devoted to developing further enhancements of the WBG-enabled CSI-IMD technology that better prepare it for commercial production. More specifically, an upgraded version of the prototype CSI-IMD unit was developed that moved the power electronics into the same machine housing chamber as the motor, substantially raising the thermal demands on the power electronics. Tests with five different combinations of motor enclosure types and air cooling configurations were evaluated. Importantly, this work confirmed that the power electronics can deliver its full rated power and still operate well within its maximum temperature limits even for worst-case conditions when the housing is “totally-enclosed” without any openings for air to enter or exit the enclosure, and no blower/fan is provided to blow air over the outside surface of the enclosure. Reaching the full performance and energy-savings potential of this disruptive CSI-IMD motor drive technology is highly consistent with ARPA-E’s stated mission to “enhance the economic and energy security of the United States” while also supporting its commitment to “ensure that the U.S. maintains a technological lead in developing and deploying advanced energy technologies”. Follow-on projects are under way to explore the scalability of WBG-enabled CSI-IMD technology to 100 kW (peak) electric vehicle traction drives and fault-tolerant modular motor drives for future electrified aircraft propulsion applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effects of dust formation on chemical abundances

Gas-phase abundances of C, Mg, Si, Ca, and Fe have been measured for a number of planetary nebulae on the basis of optical, ultraviolet, and infrared emission-line intensities. The abundances of Si, Ca, and Fe show characteristic depletions of one to two orders-of-magnitude as a result of grain formation. Magnesium shows a similar depletion in the outer parts of several planetary nebulae, but it is undepleted in their inner parts. Carbon is not detectably depleted by grain formation. Efficient condensation of refractory elements can easily occur during the early stages of formation of a planetary nebula; but the observed, residual gas-phase abundances are not understood. Observations of molecules in the envelopes of late-type stars may provide useful clues.

Shields, G. A.↗

Crew Autonomy through Self-Scheduling: Guidelines for Crew Scheduling Performance Envelope and Mitigation Strategies

Future long duration exploration missions (LDEMs) bring new challenges to astronaut crews in deep space, one of which is increased communication latencies with ground stations. As a result, crews will have to behave more autonomously by self-scheduling their own operational timelines in an efficient and effective manner. To support crew autonomy, our team has spent the last few years developing Playbook, a mission planning and scheduling tool. Our research focuses on investigating scheduling performance using Playbook to inform the deployment of novel aids that streamline the timeline creation process and proposing relevant standards and guidelines for autonomous crews in LDEMs. Summarizing yearly progress of research analysis and experiment in HERA.

user experience↗

Effects of changes in convective efficiency on the solar radius and luminosity

A sequence of solar models has been constructed in order to investigate the sensitivity of the solar radius and luminosity to small changes in the ratio alpha of the mixing length lambda to the pressure-scale height Hp throughout the solar convective envelope. The basic procedure for determining this sensitivity was to impose a perturbation in alpha within the convective envelope and then to follow the resulting changes in the solar radius delta R and luminosity delta L for the next 10 to the 6th power yrs. These calculations gave the following results. (1) A perturbation in alpha produces immediate changes in the solar radius and luminosity. Initially delta L and delta alpha are related by delta L/L = 0.30 delta alpha/alpha. (2) The value of the ratio w = delta log R/delta log L is strongly time dependent. Its value just after the perturbation in alpha is 6.5 x 10 to the minus 4th power. (3) The ratio H = (delta log L) d delta log R/dt is much less time dependent and is a more suitable means for relating the changes in the solar radius and luminosity. (4) Both of these ratios imply that for any reasonable change in the solar luminosity the corresponding change in the solar radius is negligible.

Sweigart, A. V.↗

Online Learning for Commercial Buildings

There has been an increased interest in designing optimization based techniques for the control of building heating, ventilation, and air-conditioning (HVAC) systems for either improving the energy efficiency of buildings or providing ancillary services to the electric grid. The performance of such prediction-based control techniques heavily rely on the model of a building’s thermal dynamics. However, the development of high fidelity building thermal dynamic models is challenging given the presence of large uncertainties that affect thermal loads in buildings such as building envelope performance, thermal mass, internal heat gains as well as occupants' behavior. In this paper, we propose a method to identify both a resistive-capacitive parametric model, and non -parametric load uncertainties using measured input-output data. The parametric model is obtained using semi-parametric regression, whereas the non-parametric part is based on Random Forest, where regression trees are used to derive the dependency of non-parametric terms on both building operation parameters and ambient temperature. The effectiveness of the method is evaluated using experimental data collected from an office building at the Pacific Northwest National Laboratory (PNNL) campus. The proposed methodology was observed to provide improved accuracy over appropriate baseline strategies, when predicting indoor air temperatures.

Dong, Jin↗

ALMA Cycle 1 observations of the HH 46/47 molecular outflow: structure, entrainment, and core impact

We present Atacama Large Millimeter/sub-millimeter Array Cycle 1 observations of the HH 46/47 molecular outflow using combined 12 m array and Atacama Compact Array observations. The improved angular resolution and sensitivity of our multi-line maps reveal structures that help us study the entrainment process in much more detail and allow us to obtain more precise estimates of outflow properties than in previous observations. We use {sup 13}CO (1–0) and C{sup 18}O (1–0) emission to correct for the {sup 12}CO (1–0) optical depth to accurately estimate the outflow mass, momentum, and kinetic energy. This correction increases the estimates of the mass, momentum, and kinetic energy by factors of about 9, 5, and 2, respectively, with respect to estimates assuming optically thin emission. The new {sup 13}CO and C{sup 18}O data also allow us to trace denser and slower outflow material than that traced by the {sup 12}CO maps, and they reveal an outflow cavity wall at very low velocities (as low as 0.2 km s{sup −1} with respect to the core’s central velocity). Adding the slower material traced only by {sup 13}CO and C{sup 18}O, there is another factor of three increase in the mass estimate and 50% increase in the momentum estimate. The estimated outflow properties indicate that the outflow is capable of dispersing the parent core within the typical lifetime of the embedded phase of a low-mass protostar and that it is responsible for a core-to-star efficiency of 1/4 to 1/3. We find that the outflow cavity wall is composed of multiple shells associated with a series of jet bow-shock events. Within about 3000 au of the protostar the {sup 13}CO and C{sup 18}O emission trace a circumstellar envelope with both rotation and infall motions, which we compare with a simple analytic model. The CS (2–1) emission reveals tentative evidence of a slowly moving rotating outflow, which we suggest is entrained not only poloidally but also toroidally by a disk wind that is launched from relatively large radii from the source.

79 ASTRONOMY AND ASTROPHYSICS↗

An Energy Calculator for Simple Commercial Buildings

According to the EIA, simple commercial buildings account for 97% of total commercial building stock. However, most simple commercial buildings for example small- to mid-sized offices, retail, schools and warehouses do not benefit from the data-driven decision-making capabilities of whole-building energy modeling. The high cost of custom modeling limits the use of energy modeling of simple buildings for new construction or retrofit measures. Lack of tools providing helpful information on interactive savings estimates creates difficulties in meeting aggressive decarbonization and energy efficiency goals for simple building designers and utility program managers. This paper reviews a beta phase Simple Building Calculator with the ability to generate relatively accurate and interactive modeling results based on a limited but robust set of inputs. It can evaluate whole-building or single measure savings in new or existing buildings, compare measure package choices, or provide simplified performance modeling for energy codes and utility incentives. The tool combines physical (annual whole building prototype simulation) and statistical modeling techniques to predict annual energy performance. It supports a variety of building characteristics for envelope, HVAC, and lighting with parameters ranging from vintage to max tech configurations, as well as support for single-zone and simple multi-zone HVAC systems. The Simple Building Calculator was designed to provide immediate feedback for otherwise computationally intensive tasks like measure comparison, development of multiple measure package combinations, or verification that measures meet efficiency targets—all with the goal of providing a tool for quick annual energy simulation of simple commercial buildings.

Hart, Reid↗

Graphene reinforced UHMWPE fibers

Thermoplastic polymers are increasingly used in electric vehicles, hydrogen fuel cell vehicles, and other decarbonization applications due to their lightweight and formability. Higher-strength polymers are needed to supplant metals in the vehicle structure, thereby reducing mass and improving efficiency. Ultra-high molecular weight polyethylene (UHMWPE) fibers possess one of the highest strength-to-weight ratios of technical polymers, and further improvement via reinforcement by nanofillers, such as graphene, will expand their performance envelope. Here, in this work, UHMWPE/graphene nanocomposite fibers were gel spun and characterized for their morphological, microstructural, thermal, and mechanical properties. The addition of a low fraction of graphene improved the tensile strength of the fibers by 25% and tensile modulus by 32%. Differential scanning calorimetry showed an increase in melting temperature and degree of crystallinity, which indicates improved coordination of the molecular chains induced by the addition of graphene. The reinforcement also affected the cross-sectional shape of the fibers; the aspect ratio of the fibers’ elliptical shape declined with increasing graphene content showing the skeletal effect of the graphene nanofillers in the polymer matrix. The reinforcing effect of graphene declined above a threshold concentration, and theoretical modeling was applied to demonstrate that increased agglomerates led to reduced properties. This work demonstrates a simple, effective method to produce graphene-reinforced UHMWPE fibers and lays a foundation for understanding the potential for leveraging graphene to form ultra-high-performance nanocomposite fibers for myriad engineering applications.

36 MATERIALS SCIENCE↗

Chapter 7: Principles of Northern Housing Design with Examples from Alaska

The Arctic has unique challenges and needs with respect to housing due to extreme climate, remoteness of communities, cultural aspects, and other factors. Attempts to adopt designs from other regions often resulted in failures, such as rotten building envelopes or features incompatible with local values. The main goal of this chapter is to inform a broad audience involved in northern housing about basic principles important for the Arctic. Particular attention is given to energy efficiency, health and durability, foundations appropriate for the underlying terrain such as permafrost, inclusive design process to assure meeting cultural and other needs and building design factoring in seasonality and logistical challenges of remote communities. Examples of existing prototype homes are given throughout the chapter to demonstrate how the individual principles can be successfully applied in real-life scenarios. This chapter also covers current trends, what the future might look like, how it is informed by indigenous perspectives, and how northern housing design can influence approaches in other regions of the world. The ultimate goal is to contribute to a vibrant future of communities in the Arctic and beyond.

Arctic↗