Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Fabrication of a Nb-Ti Superconducting Closed-Loop Coil for the Next-Generation 45 GHz ECR Ion Source MARS-D

Electron Cyclotron Resonance Ion Sources (ECRISs) that utilize Nb-Ti superconducting coils for 28 GHz frequencies have been operating effectively for over twenty years. However, transitioning to higher frequencies demands stronger magnetic fields, and the conventional racetrack-and-solenoid ECRIS structures have reached their maximum capability with Nb-Ti. To address this, a Mixed Axial and Radial field System Demonstrator (MARS-D) is being developed at Lawrence Berkeley National Laboratory (LBNL). This system features an innovative Closed-Loop Coil (CLC) design that optimizes the use of the conductor fields, enabling the application of Nb-Ti in the next-generation 45 GHz ECRISs. The fabrication of the hexagonal CLC is particularly challenging due to its complex winding path and shape, the stiffness of the Nb-Ti superconducting wire, and the small bending radius. Here, to address these challenges, a series of unique fixtures and tools, as well as a pre-over-bending method, were developed for winding the CLC. To validate the winding fixtures, tools, procedures, and materials used in the coil assembly, a 4-layer practice CLC was wound, epoxy-impregnated, and then cold-tested using liquid nitrogen. The full-size MARS-D CLC is in the process of winding. This paper presents the structure of the MARS-D CLC, the winding fixtures and tools, the winding procedures, the quality control, the impregnation, the test results, and the potential future improvements.

ECR ion sources↗

A Miniaturized Linear Wire Ion Trap with Electron Ionization and Single Photon Ionization Sources

A linear wire ion trap (LWIT) with both electron ionization (EI) and single photon ionization (SPI) sources was built. The SPI was provided by a vacuum ultraviolet (VUV) lamp with the ability to softly ionize organic compounds. The VUV lamp was driven by a pulse amplifier, which was controlled by a pulse generator, to avoid the detection of photons during ion detection. Sample gas was introduced through a leak valve, and the pressure in the system is shown to affect the signal-to-noise ratio and resolving power. Under optimized conditions, the limit of detection (LOD) for benzene was 80 ppbv using SPI, better than the LOD using EI (137 ppbv). System performance was demonstrated by distinguishing compounds in different classes from gasoline. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A High Intensity Spin-Polarized Electron Photogun to Drive a Polarized Positron Source

A photogun to generate a high-intensity, highly spin-polarized electron beam >90% with unprecedented charge lifetime in the kilocoulomb range is envisioned at JLab for a proposed Ce+BAF polarized positron beam source. The electron photogun is expected to provide a CW beam of >1 mA for a month without intervention. A limiting factor is ion-back bom-bardment on the strained-superlattice GaAs-photocathode which can be reduced by improving the photogun vacuum or biasing the anode. Additionally, increasing the laser spot size can help mitigate ion-induced damage. However, eventually the laser size becomes too large for the photogun electrode. An envisioned photogun design will incorporate larger electrodes to accommodate larger and off-center laser spot sizes. Compatible larger conical insulators which operate >300 kV for beam injection into a Beta~1 SRF booster are also necessary.

Hernandez Garcia, Carlos↗

Tunable High Spatio-Spectral Purity Undulator Radiation from a Transported Laser Plasma Accelerated Electron Beam

Undulator based synchrotron light sources and Free Electron Lasers (FELs) are valuable modern probes of matter with high temporal and spatial resolution. Laser Plasma Accelerators (LPAs), delivering GeV electron beams in few centimeters, are good candidates for future compact light sources. However the barriers set by the large energy spread, divergence and shot-to-shot fluctuations require a specific transport line, to shape the electron beam phase space for achieving ultrashort undulator synchrotron radiation suitable for users and even for achieving FEL amplification. Proof-of-principle LPA based undulator emission, with strong electron focusing or transport, does not yet exhibit the full specific radiation properties. We report on the generation of undulator radiation with an LPA beam based manipulation in a dedicated transport line with versatile properties. After evidencing the specific spatio-spectral signature, we tune the resonant wavelength within 200–300 nm by modification of the electron beam energy and the undulator field. We achieve a wavelength stability of 2.6%. We demonstrate that we can control the spatio-spectral purity and spectral brightness by reducing the energy range inside the chicane. We have also observed the second harmonic emission of the undulator.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cosmic electrons

The published literature on cosmic electrons is summarized. The primary and secondary sources of cosmic electrons are discussed, and the propagation of the electrons in the interstellar medium is studied with respect to energy loss mechanisms, age distributions, and spectral modifications during flight. Various portions of the electron and positron spectra are then considered in relation to problems of astrophysics. New information is presented on such topics as the origin of low-energy positrons, the decay kinematics of the pi-mu-e process, the application of age distributions for nuclear cosmic rays to cosmic electrons, and the possibility of nonidentical sources for cosmic electrons and protons.

Ramaty, R.↗

Gyrokinetic benchmark of the electron temperature-gradient instability in the pedestal region

Transport from turbulence driven by the electron temperature-gradient (ETG) instability is likely a major source of electron heat losses through the pedestal. Due to extreme gradients and strong shaping, ETG instabilities in the pedestal are distinct from those in the core, having, for example, multiple branches (toroidal and slab) in different wavenumber ranges. Due to its importance for pedestal transport, and its rather exotic character, a rigorous multi-code benchmarking exercise is imperative. In this work, we describe such an exercise, wherein we have carried out a detailed comparison of local linear pedestal ETG simulations using three gyrokinetic codes, CGYRO, GEM, and GENE and testing different geometric parameters (such as circular, Miller, and equilibrium EFIT geometry). The resulting linear frequencies, growth rates, and eigenfunctions show very good agreement between the codes in the three types of employed geometries. A nonlinear benchmark between CGYRO and GENE is also described, exhibiting good agreement (a maximum of 20% difference in the heat fluxes computed) at two locations in the pedestal. This lays the foundation for confidently modeling ETG turbulence in the pedestal

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Theoretical light curve of a Type 2p supernova

The light curve and other observable diagnostics are presented for what should be a typical Type II 'plateau' supernova, the explosion of a 15 solar mass red supergiant. The calculations are carried out using a multi-frequency radiation transport code that includes opacity from all important mechanisms-bound-bound, bound-free, free-free, and electron scattering. It is found that the inclusion of opacity sources besides electron scattering increases the computed lenght of the plateau in the 15 solar mass model by approximately 30 days. Especially important is the ultraviolet cutoff caused by a thick forest of lines. Deposition and escape of gamma-rays from radioactive decay are also accurately simulated. We find that the presence of 0.06 solar mass of ejected Ni-56 extends the length of the plateau from approximately 100 days to approximately 140 dys. Because of the large hydrogen envleope and radius in this model, mixing does not appreciably alter the bolometric light curve, although it does change the gamma-ray light curve significantly. With 0.06 solar mass of ejected Ni-56, the unmixed (mixed) model peaks in escaping gamma-rays at 576 (466) days with gamma-ray luminosity of 3 x 10(exp 38) ergs/s. Except for the local group, the gamma-rays from an extragalactic 15 solar mass SNe IIp will be too faint to detect with any exsiting detectors. However, a Galactic SNe IIp would be quite bright and easily detectable.

Eastman, Ronald G.↗

Comparative Study of Nonlinear Black-Box Modeling for Power Electronics Converters

With the increasing penetration level of renewable sources and power electronics loads in modern power systems, accurate and computationally efficient models are needed. Black-box model (BBM) could be a useful method in such systems. However, not very extensive research efforts have been made for power electronics BBM so far, and existing works mostly focus on steady-state operation, neglecting the important transient behaviors such as load transients, voltage transients, and faults. This paper presents a comparative study of three commonly used nonlinear BBM approaches for transient behaviors of power electronics converters. Comparison methods are proposed, and the evaluations are conducted under different transients using a grid-connected single-phase photovoltaic inverter. The findings of this study provide valuable references for further feasibility investigations on implementing BBMs in large-scale power electronics-rich power systems.

Qiao, Liang↗

Surface plasmon enhanced fast electron emission from metallised fibre optic nanotips

Physical mechanisms of electron emission from fibre optic nanotips, namely, tunnelling, multi-photon, and thermionic emission, either prevent fast switching or require intense laser fields. Time-resolved electron emission from nano-sized sources finds applications ranging from material characterisation to fundamental studies of quantum coherence. We present a nano-sized electron source capable of fast-switching (≤1 ns) that can be driven with low-power femtosecond lasers. The physical mechanism that can explain emission at low laser power is surface plasmon enhanced above-threshold photoemission. An electron emission peak is observed and provides support for resonant plasmonic excitation. The electron source is a metal-coated optical fibre tapered into a nano-sized tip. The fibre is flexible and back illuminated facilitating ease of positioning. The source operates with a few nJ per laser pulse, making this a versatile emitter that enables nanometrology, multisource electron-lithography and scanning probe microscopy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The KATRIN superconducting magnets: Overview and first performance results

The KATRIN experiment aims for the determination of the effective electron anti-neutrino mass from the tritium beta-decay with an unprecedented sub-eV sensitivity. The strong magnetic fields, designed for up to 6 T, adiabatically guide β-electrons from the source to the detector within a magnetic flux of 191 Tcm 2 . A chain of ten single solenoid magnets and two larger superconducting magnet systems have been designed, constructed, and installed in the 70-m-long KATRIN beam line. The beam diameter for the magnetic flux varies from 0.064 m to 9 m, depending on the magnetic flux density along the beam line. Two transport and tritium pumping sections are assembled with chicane beam tubes to avoid direct "line-of-sight" molecular beaming effect of gaseous tritium molecules into the next beam sections. The sophisticated beam alignment has been successfully cross-checked by electron sources. In addition, magnet safety systems were developed to protect the complex magnet systems against coil quenches or other system failures. The main functionality of the magnet safety systems has been successfully tested with the two large magnet systems. The complete chain of the magnets was operated for several weeks at 70% of the design fields for the first test measurements with radioactive krypton gas. The stability of the magnetic fields of the source magnets has been shown to be better than 0.01% per month at 70% of the design fields. This paper gives an overview of the KATRIN superconducting magnets and reports on the first performance results of the magnets.

47 OTHER INSTRUMENTATION↗

Solving the auroral-arc-generator question by using an electron beam to unambiguously connect critical magnetospheric measurements to auroral images

Here, an active mapping mission is described that unambiguously connects measurements in the Earth's magnetosphere to visible aurora in the atmosphere. The core of the mission is an electron-beam source operated on a spacecraft in the equatorial magnetosphere, with the electron beam traveling along the Earth's magnetic-field lines to the atmosphere, depositing its energy to create an optical beam-spot in the atmosphere at the footpoint of the spacecraft's magnetic-field line. This optical spot can be imaged by ground-based cameras, putting the location of the spacecraft's magnetic footpoint into the context of the optical aurora. Scientific instruments carried on the spacecraft make critical measurements of the properties of the magnetosphere at the locations where the magnetosphere powers the aurora, allowing the determination of the plasma-physics mechanisms by which the magnetosphere drives the aurora, in particular answering the outstanding question of how the magnetosphere drives low-latitude auroral arcs. Long-standing questions in magnetosphere-ionosphere coupling that have not been answered because we could not unambiguously connect locations in the magnetosphere with their image in the ionosphere will finally be addressed. In this paper the properties of a “standard” growth-phase auroral arc are collected, theories of the magnetospheric generation of auroral arcs are reviewed, and critical magnetospheric measurements to discern the mechanisms that drive auroral arcs are determined. Further, the plasma physics of the experiment is investigated, including spacecraft-charging mitigation, beam stability, beam scattering, and electron orbit theory. Tradeoffs (keV versus MeV) concerning the energy of the electron beam are enumerated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Assessment of errors in analytic modeling of permanent magnet electron spectrometers for laser-plasma accelerators

Here, we assess the error in three treatments of a critical electron beam diagnostic for laser-plasma acceleration (LPA) experiments: a permanent magnet electron spectrometer. Since LPA electron spectrometers are often difficult to calibrate due to the scarcity of well-characterized, tunable electron beam sources in the appropriate energy range and the mechanical complexity of electron spectrometers, the standard of calibration is Hall probe measurements. We first compare the electron spectrometer performance between SIMION calculations and the Hall probe measurements. We find up to a 60% (<8%) error in determining the absolute energy for electrons below (above) 80 MeV when using the SIMION-modeled magnetic field vs the measured magnetic field due to SIMION overpredicting fringe field strength. The difference in spectrometer energy resolution is within ∼10% between the modeled and measured fields. We then assess a simple block model, which is commonly used. We find that the simple block model presented here sufficiently captures the predicted as-built spectrometer performance for any application provided that the user can tolerate uncertainties on absolute energy determination up to 5% and errors on energy resolution up to 1%.

Electromagnetic optics↗

Observations of Jovian electrons at 1 AU throughout the 13 month Jovian synodic year

A study of Jovian electron-flux increases observed aboard the IMP-8 earth-orbiting satellite reveals that, contrary to previous reports of a 4-8-month Jovian electron 'season', Jovian electron-intensity increases were observed almost continuously from late 1973 into 1976, with peak intensities occurring at times of best connection between earth and Jupiter along the average direction of the interplanetary magnetic field about every 13 months. These observations are consistent with Jovian electron propagation both along and across the direction of the average interplanetary magnetic field. A convection-diffusion model for Jovian electron propagation, which assumes that Jupiter is a continuously emitting point source of electrons, originally developed to explain the distribution of Jovian electrons observed on the Pioneer 10 and 11 spacecraft, can account also for the distribution of Jovian electrons observed at the orbit of earth.

Chenette, D. L.↗

Energetic electrons in the magnetophere of Saturn

The energy spectra and angular distributions of electrons observed by Pioneer 11 as a function of radial distance in the inner magnetosphere of Saturn are reanalyzed and phase space densities are then calculated. The radial dependence of phase space density requires a distributed loss process. The loss is greatest in the region of the E ring (5.5 less than L less than 8.5) and is attributed to collisions with the ring particles in agreement with earlier work by Van Allen et al. (1980b). Quantitative analysis yields the following properties of the E ring: the particle radii are in the range of 4 x 10(exp -5) to 3.2 x 10(exp -4) cm and the thickness of the ring is approximately 3 R(sub s). Between the inner edge of the E ring (5.5 R(sub s)) and the outer edge of the A ring (2.3 R(sub s)) there are more energetic electrons than can be supplied by radial diffusion from an external source. Detailed calculations show that a cosmic ray albedo neutron decay (CRAND) source in the A and B rings is a plausible source for this excess. The radial diffusion coefficient required to explain the E ring absorption and CRAND source for electrons is 1 x 10(exp -12) greater than D(sub 0) greater than 3 x 10(exp -12) R(sub s)(exp 2)/s, assuming that D(sub LL) = D(sub 0)L(exp 3). As part of the reanalysis program, a method for the deconvolution of pitch angle distributions observed by simple detectors on a rotating spacecraft is developed. This process removes the instrumental response and rotational smear due to finite sampling periods and yields true angular distributions.

Randall, B. A.↗

Energetic electrons in the magnetosphere of Saturn

The energy spectra and angular distributions of electrons observed by Pioneer 11 as a function of radial distance in the inner magnetosphere of Saturn are reanalyzed and phase space densities are then calculated. The radial dependence of phase space density requires a distributed loss process. The loss is greatest in the region of the E ring (5.5 less than L less than 8.5) and is attributed to collisions with the ring particles in agreement with earlier work by Van Allen et al. (1980). Quantitative analysis yields the following properties of the E ring: the particle radii are in the range of 4 x 10(exp -5) to 3.2 x 10(exp -4) cm and the thickness of the ring is approximately 3 R(sub s). Between the inner edge of the E ring (5.5 R(sub s)) and the outer edge of the A ring (2.3 R(sub s)) there are more energetic electrons than can be supplied by radial diffusion from an external source. Detailed calculations show that a cosmic ray albedo neutron decay (CRAND) source in the A and B rings is a plausible source for this excess. The radial diffusion coefficient required to explain the E ring absorption and CRAND source for electrons is 1 x 10(exp -12) greater than D(sub 0) greater than 3 x 10(exp -12) R(exp 2, sub s)/s, assuming that D(sub LL) = D(sub 0)L(exp 3). As part of the reanalysis program, a method for the deconvolution of pitch angle distributions observed by simple detectors on a rotating spacecraft is developed. This process removes the instrumental response and rotational smear due to finite sampling periods and yields true angular distributions.

Randall, B. A.↗

Phase-Space Manipulations of Electron Beams for X-Ray Free-Electron Lasers and Inverse Compton Scattering Sources [Thesis]

This dissertation describes advanced techniques of phase space manipulations of the electron beam for improving performance and efficiency of high brightness X-ray light sources based on the free-electron Laser (FEL) and inverse-Compton scattering (ICS) processes. In particular, it first discusses a novel bunch-compression scheme based on a double transverseto-longitudinal phase-space exchanger – dubbed emittance exchanger (EEX) – separated by a demagnifying transverse-optics system. While the outline of the scheme is quite sophisticated, the basic physics behind it is quite straight-forward. The benefits and disadvantages of these scheme are compared to the conventional approach of compressing a bunch using a magnetic bunch-compression chicane.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An investigation of accelerating mode and decelerating mode constant-momentum mass spectrometry and their application to a residual gas analyzer

A theoretical analysis of constant momentum mass spectrometry was made. A maximum resolving power for the decelerating mode constant momentum mass spectrometer was shown theoretically to exist for a beam of ions of known energy. A vacuum system and an electron beam ionization source was constructed. Supporting electronics for a residual gas analyzer were built. Experimental investigations of various types of accelerating and decelerating impulsive modes of a constant momentum mass spectrometer as applied to a residual gas analyzer were made. The data indicate that the resolving power for the decelerating mode is comparable to that of the accelerating mode.

Ng, Y. S.↗

Adapting the Electron Beam from SEM as a Quantitative Heating Source for Nanoscale Thermal Metrology

The electron beam (e-beam) in the scanning electron microscopy (SEM) provides an appealing mobile heating source for thermal metrology with spatial resolution of ~1 nm, but the lack of systematic quantification of the e-beam heating power limits such application development. Here, we systemically study e-beam heating in LPCVD silicon nitride (SiN x ) thin-films with thickness ranging from 200 to 500 nm from both experiments and complementary Monte Carlo simulations using the CASINO software package. There is good agreement about the thickness-dependent e-beam energy absorption of thin-film between modeling predictions and experiments. Using the absorption results, we then demonstrate adapting the e-beam as a quantitative heating source by measuring the thickness-dependent thermal conductivity of SiN x thin-films, with the results validated to within 7% by a separate Joule heating experiment. The results described here will open a new avenue for using SEM e-beams as a mobile heating source for advanced nanoscale thermal metrology development.

42 ENGINEERING↗