Cost-Benefit Analysis of the 2021 Washington State Energy Code – Commercial Provisions

The state of Washington recently updated their current state commercial energy code, which is the 2018 Washington State Energy Code (2018 WSEC-C) to an updated version named the 2021 WSEC-C. This report assesses the life cycle costs and savings and greenhouse gas emissions impacts of the 2021 WSEC-C compared to the 2018 WSEC-C, as requested by the Washington State Building Code Council (SBCC).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

U.S. Department of Energy Solar Decathlon Visitors Guide 2015

The U.S. Department of Energy 2015 Visitors Guide is a free, hard-copy publication distributed free to those attending the Solar Decathlon event. The publications' objectives are to serve as the primary information resource for those in attendance, and to deliver a compelling message about the Solar Decathlon's success as a proven workforce development program and its role in educating students and the public about clean energy products and design solutions. The U.S. Department of Energy 2015 Visitors Guide SD15 Visitors Guide goals are to guide attendees through the Solar Decathlon village; List and explain the 10 contests; educate attendees about the participating teams and their competition houses; provide access to more information on the Solar Decathlon website through the use of QR codes; and acknowledge the support of all event sponsors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Total System Performance Ratio—A Systems Based Approach for Evaluating HVAC System Efficiency

The prescriptive path is the most widely used approach for commercial code compliance in the United States. Though easy to implement, prescriptive approaches do not typically discriminate between minimally compliant, high-performing and poorly performing HVAC system configurations. Hence, to meet aggressive energy and carbon reduction goals, it is clear that energy codes will need to transition from prescriptive to performance-based approaches, a transition that is riddled with several challenges. This paper discusses a new HVAC system-based performance approach (HVAC System Performance) which provides a simpler solution to HVAV system evaluation compared to whole building performance, while keeping tradeoffs limited to specific building systems. The Total System Performance Ratio (TSPR) is a metric for evaluation of overall system efficiency instead of individual component efficiency, a solution which could also eventually facilitate the transition to a 100% performance-based code structure. TSPR is a ratio that compares the annual heating and cooling load of a building to the annual energy consumed by the building’s HVAC system. A calculation software tool has been developed for determining a building’s TSPR. Already incorporated into the 2018 Washington State Energy Code, this approach is also being evaluated by ASHRAE Standard 90.l Project Committee and has the potential to provide a comprehensive performance-based approach for HVAC system evaluation and analysis.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Community College Energy Code Training Program

The U.S. Department of Energy (DOE) Office of Energy Efficiency and Renewable Energy (EERE) funded a series of research and training programs under the Advanced Building Construction with Energy Efficient Technologies and Practices (ABC) initiative. The aim is to develop new training programs to support the development of a skilled workforce in the building energy efficiency industry. In response, the University of Illinois Smart Energy Design Assistance Center (SEDAC), in collaboration with State Energy Offices in Illinois, Hawaii, and Nevada, developed the Community College Energy Code Training Program. The program is designed to prepare a new generation of energy-literate professionals that understand energy efficiency and its relation to energy codes for new construction and existing buildings through: a) the development of a curriculum and innovative pedagogical materials, b) dissemination through a national network of state energy offices: c) outreach targeting Community College students and instructors.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Building Energy Codes Program: National Benefits Assessment (1992-2040)

Building energy codes and standards set minimum requirements for energy-efficient design and construction for new and renovated buildings, assuring reductions in energy use and greenhouse gas emissions over the life of buildings. DOE, through the Building Energy Codes Program, supports the improvement of energy efficiency in buildings. BECP periodically assesses the impacts of its activities by estimating historical and projected energy savings, consumer savings, and avoided emissions. The Pacific Northwest National Laboratory conducted the codes benefits assessment in support of the BECP. Underlying the assessment is a series of calculations that estimate and compare energy savings under two scenarios: "with BECP" and "without BECP." The analysis covers the years 1992-2040 and includes comparing the nominal energy savings (assuming 100 percent adoption and compliance) attributable to different code versions, determining the applicable floor space (both residential and commercial) subject to the code, and estimating the final energy savings by adjusting nominal energy savings for the applicable floor space according to the estimated actual adoption and compliance levels. The resulting estimates of energy consumption for each scenario are compared, and the difference equals the impact of BECP activities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Beam Loading in the Nonlinear Regime of Plasma-Based Acceleration

A theory that describes how to load negative charge into a nonlinear, three-dimensional plasma wakefield is presented. In this regime, a laser or an electron beam blows out the plasma electrons and creates a nearly spherical ion channel, which is modified by the presence of the beam load. Analytical solutions for the fields and the shape of the ion channel are derived. It is shown that very high beam-loading efficiency can be achieved, while the energy spread of the bunch is conserved. The theoretical results are verified with the particle-in-cell code OSIRIS.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effects of Non-Equilibrium Chemistry and Darcy-Forchheimer Flow of Pyrolysis Gas for a Charring Ablator

The Fully Implicit Ablation and Thermal Response code, FIAT, simulates pyrolysis and ablation of thermal protection materials and systems. The governing equations, which include energy conservation, a three-component decomposition model, and a surface energy balance, are solved with a moving grid. This work describes new modeling capabilities that are added to a special version of FIAT. These capabilities include a time-dependent pyrolysis gas flow momentum equation with Darcy-Forchheimer terms and pyrolysis gas species conservation equations with finite-rate homogeneous chemical reactions. The total energy conservation equation is also enhanced for consistency with these new additions. Parametric studies are performed using this enhanced version of FIAT. Two groups of analyses of Phenolic Impregnated Carbon Ablator (PICA) are presented. In the first group, an Orion flight environment for a proposed Lunar-return trajectory is considered. In the second group, various test conditions for arcjet models are examined. The central focus of these parametric studies is to understand the effect of pyrolysis gas momentum transfer on PICA material in-depth thermal responses with finite-rate, equilibrium, or frozen homogeneous gas chemistry. Results are presented, discussed, and compared with those predicted by the baseline PICA/FIAT ablation and thermal response model developed by the Orion Thermal Protection System Advanced Development Project.

Ablation↗

Sealed Crawl Spaces with Integrated Whole-House Ventilation in a Cold Climate

One method of code-compliance for crawlspaces is to seal and insulate the crawlspace, rather than venting to the outdoors. However, codes require mechanical ventilation; either via conditioned supply air from the HVAC system, or a continuous exhaust ventilation strategy. As the CARB's building partner, Ithaca Neighborhood Housing Services, intended to use the unvented crawlspace in a recent

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dramatic Demand Reduction In The Desert Southwest

This report summarizes a project that was funded to the University of Nevada Las Vegas (UNLV), with subcontractors Pulte Homes and NV Energy. The project was motivated by the fact that locations in the Desert Southwest portion of the US demonstrate very high peak electrical demands, typically in the late afternoons in the summer. These high demands often require high priced power to supply the needs, and the large loads can cause grid supply problems. An approach was proposed through this contact that would reduce the peak electrical demands to an anticipated 65% of what code-built houses of the similar size would have. It was proposed to achieve energy reduction through four approaches applied to a development of 185 homes in northwest part of Las Vegas named Villa Trieste. First, the homes would all be highly energy efficient. Secondly, each house would have a PV array installed on it. Third, an advanced demand response technique would be developed to allow the resident to have some control over the energy used. Finally, some type of battery storage would be used in the project. Pulte Homes designed the houses. The company considered initial cost vs. long-term savings and chose options that had relatively short paybacks. HERS (Home Energy Rating Service) ratings for the homes are approximately 43 on this scale. On this scale, code-built homes rate at 100, zero energy homes rate a 0, and Energy Star homes are 85. In addition a 1.764 Wp (peak Watt) rated PV array was used on each house. This was made up of solar shakes that were in visual harmony with the roofing material used. A demand response tool was developed to control the amount of electricity used during times of peak demand. While demand response techniques have been used in the utility industry for some time, this particular approach is designed to allow the customer to decide the degree of participation in the response activity. The temperature change in the residence can be decided by the residents by adjusting settings. In a sense the customer can choose between greater comfort and greater money savings during demand response circumstances. Finally a battery application was to be considered. Initially it was thought that a large battery (probably a sodium-sulfur type) would be installed. However, after the contract was awarded, it was determined that a single, centrally-located battery system would not be appropriate for many reasons, including that with the build out plan there would not be any location to put it. The price had risen substantially since the budget for the project was put together. Also, that type of battery has to be kept hot all the time, but its use was only sought for summer operation. Hence, individual house batteries would be used, and these are discussed at the end of this report. Many aspects of the energy use for climate control in selected houses were monitored before residents moved in. This was done both to understand the magnitude of the energy flows but also to have data that could be compared to the computer simulations. The latter would be used to evaluate various aspects of our plan. It was found that good agreement existed between actual energy use and computed energy use. Hence, various studies were performed via simulations. Performance simulations showed the impact on peak energy usage between a code built house of same size and shape compared to the Villa Trieste homes with and without the PV arrays on the latter. Computations were also used to understand the effect of varying orientations of the houses in this typical housing development, including the effect of PV electrical generation. Energy conservation features of the Villa Trieste homes decreased the energy use during peak times (as well as all others), but the resulting decreased peak occurred at about the same time as the code-built houses. Consideration of the PV generation decreases the grid energy use further during daylight hours, but did not extend long enough many days to decrease the peak. Hence, a demand response approach, as planned, was needed. With participation of the residents in the demand response program developed does enable the houses to reduce the peak demand between 66% and 72%, depending on the built years. This was addressed fully in the latter part the study and is described in the latter part of this report.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Implementation of new PRODIAG algorithm and simulation-based acceptance test - 219

This paper presents the improvement of an automated-reasoning computer program for nuclear power plant diagnosis, namely PRODIAG. PRODIAG, first developed at the Argonne National Laboratory, uses confluence-based reasoning to perform fault diagnosis in engineering systems that can be described by the conservation laws for mass, energy, and momentum. Therefore, unlike other plant configuration-dependent rule-based diagnosis algorithms, the code is generally applicable to a wide variety of plant configurations by simply replacing the plant instrumentation diagram (PID) database. The need for improvement was raised when the original PRODIAG failed to provide the requisite degree of extensibility and maintainability for new applications. These shortcomings have been addressed through a new code architecture that uses an objected-oriented logic-programming language in place of the original Prolog language and uses an open-source automated reasoning engine in place of the original hardwired rule-evaluation sequence. This paper presents the architecture and implementation details of the code transition. Verification and validation studies were performed for the new PRODIAG, which involved re-running the distinct fault cases defined at the time the code was originally developed. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Solar Tarining for Design Professionals

The Building Codes Assistance Project (BCAP) at the Trust for Conservation Innovation (TCI – now renamed “Multiplier”) partnered with the Center for Sustainable Energy (CSE) to develop and deliver solar training workshops and reference materials to teach building design professionals (individuals involved professionally in architecture or building engineering) about the benefits and technical requirements of incorporating photovoltaics into their building designs. The goal of the project was to eliminate barriers to widespread solar acceptance and support strong growth in the solar sector. These workshops were delivered to design professionals in twenty-two cities, representing a range of small to large design firms. Participants were given pre- and post-training evaluations to gauge effectiveness of the training, and a three-month follow-up survey was used to study whether these workshops assisted in increasing the probability that a designer would incorporate photovoltaics into their building designs. This project produced a trained, experienced, and enthusiastic network of solar trainers and trained almost 600 design professionals. Project also created multiple long-lasting resources to help architects and engineers add solar expertise to their list of qualifications. This includes a full, online training course available long-term for continuing education credit from AIA University. The program was endorsed by the American Institute of Architects (AIA) and ASHRAE, the project partners. The trainings were accepted for continuing education credits from the International Codes Council, the AIA and the United States Green Building Council (USGBC).

14 SOLAR ENERGY↗

ENERGY CONSERVATION AND GRAVITY WAVES IN SOUND-PROOF TREATMENTS OF STELLAR INTERIORS. II. LAGRANGIAN CONSTRAINED ANALYSIS

The speed of sound greatly exceeds typical flow velocities in many stellar and planetary interiors. To follow the slow evolution of subsonic motions, various sound-proof models attempt to remove fast acoustic waves while retaining stratified convection and buoyancy dynamics. In astrophysics, anelastic models typically receive the most attention in the class of sound-filtered stratified models. Generally, anelastic models remain valid in nearly adiabatically stratified regions like stellar convection zones, but may break down in strongly sub-adiabatic, stably stratified layers common in stellar radiative zones. However, studying stellar rotation, circulation, and dynamos requires understanding the complex coupling between convection and radiative zones, and this requires robust equations valid in both regimes. Here we extend the analysis of equation sets begun in Brown et al., which studied anelastic models, to two types of pseudo-incompressible models. This class of models has received attention in atmospheric applications, and more recently in studies of white-dwarf supernova progenitors. We demonstrate that one model conserves energy but the other does not. We use Lagrangian variational methods to extend the energy conserving model to a general equation of state, and dub the resulting equation set the generalized pseudo-incompressible (GPI) model. We show that the GPI equations suitably capture low-frequency phenomena in both convection and radiative zones in stars and other stratified systems, and we provide recommendations for converting low-Mach number codes to this equation set.

79 ASTRONOMY AND ASTROPHYSICS↗

Halted-pendulum Relaxation: Application to White Dwarf Binary Initial Data

Studying compact-star binaries and their mergers is integral to determining progenitors for observable transients. Today, compact-star mergers are typically studied via state-of-the-art computational fluid dynamics codes. One such numerical technique, smoothed particle hydrodynamics (SPH), is frequently chosen for its excellent mass, energy, and momentum conservation. The natural treatment of vacuum and the ability to represent highly irregular morphologies make SPH an excellent tool for the study of compact-star binaries and mergers. For many scenarios, including binary systems, the outcome of simulations is only as accurate as the initial conditions. For SPH, it is essential to ensure that the particles are distributed regularly, representing the initial density profile but without long-range correlations. Particle noise in the form of high-frequency local motion and low-frequency global dynamics must be damped out. Damping the latter can be as computationally intensive as the actual simulation. We discuss a new and straightforward relaxation method, halted-pendulum relaxation (HPR), to remove global oscillation modes of SPH particle configurations. In combination with effective external potentials representing gravitational and orbital forces, we show that HPR has an excellent performance in efficiently relaxing SPH particles to the desired density distribution and removing global oscillation modes. We compare the method to frequently used relaxation approaches and test it on a white dwarf binary model at its Roche-lobe overflow limit. We highlight the importance of our method in achieving accurate initial conditions and its effect on achieving circular orbits and realistic accretion rates when compared with other general relaxation methods.

79 ASTRONOMY AND ASTROPHYSICS↗

Catalyst Design in Nitrate Removal

Based on the volcano plot developed by Dr. Goldsmith group (Report linked in submission), we utilized DFT (density functional theory) calculations to search for bimetallic materials in the application of catalysts in aqueous nitrate removal. The calculations are conducted via the high-throughput automated workflow package developed by our group (Github linked in submission) using VASP commercial first-principles calculation software.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Simulations of Small-Pore Microchannel Plates for Fast Gated X-ray Imaging and Spectroscopy of High-Energy Density Plasmas

This poster describes work done at National Security Technologies, LLC (NSTec), and Sandia National Laboratories (SNL) over the past several years on the design and characterization of microchannel plate (MCP)-based fast-gated x-ray imagers for use on the SNL Z machine. These cameras use 10-micron-pore MCPs similar to the type used for spectroscopy and imaging applications at other facilities. To aid in the understanding of MCP behavior, we have developed a Monte Carlo simulation model for prediction of MCP response. The code contains a detailed physical model of the electron cascade and amplification process of the MCP that includes energy conservation for the secondary electrons, the effects of elastic scattering of low-energy electrons from the channel wall, and gain saturation mechanisms from wall charging and space charge. Our model can simulate MCP response for both static and pulsed voltage waveforms. Excellent agreement between the Monte Carlo simulations and laboratory measurements has been achieved. Here, we apply our simulation model to 2-micron-pore MCPs, which, while readily available from a variety of vendors, are not used in imaging applications. We investigated the DC and pulsed gain characteristics of such an MCP, with particular emphasis on dynamic range, temporal response, and spatial resolution. The results are compared to the predicted and measured characteristics of 10-micron-pore MCPs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

City Reach Code Technical Support Document

This report describes and analyzes a set of energy efficiency measures that will save 20% energy over ASHRAE Standard 90.1-2013. The measures will be used to formulate a Reach Code for cities aiming to go beyond national model energy codes. A coalition of U.S. cities together with other stakeholders wanted to facilitate the development of voluntary guidelines and standards that can be implemented in stages at the city level to improve building energy efficiency. The coalition's efforts are being supported by the U.S. Department of Energy via Pacific Northwest National Laboratory (PNNL) and in collaboration with the New Buildings Institute.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of hypersonic arcjet flow fields and surface heating of blunt bodies

A Gauss-Seidel implicit aerothermodynamic Navier-Stokes computational CFD code with thermochemical surface conditions (GIANTS) and with appropriate boundary conditions was developed for the analysis of hypersonic arcjet flows over large angle blunt bodies. Two-dimensional axisymmetric multicomponent full Navier-Stokes equations were solved, together with boundary conditions, to account for the surface slip, surface catalysis, and energy and mass conservation at the body surface. It is shown that the predictions for isothermal, noncatalytic, and no-slip surface conditions which are made using the GIANTS code with simple boundary conditions agree with those of the LAURA code, and the predicted normalized heating distributions over the forebody surface with boundary conditions for various cone angles are consistent with the trends of data from arcjet experiments.

Chen, Y.-K.↗

Analysis and fringe field scaling of a legacy set of electrostatic deflector aberration formulas [Chapter Seven]

In this work we performed an analysis of the derivation of first and second order analytic aberration formulas by Wollnik (1965) for the case of electrostatic deflectors in the horizontal plane. We found that these aberration formulas are valid for the main field of the deflector; however, they do not account for any fringe field effects. To address this issue, we modified the aberration formulas from Wollnik (1965) for a hard edge fringe field by scaling the particle inclinations at the entrance and exit edges of the deflector. These modified aberration formulas fully agree with electrostatic aberration formulas derived by Valetov and Berz (2020), as well as with differential-algebraic (DA) calculations of electrostatic deflector aberrations using the code COSY INFINITY.

43 PARTICLE ACCELERATORS↗